• Title/Summary/Keyword: optimum operation

Search Result 1,183, Processing Time 0.028 seconds

Effects of ultrasound coupled with potassium permanganate pre-treatment of sludge on aerobic digestion

  • Demir, Ozlem
    • Advances in environmental research
    • /
    • v.5 no.4
    • /
    • pp.251-262
    • /
    • 2016
  • The biodegradability and decomposition efficiencies increase with the pre-treatment of sludge in a digestion process. In this study, the feasibility of ultrasound coupled with potassium permanganate oxidation as a disintegration method and digestibility of aerobic reactor fed with disintegrated sludge with ultrasound coupled potassium permanganate were investigated. The first stage of the study focused on determining the optimum condition for ultrasonic pre-treatment for achieving better destruction efficiency of sludge. The second part of the study, the aerobic digestibility of sludge disintegrated with ultrasound and potassium permanganate oxidation alone and combined were examined comparatively. The results showed that when 20 min of ultrasonic pre-treatment applied, the specific energy output was 49384 kJ/kgTS with disintegration degree of 58.84%. During the operation of aerobic digester, VS/TS ratios of digesters fed with disintegrated sludge decreased indicating that disintegration methods could obviously enhance aerobic digestion performance. The highest reduction in volatile solids was 75% in the digester fed with ultrasound+potassium permanganate disintegrated sludge at the end of the operation compared to digester fed with raw sludge. Total Nitrogen (TN) and Total Phosphorus (TP) levels in sludge supernatant increased with this combined method significantly. Besides, it promoted the production of ${\bullet}OH$, thus enhancing the release of Carbon (C), Nitrogen (N) and Phosphorus (P) from the sludge. Disintegration with all methods used in this study could not improve Capillary Suction Time (CST) reduction in disintegrated digesters during the operation. The results demonstrated that the combined ultrasound treatment and potassium permanganate oxidation method improves the biodegradability compared to control reactor or their single application.

A Study on the Optimum Design of Charge Pump PLL with Dual Phase Frequency Detectors (두 개의 Frequency Detector를 가지고 있는 Charge Pump PLL 의 최적설계에 관한 연구)

  • Woo, Young-Shin;Jang, Young-Min;Sung, Man-Young
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.50 no.10
    • /
    • pp.479-485
    • /
    • 2001
  • In this paper, we introduce a charge pump phase-locked loop (PLL) architecture which employs a precharge phase frequency detector (PFD) and a sequential PFD to achieve a high frequency operation and a fast acquisition. Operation frequency is increased by using the precharge PFD when the phase difference is within $-{\pi}{\sim}{\pi}$ and acquisition time is shortened by using the sequential PFD and the increased charge pump current when the phase difference is larger than ${\pm}{\pi}$. So error detection range of the proposed PLL structure is not limited to $-{\pi}{\sim}{\pi}$ and a high frequency operation and a higher speed lock-up time can be achieved. The proposed PLL was designed using 1.5 ${\mu}m$ CMOS technology with 5V supply voltage to verify the lock in process. The proposed PLL shows successful acquisition for 200 MHz input frequency. On the other hand, the conventional PLL with the sequential PFD cannot operate at up to 160MHz. Moreover, the lock-up time is drastically reduced from 7.0 ${\mu}s\;to\;2.0\;{\mu}s$ only if the loop bandwidth to input frequency ratio is regulated by the divide-by-4 counter during the acquisition process. By virtue of this dual PFDs, the proposed PLL structure can improve the trade-off between acquisition behavior and locked behavior.

  • PDF

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

A study on the comparison of operation for long & short time in the Dranco process (건식단상혐기성소화조 장.단기 운영의 비교연구)

  • Hong, Jong-Soon;Kim, Jae-Woo;Shin, Dae-Yewn
    • Journal of environmental and Sanitary engineering
    • /
    • v.23 no.4
    • /
    • pp.73-82
    • /
    • 2008
  • In this study, a dry single-phase anaerobic digestion process (Dranco system) was investigated to evaluate the optimum operational conditions. Several factors such as injection rate of organic waste, biogas production, $CH_4$ content in the biogas, pH of the sludge, $NH_3$-N and VFA concentration were investigated based on the operation of the digestion process for 2 months (short term) and 8 months (long-term). The operation results showed that a small quantity of food waste should be injected every week and that a 10% increase of the microorganism injection rate should be needed. However, normal operation was conducted after 11 weeks based on the designed quantity. The $CH_4$ content in the biogas was high at the beginning and the end of the food injection. However, it was low during week days. When the biogas production was high, the $CH_4$ concentration was low. The biogas production increased with an increase of the injection rate. $100m^3$/ton of biogas was produced from normal operation of the digestion process based on the designed quantity. The pH values of the digestion tank based on short-term operation ranged from 8 to 8.5. However, the pH values ranged from 7.45 to 8.15 after 4 weeks of long-term operation. The $NH_3$-N concentration of short-term operation ranged from 4,500 to 5,500 ppm and it gradually decreased to 2,000ppm after normal operation was commenced. For long-term operation, it was 5,000ppm initially and 3,800ppm after normal operation was commenced. The VFA concentration of sludge was less than 900ppm and 2,500ppm for short and long-term operations, respectively, after normal operation. Overall, the differences between sludge pH, $NH_3$-N and VFA concentrations may be due to the different types of microorganisms and the digestion ability of the microorganisms which exist in the accumulation of non digested organics. Moreover, it may be also caused by the type of food waste. Further investigation is needed to confirm these relationships.

A Pilot-Scale Microfiltration/Ultrafiltration system for Drinking Water Treatment (상수처리를 위한 파일롯 규모의 정밀여과/한외여과 시스템)

  • Kim, Hanseung;Oh, Jeongik;Kim, Chunghwan
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.6
    • /
    • pp.770-777
    • /
    • 2004
  • Three pilot-scale membrane systems were operated using lake water as influent in this study. Microfiltration (MF) membrane with pore size of 0.01 m was used in Systen I of which filtration mode was set at constant pressure of $1kgf/cm^2$. Ultrafiltration (UF) membranes with molecular cutoff (MWCO) of 80,000 and 13,000 were used in System II-1 and II-2, respectively. Constant flow mode was applied at the range between 0.7 and $1.5m^3/m^2{\cdot}d$ (average of $1.1m^3/m^2${\cdot}d) for System II-1 and between 0.37 and $1.65m^3/m^2{\cdot}d$ (average of $1.18m^3/m^2{\cdot}d$) for System II-2. In System I, the flux changed from $1m^3/m^2{\cdot}d$ to $0.2m^3/m^2{\cdot}d$ during the operation time of 5 months. System II showed recovery of 94% under the allowable maximum pressure of $3kgf/cm^2$ during the same operation period. From these results, the efficient operation was observed in constant flow mode with respect to filtration time and recovery. Average filtrate turbidity showed 0.0071 NTU in System I and 0.0054 NTU in System II, which implied that high turbidity removal was obtained in both MF and UF systems with no significant difference between MF and UF. From the fact that membrane flux depends largely on membrane type and operation mode, a guideline of optimum design and operation should be suggested for application of membrane systems to full scale water treatment.

Study on the Optimum Route Travel Time for Bus to Improve Bus Schedule Reliability (정시성 확보를 위한 버스노선 당 적정 운행시간 산정 연구)

  • Kim, Min ju;Lee, Young ihn
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.16 no.6
    • /
    • pp.112-123
    • /
    • 2017
  • The accurate forecasting of the public transportation's transit and arrival time has become increasingly important as more people use buses and subways instead of personal vehicles under the government's public transportation promotion policy. Using bus management system (BMS) data, which provide information on the real-time bus location, operation interval, and operation history, it is now possible to analyze the bus schedule reliability. However, the punctuality should always be considered together with the operation safety. Therefore, this study suggests a new methodology to secure both reliability and safety using the BMS data. Unlike other studies, we calculated the bus travel time between two bus stops by dividing the total travel length into 6 sections using 5 different measuring points. In addition, the optimal travel time for each bus route was proposed by analyzing the mean, standard deviation and coefficient of variation of the each section's measurement. This will ensure the reliability, safety and mobility of the bus operation.

Characteristics of Lactose Hydrolysis by Immobilized β-Galactosidase on Chitosan Bead (Chitosan 담체에 고정화된 β-galactosidase에 의한 유당 분해 특성)

  • Kang, Byung-Chul
    • Journal of Life Science
    • /
    • v.21 no.1
    • /
    • pp.127-133
    • /
    • 2011
  • ${\beta}$-Galactosidase was immobilized on chitosan bead by covalent bonding using glutaraldehyde. The characteristics of the immobilized enzyme were investigated. Maximum immobilization yield of 75% was obtained on chitosan bead. Optimum pH and temperature for the immobilized enzyme was 7.0 and $50^{\circ}C$, respectively. The immobilized enzyme showed a broader range of pH and temperature compared to a free one. A mathematical model for the operation of the immobilized enzyme in a packed-bed reactor was established and solved numerically. Under different inlet lactose concentrations and feed flow rate conditions, lactose conversion was measured in a packed-bed reactor. The experimental results of continuous operation in a packed-bed reactor were compared to theoretic results using Michaelis-Menten kinetics with competitive product inhibition and external mass transfer resistance. The model predicted the experimental data with errors less than 5%. Process optimization of continuous operation in a packed-bed reactor was also conducted. In a recirculation packed-bed operation, conversion of lactose was 97% in 3 hours. In a continuous packed-bed operation, the effect of flow rate and initial lactose concentration was investigated. Increasing flow rates and initial lactose concentration decreased the conversion of substrate.

Theoretical approach on the heating and cooling system design for an effective operation of Li-ion batteries for electric vehicles (전기구동 자동차용 리튬이온 배터리의 고효율 운전을 위한 냉방 및 난방 시스템 설계에 대한 이론적 접근법)

  • Kim, Dae-Wan;Lee, Moo-Yeon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.5
    • /
    • pp.2545-2552
    • /
    • 2014
  • This study is aiming to suggest the effective thermal management system design technologies for the high voltage and capacity battery system of the electricity driven vehicles and introduce the theoretical designing methods. In order to investigate the effective operation of the battery system for the electricity driven vehicles, the heat generation model for Li-ion battery system using the chemical reaction while charging and discharging was suggested and the thermal loads of the heat sources (air or liquid) for cooling and heating were calculated using energy balance. Especially, the design methods for the cooling and heating of the battery system for maintaining the optimum operation temperature were investigated under heating, cooling and generated heat (during charging and discharging) conditions. The battery thermal management system for the effective battery operation of the electricity driven vehicles was suggested reasonably depending on the variation of the season and operation conditions. In addition, at the same conditions under summer season, the cooling method using the liquid and active cooling technique showed a relatively high capacity, while cooling method using the passive cooling technique showed a relatively low capacity.

Stochastic Generation Model Development for Optimum Reservoir Operation of Water Distribution System (저수지 최적운영모형을 위한 추계학적 모의 발생 모형의 유도)

  • Kim, Tae Geun;Yoon, Yong Nam;Kim, Joong Hoon
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.14 no.4
    • /
    • pp.887-896
    • /
    • 1994
  • It is common practice in the case of optimum reservoir operation model that the reservoir inflow series are generated by stochastic model with keeping other variable such as water demands from the reservoir constant. However, when the input and output of the water distribution system have close relationship the output variables can be stochastically generated in relation with the input variables. In the present study the reservoir inflow series, the input of the system, is generated by periodic autoregressive model with constant parameter, and the agricultural water demand series, the output, is generated using periodic multivariate autoregressive model with constant parameter. The time period of the data series generated is taken as 10-day which is the common period used for agricultural water uses. The results of data generation by two different models showed that the periodic stochastic models well represent the characteristics of the historical time series, and that in the case of generating model for agricultural demand series it has closer relation with reservoir inflow than with the series itself.

  • PDF

A Study on the Biosorption Process for Organic and Nutrient Removal from the Wastewater (생흡착을 이용한 하수의 유기물, 질소, 인제거에 관한 연구)

  • Kim, Hyun-Kab;Park, Ju-Seok;Chung, Hyung-Keun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.4
    • /
    • pp.470-479
    • /
    • 2004
  • The experimental conditions and relationships between parameters such as organic matter, aeration volume, aeration time, and precipitation time for the effective treatment of domestic wastewater were investigated. With the batch systems, the adsorption amount of unit microbe was measured with the change of MLSS concentration, precipitation time, and aeration amount. Theoretical adsorption amount of microbes was then numerically formulated by use of a SPSS multiple analysis as follows: $$Y=-0.0106(X_1)+0.07310(X_2)+42.705(X_3)+62.700$$ In this study, the amount of organisms to be removed in the range of MLSS concentration 2,000~4,500 mg/l were examined. In order to investigate the optimal condition of nitrification, the upper water in the biosorption stage was used as the initial experiment water. The results showed that the C/N ratio was 1.5 and the reaction time for the optimal nitrification was 1.5 hr. When the adsorption efficiency for microbe biosorption was 66%, the optimum denitrification efficiency was 83.3%. When the optimum parameters obtained from the batch experiment were applied to the lab-scale operation, the total retention time from the flow-in to flow-out was 10 hours and the removal efficiency was 93.8% for $COD_{cr}$ and 80.9% for TN. For the full-scale operation, the total retention time was 9.0 hours and the removal efficiency was 94.4% for BOD, 89.6% for $COD_{cr}$, 88.0% for TN, and 86.2% for TP.