• 제목/요약/키워드: optical media

Search Result 530, Processing Time 0.025 seconds

OWC based Smart TV Remote Controller Design Using Flashlight

  • Mariappan, Vinayagam;Lee, Minwoo;Choi, Byunghoon;Kim, Jooseok;Lee, Jisung;Choi, Seongjhin
    • International Journal of Internet, Broadcasting and Communication
    • /
    • v.10 no.1
    • /
    • pp.71-76
    • /
    • 2018
  • The technology convergence of television, communication, and computing devices enables the rich social and entertaining experience through Smart TV in personal living space. The powerful smart TV computing platform allows to provide various user interaction interfaces like IR remote control, web based control, body gesture based control, etc. The presently used smart TV interaction user control methods are not efficient and user-friendly to access different type of media content and services and strongly required advanced way to control and access to the smart TV with easy user interface. This paper propose the optical wireless communication (OWC) based remote controller design for Smart TV using smart device Flashlights. In this approach, the user smart device act as a remote controller with touch based interactive smart device application and transfer the user control interface data to smart TV trough Flashlight using visible light communication method. The smart TV built-in camera follows the optical camera communication (OCC) principle to decode data and control smart TV user access functions according. This proposed method is not harmful as radio frequency (RF) radiation does it on human health and very simple to use as well user does need to any gesture moves to control the smart TV.

Multi-Region based Radial GCN algorithm for Human action Recognition (행동인식을 위한 다중 영역 기반 방사형 GCN 알고리즘)

  • Jang, Han Byul;Lee, Chil Woo
    • Smart Media Journal
    • /
    • v.11 no.1
    • /
    • pp.46-57
    • /
    • 2022
  • In this paper, multi-region based Radial Graph Convolutional Network (MRGCN) algorithm which can perform end-to-end action recognition using the optical flow and gradient of input image is described. Because this method does not use information of skeleton that is difficult to acquire and complicated to estimate, it can be used in general CCTV environment in which only video camera is used. The novelty of MRGCN is that it expresses the optical flow and gradient of the input image as directional histograms and then converts it into six feature vectors to reduce the amount of computational load and uses a newly developed radial type network model to hierarchically propagate the deformation and shape change of the human body in spatio-temporal space. Another important feature is that the data input areas are arranged being overlapped each other, so that information is not spatially disconnected among input nodes. As a result of performing MRGCN's action recognition performance evaluation experiment for 30 actions, it was possible to obtain Top-1 accuracy of 84.78%, which is superior to the existing GCN-based action recognition method using skeleton data as an input.

THE EFFECT OF XYLITOL AND CARBOHYDRATES ON THE REPLICATION OF STREPTOCOCCUS ORALS AND STREPTOCOCCUS SALIVARIUS (자일리톨과 탄수화물이 Streptococcus oralis와 Streptococcus salivarius의 증식에 미치는 영향)

  • Yang, Kyu-Ho;Han, Su-Ji
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.30 no.4
    • /
    • pp.722-727
    • /
    • 2003
  • Xylitol is a 5-carbons carbohydrate, which can be replaced with sucrose for preventing caries. The effect of carbohydrates and their combinations with xylitol was studied for the replication of oral bacteria such as Streptococcus oralis and Streptococcus salivarius. The replication of Streptococcus oralis and Streptococcus salivarius was inhibited according to the increased concentration of xylitol. When Streptococcus oralis was incubated for 8 hours in the media added with lactose or sucrose, the optical density was 0.915 and 1.107, repectively. while being 0.127 and 0.104, respectively in the media combined with xylitol. When Streptococcus salivarius was incubated for 8 hours in the media added with lactose or fructose, the optical density was 1.550 and 0.420, repectively. while being 0.271 and 0.905, respectively in the media combined with xylitol. These results indicated that the replication of Streptococcus oralis and Streptococcus salivarius was changed according to kinds of carbohydrates and combined addition of xylitol.

  • PDF

DEVELOPMENT OF A STORAGE SYSTEM FOR THE TREATMENT DATA AND IMAGE DATA IN DENTISTRY USING THE OPTICAL LASER CARD (광 카드를 이용한 치과 진료자료 및 영상자료 저장 system 개발)

  • Shin, Yong-Pil;Lee, Chan-Young
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.1
    • /
    • pp.110-140
    • /
    • 1998
  • One of the problems facing in all modern dental hospitals is the much efforts, manpower and space are needed to effectively sort and stack patients' charts of the various dental departments. In addition, the storage and prompt arrangement of x-ray films is also a problem. Therefore, if dental charts as well as films could be computerized, it would be easier to store and keep them; by data basing, many space, manpower and cost would be saved: data could also be effectively managed for the purpose of academic researches. This would be an epoch -making event in the development of dental hospital management. The purpose of this study is to develop a dental information processing program, that will be used to store dental treatment records and digital image data using a new record media, the optical card. The patients' charts from the dental hospital were selected. The treatment records of the chart were put into the treatment data -recording area of the program, and the digital images of various dental x-ray films were made with a scanner. These data were stored in the optical card and analyzed to get the following results: 1. In this program it is possible to put treatment records and image data into and out from the optical card, and it is impossible to correct and delete all data recorded on the optical card. 2. All data in the optical card system can be searched and analyzed on database. 3. The resolution of image data stored in optical card is above 5.9 lp/mm. 4, All data of dental charts used as samples, stored to optical cards, occupies average 14%, In conclusion, with the development of the storage system using the optical card, a dental patient's life-time treatment record can be stored in one optical card and used as a substitute for the dental chart.

  • PDF

THE EFFECT OF CHLORHEXIDINE DIHYDROCHLORIDE AND SODIUM FLUORIDE ON STREPTOCOCCUS (Streptococcus에 대한 chlorhexidine dihydrochloride와 불화나트륨의 효과)

  • Kang, In-Sung;Choi, Nam-Ki;Kim, Seon-Mi;Oh, Jung-Suk;Yang, Kyu-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.31 no.2
    • /
    • pp.180-189
    • /
    • 2004
  • Chlorhexidine dihydrochloride and sodium fluoride have been used as agents inhibiting the replication of oral bacteria and the formation of dental plaque. There are various kinds of bacteria with different sensitivity against these agents. In this study, chlorhexidine dihydrochloride and sodium fluoride were studied about their effects on the replication of Streptococcus mutars, Streptococcus sobrinus, Streptococcus oralis and Streptococcus salivarius at their concentrations inhibiting the formation of artificial plaque by Streptococcus mutars. When Streptococcus mutans was cultured for 8 hours in the media added with $1.0{\mu}M$ chlorhexidine dihydrochloride, the weight of formed artificial plaque was decreased to $5.1{\pm}1.5mg$ compared with $106.1{\pm}18.1mg$ of the control(p<0.05). At the same time, the optical density of cultured media was decreased. The optical density of cultured media was slightly decreased in Streptococcus sobrinus, but was not decreased in Streptococcus oralis. The optical density of Streptococcus salivarius was decreased at 8 hours-incubation, was not decreased at 24 hours-incubation. When Streptococcus mutars was cultured for 8 hours in the media added with 3.0 mM sodium fluoride, the weight of formed artificial plaque was decreased to $26.7{\pm}8.3mg(p<0.05)$. At the same time, the optical density of cultured media was decreased. The optical density of cultured media was decreased in Streptococcus sobrinus and Streptococcus oralis, but was slightly decreased in Streptococcus salivarius. These results suggest that at the concentration of chlorhexidine dihydrochloride and sodium fluoridehe inhibiting the formation of artificial plaque by Streptococcus mutans, different species of genus Streptococcus show the different sensitivity against these agents.

  • PDF

An Experimental Study of The Effect of Injection-only and Injection/Compression on The Birefringence Structure in Transparent Disks (사출 및 사출/압축이 투명 디스크의 복굴절 분포에 미치는 영향에 관한 실험적 연구)

  • Min, I.K.;Lee, K.B.;Yoon, K.H.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2009.10a
    • /
    • pp.103-107
    • /
    • 2009
  • Recently, injection/compression molding process became more popular than ever to produce many transparent optical products of high precision. Especially, optical disk for read/write is the best example. But those optical disks can cause sensorial problems because of high birefringence or deformation from the residual stresses in the media. Therefore, it is necessary to study the effects of various process conditions on the final birefringence structure in injection-only and injection/compression molded disks for producing precision injection-molded products. In the present paper we have focused on the effect of injection, holding and compression processes on the optical anisotropy(i.e. birefringence) remaining in the MOD by examining the gapwise distribution of birefringence and extinction angle. The effect of holding pressure was found to form the inner two birefringence peaks. But the effect of compression pressure on the birefringence distribution was found to make the uniform distribution near the center in the gapwise direction and inversion of extinction angle far from the gate.

  • PDF

Shock Analysis of Optical Disk Drive Considering Rotational Effect (회전 효과를 고려한 광디스크 드라이브의 충격해석)

  • Lim, Seung-Ho;Park, No-Cheol;Park, Young-Pil;Hwang, Hyo-Kune;Seo,, Jeong-Kyo;Yoo, Seung-Hon;Choi, In-Ho;Min, Byung-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.622-625
    • /
    • 2008
  • SIL-based optical disk drive will be promising candidate of next-generation storage devices. However, a near-field optical disk drive requires the robustness to external shock because of extremely small gap between SIL and media. Especially, high-level shock damages permanently to SIL and it makes difficulties in general application. To study the likelihood of failure, the shock analysis must be performed over all others. This research explores the dynamic characteristics of rotating disk through FEM which is compared to analytical solution and experimental modal analysis. We also develop the finite element model of an optical disk drive, which includes rubber mounts, sled base, rotating disk and pickup assembly, and simulate the shock response.

  • PDF

Analysis for PSA Tolerance of TAMR Suspension (열 보조 자기기록용 서스펜션의 PSA 허용오차에 대한 분석)

  • Kim, Ki-Hoon;Lee, Yong-Hyun;Kim, Seok-Hwan;Lee, Sang-Jic;Park, No-Cheol;Park, Young-Pil;Park, Kyoung-Su
    • Transactions of the Society of Information Storage Systems
    • /
    • v.6 no.1
    • /
    • pp.12-17
    • /
    • 2010
  • Thermally-assisted magnetic recording (TAMR) is a potentially promising approach to increase the storage density of hard disk drive (HDD). However, TAMR has some issues such as temperature effects, media problems, thermal deformation and light delivery. In this research, we focused on light delivery. One of the powerful methods to deliver the light from laser diode to recording medium is the use of an optical fiber and a specially designed prism. However, the TAMR with optical fiber may have some flyability problems induced by the mounted optical fiber and prism. Also, the TAMR suspension using an optical fiber has high vertical and pitch stiffness. Therefore, p-torque is greatly increased by the optical fiber. Also, flying height (FH) of the slider with TAMR suspension can be largely changed by p-torque. Therefore, in this paper, we focus on the pitch static attitude (PSA) tolerance and the FH by PSA of the TAMR suspension. The FH is investigated using various errors and the PSA tolerance for TAMR suspension is proposed.

An Experimental Study of Injection Molding for Multi-beam Sensing Lens Using The Change of Gate Geometry (금형 게이트 크기 변화에 따른 멀티빔 센서용 렌즈 사출성형성 향상에 관한 연구)

  • Cho, S.W.;Kim, J.S.;Yoon, K.H.;Kim, J.D.
    • Transactions of Materials Processing
    • /
    • v.20 no.5
    • /
    • pp.333-338
    • /
    • 2011
  • Rapidly developing IT technologies in recent years have raised the demands for high-precision optical lenses used for sensors, digital cameras, cell phones and optical storage media. Many techniques are required to manufacturing high-precision optical lenses, including multi-beam sensing lenses investigated in the current study. In the case of injection molding for thick lenses, a shrinkage phenomenon often occurs during the process. This shrinkage is known to be the main reason for the lower optical quality of the lenses. In the present work, a CAE analysis was conducted simultaneously with experiments to understand and minimize this phenomenon. In particular, the sectional area of a gate was varied in order to understand the effects of packing and cooling processes on the final shrinkage pattern. As a result of this study, it was demonstrated that a dramatic reduction of the shrinkage could be obtained by increasing the width of the gate.

Optimal Conditions of Aerosol Flow Generation for High-density and Uniform Fog Screen (고밀도 균일 안개스크린을 위한 에어로졸 유동의 최적 생성조건)

  • Shin, Dongsoo;Song, Wooseok;Kim, Jinwon;Kim, Woojin;Koo, Jaye
    • Journal of ILASS-Korea
    • /
    • v.22 no.1
    • /
    • pp.13-21
    • /
    • 2017
  • The fog screen is a device projecting the media to the aerosol flow field. As major parameters to generate dense and steady fog screen, shear stress, optical blockage ratio and SMD were obtained result through experiment. The micro droplet was generated by the piezo oscillation element, and the aerosol flow mixed with an air flow was sprayed into the vertical direction from the top of the fog screen through the 280 mm slot. For produce a dense, uniform fog screen, the shear effect, optical blockage ratio and SMD between aerosol and air curtain were measured. The minimum and maximum shear stress conditions were selected and it was confirmed that the optical transmission deviation of the aerosol flow field was small when the aerosol and air curtain flow rates were changed. When the aerosol and air curtain flow power were 18 V (1.51 m/s) and 24 V (2.55 m/s), respectively, under the condition of the minimum shear stress and laminar flow, the optical blockage ratios with the spray length were small, and it produced a most stable and high density uniform fog screen by injecting a constant of $10{\mu}m$ or less.