• Title/Summary/Keyword: optical scanning

Search Result 1,615, Processing Time 0.025 seconds

Optical Scanning Holographic Approach to Three-Dimensional Television

  • Poon, Ting-Chung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2002.08a
    • /
    • pp.281-284
    • /
    • 2002
  • We first review a real-time holographic recording technique called optical scanning holography (OSH) and discuss holographic reconstruction using spatial light modulators (SLMs). We then present how the overall system can be used for three-dimensional (3-D) holographic television (TV) system and address some of the issues encountered. Finally, we suggest some techniques to alleviate the issues encountered in such a 3-D holographic TV.

  • PDF

Development of high-speed near-field scanning optical microscopy by using a high-frequency quartz-crystal resonator (고주파 수정진동자를 이용한 고속 근접장 광학 현미경 제작)

  • 서용호;제원호
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2001.02a
    • /
    • pp.120-121
    • /
    • 2001
  • 고분해능을 장점으로 하는 근접장 광학 현미경(NSOM)은 최근 높은 관심을 모으고 있으나, 그 촬영 속도가 너무 느린 이유로 실제적인 활용이 미비한 상황이다. scanning 속도를 높이고자 하는 노력들이 많이 진행되고 있으나[1-2] 아직도 실시간 촬영과는 거리가 멀다. 기존의 근접장 광학 현미경(NSOM)은 tuning fork를 사용하여 탐침을 진동시키고 그 진동의 진폭 또는 위상의 변화를 측정함으로써 탐침과 시료의 거리를 측정하는 방식을 사용한다. (중략)

  • PDF

8 Beam Laser Diode Development for Laser Scanning Unit (Laser Scanning Unit을 위한 8빔 레이저 다이오드 개발)

  • Song, Dae-Gwon;Park, Jong-Keun;Kim, Jae-Gyu;Park, Jung-Hyun;So, Sang-Yang;Kwak, Yoon-Seok;Yang, Min-Sik;Choi, An-Sik;Kim, Tae-Kyung
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.3
    • /
    • pp.111-117
    • /
    • 2010
  • A 780 nm monolithic individually addressable 8-beam diode laser with 10mW optical power was developed for use in a laser scanning unit. Beam to beam spacing is $30\;{\mu}m$ and an air bridge interconnection process was developed for individual operations. From electrical and optical characteristic measurements, the developed device is a suitable optical source for a high speed laser scanning unit in multi-function printing systems and laser beam printers.

Use of an Optical Scanning Device to Monitor the Progress of Noninvasive Treatments for Chest Wall Deformity: A Pilot Study

  • Kelly, Robert E. Jr.;Obermeyer, Robert J.;Kuhn, M. Ann;Frantz, Frazier W.;Obeid, Mohammad F.;Kidane, Nahom;McKenzie, Frederic D.
    • Journal of Chest Surgery
    • /
    • v.51 no.6
    • /
    • pp.390-394
    • /
    • 2018
  • Background: The nonsurgical treatment of chest wall deformity by a vacuum bell or external brace is gradual, with correction taking place over months. Monitoring the progress of nonsurgical treatment of chest wall deformity has relied on the ancient methods of measuring the depth of the excavatum and the protrusion of the carinatum. Patients, who are often adolescent, may become discouraged and abandon treatment. Methods: Optical scanning was utilized before and after the intervention to assess the effectiveness of treatment. The device measured the change in chest shape at each visit. In this pilot study, patients were included if they were willing to undergo scanning before and after treatment. Both surgical and nonsurgical treatment results were assessed. Results: Scanning was successful in 7 patients. Optical scanning allowed a visually clear, precise assessment of treatment, whether by operation, vacuum bell (for pectus excavatum), or external compression brace (for pectus carinatum). Millimeter-scale differences were identified and presented graphically to patients and families. Conclusion: Optical scanning with the digital subtraction of images obtained months apart allows a comparison of chest shape before and after treatment. For nonsurgical, gradual methods, this allows the patient to more easily appreciate progress. We speculate that this will increase adherence to these methods in adolescent patients.

A Study on the Curvature Correction in Laser Scanner (레이저 주사 장치의 곡률 보정에 관한 연구)

  • Yun, N.I.;Kim, N.;Park, H.K.
    • Proceedings of the Korean Institute of Communication Sciences Conference
    • /
    • 1986.10a
    • /
    • pp.194-197
    • /
    • 1986
  • In this paper, for the curvature correction on the scanning plane in laser scanning system, aberration correction method using holographic optical element is suggested. Holoens is selected as a type of holographic zone plate which has aberration correction property. And hologram recording condition is analyzed to find fo property. This hololens is implemented by computer-generated hologram technique. Laser scanning system is organized using desinged hololens and scanning properties of this system are investigated. Using this method optical system structure in laser scanning system can be simplified satisfying both scan linearity and field flatness.

  • PDF

Endoscopic Precise 3D Surface Profiler Based on Continuously Scanning Structured Illumination Microscopy

  • Park, Hyo Mi;Joo, Ki-Nam
    • Current Optics and Photonics
    • /
    • v.2 no.2
    • /
    • pp.172-178
    • /
    • 2018
  • We propose a precise 3D endoscopic technique for medical and industrial applications. As the 3D measuring principle, the continuously scanning structured illumination microscopy (CSSIM), which enables to obtain 3D sectional images by the synchronous axial scanning of the target with the lateral scanning of the sinusoidal pattern, is adopted. In order to reduce the size of the probe end, the illumination and detection paths of light are designed as coaxial and a coherent imaging fiber bundle is used for transferring the illumination pattern to the target and vice versa. We constructed and experimentally verified the proposed system with a gauge block specimen. As the result, it was confirmed that the 3D surface profile was successfully measured with $16.1{\mu}m$ repeatability for a gauge block specimen. In order to improve the contrast of the sinusoidal illumination pattern reflected off on the target, we used polarizing optical components and confirmed that the visibility of the pattern was suitable in CSSIM.

Proposal and design of reflecting optical system to improve detection intensity in fluorescence confocal scanning microscopy (형광 공초점 주사 현미경의 측정 강도 향상을 위한 반사 광학계의 제안 및 설계)

  • 강동균;서정우;권대갑
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.187-190
    • /
    • 2002
  • Confocal microscopy is very popular technology in bio-medical inspection due to its ability to reject background signals and to measure very thin slide of thick specimens, which is called optical sectioning. But intensity of detected signal in fluorescence type confocal microscopy is so small that only 0.2% of emitted fluorescence light can be detected in the best case. In this paper, we proposed the reflecting optical system to improve the detection intensity and designed the optical system by optimal design method. At the end of the paper, we analyzed the characteristics of the proposed reflecting optical system.

  • PDF

Precision Position and Gap Control for High Density Optical Head Using Bimorph PZT (Bimorph PZT를 이용한 고밀도 광학헤드의 정밀위치 및 간극제어)

  • 권영기;홍어진;박태욱;박노철;양현석;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.888-893
    • /
    • 2004
  • This paper proposed a dual actuator using bimorph PZT for information storage device based on prove array NSOM(Near-field Scanning Optical Microscopy). The gap between the media and the optical head should be maintained within the optical tolerance. Therefore, a new actuator having high sensitivity is required. Bimorph PZT, which has fast access time and high sensitivity characteristic, is suitable for this precise actuating system. This paper is focused on derivation of mathematical model of dual bimorph PZT actuator and control algorithm. Hamilton's principle was used for mathematical model. The model is verified by FEA(Finite Element Analysis), and compared with experimental results. Different control algorithms were used f3r two bimorph PZT actuating same direction and opposite direction. The gap between recording media and optical head was controlled within 20nm in experiment.

  • PDF

Reflection-type Optical Waveguide Index Profiling Technique

  • Youk YoungChun;Kim Dug Young
    • Journal of the Optical Society of Korea
    • /
    • v.9 no.2
    • /
    • pp.49-53
    • /
    • 2005
  • We report a new configuration of a reflection-type confocal scanning optical microscope system for measuring the refractive index profile of an optical waveguide. Several improvements on the earlier design are proposed; a light emitting diode (LED) at 650 nm wavelength instead of a laser diode (LD) or He-Ne laser is used as a light source for better index precision, and a simple longitudinal linear scanning and curve fitting techniques are adapted instead of a servo control for maintaining an optical confocal arrangement. We have obtained spatial resolution of 700 nm and an index precision of $2\times10^{-4}$. To verify the system's capability, the refractive index profiles of a conventional multimode fiber and a home-made four-mode fiber were examined with our proposed measurement method.

Compensations of Polarization Mode Dispersion and Thermal Drift in Optical Coherence Tomography with PZT Optical Delay Lines (광간섭 단층촬영(OCT)용 PZT 광경로 지연기에서의 편광모드 분산 및 열요동 보상)

  • Kim, Young-Kwan;Park, Sung-Jin;Kim, Yong-Pyung
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.547-552
    • /
    • 2005
  • We have fabricated and characterized optical delay lines for optical coherence tomography, which is composed of cylindrical PZT(piezoelectric transducer) and single mode optical fiber. The polarization mode dispersion from the optical delay lines was compensated by the polarization controllers. By applying the duplex optical delay line, we minimized the thermal drift due to optical delay lines and obtained the scan range of 2 times that of a single optical delay line. The OCT system showed resolution of $18.6\pm0.5{\mu}m$, scanning range of 1.68mm, and scanning speed of 360.4mm/s.