• Title/Summary/Keyword: optimum mix-proportion

검색결과 73건 처리시간 0.028초

A Study on the Optimum Mix Proportion of the Stabilizing Liquid Used for Excavation of the Deep and Massive Slurry Wall

  • Kwon Yeong-Ho
    • KCI Concrete Journal
    • /
    • 제14권4호
    • /
    • pp.151-159
    • /
    • 2002
  • This study investigates experimentally the optimum mix proportion and design factors of the stabilizing liquid used for excavation of the massive and deep slurry wall in LNG in-ground tank before pouring concrete. Considering those site conditions, the stabilizing liquid used for excavation of slurry wall has to be satisfied with some requirements including specific gravity, fluid loss, cake thickness, funnel viscosity and sand content in order to construct the safe and qualified slurry wall. For this purpose, we select materials including bentonite, polymer and dispersion agent. After performing many tests for materials and mix design process, we propose the optimum mix proportion that the upper limit ratio of bentonite is $2.0\%$, polymer is $0.1\%$ considering the funnel viscosity and dispersion agent is $0.05\%$considering the fluid loss of the stabilizing liquid. Also, we select all materials which are consisted of GTC4 as bentonite, KSTP as polymer and Bentocryl 86 as dispersion agent. Based on the results of this study, the optimum mix proportion of the stabilizing liquid is applicable to excavate the deep and massive slurry wall in LNG in-ground tank successfully.

  • PDF

데이터베이스의 영역 특성을 고려한 콘크리트 최적 배합 선정 기법 (Optimum Technique for Concrete Mix-proportion Considering the Region Characteristics of Database)

  • 이방연;김재홍;김진근
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 춘계 학술발표회 논문집(II)
    • /
    • pp.621-624
    • /
    • 2006
  • This paper presents a novel optimum technique for optimum mix-proportion using database-based prediction model of material properties for an object function or a constraint condition. The proposed technique provides high reliability of results introducing effective region model, which assesses whether the prediction model is effective or not, in optimization process. In order to validate the proposed technique, a genetic algorithm was adopted as a optimum technique, and an artificial neural network was adopted as a prediction model for material properties and as a model for assessing effective region. The mix-proportion obtained from the proposed technique is more reasonable than that obtained from a general optimum technique.

  • PDF

최대밀도이론을 이용한 아스팔트 혼합물의 배합설계에 관한 연구 (The Study of Asphalt Concrete Mixture Design Using Maximum Density Theory)

  • 이승한;박현묘;정용욱;장석수;김장욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.525-528
    • /
    • 2005
  • This study determines the best composite grade to minimize the void of aggregate mixture based on the maximum density theory in an attempt to suggest a mix proportion method design for asphalt mixtures. Study results show that the grading curve with the maximum mass per unit capacity of each aggregate mixture satisfied the KS standards and the optimum AP content to meet the optimal asphalt mixture void rate of 4$\%$ was 5.7$\%$, less than the optimum AP content of 6.5$\%$ suggested in the Marshal mix proportion method design. At the same time, the asphalt mixture produced based upon the suggested mix proportion method had a flow value 17$\%$ lower than that of asphalt mixture produced according to the Marshal method, while its density was greater by 0.06$\~$0.09. This suggests that the introduced mix proportion method design helps to improve the shape flexibility and crack-resistance of asphalt concrete.

  • PDF

수중에 노출된 농업용 콘크리트 구조물 보수용 라텍스개질 모르타르의 적정 배합비 도출 (Optimum Mix Proportions of Latex Modified Repair Mortar for Agricultural Underwater Concrete Structure)

  • 원종필;이재영;박찬기;이상우;김완영
    • 한국농공학회논문집
    • /
    • 제49권3호
    • /
    • pp.43-50
    • /
    • 2007
  • The purpose of this study was to determine the optimum mix proportion of latex modified mortar for agricultural underwater concrete structures repair. The experimental variables included a latex and antiwashout admixture amount, binder-sand ratio, water-binder ratio. This study were evaluated a repair performance and environment effect of latex modified repair mortar for agricultural underwater concrete structures. The pH test was conducted to evaluated the environmental effect and the flow test was peformed to evaluated the workability. Also, compressive, flexural and bond tests were conducted. Test results show that the optimum mix proportion of latex modified repair mortar for agricultural underwater concrete structures, was achieved by 1:1.5 binder-sand ratio, 5% latex ratio (weight of binder), 1.3% antiwashout admixture ratio (weight of binder), 0.33 water-binder ratio and 10% silica lune replacement ratio (weight of cement). The environmental effect and repair performance of optimum mix proportion satisfied all target performance.

순환골재를 이용한 콘크리트의 배합설계에 관한 연구 (A Study on Design of Mix Proportion for Concrete using Recycled Aggregate)

  • 박원준;노구치 타카후미
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2011년도 추계 학술논문 발표대회
    • /
    • pp.101-103
    • /
    • 2011
  • Various desired performances of concrete cannot be always obtained by current conventional mix proportion methods for recycled aggregate concrete (RAC). This paper suggests a new design method of mix proportion for RAC to reduce the number of trial mixes using genetic algorithm (GA) which has been an optimization technique to solve the multi-object problem. In mix design method by GA, several fitness functions for the required properties of concrete, i.e., slump, strength, price, and carbonation speed coefficient were considered based on conventional data or fitness function. As a result, various optimum mix proportions for RAC that meet required performances were obtained and the risk evaluation was also conducted for selected mixtures.

  • PDF

병용계 고유동 콘크리트의 배합요인에 따른 특성 (Properties of the Combined High Flowing Concrete by Mix Design Factors)

  • 권영호;이현호;이화진;하재담
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 추계 학술발표회 제17권2호
    • /
    • pp.407-410
    • /
    • 2005
  • This research investigates experimentally an effect on the properties of the combined high flowing concrete by mix design factors. The purpose of this study is to determine the optimum mix proportion of the combined high flowing concrete having good flowability, viscosity, no-segregation and design strength(40.0MPa). For this purpose, trial mixings used belite cement+lime stone powder(LSP) are tested by mix design factors including water-cement ratio($47.9\~54.0\%$), fine aggregate volume ratio($41\~45\%$) and coarse aggregate volume ratio($41\~45\%$). As test results of this study, the optimum mix proportion for the combined high flowing concrete is as followings. Water-cement ratio $51.0\%$, fine aggregate volume ratio $43{\pm}1\%$ and coarse aggregate volume ratio $0.30{\pm}0.05m^3/m^3$ and replacement ratio of LSP $42.7\%$.

  • PDF

Genetic algorithm in mix proportion design of recycled aggregate concrete

  • Park, W.J.;Noguchi, T.;Lee, H.S.
    • Computers and Concrete
    • /
    • 제11권3호
    • /
    • pp.183-199
    • /
    • 2013
  • To select a most desired mix proportion that meets required performances according to the quality of recycled aggregate, a large number of experimental works must be carried out. This paper proposed a new design method for the mix proportion of recycled aggregate concrete to reduce the number of trial mixes. Genetic algorithm is adapted for the method, which has been an optimization technique to solve the multi-criteria problem through the simulated biological evolutionary process. Fitness functions for the required properties of concrete such as slump, density, strength, elastic modulus, carbonation resistance, price and carbon dioxide emission were developed based on statistical analysis on conventional data or adapted from various early studies. Then these fitness functions were applied in the genetic algorithm. As a result, several optimum mix proportions for recycled aggregate concrete that meets required performances were obtained.

지상식 LNG 저장탱크용 고강도 자기충전 콘크리트의 최적배합에 관한 연구 (Optimum Mix Proportion of the High Strength and Self Compacting Concrete Used Above-Ground LNG Storage Tank)

  • 권영호
    • 콘크리트학회논문집
    • /
    • 제23권1호
    • /
    • pp.99-107
    • /
    • 2011
  • 이 연구는 대용량 지상식 LNG 저장탱크에 사용할 고강도 자기충전 콘크리트의 최적배합 조건을 도출하고, 현장적용을 위한 기본 자료를 제안하기 위한 것이다. 60~80 MPa 고강도 자기충전 콘크리트를 적용하면, 벽체두께의 감소와 자기충전성에 따른 인력절감 및 품질확보 등을 통하여 경제성을 확보할 것으로 예상된다. 시멘트 및 분체는 점성 증대 및 수화열 저감에 우수한 플라이애쉬와 저열 시멘트(벨라이트)를 사용하였다. 플라이애쉬의 치환율은 구속수비 및 배합변수 실험을 통해 정하였으며, 배합변수는 단위수량(W), 플라이애쉬 치환율(FA), 물-결합재비(W/B) 및 잔골재율(S/a)로 하여, 최적배합비 및 경제성 평가를 실시하였다. 실험 결과, 설계기준강도 60 MPa의 경우에는 단위수량 165 $kg/m^3$, 플라이애쉬 치환율 20% 및 물-결합재비 27~30%로 나타났으며, 설계기준강도 80 MPa의 경우에는 단위수량 165 $kg/m^3$, 플라이애쉬 치환율 10% 및 물-결합재비 25%로 나타났다. 또한, 기존의 설계기준강도 40 MPa과 비교해 볼 때, 압축강도 증가에 따른 재료비 상승은 60 MPa의 경우 14~22% 및 80 MPa의 경우 33%로 나타나, 현장관리 및 인력절감 등과 함께 매우 경제적인 것으로 나타났다.

농업용 콘크리트 구조물을 위한 라텍스 개질 보수용 모르타르의 적정 배합비 도출 (Optimum Mix Proportion of Latex Modified Repair Mortar for Agricultural Concrete Structures)

  • 원종필;이재영;박찬기;박성기
    • 한국농공학회논문집
    • /
    • 제49권2호
    • /
    • pp.37-46
    • /
    • 2007
  • The service life of agricultural concrete structures is designed in about 30 to 100 years, but actual service lift is estimated in an average 18 years. Therefore, as the service life of the agricultural concrete structures increases, necessity of repair by aging from various environment condition exposure increases. This study was to determinate the optimum mix proportion of latex modified repair mortar and to improve the durability performance of agricultural concrete structures. The physical and mechanical tests of latex modified repair mortar were performed. Tests of flow, compressive strength, flexural strength and bond strength tests were conducted. Test results show that the optimum nex proportion of latex modified repair mortar, when used in 5% latex volume fraction (weight of cement), 1.5% antifoaming agent (weight of latex), 0.2% PVA fiber volume fraction, 1:2 (binder-sand ratio), 10% silica fume replacement ratio (weight of cement), could result in best performance for the repair of agricultural concrete structures.

고성능콘크리트의 배합설계 (Mix Design of High Performance Concrete)

  • 정용욱;이승한;윤용호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(II)
    • /
    • pp.73-76
    • /
    • 2005
  • This study aims to suggest a simple and convenient design for a mix proportion method for high performance concrete by determining the optimum fine aggregate ratio and minimum binder content based on the maximum density theory. The mix design method introduced in this study adopted the optimum fine aggregate ratio with a minimum void and binder content higher than the minimum binder content level. The research results reveal that the method helps to reduce trial and error in the mixing process and is a convenient way of producing high performance concrete with self filler ability. In an experiment based on the mix proportion method, when aggregate with the fine aggregation ratio of 41$\%$ was used, the minimum binder content of high performance concrete was 470kg/$m^{3}$ and maximum aggregate capacity was $0.657m^{3}/m^{3}$. In addition, in mixing high performance concrete, the optimal slump flow to meet filler ability was 65$\pm$5cm, V load flow speed ranged from 0.5 to 1.5.

  • PDF