• 제목/요약/키워드: optimal sensitivity

검색결과 1,234건 처리시간 0.032초

불완전한 생산 시스템에서의 경제적인 생산량 결정 (An EMQ Model in An Unreliable Machine)

  • 김창현;홍유신;김수영
    • 대한산업공학회지
    • /
    • 제20권2호
    • /
    • pp.3-17
    • /
    • 1994
  • This paper presents an EMQ model which determines an optimal manufacturing lot size in an unreliable machine. The machine has an exponentially distributed life time, and requires a constant time to repair when it fails. We 1) derive an average cost function, 2) obtain an optimal lot size and show that it is unique, 3) carry out sensitivity analysis to examine the effect of machine parameters (life time, time to repair) to optimal lot size.

  • PDF

유한요소법에 의한 이중 금속봉 압출 공정의 금형 형상 최적설계 (Die Shape Optimal Design in Bimetal Extrusion by The Finite Element Method)

  • 변상민;황상무
    • 소성∙가공
    • /
    • 제3권3호
    • /
    • pp.302-319
    • /
    • 1994
  • A new approach to die shape optimal design in bimetal extrusion of rods is presented. In this approach, the design problem is formulated as a constrained optimization problem incorporated with the finite element model, and optimization of the die shape is conducted on the basis of the design sensitivities. The combinations of the core and sleeve materials.

  • PDF

유전 알고리즘을 이용한 한계비용내의 최적 공차 설계 (Optimal Tolerance Design within Limited Costs using Genetic Algorithm)

  • 장현수;이병기;김선호
    • 산업경영시스템학회지
    • /
    • 제22권49호
    • /
    • pp.33-41
    • /
    • 1999
  • The original tolerances, which are assigned by designers on the basis of handbooks and experience, cannot always be expected to be optimal or feasible, because they may yield an unacceptable manufacturing costs. So the systematic tolerance design considering manufacturing costs should be done. Therefore, this research analyzes the tolerance within the tolerance design using Monte-Carlo simulation method and sensitivity analysis and using genetic algorithm by tolerance allocation method. The genetic algorithm was developed for allocation of the optimal tolerance under the manufacturing limitation cost.

  • PDF

인접구조물의 진동제어를 위한 선형감쇠시스템의 최적설계 (Optimal Design of Linear Viscous Damping System for Vibration Control of Adjacent Building Structures)

  • 박관순;옥승용;고현무
    • 한국지진공학회논문집
    • /
    • 제10권3호
    • /
    • pp.85-100
    • /
    • 2006
  • 이 논문에서는 서로 다른층 높이를 갖는 인접한 두 빌딩의 내진성능을 효율적으로 향상시킬 수 있는 선형 점성 감쇠기의 최적 설계방법을 제시하고자 한다. 이를 위하여 층간 대각 브레이싱 형태의 에너지 소산장치 연결방법과 인접 구조물간 에너지 소산장치 연결방법을 고려하였으며, 두 가지 연결방법을 적용한 시스템에 대한 감쇠용량별 주파수응답함수 비교를 통하여 구조물간 연결방법의 효율성을 확인하였다. 아울러 구조물간 연결방법에서 주파수응답함수를 최소화하는 최적 감쇠용량이 존재하는 것을 보이고, 최적 설계된 시스템에 대하여 감쇠용량별 구조물의 고유주파수 및 등가감쇠비의 민감도를 분석하였다. 민감도 분석 결과로부터 고층부에 설치되는 에너지 소산장치가 구조물의 등가 감쇠비를 효율적으로 증가시키는 것을 확인하였다. 따라서 민감도에 비례하는 새로운 감쇠기 설계방법을 제시하고, 대각 브레이싱 연결방법과 구조물간 연결로서 균등분포 및 제시하는 민감도 기반 분포에 따른 연결방법을 적용한 시스템들의 내진성능을 비교 분석하였다. 지진응답의 비교결과, 제시하는 방법이 인접 구조물의 효과적인 내진설계방법이 될 수 있음을 입증하였다.

밀도법 기반 위상 최적설계의 실험적 검증 (Experimental Validation of Topology Design Optimization)

  • 차송현;이승욱;조선호
    • 한국전산구조공학회논문집
    • /
    • 제26권4호
    • /
    • pp.241-246
    • /
    • 2013
  • 본 논문에서는 밀도법 기반 위상 최적설계를 통해 얻어진 수치 결과를 바탕으로 CAD 모델을 구성하고 이를 3차원 프린터로 제작하여 실험적으로 최적설계를 검증하였다. 위상 최적설계 과정에서는 체커보드(Checkerboard) 현상이나 잔가지가 종종 나타나는데, 이는 최적설계 구조물을 실제로 제작함에 있어서 어려움을 준다. 이러한 문제점을 해결하기 위하여 민감도 필터링과 모폴로지 기법을 사용하였다. 엄밀한 검증을 위하여 수치 모델과 실험 모델의 부피율을 일치시켰다. 위상 최적설계를 포함한 다양한 설계에 대하여 실험을 통해 비교하여 최적설계 구조물이 가장 높은 강성을 가지고 있음을 확인하였으며 컴플라이언스에 대한 실험결과는 수치해석 값과 잘 일치함을 확인하였다.

회수제품 재가공이 이루어지는 시스템에서 최적 신제품 구매정책과 최적 주문량에 대한 연구 (Joint Decision of Optimal Procurement Policy and Optimal Order ize for a Product Recovery System)

  • 김은갑;정봉주
    • 대한산업공학회지
    • /
    • 제34권4호
    • /
    • pp.398-407
    • /
    • 2008
  • We consider a product recovery system that a single product is stocked in order to meet a demand from customers who may return products after usage. This paper addresses a problem of when to release a procurement process to replenish serviceable inventory and how many new products to procure. The structure of the optimal procurement policy is examined and numerically identified as a monotonic threshold curve. A numerical procedure is presented to jointly find the optimal procurement order size, optimal procurement policy, and optimal discounted profit. Sensitivity analysis also indicates that these optimal performance measurements have monotonic properties with respect to system parameters.

An Experimental Investigation on the Contamination Sensitivity of an Automotive Fuel Pump

  • Lee Jae-Cheon;Shin Hyun-Myng
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제6권3호
    • /
    • pp.51-55
    • /
    • 2005
  • This study addresses the contamination sensitivity test of a typical fuel pump for an automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of a fuel pump on specific contaminant particle sizes so that an optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of the fuel pump is measured under the experiments of various contaminants size ranges of ISO test dust up to $80\;{\mu}m$. The fundamental theory of contamination sensitivity is introduced and the contamination sensitivity coefficients are estimated using the experimental data. Maximum contamination sensitivity coefficient of $5\chi\;10^{-6}\;L/min{\cdot}Ea$ is found in the contaminant size range of $40\;{\mu}m\~50\;{\mu}m$. The magnified picture of the surface of vane disc reveals that the abrasive wear is the principal cause of discharge flow rate degradation. Hence, this study reveals that a high efficiency filter for contaminant particles especially in the size range of $30\;{\mu}m\~70\;{\mu}m$ especially should be used to maintain the service life of the fuel filter.

자동차 연료펌프의 오염민감도 실험 연구 (An Experimental Investigation on The Contamination Sensitivity of An Automotive Fuel Pump)

  • 이재천;장지현;신현명
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.102-108
    • /
    • 2004
  • This study addresses the contamination sensitivity test of a typical fuel pump for automotive vehicle. The objective of the study is to find the contamination sensitivity coefficient of fuel pump on specific contaminant particle sizes so that optimal fuel filter could be selected. To achieve the objective, the degradation of discharge flow rate of fuel pump was measured under the experiments of various contaminants size ranges of ISO test dust up to 80${\mu}{\textrm}{m}$. The fundamental theory of contamination sensitivity was introduced and the contamination sensitivity coefficients were estimated using the experimental data. Maximum contamination sensitivity coefficient of $5{\times}10^{-6}$ L/minㆍEa was found on the contaminant size range of 40${\mu}{\textrm}{m}$∼50${\mu}{\textrm}{m}$. The magnified picture of the surface of vane disc revealed that the abrasive wear was the principal cause of discharge flow rate degradation. Hence, this study revealed that high efficiency filter on the contaminant particle size range of 30${\mu}{\textrm}{m}$∼70${\mu}{\textrm}{m}$ especially should be used to maintain the service lift of the fuel filter.

양식넙치(Paralichthys olivaceus)의 복수증에 관한 연구 - Edwardsiella tarde의 일부 특성과 병원성 및 대책 - (Studies on the Edwardsiellosis of cultured flounder, Paralichthys oliuaceus;- Characteristics, pathgenicity and control of Edwardsiella tarda -)

  • 한재철;김영진;서형석;김영길;이근광;안병목
    • 한국동물위생학회지
    • /
    • 제20권1호
    • /
    • pp.11-18
    • /
    • 1997
  • Characteristics, pathogenicity and control of the causative organisms isolated front diseased cultured flounder, Paralichthys olivaceus were studied. The causative organisms were identified as E tarda by biochemical and biophysical characteristics. Also, it strains were named as E tarda KBF-1 and E tarda KMF-1, and optimal pH of E tarda KBF-1 and E tarda KMF-1 were 8.0, and optimal concentration of NaCl. E tarda KBF-1 was 0% and E tarda KMF-1 was 1%. In the pathogenicity test, 0~10 of the flounders of artificially infected group(E tarda KBF-1) with $1.0{\times}10^7$ cfu/fish were died within 60 hrs, but 0~9 flounders infected group with 41.0{\times}10^6$ cfu/fish were died within 60 hrs. Also, 0~10 flounders infected group(E tarda KMF-1) with $1.0{\times}10^7$ cfu/fish were died within 36 hrs, while 0~7 flounders infected with $1.0{\times}10^6$ cfu/fish were died within 60 hrs. Drug sensitivity of E tarda KBF-1 strain was resistant to AM, CF and N, and intermediate to E, K and S, and sensitivity to C, G, SxT and FF. But E tarda KMF-1 strain was resistant to CF, E and V, and intermediate to AM, C, N and SxT, and sensitivity to GM and FF.

  • PDF

Comparison of the Pediatric Balance Scale and Fullerton Advanced Balance Scale for Predicting Falls in Children With Cerebral Palsy

  • Kim, Gyoung-mo
    • 한국전문물리치료학회지
    • /
    • 제23권4호
    • /
    • pp.63-70
    • /
    • 2016
  • Background: The Pediatric Balance Scale (PBS) and the Fullerton Advanced Balance (FAB) scale were used to assess balance function in patients with balance problem. These multidimensional clinical balance scales provide information about potential risk factors for falls. Objects: The purpose of this study was to investigate and compare the predictive properties of the PBS and FAB scales relative to fall risk in children with cerebral palsy (CP) using a receiver operating characteristic analysis. Methods: In total, 49 children with CP (boy=21, girl=28) who were diagnosed with level 1 or 2 according to the Gross Motor Function Classification System participated in this study. The PBS and FAB were performed, and verified cut-off score, sensitivity, specificity, and the area of under the curve (AUC). Results: In this study, the PBS scale was as a predictive measure of fall risk, but the FAB was not significant in children with CP. A cut-off score of 45.5 points provided optimal sensitivity of .90 and specificity of .69 on the PBS, and a cut-off score of 21.5 points provided optimal sensitivity of .90 and specificity of .62 on the FAB. Both scales showed moderately accurate of AUC with .79 and .76, respectively. Conclusion: The PBS is a useful screening tool for predicting fall risk in children with cerebral palsy, and those who score 45.5 or lower indicate a high risk for falls and are in need of balance intervention.