• 제목/요약/키워드: optimal friction damper force

검색결과 14건 처리시간 0.022초

레일의 운동마찰력을 고려한 TMD 최적 설계 (Optimal design of tuned mass damper considering the friction between the moving mass and the rail)

  • 이상현;우성식;조승호;정란
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.582-587
    • /
    • 2007
  • In this study, based on the results from the sinusoidal base excitation analyses of a single degree of freedom system with a tuned mass damper (TMD), it is verified that optimal friction force can improve the performance of a TMD like a linear viscous damper which has been usually used in general TMD. The magnitude of the optimal friction increases with increasing mass ratio of the TMD and decreases with increasing structural damping. Particularly, it is observed that the optimized friction force gives better control performance than the optimized viscous damping of the TMD. However, because the performance of the TMD considerably deteriorates when the friction force increases over the optimal value, it is required to keep the friction force from exceeding the optimal value.

  • PDF

레일의 운동마찰력을 고려한 TMD 최적 설계 (Optimal Design of Tuned Mass Damper Considering the Friction between the Moving Mass and the Rail)

  • 이상현;우성식;조승호;정란
    • 한국소음진동공학회논문집
    • /
    • 제17권6호
    • /
    • pp.553-559
    • /
    • 2007
  • In this study, based on the results from the sinusoidal base excitation analyses of a single degree of freedom system with a tuned mass damper (TMD), it is verified that optimal friction force can improve the performance of a TMD like a linear viscous damper which has been usually used in general TMD. The magnitude of the optimal friction increases with increasing mass ratio of the TMD and decreases with increasing structural damping. Particularly, it is observed that the optimized friction force gives better control performance than the optimized viscous damping of the TMD. However, because the performance of the TMD considerably deteriorates when the friction force increases over the optimal value, it is required to keep the friction force from exceeding the optimal value.

Dynamic response of adjacent structures connected by friction damper

  • Patel, C.C.;Jangid, R.S.
    • Earthquakes and Structures
    • /
    • 제2권2호
    • /
    • pp.149-169
    • /
    • 2011
  • Dynamic response of two adjacent single degree-of-freedom (SDOF) structures connected with friction damper under base excitation is investigated. The base excitation is modeled as a stationary white-noise random process. As the force-deformation behavior of friction damper is non linear, the dynamic response of connected structures is obtained using the equivalent linearization technique. It is observed that there exists an optimum value of the limiting frictional force of the damper for which the mean square displacement and the mean square absolute acceleration responses of the connected structures attains the minimum value. The close form expressions for the optimum value of damper frictional force and corresponding mean square responses of the coupled undamped structures are derived. These expressions can be used for initial optimal design of the friction damper for connected structures. A parametric study is also carried out to investigate the influence of system parameters such as frequency ratio and mass ratio on the response of the coupled structures. It has been observed that the frequency ratio has significant effect on the performance of the friction damper, whereas the effects of mass ratio are marginal. Finally, the verification of the derived close from expressions is made by correlating the response of connected structures under real earthquake excitations.

Multi-mode cable vibration control using MR damper based on nonlinear modeling

  • Huang, H.W.;Liu, T.T.;Sun, L.M.
    • Smart Structures and Systems
    • /
    • 제23권6호
    • /
    • pp.565-577
    • /
    • 2019
  • One of the most effective countermeasures for mitigating cable vibration is to install mechanical dampers near the anchorage of the cable. Most of the dampers used in the field are so-called passive dampers where their parameters cannot be changed once designed. The parameters of passive dampers are usually determined based on the optimal damper force obtained from the universal design curve for linear dampers, which will provide a maximum additional damping for the cable. As the optimal damper force is chosen based on a predetermined principal vibration mode, passive dampers will be most effective if cable undergoes single-mode vibration where the vibration mode is the same as the principal mode used in the design. However, in the actual engineering practice, multi-mode vibrations are often observed for cables. Therefore, it is desirable to have dampers that can suppress different modes of cable vibrations simultaneously. In this paper, MR dampers are proposed for controlling multi-mode cable vibrations, because of its ability to change parameters and its adaptability of active control without inquiring large power resources. Although the highly nonlinear feature of the MR material leads to a relatively complex representation of its mathematical model, effective control strategies can still be derived for suppressing multi-mode cable vibrations based on nonlinear modelling, as proposed in this paper. Firstly, the nonlinear Bouc-wen model is employed to accurately portray the salient characteristics of the MR damper. Then, the desired optimal damper force is determined from the universal design curve of friction dampers. Finally, the input voltage (current) of MR damper corresponding to the desired optimal damper force is calculated from the nonlinear Bouc-wen model of the damper using a piecewise linear interpolation scheme. Numerical simulations are carried out to validate the effectiveness of the proposed control algorithm for mitigating multi-mode cable vibrations induced by different external excitations.

응답 의존형 MR 감쇠기의 성능 평가 (Performance Evaluation of Response-Dependent MR Damper)

  • 이상현;민경원;윤경조
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.511-518
    • /
    • 2006
  • In this study, seismic response mitigation effect of an MR damper generating response-dependent frictional force is investigated. It has been reported in previous studies that passively operated MR damper with constant input current doesn't show better control performance than semi-active MR damper with varying input current calculated by control algorithms such as linear quadratic regulator and sliding mode control. However, in order to operate the MR damper semi-actively, other control systems besides the damper itself such as sensors for measuring structural responses and controller for calculating optimal input current are necessary, which deteriorate the economical efficiency. This study presents a MR damper generating frictional force of which magnitude is controlled in accordance to the displacement and velocity transferred to the damper. Numerical analyses results indicate that the performance of the response dependent MR damper is closely related with the range of the friction force and it can be designed to short better control performance than the passive MR damper.

  • PDF

전단벽식 구조의 휨거동을 이용한 마찰감쇠기의 제어성능 (Control Performance of Friction Dampers Using Flexural Behavior of RC Shear Wall System)

  • 정희산;문병욱;박지훈;이성경;민경원;변지석
    • 한국소음진동공학회논문집
    • /
    • 제18권8호
    • /
    • pp.856-863
    • /
    • 2008
  • High-rise apartments of shear wall system are governed by flexural behavior like a cantilever beam. Installation of the damper-brace system in a structure governed by flexural behavior is not suitable. Because of relatively high lateral stiffness of the shear wall, a load is not concentrate on the brace and the brace cannot perform a role as a damping device. In this paper, a friction damper applying flexibility of shear wall is proposed in order to reduce the deformation of a structure. To evaluate performance of the proposed friction damper, nonlinear time history analysis is executed by SeismoStruct analysis program and MVLEM(multi vertical linear element model) be used for simulating flexural behavior of the shear wall. It is found that control performance of the proposed friction damper is superior to one of a coupled wall with rigid beam. In conclusion, this study verified that the optimal control performance of the proposed friction damper is equal to 45 % of the maximum shear force inducing in middle-floor beam with rigid beam.

회전마찰감쇠기의 등가선형시스템에 관한 실험적 연구 (Experimental Study on Equivalent Linear System for Rotational friction Damper)

  • 김형섭;박지훈;민경원;이상현;이명규
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.296-303
    • /
    • 2004
  • In this study, equivalent linear damping and stiffness of a single-degree-of-freedom (SDOF) structure with a rotational friction damper are estimated using the result of experiments and compared with those obtained from non-linear time history analyses. First, the transfer function of the test model is constructed and then the equivalent stiffness and damping are calculated, using the half-power bandwidth (HPB) method. For comparative study, those properties are estimated based on stochastic theory in the time domain. Both equivalent linear systems identified from experiments and numerical analyses correspond well. Further, it is observed that there exists an optimal clamping force on the rotational friction damper from estimated equivalent damping.

  • PDF

Seismic response control of a building complex utilizing passive friction damper: Analytical study

  • Ng, C.L.;Xu, Y.L.
    • Structural Engineering and Mechanics
    • /
    • 제22권1호
    • /
    • pp.85-105
    • /
    • 2006
  • Control of structural response due to seismic excitation in a manner of coupling adjacent buildings has been actively developed, and most attention focused on those buildings of similar height. However, with the rapid development of some modern cities, multi-story buildings constructed with an auxiliary low-rise podium structure to provide extra functions to the complex become a growing construction scheme. Being inspired by the positively examined coupling control approach for buildings with similar height, this paper aims to provide a comprehensive analytical study on control effectiveness of using friction dampers to link the two buildings with significant height difference to supplement the recent experimental investigation carried out by the writers. The analytical model of a coupled building system is first developed with passive friction dampers being modeled as Coulomb friction. To highlight potential advantage of coupling the main building and podium structure with control devices that provide a lower degree of coupling, the inherent demerit of rigid-coupled configuration is then evaluated. Extensive parametric studies are finally performed. The concerned parameters influencing the design of optimal friction force and control efficiency include variety of earthquake excitation and differences in floor mass, story number as well as number of dampers installed between the two buildings. In general, the feasibility of interaction control approach applied to the complex structure for vibration reduction due to seismic excitation is supported by positive results.

마찰 에너지 소산과 자동 복원력을 활용한 가새 댐퍼 시스템의 최적 설계와 구조적 활용 (Optimum Design and Structural Application of the Bracing Damper System by Utilizing Friction Energy Dissipation and Self-Centering Capability)

  • 허종완;박지웅
    • 대한토목학회논문집
    • /
    • 제34권2호
    • /
    • pp.377-387
    • /
    • 2014
  • 본 연구는 지진에 대한 구조물의 손상을 최소화 하기 위하여 슬립 저항력을 활용한 새로운 형태의 마찰 댐퍼형 가새 시스템의 설계와 개발을 주로 다루고자 한다. 가새 부재 내에서 전단력에 의한 마찰 거동으로 상당량의 에너지를 수동적으로 소산하기 위하여 플레이트 전단 이음부 위에 슬롯 형태의 볼트 구멍을 설치한다. 여기에 전단 마찰 거동으로 인해 발생되는 잔류변형을 줄이고자 상온에서 원형복원이 가능한 초탄성 형상합금 와이어를 꼬아서 만든 연선을 설치하여 댐퍼 시스템 내에 복원성을 증진 시켰다. 기존에 주로 사용된 수동적인 변위 제어 장치와 비교하여 본 연구에서 다루고자 하는 자동복원이 가능한 마찰 댐퍼형 가새 시스템은 중심 가새 프레임 구조물에 손쉽게 설치하여 지진발생 후에 구조물에 발생하는 층간 잔류변위를 최소화하여 유지 보수에 소모되는 비용의 대폭적인 절감을 기대할 수 있다. 본 연구에서는 자동복원이 가능한 마찰 댐퍼형 가새 시스템의 역학적인 거동 메커니즘을 살펴보고 실험값으로 보정되어 신뢰성을 확보한 스프링 모델을 사용하여 해석을 실시하였다. 시스템에 다양한 설계 변수를 적용하여 복원성과 에너지 소산 능력 측면에서 제안된 댐퍼의 성능 동향을 분석을 하고 최적의 설계 방식을 제안하고자 한다. 마지막으로 자동복원이 가능한 마찰 댐퍼를 중심 가새 프레임 구조물에 설치하여 비선형 동적 해석을 실시하고 기존의 시스템과 비교하여 성능적인 우수성을 입증하고자 한다.

케이블 진동 감쇠를 위한 반능동 제어 장치 성능의 실험적 평가 (Experimental Verification of Semiactive Control Systems for Stay Cable Vibration)

  • 장지은;정형조;정운;이인원
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2004년도 가을 학술발표회 논문집
    • /
    • pp.52-59
    • /
    • 2004
  • In this paper, the efficacy of the MR damper-based control systems for vibration suppression of stay cables has been experimentally investigated. The performance of the several control strategies for the semiactive control system, such as the clipped-optimal control, the Lyapunov stability theory-based control, the maximum energy dissipation and the modulated homogeneous friction, has been compared with that of the passive-type control systems employing MR dampers. To do this, the full-scale stay cable, which is the same as used for the in-service cable-stayed bridge in Korea, is considered. The acceleration and the displacement of the stay cable as well as the damping force of the MR damper are measured. The velocity of the cable at the damper location, which is needed for some control algorithms, is obtained by differentiating the measured displacement. The damping ratios of the cable system employing the MR damper, which can be estimated by the Hilbert transform-based method, shows effectiveness of each control strategy considered.

  • PDF