• Title/Summary/Keyword: optimum operation

Search Result 1,185, Processing Time 0.024 seconds

Effect of Water-Back-Flushing Time on Recovery Efficiency in Ceramic Filtration System for Paper Wastewater Treatment (세라믹 여과 시스템으로 제지폐수 처리시 회수 효율에 대한 물 역세척 시간의 영향)

  • Park Jin Yong
    • Membrane Journal
    • /
    • v.14 no.4
    • /
    • pp.329-338
    • /
    • 2004
  • In this study the discharged wastewater from paper manufacturing plant was filtrated by 4 kinds of tubular ceramic microfiltration and ultrafiltration membranes (carbon material) with periodic water-back-flushing, and we tried to find the optimum back-flushing time (BT). As results of water-BT effect for each ceramic membrane, the longer BT was more effective for a membrane having the larger pore size. And we could acquire the most volume of total permeate and the highest recovery efficiency of purified water, Then, the results of permeate flux vs. initial permeate flux during 180 min's operation showed that the longer BT was more effective for longer filtration time (FT) to obtain the higher permeate flux because membrane fouling proceeded deeply at long FT condition. And the optimum BT that founded from the trends of membrane fouling resistances almost accorded with the optimum BT from the trends of permeate flux, too.

Inactivation of Ralstonia Solanacearum Using Aquatic Plasma Process (수중 Plasma 공정을 이용한 Ralstonia Solanacearum 불활성화)

  • Back, Sang-Eun;Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.21 no.7
    • /
    • pp.797-804
    • /
    • 2012
  • A dielectric barrier discharge (DBD) plasma reactor was investigated for the inactivation of Ralstonia Solanacearum which causes bacterial wilt in aquiculture. The DBD plasma reactor of this study was divided into power supply unit, gas supply unit and plasma reactor. The plasma reactor consisted of a quartz dielectric tube, discharge electrode (inner) and ground electrode (outer). The experimental results showed that the optimum 1st voltage, 2nd voltage, air flow rate and pH were for 100 V (1st voltage), 15 kV (2nd voltage), 4 L/min, and pH 3, respectively. At a low 1st voltage, shoulder and tailing off phenomena was observed. The shoulder phenomenon was decreased as the increase of 1st voltage. R. Solanacearum disinfection in the lower air flow rate was showed shoulder and tailing off phenomenon because the active species generated less. Under optimum condition, shoulder and tailing off phenomenon was reduced. When the 2nd voltage was less than 7.5 kV, tailing off phenomenon was observed and this was not vanishes even though the increase of the disinfection time. The inactivation efficiency increased as the increase of air flow rate, however, the efficiency decreased when the air flow rate was above 4 L/min. R. Solanacearum disinfection at pH 3 showed somewhat higher than in pH 11. The pH effect of R. Solanacearum deactivation is less than the impact on other factor.

Evaluation of the Septic Tank Performance in the Sewage Treatment Area and Suggestion of an Optimum Model (하수처리구역내 단독정화조의 성능평가 및 최적 모형의 제안)

  • Lim, Bong-Su;Jung, Keum-Hee;Wang, Ze-Jie
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.403-409
    • /
    • 2007
  • This study was carried out to recommend the systematic improving practice for the effective operation of septic tank, and the evaluation of its BOD and nutrient removal efficiency depending on process, the survey of characteristics of FRP material, and the suggestion of optimum septic tank model within sewage treatment area. The average BOD concentration and BOD removal efficiency of septic tank which was carried out the cleaning periodically in 63.9 mg/L and 77.8%, shows good quality better than the septic tank which was not carried out the cleaning regularly. Maximum load of tensile, flexural and compressive strength increased in proportion to its thickness, and the contents standard 25% of glass fiber required upgrade over than 30%. Configuration and performance for the optimum of the septic tank suggests that over $0.75m^3$ of the effective total volume, adding to over $0.25m^3$ a man for more than 5 men of the treated person, retention time should be within one day. Improving plans about facility and materials quality of the septic tank have an obligation that protective wall ought to install on the concrete bottom and side faces to prevent crumble or transform from loading of the ground or upper part of the structure on the tank setting. And it is eliminated the uneffective resisting pressure and it keeps off circulate imperfect products by strengthening of the test methods such as stretching strength, pressing strength, glass fiber contents and thickness.

Design of Optimum Structure for Search Synchronization in a DSSS Modem for eSeal (eSeal용 DSSS 방식 모뎀의 동기 탐색 최적 구조 설계)

  • Myong, Seung-Il;Lee, Heyung-Sub;Park, Hyung-Rae;Seo, Dong-Sun
    • Journal of IKEEE
    • /
    • v.12 no.2
    • /
    • pp.95-101
    • /
    • 2008
  • In this paper, we study an optimum design of search synchronization structure for Baseband Modem to support ISO/IEC 18185-5 and 24730-2 Standard. For DSSS Modem, we design the code acquisition and tracking structure which are important in receiver operation, and examine the parameters to be considered. The data and PN chip transmission rates and processing gain of the proposed modem are 59.7 kbps, 30.521875 Mcps, and 27 dB, respectively. This indicates that the noise immunity of the proposed modem is 17dB better than IEEE 802.11b (Processing gain : 10dB). Therefore, we design the optimum structure for the modem search synchronization which is compatible to the proposed modem standard.

  • PDF

Characteristic of Oxidants Production and Dye Degradation with Operation Parameters of Electrochemical Process (전기화학적 공정의 운전인자에 따른 산화제 생성과 염료 분해 특성)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Environmental Science International
    • /
    • v.18 no.11
    • /
    • pp.1235-1245
    • /
    • 2009
  • The purpose of this study is to investigate electro-generation of free Cl, $ClO_2$, $H_2O_2$ and $O_3$ and degradation of Rhodamine B in solution using Ru-Sn-Sb electrode. Electrolysis was performed in one-compartment reactor using a dimensionally stable anode(DSA) of Ru-Sn-Sb/Ti as the working electrode. The effect of applied current (0.5-3 A), electrolyte type (NaCl, KCl, HCl, $Na_2SO_4$ and $H_2SO_4$) and concentration (0.5-2.5 g/L), air flow rate (0-3 L/min) and solution pH (3-11) was evaluated. Experimental results showed that concentration of 4 oxidants was increased with increase of applied current, however optimum current for RhB degradation was 2 A. The generated oxidant concentration and RhB degradation of the of Cl type-electrolyte was higher than that of the sulfate type. The oxidant concentration was increased with increase of NaCl concentration and optimum NaCl dosage for RhB degradation was 1.75 g/L. Optimum air flow rate for the oxidants generation and RhB degradation was 2 L/min. $ClO_2$ and $H_2O_2$ generation was decreased with the increase of pH, whereas free Cl and $O_3$ was not affected by pH. RhB degradation was increase with the pH decrease.

A Study on Proper Fenton Oxidation Conditions for Pretreatment of Livestock Wastewater (축산폐수 전처리를 위한 펜톤산화 적정조건에 관한 연구)

  • Kim, Jong Oh;Jeong, Seong Uk
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.13 no.4
    • /
    • pp.107-117
    • /
    • 2005
  • The objective of this study was to investigate the proper operation conditions of fenton oxidation such as initial pH, $H_2O_2/Fe^{2+}$ ratio, $H_2O_2/Fe^{2+}$ dosage amount, and neutralizing agent for pretreatment of the livestock wastewater. Fenton oxidation reagents were reacted with the livestock wastewater for 2 hours at 120 rpm and the settling was performed for 2 hours using jar-tester apparatus under the different experimental conditions. And then the supernatant was sampled and measured for the residual $H_2O_2$, $COD_{Cr}$, and SS. The results are as follows; optimum initial pH=4, optimum $H_2O_2/Fe^{2+}$ ratio=10:1, optimum $H_2O_2/Fe^{2+}$ dosage amount=5,000/500 mg/L and $Ca(OH)_2$ as proper neutralizing agent. The removal efficiency of $COD_{Cr}$ and SS were 43% and 84% under those optimal fenton oxidation conditions.

  • PDF

Development of a Hot Water Boiler System with a Rice Hull Furnace (왕겨 연소기(燃燒機)를 이용(利用)한 온수(溫水)보일러 시스템 개발(開發) (I) -실험적(實驗的) 연구(硏究)-)

  • Lee, Y.K.;Park, S.J.;Baek, P.K.;Noh, S.H.
    • Journal of Biosystems Engineering
    • /
    • v.12 no.4
    • /
    • pp.31-43
    • /
    • 1987
  • This study was performed to develop a hot water boiler system with small scale automatic rice hull furnace for the multi-purpose use in the farm. For the experiment a prototype hot water boiler system with rice hull furnace was fabricated, which was equipped with automatic hull feeder, igniter and ash removal device. Optimum operational conditions of the prototype: system were analyzed. The results arc summarized as follows. 1. The temperature measured right above the burning surface should be higher than $500^{\circ}C$ combustion. 2. The top zone of the combustion chamber was the most suitable location of the thermocouple to pick up the control temperature for the automatic operation of the rice hull furnace. 3. The content of carbon monoxide in the flue gas was increased with the filling height of burning material but it was less than 0.3 percent in volume in this experiment. When the filling height was expressed as the ratio of rice hull feed rate to the volume of the combustion chamber above the burning surface, the optimum ratio was about $150kg/m^3-h$. 4. The combustion efficiency of the prototype was higher than 95 percent when the feed rate was 1.1 to 2.3 kg/h and moisture content of rice hull was 22.4 percent (w.b.) or less. 5. It was estimated that the optimum operational conditions of the system were 1.3 to 2.0 kg/h in feed rate, 70 to 100 percent in excess air and 500 to $510^{\circ}C$ in control temperature. 6. The efficiency of coil heal exchanger increased with a decrease in feed rate of rice hull. When the rice hull feed rates were 1.1, 1.7 and 2.3 kg/h, the efficiencies of coil heat exchanger were about 34, 30 and 25 percent and heat transfer rates were 5.7, 7.6 and 8.8 MJ/h, respectively. When the flat plate heat exchanger was used in addition to the coil heat exchanger, the efficiency of the heat exchanger system increased to 48 percent.

  • PDF

Optimization of Drying and Storage System for Paddy Using the Grain Cooler (곡물냉각기를 이용한 벼 건조 및 저장시스템의 최적화)

  • 김동철;김의웅
    • Food Science and Preservation
    • /
    • v.11 no.2
    • /
    • pp.269-275
    • /
    • 2004
  • This study was conducted to develop an optimization model using Box's Complex Algorithm, and to determine optimum operating conditions to minimize costs for the drying and storage system using the grain cooler. To minimize the system operation cost, the optimum moisture contents after the first drying were found to be from 17.2 to 19.8 %. And optimum drying and cooling capacities were obtained. The combination of the dryer and grain cooler was found to be economical, showing enhancement of the drying capacity over 50%, and decrease of drying cost over 10%. When the circulating grain dryers of 6 and 20 ton/batch were used in conjunction with the grain cooler, the cost required for drying and storage system for paddy were 28,464∼33,317won/ton and 20,588∼26,511 won/ton, respectively, which was from 2.6 to 27.3% lower than that of conventional drying and storage system.

A Heuristic Technique for Generating the Synchronizable and Optimized Conformance Test Sequences (최적화된 동기적 적합성시험 항목의 발견적 생성 방법)

  • Kim, Chul
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.8 no.6
    • /
    • pp.470-477
    • /
    • 2015
  • This paper presents a new technique for generating an optimum synchronizable test sequence that can be applied in the distributed test architecture where both external synchronization and input/output operation costs are taken into consideration. The method defines a set of phases that constructs a tester-related digraph from a given finite state machine representation of a protocol specification such that a minimum cost tour of the digraph with intrinsically synchronizable transfer sequences can be used to generate an optimum synchronizable test sequence using synchronizable state identification sequences as the state recognition sequence for each state of the given finite state machine. This hybrid approach with a heuristic and optimization technique provides a simple and elegant solution to the synchronization problem that arises during the application of a predetermined test sequence in some protocol test architectures that utilize remote testers.

Media Optimization and Comparison of Fermentation Type for Overproduction of Staphylodinase in Bacillus subtilis WB700 (Bacillus Subtilis W700에서의 Staphylpkinase 대량생산을 위한 배지 최적화 및 배양방법의 비교)

  • 박인석;김병기
    • KSBB Journal
    • /
    • v.16 no.4
    • /
    • pp.415-419
    • /
    • 2001
  • To produce staphylokinase (SAK) in B. subtilis WB700, media optimization was carried out and the operation of batch and fed-batch fermentation were compared. Tryptone is a good nitrogen source and its optimum concentration in modified super rich(MSR) media is 15 g/L. When glucose is used as a limiting carbon source in the MSR media, 5 g/L of an optimum glucose concentration was identified for the SAK production under the control of P43 promoter. As the expression of P43 promoter is controlled by the limitation of oxygen, the SAK production was controlled at the 30% DO level in the fed-batch fermentation. Unexpectedly, batch fermentation using MSR media showed 1.5 times higher yield of SAK than that of the fed-batch fermentation. The main cause of the results comes from not achieving higher cell concentration in the fed-batch fermentation and the optimum expression level of P43 promoter under oxygen or nutrient limitations. We could not achieve the increase in cell concentration by any means in batch culture as well as fed-batch culture. The highest yield in the batch culture was 2880 units of SAK activity and 455 mg/L of secreted SAK.

  • PDF