• Title/Summary/Keyword: optical manipulation

Search Result 52, Processing Time 0.026 seconds

A Proposal for Optical Diagnostics Through the Enhancement of Diffraction Patterns Using Thin-film Interference Filters

  • Stefanita Carmen Gabriela;Shao Yun Feng
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.9 no.6
    • /
    • pp.428-434
    • /
    • 2004
  • Coarse clumping of solid materials within diseased biological cells can have a marked influence on the light scattering pattern. Perturbations in refractive index lead to distinct varia­tions in the cytometric signature, especially apparent over wide scattering angles. The large dynamic range of scattering intensities restricts collection of data to narrow angular intervals be­lieved to have the highest potential for medical diagnosis. We propose the use of an interfer­ence filter to reduce the dynamic range. Selective attenuation of scattering intensity levels is expected to allow simultaneous data collection over a wide angular interval. The calculated angu­lar transmittance of a commercial shortwave-pass filter of cut-off wavelength 580 nm indicates significant attenuation of scattering peaks below ${\~}\;10^{circ}$, and reasonable peak equalization at higher angles. For the three-dimensional calculation of laser light scattered by cells we use a spectral method code that models cells as spatially varying dielectrics, stationary in time. How­ever, we perform preliminary experimental testing with the interference filter on polystyrene microspheres instead of biological cells. A microfluidic toolkit is used for the manipulation of the microspheres. The paper intends to illustrate the principle of a light scattering detection system incorporating an interference filter for selective attenuation of scattering peaks.

Electro-controllable omni-directional laser emissions from a helical polymeric network composite film

  • Jang, Won-Gun;Park, Byoung-Choo;Kim, Min-A;Kim, Sun-Woong;Kim, Yun-Ki;Choi, Eun-Ha;Seo, Yoon-Ho;Cho, Guang-Sup;Kang, Seung-Oun;Takezoe, Hideo
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2008.10a
    • /
    • pp.883-886
    • /
    • 2008
  • In optical information technology, an electro-controllable Photonic Band Gap (PBG) in a photonic crystal (PC) material is potentially useful for the manipulation of light. Despite a great deal of research on PBGs, the reliable use of electro-active PBG material systems is restricted to only a few cases because of the complex and limiting nature of the structures involved. Here, we propose a PBG system that uses a liquid crystal (LC) polymer composite. The composite is made of nematic LCs (NLCs) embedded in polymeric helical networks of photo-polymerized cholesteric LCs (CLCs). The composite film shows a large field-induced reversible color shift over 150 nm of the reflection band, due to the reorientational undulation of the helical axis, similar to the Helfrich effect.

  • PDF

Effects of Abdominal Respiration and Self Voice Feedback Therapy on the Voice Improvement of Patients with Vocal Nodules (복식호흡 훈련과 Self Voice Feedback 프로그램이 성대결절 환자의 음성개선에 미치는 효과)

  • Kwon, Soon-Bok;Wang, Soo-Geun;Yang, Byung-Gon;Jeon, Gye-Rok
    • Speech Sciences
    • /
    • v.13 no.3
    • /
    • pp.133-149
    • /
    • 2006
  • This study attempted to compare acoustic parameters, physiological observation and perceptual evaluation values obtained from the treatment and control groups in order to find out which of the self voice feedback therapies was better and which methods to train them were more effective. The experimental group carried out various self voice feedback therapies while the control group did only vocal hygiene. The acoustic measurement and voice manipulation for providing the patients visual, auditory feedback were done by a speech analysis software, Praat. The authors designed vocal hygiene, abdominal respiration and Praat self voice feedback therapies and applied them to 15 patients while applying only one vocal hygiene to 15 of the control group. For the purpose of examining the degree of their voice improvement after the treatment, pre- mid- and final evaluations were made for the two groups at the beginning, the 6th week and immediately after the 8th treatment session. Results of this study were as follows: The treatment group showed much improvement after receiving the voice treatment. In particular, acoustical and physiological indices from the optical endoscopy, pitch variation(Jitter), amplitude variation (Shimmer), maximum phonation time(MPT), and psychoacoustic evaluation showed statistically significant improvements over the control groups.

  • PDF

Distributed control system architecture for deep submergence rescue vehicles

  • Sun, Yushan;Ran, Xiangrui;Zhang, Guocheng;Wu, Fanyu;Du, Chengrong
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.274-284
    • /
    • 2019
  • The control architectures of Chuan Suo (CS) deep submergence rescue vehicle are introduced. The hardware and software architectures are also discussed. The hardware part adopts a distributed control system composed of surface and underwater nodes. A computer is used as a surface control machine. Underwater equipment is based on a multi-board-embedded industrial computer with PC104 BUS, which contains IO, A/D, D/A, eight-channel serial, and power boards. The hardware and software parts complete data transmission through optical fibers. The software part involves an IPC of embedded Vxworks real-time operating system, upon which the operation of I/O, A/D, and D/A boards and serial ports is based on; this setup improves the real-time manipulation. The information flow is controlled by the software part, and the thrust distribution is introduced. A submergence vehicle heeling control method based on ballast water tank regulation is introduced to meet the special heeling requirements of the submergence rescue vehicle during docking. Finally, the feasibility and reliability of the entire system are verified by a pool test.

A Study of Experimental Image Direction for Short Animation Movies -focusing in short film and (단편애니메이션의 실험적 영상연출 연구 -<탱고>와 <페스트 필름>을 중심으로)

  • Choi, Don-Ill
    • Cartoon and Animation Studies
    • /
    • s.36
    • /
    • pp.375-391
    • /
    • 2014
  • Animation movie is a non-photorealistic animated art that consists of formative language forming a frame based on a story and cuts describing frames that form the cuts. Therefore, in expressing an image, artistic expression methods and devices for a formative space are should be provided in a frame while cuts have the images between frames faithfully. Short animation movie is produced by various image experiments with unique image expressions rather than narration for expressing subjective discourse of a writer. Therefore, image style that forms unique images and various image directions are important factors. This study compared the experimental image directions of and , both of which showed a production method of film manipulation. First, while uses pixilation that produces images obtained from live images through painting and many optical disclosure process on a cell mat, was made with diverse collage techniques such as tearing, cutting, pasting, and folding hundreds of scenes from action movies. Second, expresses non-causal relationship of characters by their repetitive behaviors and circulatory image structure through a fixed camera angle, resisting typical scene transition. On the other hand, has an advancing structure that progresses antagonistic relationship of characters through diverse camera angles and scene transition of unique images. Third, in terms of editing, uses a long-take short cut technique in which the whole image consists of one short cut, though it seems to be many scenes with the appearance of various characters. On the other hand, maximizes visual fun and commitment by image reconstruction with hundreds of various short cuts. That is, both works have common features of an experimental work that shows expansion of animated image expressions through film manipulation that is different form general animation productions. On top of that, delivers routine life of diverse human beings without clear narration through image of conceptualized spaces. expresses it in a new image space through image reconstruction with collage technique and speedy progress, setting a binary opposition structure.

Micro-imaging techniques for evaluation of plastic microfluidic chip

  • Kim, Jung-Kyung;Hyunwoo Bang;Lee, Yongku;Chanil Chung;Yoo, Jung-Yul;Yang, Sang-Sik;Kim, Jin-Seung;Park, Sekwang;Chang, Jun-Keun
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.1 no.4
    • /
    • pp.239-247
    • /
    • 2001
  • The Fluorescence-Activated Cell Sorter (FACS) is a well-established instrument used for identifying, enumerating, classifying and sorting cells by their physical and optical characteristics. For a miniaturized FACS device, a disposable plastic microchip has been developed which has a hydrodynamic focusing chamber using soft lithography. As the characteristics of the spatially confined sample stream have an effect on sample throughput, detection efficiency, and the accuracy of cell sorting, systematic fluid dynamic studies are required. Flow visualization is conducted with a laser scanning confocal microscopy (LSCM), and three-dimensional flow structure of the focused sample stream is reconstructed from 2D slices acquired at $1\mutextrm{m}$ intervals in depth. It was observed that the flow structure in the focusing chamber is skewed by unsymmetrical velocity profile arising from trapezoidal cross section of the microchannel. For a quantitative analysis of a microscopic flow structure, Confocal Micro-PIV system has been developed to evaluate the accelerated flow field in the focusing chamber. This study proposes a method which defines the depth of the measurement volume using a detection pinhole. The trajectories of red blood cells (RBCs) and their interactions with surrounding flow field in the squeezed sample stream are evaluated to find optimal shape of the focusing chamber and fluid manipulation scheme for stable cell transporting, efficient detection, and sorting

  • PDF

The Usefulness of Electromagnetic Neuronavigation in the Pediatric Neuroendoscopic Surgery

  • Choi, Ki Young;Seo, Bo Ra;Kim, Jae Hyoo;Kim, Soo Han;Kim, Tae Sun;Lee, Jung Kil
    • Journal of Korean Neurosurgical Society
    • /
    • v.53 no.3
    • /
    • pp.161-166
    • /
    • 2013
  • Objective : Neuroendoscopy is applied to various intracranial pathologic conditions. But this technique needs informations for the anatomy, critically. Neuronavigation makes the operation more safe, exact and lesser invasive procedures. But classical neuronavigation systems with rigid pinning fixations were difficult to apply to pediatric populations because of their thin and immature skull. Electromagnetic neuronavigation has used in the very young patients because it does not need rigid pinning fixations. The usefulness of electromagnetic neuronavigation is described through our experiences of neuroendoscopy for pediatric groups and reviews for several literatures. Methods : Between January 2007 and July 2011, nine pediatric patients were managed with endoscopic surgery using electromagnetic neuronavigation (AxiEM, Medtronics, USA). The patients were 4.0 years of mean age (4 months-12 years) and consisted of 8 boys and 1 girl. Totally, 11 endoscopic procedures were performed. The cases involving surgical outcomes were reviewed. Results : The goal of surgery was achieved successfully at the time of surgery, as confirmed by postoperative imaging. In 2 patients, each patient underwent re-operations due to the aggravation of the previous lesion. And one had transient mild third nerve palsy due to intraoperative manipulation and the others had no surgery related complication. Conclusion : By using electromagnetic neuronavigation, neuroendoscopy was found to be a safe and effective technique. In conclusion, electromagnetic neuronavigation is a useful adjunct to neuroendoscopy in very young pediatric patients and an alternative to classical optical neuronavigation.

A Light Incident Angle Stimulated Memristor Based on Electrochemical Process on the Surface of Metal Oxide

  • Park, Jin-Ju;Yong, Gi-Jung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.174-174
    • /
    • 2014
  • Memristor devices are one of the most promising candidate approaches to next-generation memory technologies. Memristive switching phenomena usually rely on repeated electrical resistive switching between non-volatile resistance states in an active material under the application of an electrical stimulus, such as a voltage or current. Recent reports have explored the use of variety of external operating parameters, such as the modulation of an applied magnetic field, temperature, or illumination conditions to activate changes in the memristive switching behaviors. Among these possible choices of signal controlling factors of memristor, photon is particularly attractive because photonic signals are not only easier to reach directly over long distances than electrical signal, but they also efficiently manage the interactions between logic devices without any signal interference. Furthermore, due to the inherent wave characteristics of photons, the facile manipulation of the light ray enables incident light angle controlled memristive switching. So that, in the tautological sense, device orienting position with regard to a photon source determines the occurrence of memristive switching as well. To demonstrate this position controlled memory device functionality, we have fabricated a metal-semiconductor-metal memristive switching nanodevice using ZnO nanorods. Superhydrophobicity employed in this memristor gives rise to illumination direction selectivity as an extra controlling parameter which is important feature in emerging. When light irradiates from a point source in water to the surface treated device, refraction of light ray takes place at the water/air interface because of the optical density differences in two media (water/air). When incident light travels through a higher refractive index medium (water; n=1.33) to lower one (air; n=1), a total reflection occurs for incidence angles over the critical value. Thus, when we watch the submerged NW arrays at the view angles over the critical angle, a mirror-like surface is observed due to the presence of air pocket layer. From this processes, the reversible switching characteristics were verified by modulating the light incident angle between the resistor and memristor.

  • PDF

Development of a real-time Analysis System of Microchip Fluorescence Images based on Server-Client (서버 클라이언트 기반의 실시간 마이크로칩 형광 이미지 분석 시스템 개발)

  • Cho, Migyung;Shim, Jaesool
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.5
    • /
    • pp.1239-1244
    • /
    • 2013
  • In the field of clinical medicine and research, the analysis of such as protein and DNA at the molecular level and even at the cell level are necessary for disease diagnosis and treatment. In many cases, a real time image of samples is needed for the accurate analysis and manipulation of samples since experimental samples are degenerated with time. In this research, a three-dimensional fluorescence microscope device was developed for taking images of protein and DNA inside a single cell and the server-client based image analysis system was made for an integrated management of the real-time images taken from the microscope device. The system consists of a fluorescent measurement device, the associated software and a client program on smartphone. The developed system allows doctors or experimental managers to receive and look at the real-time experimental images taken from the samples of patients anywhere in the emergency, to analyze results and to instantly diagnose the disease and to transfer the results to the patients. As a result, the system is able to be utilized in the implementation of ubiquitous health as well.

Korean Red Ginseng aqueous extract improves markers of mucociliary clearance by stimulating chloride secretion

  • Cho, Do-Yeon;Skinner, Daniel;Zhang, Shaoyan;Lazrak, Ahmed;Lim, Dong Jin;Weeks, Christopher G.;Banks, Catherine G.;Han, Chang Kyun;Kim, Si-Kwan;Tearney, Guillermo J.;Matalon, Sadis;Rowe, Steven M.;Woodworth, Bradford A.
    • Journal of Ginseng Research
    • /
    • v.45 no.1
    • /
    • pp.66-74
    • /
    • 2021
  • Background: Abnormal chloride (Cl-) transport has a detrimental impact on mucociliary clearance in both cystic fibrosis (CF) and non-CF chronic rhinosinusitis. Ginseng is a medicinal plant noted to have anti-inflammatory and antimicrobial properties. The present study aims to assess the capability of red ginseng aqueous extract (RGAE) to promote transepithelial Cl- secretion in nasal epithelium. Methods: Primary murine nasal septal epithelial (MNSE) [wild-type (WT) and transgenic CFTR-/-], fisher-rat-thyroid (FRT) cells expressing human WT CFTR, and TMEM16A-expressing human embryonic kidney cultures were utilized for the present experiments. Ciliary beat frequency (CBF) and airway surface liquid (ASL) depth measurements were performed using micro-optical coherence tomography (μOCT). Mechanisms underlying transepithelial Cl- transport were determined using pharmacologic manipulation in Ussing chambers and whole-cell patch clamp analysis. Results: RGAE (at 30㎍/mL of ginsenosides) significantly increased Cl- transport [measured as change in short-circuit current (ΔISC = ㎂/㎠)] when compared with control in WT and CFTR-/- MNSE (WT vs control = 49.8±2.6 vs 0.1+/-0.2, CFTR-/- = 33.5±1.5 vs 0.2±0.3, p < 0.0001). In FRT cells, the CFTR-mediated ΔISC attributed to RGAE was small (6.8 ± 2.5 vs control, 0.03 ± 0.01, p < 0.05). In patch clamp, TMEM16A-mediated currents were markedly improved with co-administration of RGAE and uridine 5-triphosphate (8406.3 +/- 807.7 pA) over uridine 5-triphosphate (3524.1 +/- 292.4 pA) or RGAE alone (465.2 +/- 90.7 pA) (p < 0.0001). ASL and CBF were significantly greater with RGAE (6.2+/-0.3 ㎛ vs control, 3.9+/-0.09 ㎛; 10.4+/-0.3 Hz vs control, 7.3 ± 0.2 Hz; p < 0.0001) in MNSE. Conclusion: RGAE augments ASL depth and CBF by stimulating Cl- secretion through CaCC, which suggests therapeutic potential in both CF and non-CF chronic rhinosinusitis.