• 제목/요약/키워드: optimum maintenance

검색결과 377건 처리시간 0.035초

Building structural health monitoring using dense and sparse topology wireless sensor network

  • Haque, Mohammad E.;Zain, Mohammad F.M.;Hannan, Mohammad A.;Rahman, Mohammad H.
    • Smart Structures and Systems
    • /
    • 제16권4호
    • /
    • pp.607-621
    • /
    • 2015
  • Wireless sensor technology has been opened up numerous opportunities to advanced health and maintenance monitoring of civil infrastructure. Compare to the traditional tactics, it offers a better way of providing relevant information regarding the condition of building structure health at a lower price. Numerous domestic buildings, especially longer-span buildings have a low frequency response and challenging to measure using deployed numbers of sensors. The way the sensor nodes are connected plays an important role in providing the signals with required strengths. Out of many topologies, the dense and sparse topologies wireless sensor network were extensively used in sensor network applications for collecting health information. However, it is still unclear which topology is better for obtaining health information in terms of greatest components, node's size and degree. Theoretical and computational issues arising in the selection of the optimum topology sensor network for estimating coverage area with sensor placement in building structural monitoring are addressed. This work is an attempt to fill this gap in high-rise building structural health monitoring application. The result shows that, the sparse topology sensor network provides better performance compared with the dense topology network and would be a good choice for monitoring high-rise building structural health damage.

Polyester 감량 폐수 중에 존재하는 Ethylene Glycol의 처리(II) -반응속도론- (Treatment of Ethylene Glycol in Polyester Weight Loss Wastewater(II) - Reaction Kinetics-)

  • Han, Myung-Ho;Kim, Jeong-Mog;Huh, Man-Woo
    • 한국염색가공학회지
    • /
    • 제8권6호
    • /
    • pp.27-32
    • /
    • 1996
  • This research is to investigate the reaction kinetics by air-lift bioreactor using calcium hydroxide, the neutralization agent and immobilization media, for removing ethylene glycol remained after chemical pretreatment. It was found that the optimum hydraulic retention time was obtained as 24.2hours at the optimum F/M ratio of 1.32kg-$TCOD_{Mn}$/day.kg-MLVSS, and then, infiuent $TCOD_{Mn}$ and MLVSS concentration were 3,290mg/l and 2,472mg/l, respectively. During the steady state, the kinetics constants such as maximum specific substrate removal rate, half saturation velocity coefficient, yield coefficient and endogenous respiration coefficient were estimated in the base of $TCOD_{Mn}$ as substrate concentration. And they were 1.47day$^{-1}$, 3.95mg/l, 0.391 and 0.092day$^{-1}$, respectively. And also, the oxgen use coefficients for cell synthesis, a', and energy of maintenance, b', were obtained as 0.4kg-O$_{2}$/kg-$TCOD_{Mn}$ and 0.056day$^{-1}$, at the steady state by the experimental result of oxygen uptake rate.

  • PDF

수리시설물 최적관리 시스템 개발 (Development of Optimum Management System for Irrigation Facilities)

  • 김선주;윤춘경;박성열;이광야
    • 한국농공학회지
    • /
    • 제39권2호
    • /
    • pp.86-94
    • /
    • 1997
  • For the efficient operation and maintenance( 0 & M), irrigation facilities were graded on the basis of their indices related to the 0 & M condition and the characteristics of reservoirs managed by Farmland Improvement Association(FIA) were examined. The results obtained are summarized as follows : 1. Characteristics of reservoirs include effective storage capacity, irrigation area, basin area, height and length of bank. Each characteristic is scored by the principle component analysis method. Variables which compose one index are categorized on the basis of their unit and each variable is scored so that the score of each unit sums to 100 for each index. 2. The Optimum MAnagement System of Irrigation Facilities(OMASIF) for Pyoungtaek area was developed by connecting general data of the irrigation facilities to image data. The database system is divided into three tables; LookUp Table, Facility Table, and Image Table. Image Table is again divided into five sub-tables, Image Table, Construction Cost Table, Acreage Table, 0 & M Cost Table, and Specification Table. 3. The evaluating criteria for the 0 & M of irrigation facilities can be established using the OMASIF. Irrigation facilities evaluated as poor state by the criteria should be repaired.

  • PDF

고온용 폴리머 윤활 베어링의 특성 연구 (Preparation and Characterization of Polymer Lubricating Bearings)

  • 한종대;김상근;김병관
    • Tribology and Lubricants
    • /
    • 제24권4호
    • /
    • pp.179-185
    • /
    • 2008
  • Microporous polymer lubricants(MPLs) are solid polymer materials containing micropores which are filled with liquid lubricants, and which are molded or formed to suit rolling bearings or other machine parts requiring lubrication. MPLs can be effectively applied to provide long-term, maintenance-free lubrication of a variety of machine elements without fully replacing of oils and greases. The application of rolling bearings packed fully with an MPL could reduce or eliminate the problems such as grease deterioration, leakage, under-lubrication caused by insertion of water or foreign matters under severe operation conditions. This paper discuss the application of MPLs for lubrication of rolling ball bearings. Two different MPLs were synthesized and the features of MPLs were tested. Characteristics of the bearings which are packed fully with synthesized MPLs were investigated using SEM, TG/DSC, extents of oil leakage, OIT, and life time test. After these preliminary tests twelve MPLs were synthesized and evaluated by measuring extents of oil leakage and OIT values. Then synthesis conditions for the optimum MPL were selected by SSRED(Six Sigma Robust Engineering Design) pro gram using extents of oil leakage and OIT values respectively. The optimum MPL by means of OIT value showed higher performance such as long life time and application at higher temperature of $140^{\circ}C$ than previous temperature of $100^{\circ}C$.

Activity Determination, Kinetic Analyses and Isoenzyme Identification of Gamma Glutamyltransferase in Human Neutrophils

  • Sener, Azize;Yardimci, Turay
    • BMB Reports
    • /
    • 제38권3호
    • /
    • pp.343-349
    • /
    • 2005
  • Gamma-glutamyltransferase (GGT, EC 2.3.2.2) which hydrolyzes glutathione (GSH), is required for the maintenance of normal intracellular GSH concentration. GGT is a membrane enzyme present in leukocytes and platelets. Its activity has also been observed in human neutrophils. In this study, GGT was purified from Triton X-100 solubilized neutrophils and its kinetic parameters were determined. For kinetic analyses of transpeptidation reaction, $\gamma$-glutamyl p-nitroanilide was used as the substrate and glycylglycine as the acceptor. Apparent $K_m$ values were determined as 1.8 mM for $\gamma$-glutamyl p-nitroanilide and 16.9 mM for glycylglycine. The optimum pH of GGT activity was 8.2 and the optimum temperature was $37^{\circ}C$. It had thermal stability with 58% relative activity at $56^{\circ}C$ for 30 min incubation. L-serine, in the presence of borate, was detected as the competetive inhibitor. Bromcresol green inhibited neutrophil GGT activity as a noncompetetive inhibitor. The neutrophils seem to contain only the isoenzyme that is present in platelets. We characterized the kinetic properties and compared the type of the isoenzyme of neutrophil GGT with platelet GGT via polyacrylamide gel electrophoresis (PAGE) under a standart set of conditions.

Determination of the Amino Acid Requirements and Optimum Dietary Amino Acid Pattern for Growing Chinese Taihe Silky Fowls in Early Stage

  • Li, Guanhong;Qu, Mingren;Zhu, Nianhua;Yan, Xianghua
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제16권12호
    • /
    • pp.1782-1788
    • /
    • 2003
  • A mathematical model has been constructed to estimate the amino acid requirements for growing Taihe silky fowls in early stage. A requirement was taken as the sum of the needs for maintenance, for gain in carcass weight without feathers, and for the feathers. The maintenance requirement was considered to be the sum of the needs for replacing skin and intestinal losses and for the obligatory creatinine excretion in the urine. A comparative slaughter trial and nitrogen balance trials with growing and adult Taihe silky fowls, respectively, were conducted to estimate the parameters in the model. The amino acid requirements were then calculated with the constructed models. The results showed as following: the replacement needs for skin nitrogen loss was determined at 213.41 mg/d for adult male fowls (body weight 1.60 kg); creatinine excretion in these birds was 4.04 mg/d. when fed an nitrogen-free diets, the adult male fowls with body weight 1.60 kg excreted a total of 246.10 mg/d endogenous nitrogen. The net protein requirement for maintenance was estimated at $11.24mg/w_g{^{0.75}}/d$Per gram of body weight gain contained 27.18 mg carcass nitrogen for growing birds in early stage, but feathers nitrogen in per gram of body weight gain increased with age. The amino acid requirements for growing Taihe silky fowls were slightly higher than for starting and growing pullets, but lower than that of broiler chicks. The amino acid requirements patterns changed with weeks of age.

A Comparative Study on the Efficiency of Locally Made Low Cost Brooders for Brooding Chicks

  • Hassanuzzaman, M.;Ahammad, M.U.;Bulbul, S.M.;Nurul Alam, A.M.M.;Islam, M.A.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • 제17권11호
    • /
    • pp.1586-1590
    • /
    • 2004
  • An experiment was carried out with day-old "Sonali" (♂RIR$\times$♀Fayoumi) chicks to investigate the efficacy of locally made low cost brooders for brooding chicks in rural areas. Three types of indigenous brooders viz. charcoal, haricane and sawdust brooders were used for brooding chicks throughout the experimental period of 28 days. The efficiency of the brooders was observed in respect of their ability to maintain temperature, fluctuation in temperature during operation and cost effectiveness. Following initial trial of temperature maintenance for 48 h, the chicks were put under the brooder stoves and brooded up to 28 days. The experimental birds were fed on chick starter diet. Maintenance of temperature with sawdust brooders was found satisfactory and optimum for brooding the chicks at different stages of brooding and at the same time involved least cost for brooding in comparison with charcoal and haricane brooders which did not perform well in generating heat necessary for brooding and were not economically feasible for poor farmers. On the other hand, performance of charcoal brooders was better in respect of temperature maintenance during initial stage (when the brooder was started) but the temperature fluctuated rapidly, whereas fluctuation of temperature was gradual in sawdust brooders. Body weight gain and feed conversion were best in sawdust brooders. Survivability was highest in sawdust brooders and lowest in haricane brooders. Sawdust brooders may be appropriate for brooding chicks in rural areas, where electricity is not available.

확률론적 생애주기비용-이익분석 기반 수명관리 최적화 기법 (Optimum Service Life Management Based on Probabilistic Life-Cycle Cost-Benefit Analysis)

  • 김선용
    • 한국산학기술학회논문지
    • /
    • 제17권4호
    • /
    • pp.19-25
    • /
    • 2016
  • 사회기반시설물을 포함한 구조물은 수명유지 또는 연장을 위하여 적절한 점검과 유지보수가 필수적이다. 이러한 점검과 유지보수는 일반적으로 생애주기비용 평가를 통해 관련 계획이 수립된다. 본 논문에서는 구조물의 생애주기비용과 그 사용으로 인해 발생되는 이익을 고려하는 확률론적 비용-이익분석과 이를 통한 구조물 최적수명 결정 방법을 다루고자 한다. 생애주기비용은 구조물 초기 제작/건설비용, 유지보수 비용과 구조물 파괴로 인한 예상손실을 고려하게 된다. 일반적으로 구조물의 수명연장은 생애주기비용의 증가를 유발하나 사용기간 증가로 인해 발생되는 이익 또한 증가하여, 이를 최적화하는 수명관리에 관심을 가질 필요가 있다. 생애주기 평가에 있어서 유지보수 적용이 구조성능, 구조물 파괴확률 그리고 수명에 미치는 영향을 확률론적 방법을 적용하여 평가하며, 이를 통해 생애주기비용과 이익의 차이를 목적함수로 구성하게 된다. 이 목적함수가 최대가 되는 지점이 설계변수인 구조물 최적수명이 되는데, 최적화문제 구성에 있어서 제한조건의 변화에 따라 유지보수 계획수립도 가능하다. 본 논문에서 다루어지는 구조물 수명관리 최적화기법이 안전성과 효율성을 동시에 고려하는 사회기반시설물 수명관리에 기여할 것으로 기대한다.

전산유체역학을 이용한 반도체 제조공정의 PM 전용 후드 설계 연구 (Design of local exhaust ventilation for preventive maintenance in semiconductor fabrication industry using CFD)

  • 홍좌령;구재한;박창섭;최광민
    • 한국산업보건학회지
    • /
    • 제29권2호
    • /
    • pp.208-216
    • /
    • 2019
  • Objective: The aim of this study is to control residual chemicals or by-products generated in chambers during preventive maintenance (PM) in the semiconductor manufacturing industry. We designed local exhaust ventilation using computational fluid dynamics (CFD). Methods: The air flow characteristics and capture efficiency between rectangular and slot hoods were compared numerically. The software Fluent 18.1 was used to estimate uniform velocity distribution and capture efficiency for contaminants. A metal from group 15 in the periodic table was released at the bottom of the chamber to simulate emissions. Results: The slot hood had a higher capture efficiency than a rectangular hood under the same conditions because the slot hood provided uniform air flow and higher face velocity. Also, there was no rotating swirl in the plenum for slot, that is why slot had better efficiency than rectangular even though they had similar face velocity. With less than 10 slots, the capture efficiencies for contaminants were nearly 95%. The optimum conditions for a hood to achieve high efficiency was 8 to 10 slots and a face velocity over 1 m/s. Conclusions: Well-designed ventilation systems must consider both efficiency and convenience. For this study, a slot hood that had high capture efficiency and no work disturbance was designed. This will contribute to protection of the worker's health in a PM area and other areas as well. Also, this study confirms the possibility of the application CFD in the semiconductor fabrication industry.

농업용수의 가격구조에 관한 연구 (A Study On Irrigation Water Price Structure and Prescription)

  • 심기영
    • 한국농공학회지
    • /
    • 제15권4호
    • /
    • pp.3170-3180
    • /
    • 1973
  • This study of the subject will review past and present irrigation development in Korea. Particular attention will be given to water pricing structure and a case study on the purpose of rational operation and management of irrigation water and organizations, and the optimum irrigation water and organizations, and the optimum irrigation water fee inorder to reduce farmers burden and to rationalize the farmland associations management so as to achieve development of the rural environment. In 1971, the reservoir of the Farmland Improvement A sociation (FIA) produced only 775 millison $m^3$ of irrigation water or 77% of planned capacity of 1,015 million $m^3$. It was caused by inefficient maintenance of irrigation facilities; for instance, about 21% of reservoirs, pumping stations and weirs in Korea have been silted by soil erosion which hinder to water production according to an ADC survey. The first Irritation Association was established in 1906, whcih was renamed the Farmland Assoeiation by the Rural Development Enouragement Law in 1970. By the end of 1971, 411,000 ha of rice paddies were under the control of 267 associations nationwide. The average water price assessed by Associations nationwide rose from 790 won per 0.1 ha. in 1966 to 1,886 won in 1971. The annual growth rate was 20%. The highest water price in 1971 was 4,773 won her 0.1 ha. and the lowest was 437 won. This range was caused by differences in debt burden, geographic conditions and management efficiency among the Associations. In 1971, the number of Associations which exceeded the average water price of 1,886 won per 0.1 ha. was 144, or 55.1% of all Association. In determination of water price, there are two principles; one is determined by production cost such as installation cost of irrigation facilities, maintenance cost, management cost and depreciation ect. For instance, the Yong San River Development project was required 33.7 billion won for total construction and maintenance cost is 3.1 billion won for repayment, maintenance and management cost per year. The project produces 590 million $m^3$ of irrigation water annually. Accordingly, the water price per $m^3$ is 5.25 won. The other principle is determined by water value in the crop products and in compared with production of irrigated paddy and non-irrigated paddy. By using this method, water value in compared with paddy rice vs. upland rice(Average of 1967-1971) was 14.15 won per $m^3$ and irrigated paddy vs. non-irrigated paddy was 2.98 won per $m^3$. In contrast the irrigation fee in average association of 1967-1971 was 1.54 won per $m^3$. Accordingly, the current national average irrigation fee(water price) is resonable compared with its water value. In this study, it is found that the ceiling of water price in terms of water value is 2.98 won per $m^3$ or 2,530 won per 0.1 ha. However, in 1971 55% of the associations were above the average of nationwide irrigation fees. which shows the need for rationalization of the Association's management. In connection with rationalization of the Association's management, this study recommends the following matters. (1) Irrigation fee must be assessed according to the amount of water consumption taking intoaccount the farmer's ability. (2) Irrigation fee should be graded according to behefits and crop patterns. (3) Training personnel in the operation and procedures of water management to save O&M costs. (4) Insolvent farmland association should be integrated into larger, sound associations in the same GUN in order to reduce farmers' water cost. (5) The maintenance and repair of existing irrigation facilities is as important as expansion of facilities. (6) Establishment of a new Union of Farmland Association is required to promoted proper maintenance and to protect the huge investment in irrigation facilities by means of technical supervision and guidance.

  • PDF