• Title/Summary/Keyword: optical filter

Search Result 1,009, Processing Time 0.029 seconds

A STUDY ON THE RELIABILITY OF THE OPTICAL CARIES ACTIVITY TEST (광학적 치아우식활성 검사법의 신뢰도에 관한 연구)

  • Park, Cheol-Hong;Lee, Nan-Young;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.33 no.4
    • /
    • pp.615-623
    • /
    • 2006
  • The purpose of this study was to evaluate the specificity, sensitivity, and diagnostic power of caries activity test using LED fluorescence. The subjects of this study were 55 children of $6{\sim}7$ years old. LED light were irradiated to labial or buccal surface of all teeth. Fluorescence from initial carious lesion of teeth illuminated by an LED light was observed through barrier filter and the number of teeth showing lesion, size and position of lesion were counted. Streptococcus mutans colony counting and dDfFtT rate test were also done and their correlation was compared. And then specificity, sensitivity, diagnostic power of optical caries activity test using LED light were evaluated. 1. There was positive $correlation({\gamma}=0.43)$ between LED fluorescence test and Streptococcus mutans count(P<0.05). 2. When visual examination was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 100%, 76.1%, and 100%. 3. When dDfFtT rate was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 88.9%, 47.8%, and 95.7%. 4. When S. mutans colony counting was defined to standard testing method, the specificity, sensitivity, diagnostic power of LED fluorescence test were 100%, 58.7%, and 100%. Considering the above results, optical caries activity test using LED light could be regarded as a practical method because of its close relationship with microbiological caries activity test.

  • PDF

A study on the design exploration of Optical Image Stabilization (OIS) for Smart phone (스마트폰을 위한 광학식 손떨림 보정 설계 탐색에 관한 연구)

  • Lee, Seung-Kwon;Kong, Jin-Hyeung
    • Journal of Digital Contents Society
    • /
    • v.19 no.8
    • /
    • pp.1603-1615
    • /
    • 2018
  • In order to achieve the low complexity and area, power in the design of Optical Image Stabilization (OIS) suitable for the smart phone, this paper presents the following design explorations, such as; optimization of gyroscope sampling rate, simple and accurate gyroscope filters, and reduced operating frequency of motion compensation, optimized bit width in ADC and DAC, evaluation of noise effects due to PWM driving. In experiments of gyroscope sampling frequencies, it is found that error values are unvaried in the frequency above 5KHz. The gyroscope filter is efficiently designed by combining the Fuzzy algorithm, to illustrate the reasonable compensation for the angle and phase errors. Further, in the PWM design, the power consumption of 2MHz driving is shown to decrease up to 50% with respect to the linear driving, and the imaging noises are reduced in the driving frequency above 2MHz driving frequency. The operating frequency could be reduced to 5KHz in controller and 10KHz in driver, respectively, in the motion compensation. For ADC and DAC, the optimized exploration experiments verify the minimum bit width of 11bits in ADC as well as 10bits in DAC without the performance degradation.

Image Encryption and Decryption System using Frequency Phase Encoding and Phase Wrapping Method (주파수 위상 부호화와 위상 랩핑 방법을 이용한 영상 암호화 및 복호화 시스템)

  • Seo, Dong-Hoan;Shin, Chang-Mok;Cho, Kyu-Bo
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.6
    • /
    • pp.507-513
    • /
    • 2006
  • In this paper, we propose an improved image encryption and fault-tolerance decryption method using phase wrapping and phase encoding in the frequency domain. To generate an encrypted image, an encrypting key which denotes the product of a phase-encoded virtual image, not an original image, and a random phase image is zero-padded and Fourier transformed and its real-valued data is phase-encoded. The decryption process is simply performed by performing the inverse Fourier transform for multiplication of the encrypted key with the decrypting key, made of the proposed phase wrapping method, in the output plane with a spatial filter. This process has the advantages of solving optical alignment and pixel-to-pixel mapping problems. The proposed method using the virtual image, which does not contain any information from the original image, prevents the possibility of counterfeiting from unauthorized people and also can be used as a current spatial light modulator technology by phase encoding of the real-valued data. Computer simulations show the validity of the encryption scheme and the robustness to noise of the encrypted key or the decryption key in the proposed technique.

High Purification of Hg2Br2 Powder for Acousto-Optic Tunable Filters Utilizing a PVT Process (PVT공정을 이용한 음향광학 가변 필터용 Hg2Br2 파우더의 고순도 정제)

  • Kim, Tae Hyeon;Lee, Hee Tae;Kwon, In Hoi;Kang, Young-Min;Woo, Shi-Gwan;Jang, Gun-Eik;Cho, Byungjin
    • Korean Journal of Materials Research
    • /
    • v.28 no.12
    • /
    • pp.732-737
    • /
    • 2018
  • We develop a purification process of $Hg_2Br_2$ raw powders using a physical vapor transport(PVT) process, which is essential for the fabrication of a high performance acousto-optic tunable filter(AOTF) module. Specifically, we characterize and compare three $Hg_2Br_2$ powders: $Hg_2Br_2$ raw powder, $Hg_2Br_2$ powder purified under pumping conditions, and $Hg_2Br_2$ powder purified under vacuum sealing. Before and after purification, we characterize the powder samples through X-ray diffraction and X-ray photoelectron spectroscopy. The corresponding results indicate that physical properties of the $Hg_2Br_2$ compound are not damaged even after the purification process. The impurities and concentration in the purified $Hg_2Br_2$ powder are evaluated by inductively coupled plasma-mass spectroscopy. Notably, compared to the sample purified under pumping conditions, the purification process under vacuum sealing results in a higher purity $Hg_2Br_2$ (99.999 %). In addition, when the second vacuum sealing purification process is performed, the remaining impurities are almost removed, giving rise to $Hg_2Br_2$ with ultra-high purity. This high purification process might be possible due to independent control of impurities and $Hg_2Br_2$ materials under the optimized vacuum sealing. Preparation of such a highly purified $Hg_2Br_2$ materials will pave a promising way toward a high-quality $Hg_2Br_2$ single crystal and then high performance AOTF modules.

Robust Maneuvering Target Tracking Applying the Concept of Multiple Model Filter and the Fusion of Multi-Sensor (다중센서 융합 및 다수모델 필터 개념을 적용한 강인한 기동물체 추적)

  • Hyun, Dae-Hwan;Yoon, Hee-Byung
    • Journal of Intelligence and Information Systems
    • /
    • v.15 no.1
    • /
    • pp.51-64
    • /
    • 2009
  • A location tracking sensor such as GPS, INS, Radar, and optical equipments is used in tracking Maneuvering Targets with a multi-sensor, and such systems are used to track, detect, and control UAV, guided missile, and spaceship. Until now, Most of the studies related to tracking Maneuvering Targets are on fusing multiple Radars, or adding a supplementary sensor to INS and GPS. However, A study is required to change the degree of application in fusions since the system property and error property are different from sensors. In this paper, we perform the error analysis of the sensor properties by adding a ground radar to GPS and INS for improving the tracking performance by multi-sensor fusion, and suggest the tracking algorithm that improves the precision and stability by changing the sensor probability of each sensor according to the error. For evaluation, we extract the altitude values in a simulation for the trajectory of UAV and apply the suggested algorithm to carry out the performance analysis. In this study, we change the weight of the evaluated values according to the degree of error between the navigation information of each sensor to improve the precision of navigation information, and made it possible to have a strong tracking which is not affected by external purposed environmental change and disturbance.

  • PDF

Development of OSL Dosimetry Reader (선량 판독용 OSL 측정장치의 개발)

  • Park, Chang-Young;Chung, Ki-Soo;Lee, Jong-Duk;Chang, In-Su;Lee, Jung-Il;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.1
    • /
    • pp.10-15
    • /
    • 2012
  • Design and performance test results of a newly developed optically stimulated luminescence (OSL) measurement system are presented in this paper. Generally, different types of optical filters are used in OSL reader system to minimize the interference of the stimulation light in the OSL signal. For optically stimulation of $Al_2O_3:C$, we have arrived at an optimal combination of the filters, i.e., GG420 filter for filtering the stimulating light source, and a combined UG11 and BG39 filter at the detecting window (PMT). By using a high luminance blue LED (Luxeon V), sufficient luminous intensity could be obtained for optically stimulation. By using various control boards, the OSL reader device was successfully interfaced with a personal computer. A software was developed to deliver required commands to operate the OSL reader by using the LabView program (National Instruments, Inc.). In order to evaluate the reliability and the reproducibility of newly designed-OSL reader. Performance testing of the OSL reader was carried out for OSL efficiency, OSL decay curve and signal to noise ratio of the standard $Al_2O_3:C$ OSL material. It was found to be comparable with that of commercial Riso reader system.

A Study on The Multi-point Signal and It's Directivity detection of FBG Hydrophone Using Hopper WDM be in The Making (Hopper WDM을 이용한 FBG(Fiber Bragg Grating) 하이드로폰(Hydrophone)의 다중점신호검출 및 지향성 연구)

  • Kim, Kyung Bok
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.156-163
    • /
    • 2015
  • In the using of FBG(Fiber Bragg Grating) developed in home land, we designed and manufactured united FBG acoustic transducers the first in Korea. they are being applied to multi-point signal detection of FBG Hydrophone used Hopper WDM(national patent NO 10-1502954) in the underwater. On united FBG transducers manufactured, we made an demonstrated on respective frequency response peculiarities in the underwater and analyzed the special characters. As the experimental result on frequency response peculiarities, we made it possible underwater acoustic detection on united FBG acoustic transducers type to maximum 30Hz~2.5KHz. it's the optimum conditions of 1.2KHz frequency in detection. And for the purpose of realization on multi-point signal detection on wide scope in the underwater, in the using of WDM(Wavelength Division Multiplexing) method and passive band-pass filter system, established arrays system and succeeded in multi-point underwater acoustic signal detection to the frequency 200Hz~1.3KHz out of the two united type FBG transducers. Additionally, it would be possible directivity detection for the object of its source as the intensity of detection signal varies with the sound source's direction and angle. From now on we prepared a new moment on the practical use study on FBG hydrophone in the future.

Hexagonal Boron Nitride Monolayer Growth without Aminoborane Nanoparticles by Chemical Vapor Deposition

  • Han, Jaehyu;Yeo, Jong-Souk
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.409-409
    • /
    • 2014
  • Recently hexagonal boron nitride (h-BN), III-V compound of boron and nitrogen with strong covalent $sp^2$ bond, is a 2 dimensional insulating material with a large direct band gap up to 6 eV. Its outstanding properties such as strong mechanical strength, high thermal conductivity, and chemical stability have been reported to be similar or superior to graphene. Because of these excellent properties, h-BN can potentially be used for variety of applications such as dielectric layer, deep UV optoelectronic device, and protective transparent substrate. Ultra flat and charge impurity-free surface of h-BN is also an ideal substrate to maintain electrical properties of 2 dimensional materials such as graphene. To synthesize a single or a few layered h-BN, chemical vapor deposition method (CVD) has been widely used by using an ammonia borane as a precursor. Ammonia borane decomposes into hydrogen (gas), monomeric aminoborane (solid), and borazine (gas) that is used for growing h-BN layer. However, very active monomeric aminoborane forms polymeric aminoborane nanoparticles that are white non-crystalline BN nanoparticles of 50~100 nm in diameter. The presence of these BN nanoparticles following the synthesis has been hampering the implementation of h-BN to various applications. Therefore, it is quite important to grow a clean and high quality h-BN layer free of BN particles without having to introduce complicated process steps. We have demonstrated a synthesis of a high quality h-BN monolayer free of BN nanoparticles in wafer-scale size of $7{\times}7cm^2$ by using CVD method incorporating a simple filter system. The measured results have shown that the filter can effectively remove BN nanoparticles by restricting them from reaching to Cu substrate. Layer thickness of about 0.48 nm measured by AFM, a Raman shift of $1,371{\sim}1,372cm^{-1}$ measured by micro Raman spectroscopy along with optical band gap of 6.06 eV estimated from UV-Vis Spectrophotometer confirm the formation of monolayer h-BN. Quantitative XPS analysis for the ratio of boron and nitrogen and CS-corrected HRTEM image of atomic resolution hexagonal lattices indicate a high quality stoichiometric h-BN. The method presented here provides a promising technique for the synthesis of high quality monolayer h-BN free of BN nanoparticles.

  • PDF

Sensitivity Enhancement of Polydiacetylene Vesicles through Control of Particle Size and Polymerization Temperature (입자크기와 중합온도 제어를 통한 폴리다이아세틸렌의 센싱감도 향상)

  • Lee, Gil Sun;Oh, Jae Ho;Ahn, Dong June
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.400-404
    • /
    • 2011
  • Many studies on polydiacetylene(PDA) have been investigated to apply to chemical and biological sensors due to their unique optical properties of color change from blue to red and fluorescence change from non-fluorescence to red fluorescence. Especially, high sensitivity against specific molecules is very important to apply polydiacetylenes to various sensors. In this study, we examined the effect of sensitivity enhancement of 10,12-pentacosadynoic acid(PCDA) vesicles in detection ${\alpha}$-cyclodextrin(CD) according to control of vesicle size by filters with different pore sizes and polymerization temperature. Colorimetric response(CR) was calculated using visible spectrometer. In order to investigate the effect of vesicle size on sensitivity of PDA vesicles, two PCDA vesicles were filtered without filtration and with 0.22 ${\mu}m$ filter. The two PCDA vesicles were polymerized at $25^{\circ}C$ and were incubated with ${\alpha}$-CD(5 mM) for 30 min. The CRs of the former and latter vesicles were 31.4% and 74.0%, respectively. Then, two PCDA vesicles filtered with 0.22 ${\mu}m$ filter were polymerized at $25^{\circ}C$ and $5^{\circ}C$ and were reacted with ${\alpha}$-CD(5 mM) for 30 min to examine the effect of polymerization temperature. The CRs of the former and latter vesicles were 74.0 and 99.2%, respectively. This suggests that vesicle sizes and polymerization temperature are key factors in enhancing the sensitivity of PDA vesicles. In addition, these results are expected to be useful to apply the PDA vesicles as biosensors to detect DNA, protein, and cells.

Study of a Brain Tumor and Blood Vessel Detection System Using Multiple Fluorescence Imaging by a Surgical Microscope (수술현미경에서의 다중형광영상을 이용한 뇌종양과 혈관영상 검출 시스템 연구)

  • Lee, Hyun Min;Kim, Hong Rae;Yoon, Woong Bae;Kim, Young Jae;Kim, Kwang Gi;Kim, Seok Ki;Yoo, Heon;Lee, Seung Hoon;Shin, Min Sun;Kwon, Ki Chul
    • Korean Journal of Optics and Photonics
    • /
    • v.26 no.1
    • /
    • pp.23-29
    • /
    • 2015
  • In this paper, we propose a microscope system for detecting both a tumor and blood vessels in brain tumor surgery as fluorescence images by using multiple light sources and a beam-splitter module. The proposed method displays fluorescent images of the tumor and blood vessels on the same display device and also provides accurate information about them to the operator. To acquire a fluorescence image, we utilized 5-ALA (5-aminolevulinic acid) for the tumor and ICG (Indocyanine green) for blood vessels, and we used a beam-splitter module combined with a microscope for simultaneous detection of both. The beam-splitter module showed the best performance at 600 nm for 5-ALA and above 800 nm for ICG. The beam-splitter is flexible to enable diverse objective setups and designed to mount a filter easily, so beam-splitter and filter can be changed as needed, and other fluorescent dyes besides 5-ALA and ICG are available. The fluorescent images of the tumor and the blood vessels can be displayed on the same monitor through the beam-splitter module with a CCD camera. For ICG, a CCD that can detect the near-infrared region is needed. This system provides the acquired fluorescent image to an operator in real time, matching it to the original image through a similarity transform.