굴착중인 장대터널 내 최적의 환기시스템에 관한 연구 (The Study on Optimum Ventilation System during Long Tunnel Construction)

  • 임한욱;오병화
    • 산업기술연구
    • /
    • 제26권A호
    • /
    • pp.3-15
    • /
    • 2006
  • To determine the optimum ventilation systems during long tunnel excavation, the velocity vector profile and the contaminant's distribution at working place are studied using 2-D, 3-D numerical analysis. The main results can be summarized as follow; In case of long tunnels, blower-exhaust-mixture types which enable to use soft blast ducts is most appropriate in terms of ventilation and economical efficiency. Of the same ventilation types, ventilation efficiency has a difference according to blast ducts and the distance between fan and working place. The 3-D numerical result shows that arranging blower and exhaust ducts in the right and left corners of the tunnel respectively is effective to discharge contaminant. The result of the real measurement shows that CO concentration can be reduced to below 50 ppm, which is regulation value, as 16-minutes fan operation goes on.

  • PDF

지하철 환기시스템의 최적화에 관한 연구 (Study on optimization technique for the design of ventilation system of subway)

  • 김광용;조재형;리쉬밍;양태윤
    • 설비공학논문집
    • /
    • 제10권5호
    • /
    • pp.630-639
    • /
    • 1998
  • The present research aimed at development of a computer code for the optimal design of ventilation system based on one-dimensional analysis of the air flow. Model experiment and three-dimensional flow analysis have been implemented to determine loss coefficients that were needed for the optimization technique. A research on optimum shape of ventilation shaft has been also carried out through the three-dimensional analysis of the flow.

  • PDF

압력손실을 고려한 양돈시설의 반폐회로 환기시스템의 환기량 및 혼합비율 평가 (Evaluation of Ventilation Rate and External Air Mixing Ratio in Semi-closed Loop Ventilation System of Pig House Considering Pressure Loss)

  • 박유미;김락우;김준규
    • 한국농공학회논문집
    • /
    • 제65권1호
    • /
    • pp.61-72
    • /
    • 2023
  • The increase in the rearing intensity of pigs has caused deterioration in the pig house's internal environment such as temperature, humidity, ammonia gas, and so on. Traditionally, the widely used method to control the internal environment was through the manipulation of the ventilation system. However, the conventional ventilation system had a limitation to control the internal environment, prevent livestock disease, save energy, and reduce odor emission. To overcome this problem, the air-recirculated ventilation system was suggested. This system has a semi-closed loop ventilation type. For designing this system, it was essential to evaluate the ventilation rates considering the pressure loss of ducts. Therefore, in this study, pressure loss calculation and experiment were conducted for the quantitative ventilation design of a semi-closed loop system. The results of the experiment showed that the inlet through which external air flows should always be opened. In addition, it was also found that for the optimum design of the semi-closed loop ventilation system, it was appropriate to install a damper or a backflow prevention device rather than a ventilation fan.

주방 환기에 대한 조리사들의 인식도 연구 - 서울 지역을 대상으로 - (A Study on the Recognition of Cooks about the Kitchen Ventilation)

  • 반주원;허준
    • 한국조리학회지
    • /
    • 제11권4호
    • /
    • pp.228-244
    • /
    • 2005
  • The objective of the study is to observe cooks first from the kitchen and those who care health and to grasp the impression regarding the kitchen environment. Also, it grasped the recognition degree of cooks against the elements of kitchen ventilation and kitchen ventilation equipments. We surveyed against 385 cooks who work in the kitchen of special grade hotels and family restaurants, used 5 scales for the object, and executed the analysis. The results of this study are as follows: (1) Health condition of the cooks appeared most highly pain in the shoulder and the neck. (2) for the impression regarding the kitchen environment, temperature was high and the insufficiency of ventilation is answered highly. (3) The importance of kitchen ventilation of cooks was recognized very high. (4) The combustion gas was recognized as very high percentage and the most effective element of the kitchen on the human body to remove first inside the kitchen. (5) Most cooks were recognized that the improvement of ventilation equipments is necessary. (6) The object of ventilation equipments is appeared to maintain comfortable kitchen environment. (7) The optimum operation method of ventilation equipment uses the automatic system of ventilation equipment from the kitchen and it is necessary to maintain the optimum. This research is based on preceding studies, investigating special grade hotels and family restaurants in Seoul. The ventilation plan of the kitchen should be accomplished to improve the health of cooks and productivity.

  • PDF

자연환기 시스템을 이용한 고층 공동주택의 환기성능 향상에 관한 연구 (A Study on Improving Ventilation Performance in High-rise Residential Building by Natural Ventilation System)

  • 최태환;김유미;김태연;이승복
    • KIEAE Journal
    • /
    • 제7권4호
    • /
    • pp.51-56
    • /
    • 2007
  • This study focuses on developing natural ventilation system which is able to satisfy the good indoor air quality and air speed. The natural ventilation system developed in this study is for double window façade and it has two operation modes for summer and winter. Operational sections of the devices have been analyzed by CFD simulation to calculate discharge coefficients of openings and estimated indoor air speed. For the analysis of the appropriate installation area ratio for each room and the optimum installation area, TRNFLOW simulation has been used. As the results, we could see that the natural ventilation system can provide the similar pollutant removal performance to 0.7 ACH of mechanical ventilation with appropriate installation area and installation area ratio.

굴착중인 장대터널내 최적의 환기시스템에 대한 연구 (The Study on Optimum Ventilation System during Long Tunnel Construction)

  • 오병화;임한욱
    • 화약ㆍ발파
    • /
    • 제24권2호
    • /
    • pp.9-22
    • /
    • 2006
  • 길이가 대단히 짧은 터널을 제외하고는 터널을 시공하는 경우 일반적으로 인위적인 환기시스템이 필요하다. 특히 장대터널의 경우 굴착 진행에 따라 적절한 환기시스템을 조합해서 사용하는 것이 효과적이다. 터널 연장이 4,580m인 능동터널은 본래 송기식을 사용하는 것으로 설계를 했지만, 굴착이 진행됨에 따라 송기식만으로 환기하는 데에는 한계가 예상되어 별도의 방식 검토를 수행하였다. 굴착중 터널의 소요환기량을 산정하고 이 소요환기량과 선택가능한 여러 가지 경우의 환기조합방식을 사례볕로 구성한 뒤 환기량과 유동성을 해석하고 비교함으로써 경제적으로도 우수한 최적의 환기조합안을 도출하였다. 환기시스템을 결정하기 위하여 각 환기시스템에 대한 경제적 효율성 평가를 수행하였다.

Push-Pull 국소환기시스템 개선에 관한 수치해석 (A Numerical Analysis on Improvement of Push-Pull Local Ventilation System)

  • 이중섭;장성철;윤강로
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.594-599
    • /
    • 2007
  • This study represents numerical analysis on the fluid flow and concentration characteristics by scattering fume at push-pull ventilation system. And the principal point is making optimum on improve an existing ventilation system. This phenomenon simulated about local ventilation system by using commercial CFD tool and base on these fact has find improvements. Advanced model shows most low different pressure and velocity which are suction capability at inlet surface of pull hood has most uniformity. When compared with existing model, Improved model has more good ventilation performance.

  • PDF

The investigation of combined ventilation-biofilter systems using recycled treated wastewater on odor reduction efficiency

  • Febrisiantosa, Andi;Choi, Hong L.;Renggaman, Anriansyah;Sudiarto, Sartika I.A.;Lee, Joonhee
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제33권7호
    • /
    • pp.1209-1216
    • /
    • 2020
  • Objective: The present study aimed to evaluate the performance of odor abatement by using two different ventilation-biofilter systems with recycled stablized swine wastewater. Methods: The performance of odor removal efficiency was evaluated using two different ventilation-biofilter-recycled wastewater arrangements. A recirculating air-flow ventilation system connected to a vertical biofilter (M1) and a plug-flow ventilation system connected to a horizontal biofilter (M2) were installed. Water dripping over the surface of the biofilter was recycled at a flow rate of 0.83 L/h in summer and 0.58 L/h in winter to reduce odorous compounds and particulate matter (PM). The experiments were performed for 64 days with M1 and M2 to investigate how these two ventilation-biofilter systems influenced the reduction of odor compounds in the model houses. Odorous compounds, NH3 and volatile organic compounds (VOCs) were analyzed, and microclimatic variables such as temperature, humidity, and PM were monitored. Results: Ammonia concentration inside M1 was about 41% higher on average than that in M2. PM and total suspended particles (TSPs) inside M1 were about 62.2% and 69.9%, respectively, higher than those in M2. TSPs in the model house were positively correlated with the concentration of NH3 and VOCs. Conclusion: M2 emitted lower concentration of odorous compounds than M1. Moreover, M2 could maintain the optimum temperature condition for a swine house during the cooler season. The plug-flow ventilation-horizontal biofilter system could be used for pig houses to minimize air pollution produced by swine farming activities and maintain optimum microclimate conditions for pigs.

교통환기력에 의한 터널내 환기량 추정에 관한 연구 (Estimation of Ventilation Volume by Traffic Ventilation Force in Tunnel)

  • 김종호;이상칠;도연지;김신도
    • 한국대기환경학회지
    • /
    • 제11권3호
    • /
    • pp.273-278
    • /
    • 1995
  • This study is to estimate the ventilation volume by the traffic that originated from driving automobiles for two tunnels (Kugi tunnel and Kumhwa tunnel) that adopted natural ventilation system among tunnels of Seoul, and on the basis of which, we estimated the ventilation velume at various conditions. With the result of the estimation, we will present the basic method that can be operated with the optimum condition for the ventilation system. Estimating the predicted ventilation volume in the tennel by the pollutant concentration, we used traffic volume and CO emission data by the automobile speed and CO concentration in the tunnel. And, when we estimated the traffic ventilation volume by natural and traffic ventilation force, we used traffic volume, automobile speed, tunnel area, automobile area data and so on. As the result of simple regression between predicted ventilation volume and traffic ventilation volume, we attained the regression coefficient 0.88, and achieved the relation form that predicted ventilation volume equal 0.12x traffic ventilation volume-92, 000. Using this equation, we estimated the ventilation volume to satisfy the enviromnental standards of several space, and calculated the required volume for mechanical ventilation. Incase of Kumhwa Tunnel, there is a need of mechanical ventilation all day long to satisfy air quality standard 9 ppm for 8 hours average and 10 ppm for the indoor air quality standard of public facilities.

  • PDF

도로터널용 전기집진시스템 개발 (Development of Road Tunnel Ventilation System with Electrostatic Precipitator)

  • 김종률;원종웅
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 동계학술발표대회 논문집
    • /
    • pp.80-83
    • /
    • 2008
  • As SOC (Social Overhead Capital) has been expanded, the highway road construction has been accelerated and city road system has been more complicated. So, long road tunnels have been increased and traffic flow rate also has been raised. Accordingly, the exhausting gas of vehicle cars seriously deteriorates the tunnel inside air quality and driving view. In order to improve tunnel inside air quality, we may need to introduce a compulsory ventilation system as well as natural ventilation mechanism. The natural ventilation mechanism is enough for short tunnels, meanwhile longer tunnels require a specific compulsory ventilation facility. Many foreign countries already have been devoting on development of effective tunnel ventilation system and especially, some European nations and Japan have already applied their developed tunnel ventilation system for longer road tunnels. More recently, as the quality of life improved, our concerns about safety of driving and better driving environment have been increased. In order to obtain clearer and longer driving view, we are more interested in EP tunnel ventilation system in order to remove floating contaminants and automobile exhaust gas. Evan though it's been a long time since many European countries and Japan applied more economical and environment-friendly tunnel ventilation system with their self-developed Electrostatic Precipitator, we are still dependant on imported system from foreign nations. Therefore, we need to develop our unique technical know-how for optimum design tools through validity investigation and continuous possibility examination, eventually in order to localize the tunnel ventilation system technology. In this project, we will manufacture test-run products to examine the performance of system in order to develop main parts of tunnel ventilation system such as electrostatic precipitator, high voltage power generator, water treatment system, etc.

  • PDF