• 제목/요약/키워드: optimum pressure

검색결과 1,729건 처리시간 0.036초

Simulations of the Performance Factors on Vacuum System

  • Kim, Hyung-Taek
    • International journal of advanced smart convergence
    • /
    • 제6권4호
    • /
    • pp.1-8
    • /
    • 2017
  • In this work, the effects of fairly influential factors on performance of vacuum system, such as constant pressure and outgassing effect were simulated to propose the optimum design factors. Outgassing effects of selected vacuum materials on the vacuum characteristics were simulated by the $VacSim^{Multi}$ simulation tool. This investigation examined the feasibility of reliably simulating the outgassing characteristics of common vacuum chamber materials (aluminum, copper, stainless steel, nickel plated steel, Viton A). The optimum design factors for vacuum systems were suggested based on the simulation results. And, the effects of throttle valve applications on vacuum characteristics were also simulated to obtain the optimum design model of variable conductance on high vacuum system. Simulated vacuum characteristics of the proposed modelling were agreed with the observed experimental behaviour of real systems. Pressure limit valve and normally on-off control valve were schematized as the modelling of throttle valve for the constant process-pressure. Simulation results were plotted as pump-down curve of chamber and variable conductance of throttle valve. Simulated behaviors showed the applications of throttle valve sustained the process-pressure constantly, stably, and reliably.

냉.온열 동시 제조시스템의 성능분석(I)-Simulation (Performance Analysis of Simultaneous Heating & Cooling Water Making System(I)-Simulation)

  • 박성룡;박준택;안영훈
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.266-271
    • /
    • 2001
  • In this study, the performance of the simultaneous heating & cooling water making system using R134a was investigated by simulation. The most important effect upon heating COP was intermediate pressure depending on input water temperature. With the input water temperature of $10^{\circ}C\;and\;20^{\circ}C$, optimum intermediate pressure were 923 and 1040kPa, respectively. At that optimum intermediate pressure, the maximum heating COP of the system operated between $0^{\circ}C$ evaporating temperature and $70^{\circ}C$ condensing temperature were 4.15 and 3.83. With installation of the subcoolers in high or low pressure section, the system COP was increased by reducing the refrigerant mass flow rate. Under the optimum pressure and $10^{\circ}C$ input water temperature, it was found that heating COP was maximized when the low-subcooler and high-subcooler capacity rate were taken by 14% and 13%, respectively.

  • PDF

$CO_2$ 자동차 에어컨 시스템의 최적 고압 설정 알고리즘 개발에 관한 연구 (Development of Optimum High Pressure Algorithm for a Transcritical $CO_2$ Mobile Air-Conditioning System)

  • 이종붕;이준경
    • 한국자동차공학회논문집
    • /
    • 제16권3호
    • /
    • pp.159-165
    • /
    • 2008
  • This paper deals with the optimum high pressure control algorithm for a transcritical $CO_2$ mobile air-conditioning system with belt-driven compressor to achieve the maximum COP. The experiments were performed to find out the maximum COP conditions with various operating conditions. The experimental results showed that the COP was increased and then decreased with increase of the refrigerant high pressure for the system. Therefore the value of high pressure which has maximum COP could be selected. Furthermore, the strong (linear) relation between the optimum high pressure and the gas cooler outlet temperature was revealed, which suggests the use of a simple controller with only one parameter for the transcritical $CO_2$ cycle.

The optimum steel fiber reinforcement for prestressed concrete containment under internal pressure

  • Zheng, Zhi;Sun, Ye;Pan, Xiaolan;Su, Chunyang;Kong, Jingchang
    • Nuclear Engineering and Technology
    • /
    • 제54권6호
    • /
    • pp.2156-2172
    • /
    • 2022
  • This paper investigates the optimum fiber reinforcement for prestressed concrete containment vessels (PCCVs) under internal pressure. To achieve this aim, steel fiber, which is the most widely used fiber type in current engineering applications, is adopted to constitute steel fiber-reinforced concrete (SFRC) to substitute the conventional concrete in the PCCV. The effects of characteristic parameters, 𝜆sf, of the steel fiber affecting significantly the mechanical behavior of the concrete are first taken into account. Partial or complete concrete regions of the PCCV are also considered to be replaced by SFRC to balance the economy and safety. By adopting the ABAQUS software, the ultimate bearing capacity and performance for the fiber-reinforced PCCV are scientifically studied and quantified, and the recommendations for the optimum way of fiber reinforcement are presented.

5단계 가압 맥파측정에 의한 연령별 혈관 경화도 분석 (Analysis of Arterial Stiffness by Age Using Pulse Waveform Measurement of 5-levels Graded Pressure)

  • 권선민;강희정;임윤경;이용흠
    • Korean Journal of Acupuncture
    • /
    • 제27권2호
    • /
    • pp.107-120
    • /
    • 2010
  • Objectives : The aim of this study is to measure pulse waveforms by applying 5-level graded pressure, and selecting optimum pulse waveforms. Also to proposing the possibility of using AW(Area of the 1/3 upper height of h1) rate in respect to AT(Total Area) for risk assessment of hypertension or arteriosclerosis is another aim of the study. Methods : Pulse waveforms of normotensive were measured by 5-level graded pressure. The pulse waveforms well reflecting properties of blood vessel(having the largest h1) were selected for optimum pulse waveforms. Various parameters(h-parameter, t-parameter, and others) of optimum pulse waveforms were analyzed. AIx(Augmentation index) was calculated by height-parameters to assess arterial stiffness. The area rate of the 1/3 upper height for h1 in respect to total area was analyzed according to aging. Results : According to aging 1. in height-parameter, h2 and h3 were increased but h5 was decreased. 2. In time-parameter, t2, t3, and t5 were getting short. 3. Area of systolic period was increased, and that of diastolic period decreased. 4. AIx rose by aging. 5. AW was significantly increased despite no changes in AT. Conclusions : By analyzing optimum pulse waveforms of 5-level graded pressure method, we could complement weakness of single graded pressure method. Also, possibility of applying the AW rate to risk assessment of hypertension or arteriosclerosis was confirmed in normotensive population which might not be assessed by AIx.

OPTIMUM AIR PRESSURE FOR AN AIR-CELL SEAT TO ENHANCE RIDE COMFORT

  • YOO W. S.;PARK D. W.;KIM M. S.;HONG K. S.
    • International Journal of Automotive Technology
    • /
    • 제6권3호
    • /
    • pp.251-257
    • /
    • 2005
  • Several air cells are installed in the seat cushion to adjust the stiffness of seat by changing the air pressure. To select proper air pressure in the air cells, two kinds of tests are performed. For the pressure distribution on the seat, the maximum pressure and mean pressure are compared. And for the dynamic ride values, SEAT (Seat Effective Amplitude Transmissibility) values are calculated and compared. These experiments are carried out with three different drivers, three different vehicle speeds on the highway and two different speed on the primary road, and three different air pressures. From the real car tests, optimum air cell pressure depending on the vehicle speed and driver's weight are recommended.

발포금속을 삽입한 밀집형 열교환기 최적 설계 (Optimum Design of a Compact Heat Exchanger with Foam Metal Insertion)

  • 이대영;진재식;강병하
    • 설비공학논문집
    • /
    • 제13권7호
    • /
    • pp.612-620
    • /
    • 2001
  • The optimum design of a heat exchanger with porous media insertion is studied in this paper. It is considered that the aluminum foam metal is inserted in a flat plate channel and air flows through it. The influence of the microstructure of the foam metal on the pressure drop and heat transfer is investigated utilizing previous analytical results and existing correlation equations. Design parameters are identified as the unit-cell size and the ligament thickness of the porous medium, and their effects are examined. The results show that there exists optimum microstructure of the porous media maximizing heat transfer with a constant pressure drop. When the increase in the pressure drop is within a practically acceptable range, the increase in the heat transfer is dominated by the increase in the heat transfer area due to the porous medium insertion. Consequently, among the porous media with a constant pressure drop, the heat transfer is maximized with a microstructure with maximum specific surface area.

  • PDF

국산 SPS5 스프링강의 마찰용접에 관한 연구 (A Study on Friction Welding of Localized SPS5 Spring Steel)

  • 정순억
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 춘계학술대회논문집A
    • /
    • pp.803-808
    • /
    • 2000
  • This thesis studied whether friction welding of SPSS, localized torsion bar material could be accomplished or not. And then optimum welding conditions were examined and leaded through tensile, impact, torsion and hardness test after postweld heat treatment of the actual field condition. Obtained results were as follows; Linear relationship was existed between heating time and total upset, and a quadratic equation model could be made between tensile strength and heating time. Optimum welding conditions with fine structure were as follows in case total upset(U)=8.5mm; the number of rotations(n)=2,000 rpm, heating pressure($p_1$)=80MPa, upset pressure($p_2$)=200MPa, heating time($t_1$)=4sec, upset time($t_2$)=3 sec.

  • PDF

H2O/(LiBr+CaCl2) 3성분계 흡수용액의 용해도 및 증기압 특성 평가 (Evaluation on solubility and vapor pressure of H2O/(LiBr+CaCl2) solution as a working fluid)

  • 노상용;장영훈;구기갑;정시영;김용원;김수경
    • 설비공학논문집
    • /
    • 제9권2호
    • /
    • pp.163-170
    • /
    • 1997
  • Solubility on $(LiBr+CaCl_2)$ in water has been measured systematically and compared with those of pure LiBr. It has been observed that there exists optimum value of $CaCl_2(LiBr+CaCl_2)$ in solubility when total$(LiBr+CaCl_2)$ concentration is higher than 57wt%. As total concentration increases up to 65wt%, it is found that the optimum value also increases monotonically. From the experimental results, a master plot has been constructed, with which optimum ratio of LiBr to $CaCl_2$ can be found in terms of total concentration. Vapor pressure of $H_2O/(LiBr+CaCl_2)$ solution with optimum contents of $CaCl_2$ has been observed to be changed negligibly at relatiely low temperature. However, as temperature increases, it is found that increasement in vapor pressure is significant.

  • PDF

점성토의 회복탄성계수($M_r$)에 대한 포화도의 영향 (Effect of Saturation on Resilient Modulus of Cohesive soils as subgrade)

  • 김동규
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1140-1147
    • /
    • 2005
  • The objective of this study was to identify the effect of the degree of saturation on the resilient modulus of cohesive soils as subgrade. Six representative cohesive soils representing A-4, A-6, and A-7-6 soil types collected from road construction sites across Ohio, were tested in the laboratory to determine their basic engineering properties. Resilient modulus tests were conducted on unsaturated cohesive soils at optimum moisture content, and samples compacted to optimum conditions but allowed to fully saturate. The subgrade compacted at optimum moisture content may be fully saturated due to seasonal change. Laboratory tests on fully saturated cohesive soils showed that the resilient modulus of saturated soils decreased to less than half that of soil specimens tested at optimum moisture content. The reduction of resilient modulus would possibly be caused by the buildup of pore water pressure. In resilient modulus testing performed in this study on saturated samples, pore water pressure increases were observed. Pore water pressure and residual pore water pressure gradually increased with an increase in deviator stress.

  • PDF