• Title/Summary/Keyword: optimal release time

Search Result 113, Processing Time 0.027 seconds

A study on grid aspect ratio of fire dynamics simulator (FDS의 격자 종횡비에 관한 연구)

  • Kim, Won Ouk;Park, Woe-Chul
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.39 no.9
    • /
    • pp.923-928
    • /
    • 2015
  • The FDS is one of the most used programs for fire analysis and needs an optimal grid selection for an accurate analysis. This study selected various grid aspect ratios (ARs) for selection of optimal grid and analyzed them with FDS v 6.1.2. A calculation time of 10 min. was used, which is enough to obtain the time average value of temperature changes. Temperature, visibility, and the time average value of mass balance are obtained from 200-600 s, which is a period of maintaining quasi-steady state. Two polyurethane fires of 1 [MW] and 2 [MW] in two enclosures of $10{\times}10{\times}3[m^3]$ and $20{\times}20{\times}3[m^3]$ were considered. Time variations of heat release rates, temperature, visibility, and mass balance were compared for ARs from 1-6. The heat release rates were accurate for all aspect ratios regardless of fire and enclosure sizes. The quasi-steady state temperature and visibility were well predicted for $AR{\leq}5$. Temperature drop and skewness of mass conservation, however, increased with increasing aspect ratio. Therefore, careful investigation of the grid size is recommended in performance-based design when $AR{\geq}3$, where temperature and visibility in early stage of a fire are important parameters. For accurate simulations of enclosure fires, grid sizes of 0.1~0.2 [m] and smaller in the vertical direction and $AR{\leq}2$ are recommended.

Single-stranded DNA Enhances the Rate of Product Release During Nucleotide Hydrolysis Reaction by T7 DNA Helicase

  • Kim, Dong-Eun;Jeong, Yong-Joo
    • Bulletin of the Korean Chemical Society
    • /
    • v.27 no.10
    • /
    • pp.1618-1622
    • /
    • 2006
  • Bacteriophage T7 gp4A' is a ring-shaped hexameric DNA helicase that catalyzes duplex DNA unwinding using dTTP hydrolysis as an energy source. To investigate the effect of single-stranded DNA (ssDNA) on the kinetic pathway of dTTP hydrolysis by the T7 DNA helicase complexed with ssDNA, we have first determined optimal concentration of long circular M13 single-stranded DNA and pre-incubation time in the absence of $Mg^{2+}$ which is necessary for the helicase-ssDNA complex formation. Steady state dTTP hydrolysis in the absence of $Mg^{2+}$ by the helicase-ssDNA complex provided $k_{cat}$ of $8.5\;{\times}\;10^{-3}\;sec^{-1}$. Pre-steady state kinetics of the dTTP hydrolysis by the pre-assembled hexameric helicase was monitored by using the rapid chemical quench-flow technique both in the presence and absence of M13 ssDNA. Pre-steady state dTTP hydrolysis showed distinct burst kinetics in both cases, indicating that product release step is slower than dTTP hydrolysis step. Pre-steady state burst rates were similar both in the presence and absence of ssDNA, while steady state dTTP hydrolysis rate in the presence of ssDNA was much faster than in the absence of ssDNA. These results suggest that single-stranded DNA stimulates dTTP hydrolysis reaction by T7 helicase by enhancing the rate of product release step.

Estimation of Distance and Direction for Tracking of the Moving Object

  • Kang, Sung-Kwan;Park, Jong-An
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.557-557
    • /
    • 2000
  • Tracking of the moving object, which is realized by the computer vision, is used for military and industrial fields. It is the application technique with imply complicated processing for understanding the input images. But, in these days, the most moving object tracking algorithms have many difficult problems. A typical problem is the increase of calculation time depending on target number. For this reason, there are many studies to solve real time processing problems and errors for background environmental change. In this paper, we used optical flow which is one of moving object tracking algorithms. It represents vector of the moving object. Optical flow estimation based on the regularization method depends on iteration method but it is very sensitive the noise. We proposed a new method using the Combinatorial Hough Transform (CHT) and Voting Accumulation in order to find optimal constraint lines. Also, we used the logical operation in order to release the operation time. The proposed method can easily and accurately extract the optical flow of moving object area and the moving information. We have simulated the proposed method using the test images. This images are included the noise. Experimental results show that the proposed method get better flow and estimate accurately the moving information.

  • PDF

Enhanced Myocardial Protection by Addition of Creatine Phosphate to the St. Thomas Hospital Cardioplegic Solution -Studies in the rat - (St. Thomas Hospital 심정지액에 Creatine Phosphate 를 첨가한 후 심근 보호 효과)

  • 최순호
    • Journal of Chest Surgery
    • /
    • v.22 no.4
    • /
    • pp.580-588
    • /
    • 1989
  • The potential for enhancing myocardial protection by adding high-energy phosphate to cardioplegic solutions [St. Thomas Hospital solution] was investigated in a rat heart model of cardiopulmonary bypass and ischemic arrest. Creatine phosphate was evaluated as an additive to the St. Thomas Hospital cardioplegic solution. Creatine phosphate 10.0 mmol/L as the optimal concentration which improved recovery of aortic flow and cardiac output after a 30 minute period of normothermic [37oC] ischemic arrest. In comparing mechanical function in both groups the mean postischemic recoveries of aortic flow, cardiac output, stroke volume and stroke work [expressed as a percentage of its preischemic control] were significantly greater in STH-CP group than in CP- free control group. In addition to improving function and decreasing CK release, CP reduced reperfusion arrhythmias significantly decreasing the time between cross-clamp removal and return to regular rhythm from 81.8 * 13.9 [sec] in CP-free group to 35.9 * 6.8 [sec] in CP group [P< 0.05] so, exogenous CP exerts potent protective and antiarrhythmic effects when added to the St. Thomas Hospital cardioplegic solution. However, the mechanism of action remains to be elucidated.

  • PDF

A Study on the Prepreg Treatment to Improve Interlaminar Fracture Behavior of Graphite/Epoxy Composites (Graphite/Epoxy 적층복합재의 층간파괴 향상을 위한 프리프레그의 전처리 연구)

  • Kim, Min-Ho;Rhee, Kyong-Yop;Paik, Young-Nam;Kim, Hyeon-Ju;Jung, Dong-Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.10
    • /
    • pp.68-73
    • /
    • 2006
  • In this study, the graphite/epoxy prepregs were surface-treated using oxygen plasma, and optimal treatment time was determined measuring the contact angle on the prepreg surface. Interlaminar fracture behavior of surface-treated graphite/epoxy composites was compared with that of regular (untreated) graphite/epoxy composites. The results showed that the contact angle was a minimum when treated for 30 minutes. The interlaminar fracture toughness of surface-treated specimen was improved about 15% compared with that of regular specimen.

The Comparative Study of Software Optimal Release Time Based on Record Value Statistics (기록값 통계량을 이용한 소프트웨어 최적 방출시기에 관한 비교 연구)

  • Kim, Hee-Cheul;Park, Hyoung-Keun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.659-662
    • /
    • 2009
  • 본 연구에서는 소프트웨어 제품을 개발하여 테스팅을 거친 후 사용자에게 인도하는 시기를 결정하는 방출문제에 대하여 연구되었다. 소프트웨어의 결함을 제거하거나 수정 작업 중에도 새로운 결함이 발생될 가능성이 있는 무한고장수를 가진 비동질적인 포아송 과정에 기초하고 수명분포는 신뢰도 측면에서 여러 분포들을 적합시키는데 효율적인 특성을 가진 와이블분포를 이용한 최적 방출시기에 관한 문제를 제시하여 소프트웨어 요구 신뢰도를 만족시키고 소프트웨어 개발 및 유지 총비용을 최소화 시키는 최적 소프트웨어 방출 정책에 대하여 논의되었다.

  • PDF

Simulation and Prediction on the Performance of a Hydrogen Engine

  • Han, Sung Bin
    • Journal of Energy Engineering
    • /
    • v.24 no.4
    • /
    • pp.217-222
    • /
    • 2015
  • A computer simulation has been developed to predict and investigate the performance of the assumed hydrogen engine. The simulation has be come a powerful tool as it saves time and also economical when compared to experimental study. The effects of various parameters, such as equivalent ratio, spark advance, revolutions per minute were calculated and then the optimal parameters of assumed engine were determined. The effects of spark advance, revolutions per minute, cylinder pressure, rate of pressure rise, flame temperature, rate of heat release, and mass fraction burned were simulated. The objective of the research paper is to develop a internal combustion model with hydrogen as a fuel.

The Comparative Study of Software Optimal Release Time Based on Log property Distribution (로그형 특성분포에 근거한 소프트웨어 최적 방출시기에 관한 비교 연구)

  • Kim, Hee-Cheul;Park, Hyoung-Keun
    • Proceedings of the KAIS Fall Conference
    • /
    • 2010.05a
    • /
    • pp.149-152
    • /
    • 2010
  • 본 연구에서는 소프트웨어 제품을 개발하여 테스팅을 거친 후 사용자에게 인도하는 시기를 결정하는 방출문제에 대하여 연구되었다. 인도시기에 관한 모형은 무한 고장 수에 의존하는 비동질적인 포아송 과정을 적용하였다. 이러한 포아송 과정은 소프트웨어의 결함을 제거하거나 수정 작업 중에도 새로운 결함이 발생될 가능성을 반영하는 모형이다. 적용모형은 여러 수명 분포들을 적합시키는데 효율적인 특성을 가진 콤페르쯔, 파레토, 로그-로지스틱 모형과 같은 로그형 특성분포를 이용하였다. 따라서 소프트웨어 요구 신뢰도를 만족시키고 소프트웨어 개발 및 유지 총비용을 최소화 시키는 방출시간이 최적 소프트웨어 방출 정책이 된다. 본 논문의 수치적인 예에서는 고장 간격 시간 자료를 적용하고 모수추정 방법은 최우추정법을 이용하여 최적 방출시기를 추정하였다.

  • PDF

ELUTION OF RESIDUAL MONOMER ACCORDING TO VARIOUS LIGHT SOURCES AND CURING TIME ON THE POLYMERIZATION OF PHOTOACTIVATED PIT AND FISSURE SEALANTS (광중합 광원의 종류와 조사시간에 따른 치면열구전색제의 미반응 모노머 용출)

  • Oh, You-Hyang;Park, Yoon-Kyung;Lee, Nan-Young;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.3
    • /
    • pp.421-430
    • /
    • 2004
  • The purpose of this study was to measure and compare the amount of unreacted TEGDMA from pit and fissure sealants cured with three different light sources; conventional halogen light curing unit, plasma arc light curing unit and argon laser. The specimens were eluted in distilled water for different time intervals. The time-related release of TEGDMA were analyzed by reverse-phase high performance liquid chromatography(HPLC). The result of present study can be summarized as follows: 1. The time-related release of TEGDMA decreased with increasing curing time in conventional halogen light, however, that not statistically significant difference(p>0.05). 2. The elution from the specimens cured for 6 and 9 seconds with plasma arc light was similar results corresponding with the time-related TEGBMA release, and was significantly lower than that cured for 3 seconds(p<0.05). 3. The elution of TEGDMA from the specimens cured with argon laser was significantly higher than that cured with halogen and plasma arc light(p<0.05). 4. The elution of TEGDMA from under recommended time of three different light sources were showed to be no statistically significant difference(p>0.05). 5. In time-related release of TEGDMA from recommended time of each light sources, the results correspond to 40 seconds of halogen light and 6 seconds of plasma arc light were similar(p>0.05). 6. The elution of TEGDMA, from over recommended time of three different light sources were showed to be no statistically significant difference(p>0.05). In this study, I suggest that curing time of plasma arc light is 6 and/or 9 seconds in the field of clinical pediatric dentistry claiming its effectiveness in optimal polymerization and reduced chair time.

  • PDF

Application Effect of the Controlled Release Fertilizer Applied on Seedling Tray at Seeding Time in Rice (벼 모판 파종동시처리 완효성비료 시용효과)

  • Won, Tae-Jin;Choi, Byoung-Rourl;Cho, Kwang-Rae;Lim, Gab-June;Chi, Jeong-Hyun;Woo, Sun-Hee
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.64 no.3
    • /
    • pp.204-212
    • /
    • 2019
  • The optimal application rate of a controlled release fertilizer (CRF) on the growth, yield, and seeding time of rice grown on seedling trays was investigated. The experimental field was located at $37^{\circ}22^{\prime}10^{{\prime}{\prime}}N$ latitude and $127^{\circ}03^{\prime}85^{{\prime}{\prime}}E$ longitude in Hwaseong, Gyeonggi-do, Republic of Korea. The soil in the paddy field was a clay loam. The CRF used in the experiment contained $300g\;kg^{-1}$ of nitrogen, $60g\;kg^{-1}$ of phosphate, and $60g\;kg^{-1}$ of potassium, respectively. The CRF was applied at the rate of 0, 200, 300, 400, 500, and 600 grams on rice seedling tray compared with the field application based on soil testing (control), respectively. The CRF can be applied as single application(which can replace basal fertilizer application and two top dressing application) directly to the seedling tray, and showed the minimum release at the seedling period. Considering the plant growth, nitrogen use efficency and yield of rice, the optimal application rate of developed CRF was 500 g per seedling tray and the yield of rice at this application rate was $4.92{\sim}5.04Mg\;ha^{-1}$. The regression formula between the rice yield and application rates of CRF was as follows ; "$Y=0.0002{\chi}^2+0.0963{\chi}+411.6$($R^2$ : 0.9922) in 2010 and $Y=8E-6{\chi}^2+0.2723{\chi}+344.04$($R^2$:0.9864) in 2011, Y : Rice yield ($Mg\;ha^{-1}$), ${\chi}$ : Application rate (grams) of controlled release fertilizer". The optimum application rates of CRF per rice seedling tray by regression formula was 498 grams in 2010 and 513 grams in 2011.