• Title/Summary/Keyword: optical media

Search Result 531, Processing Time 0.021 seconds

Fine Seek Control of Extended Applicable Range for Optical Disk Drives

  • Ryoo, Jung-Rae;Jin, Kyoung-Bog;Doh, Tae-Young;Chung, Myung-Jin
    • Transactions on Control, Automation and Systems Engineering
    • /
    • v.3 no.3
    • /
    • pp.146-151
    • /
    • 2001
  • Optical disk drive has excellent advantage of random accessibility of which performance is measured by access time. However, due to the increased rotational velocity of the disk and constraints of mechanical structure, two-stage seek algorithm which executes coarse and fine seeks sequentially has been adopted in most commercial optical disk drives. Although the laser spot is moved to a target track by a single seek operation, the limited operation range of the fine actuator restricts the application of the fine seek algorithm below a few hundreds of tracks. Especially, excessive movement of the objective lens causes a failure in generation of track-cross pulse and results in an unstable seek operation. In this paper, a new control algorithm for extending the fine seek range is proposed with an appropriate control structure. The coarse actuator is utilized to reduce the misalignment between the objective lens and the laser beam axis, and the fine actuator is controlled to follow the reference velocity trajectory. The proposed algorithm is applied to a CD-ROM drive to show its feasibility and some experimental results are presented.

  • PDF

Design of Optical Biological Sensor for Phycocyanin Parameters Measurement using Fluorescence Technique

  • Lee, Sung Hwa;Mariappan, Vinayagam;Won, Dong Chan;Ann, Myungsuk;Yang, Seungyoun
    • International journal of advanced smart convergence
    • /
    • v.5 no.2
    • /
    • pp.73-79
    • /
    • 2016
  • Remote sensing and measurement are of paramount importance of providing information on the state of water quality in water bodies. The formation and growth of cyanobacteria is of serious concern to in land aquatic life forms and human life. The main cause of water quality deterioration stems from anthropogenic induced eutrophication. The goal of this research to quantify and determine the spatial distribution of cyanobacteria concentration in the water using remote sensing technique. The standard approach to measure water quality based on the direct measurement of the fluorescence of the chlorophyll a in the living algal cells and the same approach used to detect the phycobilin pigments found in blue-green algae (a.k.a. cyanobacteria), phycocyanin and phycoerythrin. This paper propose the emerging sensor design to measure the water quality based on the optical analysis by fluorescence of the phycocyanin pigment. In this research, we developed an method to sense and quantify to derive phycocyanin intensity index for estimating cyanobacteria concentrations. The development of the index was based on the reflectance difference between visible light band 620nm and 665nm. As a result of research this paper presents, an optical biological sensor design information to measure the Phycocyanin parameters in water content.

An Anti-vibration Design of Slim-type Optical Disk Drive (슬림형 광 디스크 드라이브의 방진설계)

  • Kim, Nam-Woong;Kim, Kug-Weon;Hong, Goo;Chung, Mun-Chae;Kim, Wae-Yeul
    • Journal of KSNVE
    • /
    • v.9 no.2
    • /
    • pp.324-330
    • /
    • 1999
  • With the increase of track density, high rotational speed and the compatibility for various media such as CD-ROM, CD-R/RW, DVD-ROM/RAM/RW etc. in optical disk drive, the effective anti-vibration design is so crucial for robust operaton. Especailly when the drive is self-excited by unbalanced disk, internal sled base vibration and its external transmission to the case bring about so severe problem. Generally these two consideration points the practical anti-vibration design process to control thses two conflictive properties using finite element analysis. As an example of the design process, Duro 25 and 40 visco-elastic rubber mount was selected and analyzed. The stiffness obtained from FEM rubber model was well matched with the experiments. Also it was confirmed that the internal and external vibration induced from unbalanced disk have good agreement with experimental results. The proposed design process is adopted to the slim-type optical disk drive.

  • PDF

Polarization Analysis of Light Passing Through Non-uniform Uniaxial Media (비균일 단축 이방성 매질을 투과하는 빛의 편광상태 변화 표현)

  • Ryu, Jang-Wi;Kim, Sang-Youl;Kim, Yong-Ki
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.161-167
    • /
    • 2010
  • We suggest an effective expression of transmission coefficients between uniaxial anisotropic media. To study the transmission of oblique incident light by stratified anisotropic planar structures, we included an imaginary isotropic layer sandwiched between those anisotropic media, and then considered multiple reflection within the imaginary layer. The adequacy of this expression is confirmed by comparing the polarization analysis of light passing through the anisotropic medium and the multi.layered anisotropic media.

Design and Analysis of Continuous Media Representation Mechanism to minimize the Variance of Latency Time (지연시간의 변화를 고려한 연속미디어 표현 메카니즘의 설계 및 분석)

  • Yeo, In-Kook;Hwang, Dae-Hoon
    • The Transactions of the Korea Information Processing Society
    • /
    • v.2 no.5
    • /
    • pp.787-796
    • /
    • 1995
  • In this paper, a mechanism to enhance the utilization of the tertiary storage devices such as optical disk, digital tape and so on is proposed. For this purpose, we suggest a storage structure with a CD-ROM and multiple disk and design an efficient mechanism to represent the continuous media stored in CD-ROM. The continuous media storage structure proposed in this pater can enhanced the retrieval capability of information by sending data using a shared bus with high bandwidth. And a continuous media representation mechanism not only can reduce the discontinuity of representation using parallel operation of fetch and representation but also minimize the variance of service time and the missing ratio of re-reference requirement by residing frequently accessed object on the disk.

  • PDF

Direct Seek Control for Swing-arm Type Dual Stage Actuators in Blu-Ray Disc Drive Systems

  • Ryu, Shi-Yang;Jung, Soo-Yul;Yoon, Hyeong-Deok;Park, In-Shik
    • Proceedings of the KIEE Conference
    • /
    • 2003.11c
    • /
    • pp.735-739
    • /
    • 2003
  • This paper presents a direct seek control algorithm for swing-arm type dual stage servo system that consists of a coarse actuator and a fine actuator. The proposed scheme is to design a control system that attenuates the effect of dynamic coupling between the two actuators so that the seek operation can be performed in a single-shot with stability. In an optical drive system with dual stage servo mechanism, the effect of dynamic coupling between the two actuators needs to be handled during the coarse seek operation due to its inherent structure. In an extreme case, the two actuators can collide each other, which leads to critical degradation of the seek performance. To handle this problem, our proposed control scheme is to generate the drive signals such that the two actuators behave as if they are a single fixed body. To this end, a feedforward controller and two feedback controllers are designed that enable the current drive system perform wide range of track seek. Simulation results are provided to show the validity and feasibility of our proposed algorithm.

  • PDF

Studies on the Wave Propagation and Fluctuation in Randomly Ditribution Media of L-Aspartic Acid (L-Aspartic Acid의 무질서하게 분포된 매질에서 파동전개와 변동에 관한 연구)

  • Kim, Ki-Jun;Lee, Joo-Youb
    • Journal of the Korean Applied Science and Technology
    • /
    • v.29 no.1
    • /
    • pp.122-128
    • /
    • 2012
  • The influences of fluorescence, scattering, and flocculation in turbid material by light scattering of L-aspartic acid, preservative and emulsifier were interpreted for the scattered fluorescence intensity and wavelength. They have been studied the molecular properties by the spectroscopy of laser induced fluorescence (LIF) and flocculation. The effects of optical properties in scattering media have been found by the optical parameters(${\mu}_s$, ${\mu}_a$, ${\mu}_t$). Flocculation is an important step in many solid-liquid separation processes and is widely used. When two particles approach each other, interactions of several colloid particles can come into play which may have major effect on the flocculation and LIF process. The values of scattering coefficient ${\mu}_s$ are large by means of the increasing scattering of scatterer, The values have been found that the slope decays exponentially as a function of concentration from laser source to detector by our experimental result. It may also aid in designing the best model for oil chemistry, bio-pharmaceutical products, laser medicine and application of medical engineering on LIF and coagulation in particle transport mode.

A Study on the Measurements of Beam Wave Propagation and Fluorescence Spectroscopy in Particles Media (입자매질에서 빔파동전파와 형광분광 측정에 관한 연구)

  • Kim, Ki-Jun;Lee, Jou-Youb;Sung, Wan-Mo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.31 no.2
    • /
    • pp.167-175
    • /
    • 2014
  • The influences of fluorescence, scattering, and flocculation in turbid material were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by the spectroscopy of laser induced fluorescence(LIF). The effects of optical properties in scattering media have been found by the optical parameters(${\mu}_s$, ${\mu}_a$, ${\mu}_t$). Flocculation is an important step in many solid-liquid separation processes and is widely used in Photodynamic therapy. The interactions of several colloid particles can come into play which have major effect on the flocculation and LIF process. We measured scattering and fluorescence spectra of the sample for in vitro as function of concentration from lase source to detector. The value of scattering coefficient ${\mu}_s$ is large by means of the increasing particles of scatterer. Therefore, Phorphyrin A is larger than Phorphyrin C in scattering intensity ${\mu}_s$, but Phorphyrin A is smaller than Phorphyrin C in penetration depth ${\delta}$.

A Study on Wave Propagation and Scattering in Purple Membrane and β-carotene (Purple Membrane과 β-carotene에서 산란과 파동전파에 관한 연구)

  • Kim, Ki-Jun;Park, Tae-Sul;Sung, Wan-Mo
    • Journal of the Korean Applied Science and Technology
    • /
    • v.33 no.1
    • /
    • pp.136-142
    • /
    • 2016
  • The influences of fluorescence, scattering, and flocculation in random media were interpreted for the scattered fluorescence intensity and wavelength, it has been studied the molecular properties by the spectroscopy of laser induced fluorescence(LIF). The effects of optical properties in scattering media have been found by the optical parameters(${\mu}_s$, ${\mu}_a$, ${\mu}_t$). Flocculation is an important step in many solid-liquid separation processes and is widely used in Photodynamic therapy. The interactions of several colloid particles can come into play which have major effect on the flocculation and LIF process. We measured scattering and fluorescence spectra of the sample in vitro as function of distance from lase source to detector. The value of scattering coefficient ${\mu}_s$ is and ${\beta}$-carotene were measured as larger values(I, ${\delta}$) by means of closer distance from source to detector.

Spectrofluorimetric Determination of Pb ion in Aqueous Media Using an Optical Sensor (광센서를 이용한 수용액 중 납이온의 형광분광법적 정량)

  • Lee, Sang Hak;Seo, Hyo Suk
    • Journal of the Korean Chemical Society
    • /
    • v.46 no.5
    • /
    • pp.407-411
    • /
    • 2002
  • A method to determine lead ion in aqueous media using an optical sensor loaded on a fluorescent optode membrane incoporating a metal ion-selective ionophore, a proton-selective chromoionophore and lipophilic anionic sites has been studied. The effects of pH and thickness of membrane on the fluorescence intensity were investigated. The effects of foreign ions such as $Na^+$, $K^+$, $Mn^{2+}$ and $Zn^{2+}$ on the determination of lead ion were also studied. The linear range in the calibration curve for the determination of lead ion was found to be 5.0${\times}10^-7$ to 5.0${\times}$$10^-3$M and the correlation coefficient in this range was -0.99107 under the optimal experimental conditions. The relative standard deviation of the blank signals was 3.0% and the detection limit of lead ion was 5.0${\times}$$10^-9$M.