• Title/Summary/Keyword: optimal structure

Search Result 3,296, Processing Time 0.034 seconds

Numerical Study on the Baffle Structure for Determining the Flow Characteristic in Small Scale SCR System (소형 SCR 시스템 내 유동 제어를 위한 Baffle의 구조 결정에 관한 수치해석적 연구)

  • Park, Mi-Jung;Chang, Hyuk-Sang;Ha, Ji-Soo
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.9
    • /
    • pp.862-869
    • /
    • 2010
  • Numerical analysis was done to evaluate the gas flow distribution in small scale SCR system which has $2.4{\times}2.4{\times}3.1\;m^3$ in volume and 25,300 Sm3/hr in flue gas flow capacity. Various types of baffles proposed for controlling the flow uniformity were evaluated by the CFD analysis to find the optimal geometry of the baffle in the SCR system. By installing baffles in the SCR system, the RMS (%) value was raised up to 6.2% compared with the baffle-uninstalled state. The effect of baffle thicknesses on the RMS (%) value was not shown within 0 and 8 mm in thickness, but the RMS (%) value was raised by 2.5% in 10 mm of baffles thickness, which causes the unstability in flow. By comparison between the shape of baffles, it is known that the lattice type baffle has better performance in controlling the flow uniformity than the circular truncated cone type baffle or mixer type baffle. RMS (%) values have more that 10% difference according to the shape of baffle type.

Chloride Binding Properties of Portland Cement Binder Incorporating CaAl2O4-CaAl4O7 (CaAl2O4-CaAl4O7 혼입 포틀랜드 시멘트 결합재의 염소이온 고정 특성)

  • Han, Jae-Doh;Lee, Yun-Su;Lee, Han-Seung
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.24 no.4
    • /
    • pp.1-9
    • /
    • 2020
  • This study conducted to understand effects of CA (CaAl2O4) and CA2 (CaAl4O7) ratio on chloride binding ability and compressive strength and pore structure of cement mortar incorporating mixture of CA and CA2. The Portland cement based specimens were mixed with the clinkers CA and CA2, and these calcium aluminate clinker mixture were replaced 0, 5, 10% by weight of cement. After all the test specimens were cured for 28 days under water curing, they were immersed in the distilled water and NaCl solution. As a result, 28 days compressive strength of all specimens was similar, and As the replacement ratio of calcium aluminate clinker in the specimen increased, Friedel's salt production tended to increase. However, it was dependent on the amount of Al2O3 in the level of 5% replacement and CA ratio in the level of 10% replacement. Through equilibrium isotherm result, it was also indicated that as replacement ratio of calcium aluminate clinker in cement matrix increased, chloride binding capacity was improved, and chloride penetration was suppressed. In this study, the specimen replaced with 10% of the calcium aluminate clinker mixture (CA 39%, CA2 60%) was remarkable to control chloride attack. We figured out necessity to understand optimal CA/CA2 ratio to effectively apply CA2 as a sustainable building material by improving the chloride binding ability in Portland cement based system.

A Study on the Assessment of Standard Wage System for Forestry Workers in Korea (임업기능인 임금조사를 통한 직종별 기준임금 산정에 관한 연구)

  • Han, Sang-Kyun;Han, Han-Sup;Woo, Hee-Sung;Choi, Byoung-Koo;Cho, Min-Jae;Cha, Du-Song
    • Journal of Korean Society of Forest Science
    • /
    • v.104 no.4
    • /
    • pp.632-639
    • /
    • 2015
  • Working in the forest would require a wide range of skills and experience for specific tasks which involve with a high level of risks to worker's safety. However, there has been a concern on the current standard wage system for forest workers because it does not effectively reflect the characteristics of typical working conditions in the forest. In addition, the current standard wages for forestry workers was estimated based on the construction industry's wage system. Therefore, the purpose of this study is to assess a current wage system through the mail survey method and to develop a new wage system for forest worker which effectively reflects skill sets and experience required for successful completion of the work in the forest. We mailed the survey questionnaire consisting of 19 questions to 659 forest workers and received 188 responses resulting in a 28.5% response rate. The results showed that the current average optimal wages of forest worker, special worker and feller were 97,680won/day, 127,559won/day and 152,403won/day, respectively though there were variations depending on the regions. In developing the new standard wage system, this study suggest the current work types(worker, special worker and feller) could be divided into 5 work types (forest-environment workers, forest operations in beginner, forest operations in intermediate, forest operations in advanced and forest equipment operator) reflecting specialty of forest operation thereby stabilizing the new wage system for forest workers.

Two-dimensional Simulation Study on Optimization of Gate Field Plate Structure for High Breakdown Voltage AlGaN/GaN-on-Si High Electron Mobility Transistors (고내압 전력 스위칭용 AlGaN/GaN-on-Si HEMT의 게이트 전계판 구조 최적화에 대한 이차원 시뮬레이션 연구)

  • Lee, Ho-Jung;Cho, Chun-Hyung;Cha, Ho-Young
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.48 no.12
    • /
    • pp.8-14
    • /
    • 2011
  • The optimal geometry of the gate field plate in AlGaN/GaN-on-Si HEMT has been proposed using two-dimensional device simulation to achieve a high breakdown voltage for a given gate-to-drain distance. It was found that the breakdown voltage was drastically enhanced due to the reduced electric field at the gate corner when a gate field plate was employed. The electric field distribution at the gate corner and the field plate edge was investigated as functions of field plate length and insulator thickness. According to the simulation results, the electric field at the gate corner can be successfully reduced even with the field plate length of 1 ${\mu}m$. On the other hand, when the field plate length is too long, the distance between field plate and drain electrode is reduced below a critical level, which eventually lowers the breakdown voltage. The highest breakdown voltage was achieved with the field plate length of 1 ${\mu}m$. According to the simulation results varying the $SiN_x$ film thickness for the fixed field plate length of 1 ${\mu}m$, the optimum thickness range of the $SiN_x$ film was 200 - 300 nm where the electric field strength at the field plate edge counterbalances that of the gate corner.

Adaptive Decision Feedback Equalizer using the hierarchical Feedback filter and Soft decision device (계층적 궤환 필터 구조와 연판정 장치를 갖는 적응형 결정 궤환 등화기)

  • Lim, Dong-Guk;Song, Jeong-Ig;Kim, Jae-Mong
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.1
    • /
    • pp.138-145
    • /
    • 2007
  • Wireless transmission system using the multipath channel is affected ISI due to the delay spread. So we use a decision feedback equalizer which consist of decision part and feedback filter for remove the ISI effectively. In this paper, we propose a improved adaptive decision feedback equalizer to mitigate ISI effectively. The proposed adaptive decision feedback equalizer is construct by using soft decision device and hierarchical feedback filter based on MMSE sub-optimal equalizer using the LMS algorithm. Soft decision device mitigate the error propagation in feedback filter by incorrectly detected decision symbol and feedback filter which is divided two step independently mitigate the ISI by using a adaptive algorithm. As a result this structure shows better performance than conventional decision feedback equalizer by mitigating the error propagation in filter cause incorrectly detecting symbol. and we get the MSE more rapidly by using larger step-size due to reduce the number of feedback filter tap. In computer simulation, we compare the bit error rate performance of proposed decision feedback equalizer with conventional one on the S-V channel model for UWB system.

Total Degradation Performance Evaluation of the Time- and Frequency-Domain Clipping in OFDM Systems (OFDM 시스템에서 시간 및 주파수 영역 클리핑의 Total Degradation 성능평가)

  • Han, Chang-Sik;Seo, Man-Jung;Im, Sung-Bin
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.44 no.7 s.361
    • /
    • pp.17-22
    • /
    • 2007
  • OFDM (Orthogonal Frequency Division Multiplexing) is a special case of multicarrier transmission, where a single data stream is transmitted over a number of lower-rate subcarrier. One of the main reasons to use OFDM is to increase robustness against frequency-selective fading or narrowband interference. Unfortunately, an OFDM signal consists of a number of independently modulated subcarriers, which can give a large PAPR (Peak-to-Average Power Ratio) when added up coherently. In this paper, we investigate the performance of a simple PAPR reduction scheme, which requires no change of a receiver structure or no additional information transmission. The approach we employed is clipping in the time and frequency domains. The time-domain clipping is carried out with a predetermined clipping level while the frequency-domain clipping is done within EVM (Error Vector Magnitude). This approach is suboptimal with lower computational complexity compared to the optimal method. This evaluation is carried out on the OFDM system with an nonlinear amplifier. The simulation results demonstrated that the PAPR reduction algorithm is one of ways to reduce the effects of the nonlinear distortion of an HPA (High Power Amplifier).

Applying a Two-channel Video Streaming Technology Front and Rear Vehicle Wireless Video Monitoring System (2채널 영상 스트리밍 기술을 적용한 차량용 전. 후방 무선 영상 모니터링 시스템)

  • Na, HeeSu;Won, YoungJin;Yoon, JungGeun;Lee, SangMin;Ahn, MyeongIl;Kim, DongHyun;Moon, JongHoon
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.51 no.12
    • /
    • pp.210-216
    • /
    • 2014
  • In this paper, it was proposed to develop front and rear image monitoring system for vehicle that help a driver to cope with urgent situation about a dangerous element. When parking a vehicle, the risk factors to be formed by the dead zone can be resolved by using anterior and posterior cameras of the vehicle. In embedded system environment, a SoC(System on Chip) and two high-resolution CMOS (Complementary metal-oxide-semiconductor) image sensors were used to transfer two high-resolution image data through he TCP/ IP-based network. To transfer image data through he TCP/ IP-based network, the images received by two cameras were compressed by using H.264 and they were transmitted with wireless method(Wi-Fi) by using real-time transport protocol (Real-time Transport Protocol). Transmission loss, transmission delay and transmission limit were solved in wireless (Wi-Fi) environment and the bit-rate of two image data compressed by H.264 was adjusted. And the system for the optimal transmission in wireless (Wi-Fi) environment was materialized and experimented.

A Study of Dual-Frequency Microstrip Patch Antenna (이중공진 마이크로스트립 패치 안테나에 관한 연구)

  • 장준영;김준모;윤영중;엄순영;전순익
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.9 no.4
    • /
    • pp.515-525
    • /
    • 1998
  • In this paper, for both transmission and reception with single antenna system of satellite communication, dual-frequency antennas which operate simultaneously at 12.5 GHz and at 14.25 GHz are designed, constructed and measured. Also by using dual feeding structure, the problems of single-fed dual-frequency antenna such as the separation of transmitting and receiving signals and single polarization, are solved. Microstrip patch as a radiation element of dual-fed dual-frequency antenna has width and length which are the resonance lengths of the corresponding frequencies for transmission and reception, respectively. The effects of the feed line on the other frequency feeding are minimized with the optimal matching scheme for the feed lines. For solving the space problems of dual-fed two-dimensional array antennas, microstrip-line and coaxial probe feedings are used for each frequency and a two-dimensional $2\times2$ array antenna was designed and measured their characteristics. The experimental results show that errors of resonance frequencies are less than 1.44%, the return losses are less than -21 dB and the isolations between two feeding ports are less than -21 dB. The characteristics of radiation patterns of dual frequency microstrip antenna are measured and evaluated. The directivities, sidelobe levels and cross polarizations are also measured and compared with the simulations. The results show some errors due to the misalignment of coaxial probe feeding.

  • PDF

Smart Farm Expert System for Paprika using Decision Tree Technique (의사결정트리 기법을 이용한 파프리카용 스마트팜 전문가 시스템)

  • Jeong, Hye-sun;Lee, In-yong;Lim, Joong-seon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.373-376
    • /
    • 2018
  • Traditional paprika smart farm systems are often harmful to paprika growth because they are set to follow the values of several sensors to the reference value, so the system is often unable to make optimal judgement. Using decision tree techniques, the expert system for the paprika smart farm is designed to create a control system with a decision-making structure similar to that of farmers using data generated by factors that depend on their surroundings. With the current smart farm control system, it is essential for farmers to intervene in the surrounding environment because it is designed to follow sensor values to the reference values set by the farmer. To solve this problem even slightly, it is going to obtain environmental data and design controllers that apply decision tree method. The expert system is established for complex control by selecting the most influential environmental factors before controlling the paprika smart farm equipment, including criteria for selecting decisions by farmers. The study predicts that each environmental element will be a standard when creating smart farms for professionals because of the interrelationships of data, and more surrounding environmental factors affecting growth.

  • PDF

Three-Phase Eulerian Computational Fluid Dynamics (CFD) of Air-Water-Oil Separator with Coalescer (유적 합체기가 포함된 공기-물-기름 분리 공정에 대한 3상 Eulerian 전산유체역학)

  • Lim, Young-Il;Le, Thuy T.;Park, Chi-Kyun;Lee, Byung-Don;Kim, Byung-Gook;Lim, Dong-Ha
    • Korean Chemical Engineering Research
    • /
    • v.55 no.2
    • /
    • pp.201-213
    • /
    • 2017
  • Water is removed from crude oil containing water by using oil separator. This study aims to develop a three-dimensional (3D) Eulerian computational fluid dynamics (CFD) model to predict the separation efficiency of air-water-oil separator. In the incompressible, isothermal and unsteady-state CFD model, air is defined as continuous phase, and water and oil are given as dispersed phase. The momentum equation includes the drag force, lift force and resistance force of porous media. The standard k-${\varepsilon}$ model is used for turbulence flow. The exit pressures of water and oil play an important role in determining the liquid level of the oil separator. The exit pressures were identified to be 6.3 kPa and 5.1 kPa for water and oil, respectively, to keep a liquid level of 25 cm at a normal operating condition. The time evolution of volume fractions of air, water and oil was investigated. The settling velocities of water and oil along the longitudinal separator distance were analyzed, when the oil separator reached a steady-state. The oil separation efficiency obtained from the CFD model was 99.85%, which agreed well with experimental data. The relatively simple CFD model can be used for the modification of oil separator structure and finding optimal operating conditions.