• Title/Summary/Keyword: optimum site

Search Result 484, Processing Time 0.028 seconds

A Study on the Optimum Design Flowrate for Tunnel-Type Small Hydro Power Plants

  • Lee, Chul-Hyung;Park, Wan-Soon
    • Korean Journal of Hydrosciences
    • /
    • v.3
    • /
    • pp.81-96
    • /
    • 1992
  • This study represents the methodology for feasibility analysis of small hydro power SHP plant. Cumulative density function of Weibull distribution and Thiessen method were adopted to decide flow duration curve at SHP candidate site. The perfomance prediction model and construction cost estimation model for tunnel-type SHP plant were developed. Eight tunnel -type SHP candidate sites existing on Han-river were selected and surveyed for actual site reconnaissance. The performance characteristics and economical feasibility for these sites were analyzed by using developed models. As a result, it was found that the optimum design flowrate with the lowest unit generation cost for tunel-type SHP candidate site were the flowrate concerming with between 20% and 30% of time ratio on the flow duration curve. Additionally, primary design specifications such as design flowrate, effective head, capacity, annual averageload factor, annual electricity production were estimated and discussed for eight surveyed SHP candidate sites.

  • PDF

On-Site Treatment of Soil Contaminated by Heavy Metals and Petroleum using Relocatable Soil Washing Equipment

  • Kim, Taeeung
    • International journal of advanced smart convergence
    • /
    • v.9 no.1
    • /
    • pp.19-28
    • /
    • 2020
  • We studied the on-site treatment of soil contaminated by heavy metals and petroleum was tested using relocatable soil washing equipment for greater remediation efficiency. Different combinations of pH and solid/liquid ratio were tested to determine the optimum balance, settling on values of 5 and 1:2, respectively. Next, soils containing Pb, Hg, and petroleum were further tested to assess the optimum number of washing cycles. The remediation efficiency of Pb and Hg in soil contaminated solely by heavy metals was 90.1% and 86.4% after three and two washings, respectively. The remediation efficiency of petroleum in soil contaminated solely by petroleum was 98.8% after one washing. When soil contaminated by both heavy metals and petroleum was cleaned, up to 91.0% of Pb, 86.9% of Hg, and 96.1% of petroleum was removed after two, one, and one washings, respectively. We conducted all remediation efficiencies and concentration reductions satisfied the standard threshold for soil contamination in South Korea.

Investigation of Soil Physico-chemical Properties in Saemangeum Reclaimed Tidal Land in Korea

  • Ahn, Byung-Koo;Lim, Yeon-Yi;Ko, Do-Young;Lee, Chang-Kyu;Kim, Jin-Ho;Song, Young-Ju;Lee, Jin-Ho
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.49 no.4
    • /
    • pp.347-354
    • /
    • 2016
  • This study was conducted to investigate the physical and chemical properties of soils in Saemangeum reclaimed lands. The investigated areas were total 5,020 ha which included 220 ha for Agricultural Life site, 2,450 ha for Tourism & Leisure site, 1,130 ha for Industrial & Research site, 820 ha for Bioenergy crop production site, and 400 ha for Rural City site. Soil samples consisting of the upper 20 cm from the surface were collected in every $200m{\times}500m$ of the each site in March and September, 2015. Particle size distribution of soils in the reclaimed land was 83.2% sand, 8.6% silt and 8.2% clay in average. Soil texture was distributed as 40.8% sandy soil, 35.5% loamy sand, and 19.7% sandy loam. Based on the investigation of soil chemical properties conducted in March, 2015, soil pH, electrical conductivity of a saturated soil paste extract (ECe), and exchangeable (Exch.) $K^+$ and $Mg^{2+}$ concentrations were higher than those of the optimum levels for upland soil, whereas soil organic matter content, available (Avail.) phosphate concentration, and Exch. $Ca^{2+}$ concentration were lower than those of the optimum ranges. Depending on the results of the soil chemical properties measured in September, 2015, soil pH, ECe, and Exch. $K^+$ concentration were higher than those of the optimum levels, but soil organic matter, Avail. phosphate, and Exch. $Ca^{2+}$ concentration were lower than the optimum ranges. In addition, distribution of sodic soil ranged between 41.4% and 50.0%, and saline soils were from 16.4 to 31.8%. Soils with pH values above 7.0 increased from 15.3% in March to 35.2% in September. Soils with ECe values over $4.8dS\;m^{-1}$ increased from 45.6% to 50.7%, whereas soils with the values below $2.0dS\;m^{-1}$ decreased from 42.8% to 36.9%.

GIS Applications for Optimum Site Selection of Public Facility (도시공공시설 적지선정을 위한 GIS 활용방안에 관한 연구)

  • Kim, Jae Ik;Chung, Hyun Wook
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.4 no.4
    • /
    • pp.8-20
    • /
    • 2001
  • The main purpose of this study is to introduce a new method of evaluation, and to suggest how to apply geographic information system for optimum public facility site selection. For this purpose, a new evaluation model for the site selection is developed. The model provides a simple and easy method of evaluation. It also allows differences among location factors through two step weighting procedures. For a better understanding of the model, solution procedures and visual figures are illustrated with the case of Dalseong-Gun's city hall location example.

  • PDF

Optimum Macro-Siting for Offshore Wind Farm Using RDAPS Sea Wind Model (RDAPS Sea Wind Model을 이용한 해상풍력발전단지 최적 Macro-Siting)

  • Lee, K.H.;Jun, S.O.;Park, K.H.;Lee, D.H.;Park, Jong-Po
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.286-290
    • /
    • 2011
  • This paper introduces the optimum macro-siting of a potential site for an offshore wind farm around Jeju Island using the RDAPS sea wind model. The statistical model was developed by analyzing the sea wind data from RDAPS model, and the meso-scale digital wind map was prepared. To develop the high resolution spatial calibration model, Artificial Neural Network(ANN) models were used to construct the wind and bathymetric maps. Accuracy and consistency of wind/bathymetric spatial calibration models were obtained using analysis of variance. The optimization problem was defined to maximize the energy density satisfying the criteria of maximum water depth and maximum distance from the coastline. The candidate site was selected through Genetic Algorithm(GA). From the results, it is possible to predict roughly a candidate site location for the installation of the offshore wind jam, and to evaluate the wind resources of the proposed site.

  • PDF

A Study on the Optimum Mix Proportion of the Mass Concrete Designed as Massive and Deep Structure

  • Kwon Yeong-Ho;Lee Hwa-Jin
    • Journal of the Korea Concrete Institute
    • /
    • v.17 no.2 s.86
    • /
    • pp.293-302
    • /
    • 2005
  • This study describes data from determination of the optimum mix proportion and site application of the mass concrete placed in bottom slab and side wall having a large depth and section as main structures of LNG in-ground tank. This concrete requires low heat hydration, excellent balance between workability and consistency because concreting work of LNG in-ground tank is usually classified by under-pumping, adaptation of longer vertical and horizontal pumping line than ordinary pumping condition. For this purpose, low heat Portland cement and lime stone powder as cementitious materials are selected and design factors including unit cement and water content, water-binder ratio, fine aggregate ratio and adiabatic temperature rising are tested in the laboratory and batch plant. As experimental results, the optimum unit cement and water content are selected under $270kg/m^3$ and $l55{\~}l60 kg/m^3$ separately to control adiabatic temperature rising below $30^{\circ}C$ and to improve properties of the fresh and hardened concrete. Also, considering test results of the confined water ratio($\beta$p) and deformable coefficient(Ep), $30\%$ of lime stone powder by cement weight is selected as the optimum replacement ratio. After mix proportions of 5cases are tested and compared the adiabatic temperature rising($Q^{\infty}$, r), tensile and compressive strength, modulus of elasticity, teases satisfied with the required performances are chosen as the optimum mix design proportions of the side wall and bottom slab concrete. $Q^{\infty}$ and r are proved smaller than those of another project. Before application in the site, properties of the fresh concrete and actual mixing time by its ampere load are checked in the batch plant. Based on the results of this study, the optimum mix proportions of the massive concrete are applied successfully to the bottom slab and side wall in LNG in-ground tank.

An Experimental Study on the Optimum Mix Design and Site Application Case of Soil Mixing Wall for Trench Stability (구벽안정성을 위한 SMW 최적배합비 및 현장적용 사례에 관한 연구)

  • Kwon, Yeong-Ho
    • Journal of the Korea Concrete Institute
    • /
    • v.27 no.4
    • /
    • pp.419-426
    • /
    • 2015
  • The purpose of this study is to investigate experimentally the optimum mix design and site application case of soil mixing wall (SMW) method which is cost-effective technique for construction of walls for cutoff wall and excavation support as well as for ground improvement before constructing LNG storage tank typed under-ground. Considering native soil condition in site, main materials are selected ordinary portland cement, bentonite as a binder slurry and also it is applied $1,833kg/m^3$ as an unit volume weight of native soil, Variations for soil mixing wall are as followings ; (1) water-cement ratio 4cases (2) mixing velocity (rpm) 3levels (3) bleeding capacity and ratio, compressive strength in laboratory and site application test. As test results, bleeding capacity and ratio are decreased in case of decreasing water-cement ratio and increasing mixing velocity. Required compressive strength (1.5 MPa) considering safety factors in site is satisfied with the range of water-cement ratio 150% below, and test results of core strength are higher than those of specimen strength in the range of 8~23% by actual application of element members including outside and inside in site construction work. Therefore, optimum mix design of soil mixing wall is proposed in the range of unit cement $280kg/m^3$, unit bentonite $10kg/m^3$, water-cement ratio 150% and mixing velocity 90rpm and test results of site application case are satisfied with the required properties.

Changes in Optimum pH and Thermostability of $\alpha$-amylase from Bacillus licheniformis by Site-directed Mutagenesis of His 235 and Asp 328

  • Kim, Mi-Sook;Lee, Sang-Kyou;Jung, Han-Seung;Yang, Chul-Hak
    • Bulletin of the Korean Chemical Society
    • /
    • v.15 no.10
    • /
    • pp.832-835
    • /
    • 1994
  • The ${alpha}$-amylase gene of Bacillus licheniformis has been cloned and two mutant ${alpha}$-amylase genes of which histidine 235 was changed to glutamine (H235Q) and aspartic acid 328 to glutamic acid (D328E) have been produced by site-directed mutagenesis. The kinetic parameters, optimum pH and thermostability of wild type(WT) and these two mutant amylases expressed in E. coli MC1061 have been compared after purification. The $K_m$ values of WT, H235Q and D328E ${alpha}$-amylases were 0.22%, 0.73%, and 0.80% respectively, when using starch as the substrate. The $V_max$ values of wild type ${alpha}$ -amylase and mutant ${alpha}$-amylases were 0.6-0.7%/minute, and did not show any significant differences among them. The optimum pH of D328E ${alpha}$-amylase was shifted to more acidic pH. Also, the thermostability of H235Q ${alpha}$-amylase was increased compared to the wild type ${alpha}$-amylase.

Construction technology of the massive bottom slab placed by $23,000m^3$ concrete quantity ($23,000m^3$ 대용량 바닥스래브 콘크리트의 시공기술)

  • 권영호;이현호;하재담
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2003.05a
    • /
    • pp.1035-1040
    • /
    • 2003
  • This research investigates the actual data and construction technology of the massive bottom slab placed by $23,000m^3$ concrete quantity in site of the in-ground type LNG receiving terminal having 20,000kl storage capacity. The purpose of this study is to determine the optimum mix design and control the actual concreting procedures including concrete production, transportation, placement, vibrating and curing in site. For this purpose, the optimum mix design using ternary blended cement(furnace slag cement+fly ash) and under piping method having 11 gates and 7 distributors are selected. As test results of actual construction, concrete placement is finished during 68hours with good success and obtained the good quality of the fresh and hardened concrete including slump, air contents, no-segregation, compressive strength and low hydration heat. Also, actual data for all of concrete procedures are proved successful and satisfied with our specifications.

  • PDF