• Title/Summary/Keyword: optical measuring system

Search Result 510, Processing Time 0.024 seconds

A Possible Application of the Nonuniform Electric Field Measurement Using Laser Interferometer and Pockels Effect (레이저 간섭계와 포켈스 효과를 이용한 불평등 전계 측정)

  • Gang, Won-Jong;Gu, Ja-Yun
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.51 no.6
    • /
    • pp.240-245
    • /
    • 2002
  • In this paper, a novel optical measuring system for the measurement of nonuniform electric field was proposed. The electric field distorted by the discharges was detected through proposed optical measuring system based on the Pockets effect and Mach-Zehnder interferometer. In order to produce distorted electric field, corona discharge was generated from needle-plane electrode in air and detected by optical measuring system. This optical measuring system is constructed by He-Ne laser, single mode optical fiber, $2{\times}2$ 50/50 beam splitter, $LiNbO_3$ Pockets cell, photo detector and PC. In this system, output signal of Pockels sensor is measured by digital oscilloscope and transferred to the PC for recording and statistical processing. Through this paper, a promising possibilities of proto-type optical measuring system were evinced.

Development of a Fizeau Interferometer System for Measuring the Profile of Large Optical Lens (대구경 렌즈의 형상 측정을 위한 Fizeau 간섭계 시스템 개발)

  • Bae, Kwang-Hwan;Lee, Eung-Suk;Lee, Ki-Am;Kim, Ok-Hyun
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.30 no.12 s.255
    • /
    • pp.1649-1657
    • /
    • 2006
  • Fizeau interferometer is well known optical instrument for measuring the lens profile accurately. The object of this study is focused on the design and optical measuring techniques for large optical components, such as a reflection mirror for astronomical purpose. Measuring of large optical lens, the object could not be moved as small one but the measuring instrument must be moved for the alignment, because of the geometric conditions and the accuracy of the stage. Therefore, a five axis stage is designed to align the Interferometer instead of the measuring object. This instrument will be used for an on machine measuring system in polishing machine for large optical lens.

Optical Gain Measuring System in the Laser Discharge using Feedback Light (귀환광을 이용한 레이저방전내의 광이득 측정시스템)

  • Choi, Sang-Tae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.9-14
    • /
    • 2011
  • A spectroscopic measuring system was developed in order to determine optical gain of gas laser discharge for any optical transitions between 190[nm] and 800[nm] without laser resonator. With an image optical system and a feedback optical system emission light of laser discharge are entered in a monochromator and received at a photomultiplier. Subsequently optical gain and line intensity are measured.

A Study on Non-contact Measurement of 3D-Objects by Optical Probe Method (광촉침법에 의한 비접촉 3차원 형상측정에 관한 연구)

  • Kang, Young-June;Shin, Seong-Kook;Miyoshi, Takashi
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.12 no.4
    • /
    • pp.119-126
    • /
    • 1995
  • This paper presents a non-contact measuring system using one point measuring method to measure surface profiles of dies and clay models for practical use in the field of production engineering. The system has a laser beam probe similar to a measuring probe in a contact measuring system and CCD linear sensor used to detect 300mm measurement range, displacement of measured surfaces, from an origin. There is no mechanical interference between this measuring system and a measured surface in this system. In this measuring system, it was needed 500-600ms including data processing time to measure one point. The experiments showed that the standard deviation was 800 .mu.m and the reproducibility was also 100-210 .mu. m.

  • PDF

Implementation of Optical-based Measuring Instrument for Contact Wire Geometry in Electric Railway (전기철도의 전차선로 형상검측을 위한 광학기반 검측 장치 구현)

  • Park, Young;Cho, Yong-Hyeon;Jung, Ho-Sung;Lee, Ki-Won;Kim, Hyung-Chul;Kwon, Sam-Young;Park, Hyun-June;Kim, Won-Ha
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.21 no.9
    • /
    • pp.868-871
    • /
    • 2008
  • We propose an optical-based measuring instrument of catenary system in electric railway. This system was made to utilize line scan camera as inspecting system to measure the stagger and height of overhead contact wire in railway and composed with optical type source and FPGA-based image acquisition system with PCI slot. Vision acquisition software has been used for the application to programming interface for image acquisition, display, and storage with a frequency of sampling. To check the validity of our approach for the intended application, we monitored height and stagger in the overhead wire of a high-speed catenary system in Korea. The proposed optical-based measuring instrument to measure the contact wire geometry such as the hight and stagger shows promising on-field applications for online condition motoring. We expect that a new generation of real-time instruments with demanding various conditions motoring requirement in railway can be easily integrated into optical-based measuring instrument system.

A Study on the Tower type Fizeau Interferometer System with a Fold Minor for Measuring Large Optical Lens Profile (반사경 측정을 위한 타워 방식의 Fold Mirror를 이용한 Fizeau 간섭계 시스템 구성)

  • Lee, Eung-Suk;Lee, Ki-Am;Kim, Ok-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.8
    • /
    • pp.21-28
    • /
    • 2008
  • Fizeau interferometer is used for inspecting the lens surface profile accurately. This study is focused on the design and optical measuring techniques for large optical components, such as a reflection mirror for large area lithography or astronomical purpose. A tower type Fizeau interferometer is designed and set up in horizontally with a 45$^{\circ}$ fold mirror which makes easy to align the optical path of heavy interferometer system. To align the optical path, a five-axes stage for the interferometer is required. This study shows a method of the 45$^{\circ}$ fold mirror alignment by using a three-axis stage instead of adjusting the interferometer itself or measuring object. This system will be installed on the large optics polishing machine during the manufacturing process as an on-machine inspection system.

Measurement of Focal Length for Off-axis Optical Systems

  • Choe, Se-woon;Ryu, Jaemyung
    • Current Optics and Photonics
    • /
    • v.5 no.4
    • /
    • pp.402-408
    • /
    • 2021
  • An off-axis system refers to an optical system in which the optical axis and normal vector at the vertex of each surface do not match. The most important specification in an optical system is its focal length. Among the various methods for measuring the focal length, the most suitable method for the off-axis system is the method that adopts magnification. However, head-mounted display (HMD) optics must be measured while considering the virtual image distance, which is not infinity owing to product characteristics. For the virtual image distance, a camera with a focusing function was used. By measuring HMD optics via this magnification method, the error generated in this measurement was 0.68% of the HMD's focal length, which is within the 1%-3% range of the conventionally permitted design error for the focal length allowed at the optical design stage. Therefore, it can be verified that the measurement accuracy of the method proposed in this study is sufficiently feasible in practice.

Development of 3-dimensional Pattern measuring technique for Micro-Optic components (미소광부품의 3차원 미세 패턴 측정 기술 개발)

  • 박희재;김종원;이준식;이정호
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2002.10a
    • /
    • pp.128-131
    • /
    • 2002
  • Three Dimensional measuring system using optical interference is greatly needed for semiconductor surface or optical surface. The application of this system are : MEMS product, semiconductor surfaces, optical components, precise machined surface, etc. In this paper, Interferometry based measurement system is introduced, which is nondestructive and noncontact inspection system. This system have relatively many advantage, compared with AFM/STM, SEM, Stylus, etc. The developed system can measure the surface topography with high precision and resolution, and with few seconds. And the associated software algorithm is also developed for the ultra precision 3D measuring surface. Various samples that is measured using this system is showed in the latter of this paper.

  • PDF

Development of 3D Measuring System using Spherical Coordinate Mechanism by Point Laser Sensor (포인트 레이저 센서를 이용한 구면좌표계식 3차원 형상측정시스템 개발)

  • 맹희영;성봉현
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2004.10a
    • /
    • pp.201-206
    • /
    • 2004
  • Laser scanner are getting used for inspection and reverse engineering in industry such as motors, electronic products, dies and molds. However, due to the lack of efficient scanning technique, the tasks become limited to the low accuracy purpose. The main reasons for this limitation for usefulness are caused from the optical drawback, such as irregular reflection, scanning direction normal to measuring surface, the influence of surface integrity, and other optical disturbances. To overcome these drawback of laser scanner, this study propose the mechanism to reduce the optical trouble by using the 2 kinds of rotational movement axis and by composing the spherical coordinate to scanning the surface keeping normal direction consistently. So, it could be designed and interfaced the measuring device to realize that mechanism, and then it could acquisite the accurate 3D form cloud data. Also, these data are compared with the standard master ball and the data acquisited from the touch point sensor, to evaluate the accuracy and stability of measurement and to demonstrate the implementation of an dental tooth purpose system

  • PDF

Calibration of Optical Dimensional Measurement System Using Optical Microscope (광학현미경을 이용한 비접촉식 치수측정시스템의 교정)

  • Park, Hyun-Goo;Park, Min-Cheol;Kim, Seung-Woo
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.11
    • /
    • pp.118-125
    • /
    • 1997
  • Non-contacting optical microscopes are increasingly used in recent industrial applications of probes for coordinate measuring machines. They have been found more efficient than conventional touch trigger porbes with ball tips especially in inspecting small-sized objects. There are two major factors affecting measuring accuracy: (1) geometric relations between coordinate systems, (2) magnification ratios of a microscope. In order to determine the magnification ratios exactly, optical imaging of edge was theroretically analyzed and practically adopted to image processing for edge detection. In addition, this paper proposes a geometric calibration method to obtain exact coordinates of measured points from the relations between the machine coordinate system and the image. In the method, the error according to the squareness between the machine axises was also removed. The method was practically adopted to a real coordinate measuring machine. An ultraprecision measurement of 0.2 um uncertainty can be practically achieved.

  • PDF