• Title/Summary/Keyword: optimum operation

Search Result 1,185, Processing Time 0.029 seconds

Optimum Layout Model of Lift Car for Improving Productivity in High-rise Building Exterior Finishing Work (마감공사 생산성 향상을 위한 리프트 카 최적배치 모델)

  • Lee, Dongmin;Lim, Hyunsu;Kim, Taehoon;Cho, Hunhee;Kang, Kyung-In
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2013.05a
    • /
    • pp.171-172
    • /
    • 2013
  • An operation planning of lift car is crucial in tall building construction especially it's arrangement plans, because it is related with transportation distance of finishing materials affecting construction productivity. Since tall building construction, composed of complicating and huge plane have complex traffic lines of finishing materials, to determine the position of lift car empirically or intuitively has limits. Therefore this paper suggest an optimum layout model of lift car minimizing the transportation distance both at site-level and floor-level using Graph theory and Dijkstra algorithm.

  • PDF

Demethylchlortetracycline 발효 생산에서 pH 조절의 최적화와 암모늄이온 농도의 영향

  • kim, Hyung-Soo;Kim, Sae-Jin;Lee, Young-Moo;Hwang, Hak-Youn;Choi, Nam-Hee
    • Microbiology and Biotechnology Letters
    • /
    • v.25 no.3
    • /
    • pp.317-321
    • /
    • 1997
  • The effect of ammonium ion concentration on the production of demethyl- chlortetracycline (DMCT) by a DMCT overproducing mutant, Streptomyces aureofaciens 27VR, and the optimal control of pH were studied. The optimum levels of pH control were 6.5-6.6 for 80-120 hr, 6.4- 6.5 for 121-150hr and 6.3-6.4 for 151-190hr. The optimum level of ammonium ion concentration during the pH control was lower than 20 mg%. Under the optimized culture condition, it was possible to produce DMCT with an 18% increase in productivity compared to that of standard culture condition in 190hrs of the fermentor operation.

  • PDF

A Study on the Optimum Operational Control of Power System (전렬계통의 합리적 운용제어에 관한 연구)

  • 정재길;박영문
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.33 no.10
    • /
    • pp.410-422
    • /
    • 1984
  • This paper presents a new practical method for optimal active and reactive power control for the economic operation in electrical power system, and the programs are developed for digital computer solution. The major features and techniques of this paper are as follows: 1) The method is presented for finding the equivalent active power balance equation applying the sparse Jacobian matrix of power flow equation instead of using B constant as active power balance equation considering transmission loss, and thus for determining directly optimal active power allocation berween generator unitw satisfying the equality and inequality constraints. 2) The method is proposed for solving directly the optimum economim dispatch problem without using gradient method and penalty function for both active and reactive power control. As a result, the computing time are reduced and convergence characteristic is remarkably improved. 3) Unlike most of conventional methods which adopt the transmission loss as a objective function for reactive power control, the total fuel cost of themal power plant is adopted as objective function for both active and reactive power control. consequently, more reasonable and economic profit can be achieved.

Shifting Algorithm and Response Characteristics of CVT (CVT의 변속 알고리듬과 응답특성)

  • Sung, D.H.;Kim, H.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.6
    • /
    • pp.9-17
    • /
    • 1994
  • In this study, a shifting algorithm of CVT was suggested for the two(2) driving modes : (1) power mode and (2) economy mode. Shifting algorithm must be obtained to make the engine run on the optimum operating line for the desired performance of the vehicle. Optimum operating lines of the engine were obtained by connecting the shortest way of the iso-power lines for the power mode and by connecting the shortest way of the BSFC curves for the economy mode. Also dynamic model of CVT vehicle was derived considering the throttle and the brake operation. By using the shifting algorithm and the CVT vehicle model, numerical simulations were performed to estimate the performance of CVT. Simulation results showed that comparing the performance of the conventional 4-speed automatic transmission, acceleration performance of the CVT vehicle was almost same with the AT vehicle for the power mode and the fuel economy of CVT was 14% superior than that of AT for the economy mode.

  • PDF

Investigation on Optimum Plasma Production Condition of a Magnetic Neutral Loop Discharge System (자기중성선방전 시스템의 최적 플라즈마 생성조건에 관한 고찰)

  • Sung, Youl-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.11
    • /
    • pp.2236-2241
    • /
    • 2009
  • In this study, the electron behavior was investigated numerically in order to obtain guidelines for design and operation of a new plasma source by a magnetic neutral loop discharge (NLD). The optimum plasma production was investigated by using a 3-dimensional simulation model which enables the electron behavior calculation from source region to downstream region. The results showed that the high-density plasma produced around the magnetic neutral loop (NL) is transferred from the NL region to the downstream region along magnetic force lines. Also the avaraged electron energy is increased with the normalized RF electric field (F), which can be used to characterize the plasma production efficiency of NLD system. Considering the relation between F and plasma production, in-depth plasma control can be achieved at a given specific process condition.

Continuous Production of Fructo-oligosaccharides by Immobilized Cells of Aureobasidium pullulans

  • Yun, Jong-Won;Jung, Kyung-Hoon;Jeon, Yeong-Joong;Lee, Jae-Heung
    • Journal of Microbiology and Biotechnology
    • /
    • v.2 no.2
    • /
    • pp.98-101
    • /
    • 1992
  • Continuous production of fructo-oligosaccharides employing a packed bed reactor charged with immobilized cells of Aureobasidium pullulans was investigated. The optimum conditions for reactor operation were a feed concentration of 860 g/l; a feed rate, expressed as superficial space velocity of $0.2\;h^{-1}$, and a temperature of $50^\circ{C}$. Under these optimum conditions, the productivity of the reactor was $180\;g/l\cdot{h}$. Initial activity was maintained for more than 100 days. The reactor was successfully scaled up to a production scale of 1000l.

  • PDF

Estimation of the Optimum Number of Machines and Equipments for Professional Dairy Farm (낙농 전업농의 기계장치 최적 규모 추정)

  • 유병기;이용범;장진택;이동현;권두중;기광석;성시흥;이대원
    • Journal of Animal Environmental Science
    • /
    • v.2 no.1
    • /
    • pp.27-39
    • /
    • 1996
  • A survey was conducted for dairy farmer to estimate the optimum number of machine and equipment in 1994. Labor hours, operation costs and operation methods for each dairy processing were investigated and analyzed for the farmers to find the expected numbers of machine and equipment on the basis of the desired farm scale. And also, the estimated models were compared and analyzed with the conventional models which more than half dairy farmers used bucket milker in tie stall barn. Some of the results are as follows : 1. Analysis results of conventional model showed that a dairy farm could raise to 15 heads of dairy cow with family labor of 1.5 men, labor hours of 2, 700 in you and total operation costs of 734 thousand won per head. 2. The result, used in conjunction with minimum operation costs in tie stall barn, showed that 28 dairy cows could be raised by using concentrates feeding by hoppers, water supply by water cups, milking by pipeline milker, and manure cleaning by barn cleaner with total operation costs of 520 thousands won per head. 3. The total operation costs of a loose barn system is higher than those of tie stall barn system to raise about 30 heads. For the loose barn system, the herringbone parlour was used for milking, concentrate feeding by automatic concentrate feeder, water supply by thermal insulation feeder, and manure cleaning by scraper with total operation costs of 582 thousands won per head every year.

  • PDF

A Study on the Estimating of the Dump Truck's Travel Speed Based on Analysis of Factors Affecting Earthmoving Operation (운반작업의 영향요소분석을 통한 덤프트럭의 운반속도 산정방법에 관한 연구)

  • Park, Hyeon-Yong;Tae, Yong-Ho;Woo, Sung-Kwon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.8 no.3
    • /
    • pp.97-105
    • /
    • 2007
  • In many construction projects, such as dams, highways, airports, buildings, industrial plants, and sewerage and drainage systems earthmoving operation is defined the movements of a certain quantity of earth to alter the surface configuration or conditions so that projects requirement can be met. Accurate calculation of travel time is essential for determining productivity of earthmoving operations, and for ultimately selecting the most cost-effective fleet configuration for executing the work. Also transportation work that utilizes dump truck consists average So in the whole expenses earthmoving operation, and is an important cost factor for cost management. Therefore this study proposes a methodology for optimum transfer speen based on the analysis of factors affecting earthmoving operation in different road types by collecting the sources of dump truck running speeds and considering the main factors affecting the earthmoving operation.

Continuous Production of Fructooligosaccharides Using Fructosyltransferase Immobilized on Ion Exchange Resin

  • Yun, Jong-Won;Song, Seung-Koo
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.1 no.1
    • /
    • pp.18-21
    • /
    • 1996
  • A continuous production of fructooligosaccharides from sucrose was investigated by fructosyltransferase immobilized on a high porous resin, Diaion HPA25. The optimum pH(5.5) and temperature(55$^{\circ}C$) of the enzyme for activity was unaltered by immobilization, and the immobilized enzyme became less sensitive to the pH change. The optimal operation conditions of the immobilized enzyme column for maximizing the productivity were as follows: 600g/L of sucrose feed concentration, flow rate of superficial space velocity 2.7h-1. When the enzyme column was run at 50$^{\circ}C$, about 8% loss of the initial activity of immobilized enzyme was observed after 30 days of continuous operation, during which high productivity of 1174g/L$.$h was achieved. The kinds of products obtained using the immobilized enzyme were almost the same as those using soluble enzymes or free cells.

  • PDF

Economical Evaluation Based on Method of Coagulation with GAC Adsorber Operation (활성탄 흡착지의 운영시 응집 방법에 따른 경제성 평가)

  • Hong, Seongho;Sung, Dae-Hyun
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.473-479
    • /
    • 2005
  • Applying enhanced coagulation is not uncommon not only to improve water quality but also to obtain economical advantages in water treatment. In this study, the economical evaluation was investigated with considering dosage of coagulant, produced sludges and usage of activated carbon with two different water sources. To simulate the granular activated carbon(GAC) adsorber mini-column test was adapted. Even if there were some variation according to the source waters, the life time of GAC was extended 60 to 110days with adding 2.5 to 3 times of coagulant in enhanced coagulation. With assumption of changing GAC adsorber at 50% of breakthrough the total treatment cost can be reduced to range from 25% to 44% with adapting the enhanced coagulation. The obtained value can not be generalized because the value can be varied by water quality and cost of the GAC or coagulant. However, the evaluation can be basis starting point to find optimum operation methods for the drinking water treatment which has plan to adapt GAC adsorber.