• Title/Summary/Keyword: optimal heating regions

Search Result 8, Processing Time 0.024 seconds

Determination of Optimum Heating Regions for Thermal Prestressing Method Using Artificial Neural Network (인공신경망을 이용한 온도프리스트레싱 공법의 적정 가열구간 설정에 관한 연구)

  • 김상효;김준환;김강미
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2003.04a
    • /
    • pp.327-334
    • /
    • 2003
  • Thermal Prestressing Method for continuous composite girder bridges is a new design and construction method developed to induce initial composite stresses in the concrete slab at negative bending regions. Due to the induced initial stresses, prevention of tensile cracks at concrete slab, reduction of steel girder section, and reduction of reinforcing bars are possible. Thus, economical and construction efficiency can be improved. Method for determining optimum heating region of Thermal Prestressing Method, has not been established although such method is essential for increasing efficiency of the designing process. Trial-and-error method used in previous studies is far from efficient and more rational method for computing optimal heating region is required. In this study, efficient method for determining optimum heating region in the use of Thermal Prestressing Method is developed based on artificial neural network algorithm, which is widely adopted to pattern recognition, optimization, diagnosis, and estimation problems in various fields. Back-propagation algorithm, which is commonly used as a learning algorithm in neural network problems, is used for training of the neural network. Through case studies of 2-span continuous and 3-span continuous composite girder bridges using the developed process, the optimal heating regions are obtained.

  • PDF

Determination of Optimum Heating Regions for Thermal Prestressing Method Using Artificial Neural Network (인공신경망을 이용한 온도프리스트레싱 공법의 적정 가열구간 설정에 관한 연구)

  • Kim, Jun Hwan;Ahn, Jin-Hee;Kim, Kang Mi;Kim, Sang Hyo
    • Journal of Korean Society of Steel Construction
    • /
    • v.19 no.6
    • /
    • pp.695-702
    • /
    • 2007
  • The Thermal Prestressing Method for continuous composite girder bridges is a new design and construction method developed to induce initial composite stresses in the concrete slab at negative bending regions. Due to the induced initial stresses, prevention of tensile cracks at the concrete slab, reduction of steel girder section, and reduction of reinforcing bars are possible. Thus, the construction efficiency can be improved and the construction can be made more economical. The method for determining the optimum heating region of the thermal prestressing method has not been established although such method is essential for improving the efficiency of the design process. The trial-and-error method used in previous studies is far from efficient, and a more rational method for computing optimal heating region is required. In this study, an efficient method for determining the optimum heating region in using the thermal prestressing method was developed based on the neural network algorithm, which is widely adopted to pattern recognition, optimization, diagnosis, and estimation problems in various fields. Back-propagation algorithm, commonly used as a learning algorithm in neural network problems, was used for the training of the neural network. Through case studies of two-span and three-span continuous composite girder bridges using the developed procedure, the optimal heating regions were obtained.

Study on the Development of Multi Heat Supply Control Algorithm in Apartment Building of District Heating Energy (지역난방 에너지 공동주택의 다중 열공급 제어 알고리즘 개발에 관한 해석적 연구)

  • Byun, J.K.;Choi, Y.D.;Park, M.H.;Shin, J.K.
    • Journal of the Korean Society of Mechanical Technology
    • /
    • v.13 no.2
    • /
    • pp.63-70
    • /
    • 2011
  • In the present study, we developed optimal heat supply algorithm which minimizes the heat loss through the distribution pipe line in group energy apartment. Heating load variation of group energy apartment building in accordance with outdoor air temperature was predicted by the correlation obtained from calorimeter measurements of whole households of apartment building. Supply water temperature and mass flow rate were conjugately controlled to minimize the heat loss rate through distribution pipe line. Group heating apartment located in Hwaseong city, Korea, which has 1,473 households divided in 4 regions, was selected as the object apartment for verifying the present heat supply control algorithm. Compared to the original heat supply system, 10.4% heat loss rate reduction can be accomplished by employing the present control algorithm.

Study on Process Parameters for Effective H2 Production from H2O in High Frequency Inductively Coupled Plasma Reactor (고주파유도결합플라즈마 반응기에서 물로부터 수소생성효율을 높이기 위한 공정변수에 대한 연구)

  • Kwon, Sung-Ku;Jung, Yong-Ho
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.2
    • /
    • pp.206-212
    • /
    • 2011
  • The effect of process parameters on $H_2$ production from water vapor excited by HF ICP has been qualitatively examined for the first time. With the increase of ICP power, characteristics of $H_2$ production from $H_2O$ dissociation in plasma was divided into 3 regions according to both reaction mechanism and energy efficiency. At the edge of region (II) in the range of middle ICP power, energy effective hydrogen production from $H_2O$ plasma can be achieved. Furthermore, within the region (II) power condition, heating of substrate up to $500^{\circ}C$ shows additional increase of 70~80% in $H_2$ production compared to $H_2O$ plasma without substrate heating. This study have shown that combination of optimal plasma power (region II) and wall heating (around $500^{\circ}C$) is one of effective ways for $H_2$ production from $H_2O$.

Design Optimization of Heat Exchangers for Solar-Heating Ocean Thermal Energy Conversion (SH-OTEC) Using High-Performance Commercial Tubes (고성능 상용튜브를 사용한 태양열 가열 해양온도차발전용 열교환기 설계 최적화)

  • Zhou, Tianjun;Nguyen, Van Hap;Lee, Geun Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.40 no.9
    • /
    • pp.557-567
    • /
    • 2016
  • In this study, the optimal design of heat exchangers, including the evaporator and condenser of a solar-heating ocean thermal energy conversion (SH-OTEC), is investigated. The power output of the SH-OTEC is assumed to be 100 kW, and the SH-OTEC uses the working fluid of R134a and high-performance commercial tubes. The surface heat transfer area and the pressure drop were strongly dependent on the number of tubes, as well as the number of tube passes. To solve the reciprocal tendency between the heat transfer area and pressure drop with respect to the number of tubes, as well as the number of tube passes, a genetic algorithm (GA) with two objective functions of the heat transfer area (the capital cost) and operating cost (pressure drop) was used. Optimal results delineated the feasible regions of heat transfer area and operating cost with respect to the pertinent number of tubes and tube passes. Pareto fronts of the evaporator and condenser obtained from multi-objective GA provides designers or investors with a wide range of optimal solutions so that they can select projects suitable for their financial resources. In addition, the surface heat transfer area of the condenser took up a much higher percentage of the total heat transfer area of the SH-OTEC than that of the evaporator.

Development of Optimal Thermal Transfer Calculation Algorithm by Composition of Thermal Transfer Mechanism among Integrated Energy Operators (집단에너지 사업자간의 열연계 메커니즘 구성에 의한 최적 열연계 산정 알고리즘 개발)

  • Kim, Yongha;Kim, Seunghee;Hyeon, Seungyeon
    • Journal of Energy Engineering
    • /
    • v.26 no.4
    • /
    • pp.57-66
    • /
    • 2017
  • Since the heat is not as fast as the electric power and the loss is relatively large compared to the electric power, it is not realistic to operate the thermal transfer system with on operation center like electric power trading. In the case of the Korea District Heating Corporation, where all the thermal transfer are currently being made, only two or four adjacent heat-generating power plants are being the heat trading. Therefore, In this paper, we concluded that it is appropriate to divide the integrated operation center for heat trading into several regions, to operate the hub integrated operation power plant in each region to reflect the characteristics of the heat medium and proposed the thermal transfer mechanism among integrated energy operators. Then, we have developed an algorithm that can optimize the heat transaction for the proposed mechanism and applied it to the actual operators to verify the usefulness of the proposed algorithm.

The Adaptation of Ginseng Production of Semi-arid Environments : The Example of British Columbia, Canada (강우량이 극히 적은 여건에서의 인삼재배의 순응 : 캐나다 브리티쉬 콜롬비아의 실례)

  • Bailey, W.G.
    • Journal of Ginseng Research
    • /
    • v.14 no.2
    • /
    • pp.297-309
    • /
    • 1990
  • Ginseng is renowned for both its medicinal and herbal uses and successful cultivation of Panax ginseng in Asia and Panax Vtiinvtiefolilim in North America has until recently taken place in the native geographical ranges of the plants. As a consequence of the potential high capital return and anticipated increases in consumer consumption, commercial cultivation of American ginseng now occurs well outside the native range of the plant in North America. In fact, the region of greatest expansion of cultivation is in the semi-arid interior region of British Columbia, Canada. Linked with this expansion is the potential domination of the ginseng industry by agricultural corporations. In the interior of British Columbia, the native decidous forest environment of eastern North America is simulated with elevated polypropylene shade and a sllrface covering of straw mulch. The architecture of these environments is designed to permit maximillm machinery useage and to minimize labour requirements. Further, with only a four-year growth cycle, plant densities in the gardens are high. In this hot, semiarid environment, producers believe they have a competitive advantage over other regions in North America because of the low precipitation rates. This helps to minimize atmospheric humidity such that the conditions for fungal disease development are reduced. If soil moisture levels become limited, supplemental water can be provided by irrigation. The nature of the radiation and energy balance regimes of the shade and much environment promotes high soil moistilre levels. Also, the modified environment reduces soil heating. This can result in an aerial environment for the plant that is stressful and a rooting zone environment that is sub-optimal. The challenge of further refining the man modified environment for enhanced plant growth and health still remains.

  • PDF

Processing and Physicochemical Properties of Collagen from Yellowfin Tuna (Thunnus albacares) Abdominal Skin (황다랑어 복부 껍질을 이용한 콜라겐의 제조 및 물리화학적 특성 해석)

  • Yoo, Sung-Jae;Cho, Sueng-Mock;Woo, Jin-Wook;Kim, Sang-Ho;Han, Yoo-Na;Ahn, Ju-Ryun;Kim, Su-Yeon;Kim, Tae-Wan;Kim, Seon-Bong
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.41 no.6
    • /
    • pp.427-434
    • /
    • 2008
  • Processing of collagen from yellowfin tuna (Thunnus albacares) abdominal skins was optimized by response surface methodology and central composite design. The values of independent variables at optimal conditions were NaOH concentration: 0.5 N, NaOH treatment time: 36.2 hr, pepsin concentration: 1:4.9 ratio (0.245%, w/v), and digestion time: 48.1 hr, respectively. The collagen content estimated under optimal conditions was 33.1%, and the actual experimental collagen content was 32.3%. Physicochemical properties of collagen from yellowfin tuna abdominal skin were investigated by amino acids analysis, SDS-PAGE, FT-IR, viscosity and denaturation temperature. Amino acids content of the collagen was 21.0%. SDS-PAGE pattern of the collagen showed two different $\alpha$-chain (${\alpha}_1$- and ${\alpha}_2$- chain), $\beta$-component and $\gamma$-component. The spectrum of FT-IR of the collagen showed wavenumber at 3,434, 1,650, 1,542 and $1,235\;cm^{-1}$ representing the regions of amide A, I, II and III, respectively. Relative viscosity of the collagen decreased continuously on heating up to $32^{\circ}C$, and the rate of decrease was retarded in the temperature range of $35-50^{\circ}C$. Denaturation temperature (Td) of the collagen solution (0.06%, w/v) was $31^{\circ}C$ and was lower than calf skin collagen ($35^{\circ}C$).