• 제목/요약/키워드: optimum ventilation system

검색결과 66건 처리시간 0.16초

성에제거 덕트 입구 가이드베인 형상이 노즐출구 유량분포특성에 미치는 영향 (Effects of an Inlet Guide Vane on the Flowrate Distribution Characteristics of the Nozzle Exit in a Defrost Duct System)

  • 김덕진;이지근
    • 한국자동차공학회논문집
    • /
    • 제16권4호
    • /
    • pp.88-96
    • /
    • 2008
  • Effects of the duct inlet guide vane on the flowrate distribution characteristics of the defroster nozzle exit in a defrost duct system were investigated experimentally to design the optimum heating, ventilation and air conditioning (HVAC) system applied in an automotive compartment. A 3-dimensional hot-wire anemometer system was used to measure the velocity field in the vicinity of the defroster nozzle jet flow and the velocity distributions near the windshield interior surface. At first, two cases of with- and without-duct inlet guide vanes were considered as the test condition, and then three cases of the duct inlet guide vane were tested to determine the optimum guide vane shape and their positions. The arrangement of the duct inlet guide vanes has an effect on the improved flowrate distribution at the defroster nozzle exit and near the windshield interior surface. However, the application of the lots of guide vane to control the flow direction leads to increase the flow resistance, resulting in the decreased flowrate issuing from the defroster nozzle. The shape of the duct inlet guide vane affects not only the flowrate distribution between the driver side and the assistant driver side but also the reduction of the flow resistance in the defrost duct system.

TBM 도로터널의 환기방식에 따른 최적단면 선정에 관한 연구 (A study on the selection of optimal cross section according to the ventilation system in TBM road tunnels)

  • 이호근;강현욱;김현수;김홍문
    • 한국터널지하공간학회 논문집
    • /
    • 제15권2호
    • /
    • pp.135-148
    • /
    • 2013
  • 최근 도로터널은 장대화되고 있으며 도심지 등의 장대 대심도 도로터널의 계획이 추진되고 있다. 이러한 장대, 대심도 터널 굴착공법은 NATM과 TBM 공법 등이 있으며 유럽에서는 약 80%, 기타 선진국에서도 약 30%의 교통터널에서 Shield TBM 공법을 적용하고 있다. 하지만 국내에서는 대부분의 장비가 외국에서 고가에 수입되고 있어 국내의 TBM 터널 보급률이 상당히 낮아 NATM 굴착방식이 보편적으로 적용되고 있는 실정이다. TBM 터널의 보급을 늘리기 위해서는 TBM 장비의 국내 수급을 통한 경제성의 확보가 필요하며 이를 위해 표준화된 TBM 구경의 선정이 시급한 실정이다. 따라서 본 연구에서는 도로터널의 표준화된 TBM 최적단면 선정을 위해 교통량에 따라 차로수의 규모 및 내부형상(단층 혹은 복층), 환기방식에 따른 TBM 굴착 내공단면을 활용 방안 등을 검토하여 최적 단면의 산출방안을 제시하고자 하였다.

The study on a ship energy management system applied rechargeable battery

  • Jang, Jae-Hee;Oh, Jin-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제38권2호
    • /
    • pp.202-207
    • /
    • 2014
  • Recently, the study of energy saving technology of ships begins in earnest, as energy saving policies are performed all around the world. SEMS (Ship Energy Management System) is one of the techniques to increase energy efficiency by applying to a independent system like a ship and offshore. SEMS is composed of Cooling Pump Control System (CPCS), Renewable Energy Emergency Power Control System (REEPCS), Load Control System (LCS), and Heating, Ventilation, and Air Conditioning System (HVACS). SEMS is enable to increase energy efficiency and achieve integrated management through the interlocking of each system. Especially, it is possible to improve the flexibility of the selection of the generator capacity in conjunction with a rechargeable battery and renewable energy. In this paper, SEMS applied rechargeable battery is proposed and simulated. By applying the rechargeable battery, it was confirmed that SEMS applied rechargeable battery can be operated at optimum efficiency of the generator.

카트리지 필터 여과집진기 충격기류시스템의 최적탈진조건에 관한 실험적 연구 (Experimental Study on Optimum Pulse Jet Cleaning Conditions of a Cartridge Filter System)

  • 박승욱;하현철;김성준
    • 한국산업보건학회지
    • /
    • 제25권4호
    • /
    • pp.542-553
    • /
    • 2015
  • Objectives: Many types of dust collector are used for industrial ventilation, with the most common types being the cylinder bag filter system, rectangular bag filter system and cylinder type cartridge filter system. The cylinder type cartridge bag filter, which has more filtering area than other types of bag filter, can increase the pulse time and extend the useful life of the filter. This can save operational costs and installation area. Materials: This study used cylinder type cartridge bag filter equipment and tested the impact of vibration level and filter pressure with different pulse jet cleaning conditions. The final, cleaning efficiency was calculated through input dust mass and cleaning dust mass Conclusions: Two optimum cleaning condition groups were found. The first condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.2 s pulse time with an H-10 type nozzle. The second condition group was $3kgf/cm^2$ pulse pressure, 15 cm pulse distance, 0.3 s pulse time with an H-10 type nozzle.

Characterization of Fruitbody Morphology on Various Environmental Conditions in Pleurotus ostreatus

  • Jang, Kab-Yeul;Jhune, Chang-Sung;Park, Jeong-Sik;Cho, Soo-Muk;Weon, Hang-Yeon;Cheong, Jong-Chun;Choi, Sun-Gyu;Sung, Jae-Mo
    • Mycobiology
    • /
    • 제31권3호
    • /
    • pp.145-150
    • /
    • 2003
  • This study investigated the morphological differences of P. ostreatus grown in the artificial environmental conditions such as humidity, temperature, ventilation, and watering. Oyster mushroom, which was cultivated on artificial environmental condition, was shown to have different morphology of fruitbodies. The optimum $CO_2$ concentration for good morphology of P.ostreatus was 0.3%. But most fruitbody showed the morphologically low qualities in more than 0.5% of $CO_2$ concentration. In the humidity in excess of 80% at $13{\sim}16^{\circ}C$, the best morphology of P. ostreatus was investigated. The growth of fruitbodies of P. ostreatus in the ventilation system was good at the wind velocity ranging from $0.2{\sim}0.5$ fpms and expouring type. In other conditions, P. ostreatus generally showed the morphology closing to malformation.

최적화 생산시스템 모델 개발을 위한 양돈시설의 조사 연구 (Study on the Swine Farming Facilities by Survey for the Development of the Optimum Production System Models)

  • 장동일;이봉덕;조한근;장홍희
    • 한국축산시설환경학회지
    • /
    • 제2권1호
    • /
    • pp.1-11
    • /
    • 1996
  • 본 연구는 사육, 급사, 급수, 번식, 건강 관리, 환기 및 열 관리, 자료 분석 등에 대한 기계화 및 자동화의 현황과 수준을 분석 평가하고, 이를 토대로 양돈 시설의 최적화 생산 시스템 모델 개발의 연구 방향을 설정하기 위하여 수행되었으며 앞으로의 연구 방향을 다음과 같이 설정하였다. 1) 종모돈, 종빈돈, 분만돈은 단사식으로 사육하고, 자돈, 육성돈, 비육돈은 군사식으로 사육하는 것과 돈방 배열은 복열식으로 하는 것을 기준으로 한국형 환경 제어용 스라트 무창돈사를 개발한다. 2) 한국형 환경 제어용 스라트 무창돈사에 적합한 환경 제어 시스템과 분뇨 처리 시스템을 개발한다. 3) 전자식 개체식별장치를 개발한다. 4) 전자식 개체식별장치와 컴퓨터를 이용한 자동 개체 습식 급사 시스템을 개발한다. 5) 번식돈을 위한 전자식 개체식별장치에 의한 개체 관리 시스템을 개발한다. 6) 건강 관리 및 자료 분석 등을 종합 관리할 수 있는 전문가 시스템을 개발한다.

  • PDF

나노 임프린트 장비 최적 환경을 위한 제어 장비 및 시스템에 관한 연구 (A study on control unit and system for nanoimprint equipment of the optimum conditions.)

  • 박경서;김우송;임홍재;장시열;이기성;정재일;임시형;신동훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2375-2380
    • /
    • 2008
  • Controlling of thermal environment and flow in nanoimprint process chamber is important to ensure high precision levels of products. The purpose of this paper is to build optimal nanoimprint process environment. Because of this, Optimum PI control parameter for precise temperature control has been examined. Also porous medium of ventilation system is simulated for uniform flow in the equipment chamber. The porous medium consists of mesh structure, and is installed to place which flow the influx of the air flows. PID control parameter is based on the data obtained by experiment. And then heating and cooling method which simultaneously operated was used for decreasing an error. In conclude temperature in the equipment chamber was able to control precisely in the range of ${\pm}0.1^{\circ}C$ by the PID control parameter and Deadband.

  • PDF

이론적 열유동 해석을 이용한 농산물 저장 및 유통 스마트 유닛로드 컨테이너의 통기공 최적화 설계 (Ventilation Hole Optimum Design of Smart Unit Load Container for Storage and Distribution Agricultural Products by Theoretical Heat Flow Analysis)

  • 최동수;김용훈;김진세;박천완;정현모;김기석;박종민
    • 한국포장학회지
    • /
    • 제28권3호
    • /
    • pp.211-215
    • /
    • 2022
  • Air distribution occupies an important position in the smart unit load container design process for agricultural products. Inner air may be uncomfortable because of its temperature, speed, direction, and volume flow rate. It doesn't matter how efficient the ventilation equipment is if the air is not distributed well. The main aim of this study was to design the inlet and outlet fan locations of smart unit load container for agricultural products. A numerical study was performed on the effects of the location of inlet air and outlet air in relation to the container cooling sources on air distribution and thermal comfort. A concept of combining inner container cooling sources with the exhaust outlet was employed in this investigation. Also, in this research, the developed CFD (Computational Fluid Dynamics) models were thoroughly validated. This system was adopted for use in container spaces, where the exhaust outlet was located. In this study, the location of the inlet was derived through CFD for a container with a size of 1,100×1,100×1,700 mm, and it was derived that the inlet was located at the center of the lower part of the container for efficient air flow. It was efficient to position the outlet through the air inlet in the center of the lower part of the container at the top of the same side.

지하역사 공기여과장치 표준화방안 사전연구 (A preliminary study of Standardization Plan on Underground Air filtration Facility)

  • 배성준;황선호;신창헌
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2009년도 춘계학술대회 논문집
    • /
    • pp.919-929
    • /
    • 2009
  • 2008, Seoulmetro transports an average of 3,952,000 passengers every day with a 0.8% increase of the daily ridership compared to last year.(Korean Economics '09.01.21) Seoul subway systems ridden by a considerable number of Seoul citizens place their top priority on swiftness, safety and clean underground air quality so as to meet the customer satisfaction. One of the most important problems is to eliminate minute dust(PM10) among the pollutants such as the gas attributable to air pollution and floating particulate matter defined by the ordinance of the Ministry of Environment. Seoulmetro install and operate many kinds of air filtration facilities, however we've launched a research on "Standardization Plan on Underground Air Filtration Facility" for the installation and improvement of optimum standardized air filtration system. As a preliminary study, we're going to consider ventilation system and air filter to supply filtered metropolitan outdoor air aimed at ensuring clean underground environment.

  • PDF

설비공학 분야의 최근 연구 동향 : 2013년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research : A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2013)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제26권12호
    • /
    • pp.605-619
    • /
    • 2014
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2013. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of fluid machinery, pipes and relative parts including orifices, dampers and ducts, fuel cells and power plants, cooling and air-conditioning, heat and mass transfer, two phase flow, and the flow around buildings and structures. Research issues dealing with home appliances, flows around buildings, nuclear power plant, and manufacturing processes are newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for general analytical model for desiccant wheels, the effects of water absorption on the thermal conductivity of insulation materials, thermal properties of Octadecane/xGnP shape-stabilized phase change materials and $CO_2$ and $CO_2$-Hydrate mixture, effect of ground source heat pump system, the heat flux meter location for the performance test of a refrigerator vacuum insulation panel, a parallel flow evaporator for a heat pump dryer, the condensation risk assessment of vacuum multi-layer glass and triple glass, optimization of a forced convection type PCM refrigeration module, surface temperature sensor using fluorescent nanoporous thin film. In the area of pool boiling and condensing heat transfer, researches on ammonia inside horizontal smooth small tube, R1234yf on various enhanced surfaces, HFC32/HFC152a on a plain surface, spray cooling up to critical heat flux on a low-fin enhanced surface were actively carried out. In the area of industrial heat exchangers, researches on a fin tube type adsorber, the mass-transfer kinetics of a fin-tube-type adsorption bed, fin-and-tube heat exchangers having sine wave fins and oval tubes, louvered fin heat exchanger were performed. (3) In the field of refrigeration, studies are categorized into three groups namely refrigeration cycle, refrigerant and modeling and control. In the category of refrigeration cycle, studies were focused on the enhancement or optimization of experimental or commercial systems including a R410a VRF(Various Refrigerant Flow) heat pump, a R134a 2-stage screw heat pump and a R134a double-heat source automotive air-conditioner system. In the category of refrigerant, studies were carried out for the application of alternative refrigerants or refrigeration technologies including $CO_2$ water heaters, a R1234yf automotive air-conditioner, a R436b water cooler and a thermoelectric refrigerator. In the category of modeling and control, theoretical and experimental studies were carried out to predict the performance of various thermal and control systems including the long-term energy analysis of a geo-thermal heat pump system coupled to cast-in-place energy piles, the dynamic simulation of a water heater-coupled hybrid heat pump and the numerical simulation of an integral optimum regulating controller for a system heat pump. (4) In building mechanical system research fields, twenty one studies were conducted to achieve effective design of the mechanical systems, and also to maximize the energy efficiency of buildings. The topics of the studies included heating and cooling, HVAC system, ventilation, and renewable energies in the buildings. Proposed designs, performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment is mostly focused on indoor environment and building energy. The main researches of indoor environment are related to infiltration, ventilation, leak flow and airtightness performance in residential building. The subjects of building energy are worked on energy saving, operation method and optimum operation of building energy systems. The remained studies are related to the special facility such as cleanroom, internet data center and biosafety laboratory. water supply and drain system, defining standard input variables of BIM (Building Information Modeling) for facility management system, estimating capability and providing operation guidelines of subway station as shelter for refuge and evaluation of pollutant emissions from furniture-like products.