• Title/Summary/Keyword: optical filter

Search Result 1,009, Processing Time 0.027 seconds

A Study on the Resolver Interface using a Rotor Position Detector Method with DFT (DFT에 의한 회전자 위치 검출 방법을 사용한 레졸버 인터페이스에 관한 연구)

  • Hwang, Lark-Hoon;Na, Seung-Kwon;Choi, Gi-Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.10
    • /
    • pp.4550-4560
    • /
    • 2011
  • Generally, a optical encoder is used to detect velocity for controling the electronic motor, the resolver is used when it is hard structurally to adjust encoder to electronic motor. so, the resolver has weakness in price in compare with encoder, but in case of controling the position of a magnetic polar, the resolver has stead detecting the absolute position of a rotator. This study is about the digital programing velocity detector which uses a minimum hardware : filter for detecting the revolve speed and rotor position of the motor by means of the resolver.

Spatial Frequency Filtering Characteristics of Annular Phase Gratings (고리형 위상 격자의 공간 주파수 필터 효과)

  • 김인길;고춘수;임성우;오용호;이재철
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.9
    • /
    • pp.994-1000
    • /
    • 2004
  • We studied the characteristics of annular phase gratings as spatial frequency filters. We first calculated the Fraunhofer diffraction patterns of annular gratings and then got the modulation transfer function (MTF) from the zeroth order Hankel transform of the intensity distribution function. Binaryphase annular grating shows higher diffraction efficiency than binary phase rectangular grating. But the MTF decreases linearly in the low-frequency region as that of rectangular grating does. The diffraction pattern of 4-phase annular grating is similar to that of 2-phase grating and hence MTFs of the two are much alike. For 8-phase annular grating, the 7th order diffracted beam is the lowest one next to the first. Consequently, the diffraction efficiency is very high and the MTF graph is curved upward. The diffracted beams except the first order are negligible and hence the MTF characteristics are more improved in the case of 16-phase grating. But the degree of improvement becomes lowered c(Impaled with 8-phase grating. We made a 16-phase annular grating and measured its MTF. The experimental result agrees well with the calculated one.

Depth Extraction of Convergent-Looking Stereo Images Based on the Human Visual System (인간시각체계에 기초한 교차시각 스테레오 영상의 깊이 추출)

  • 이적식
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.27 no.4A
    • /
    • pp.371-382
    • /
    • 2002
  • A camera model with optical axes parallel has been widely used for stereo vision applications. A pair of input ages are obtained from a convergent-looking stereo camera model based on the human visual system in this per, and each image is divided into quadrant regions with respect to the fixation point. The reasoning of quadrant partitions is based on the human visual system and is proven by a geometrical method. Image patches : constructed from the right and left stereo images. A modified cepstrum filter is applied to the patches and disparity vectors are determined by peak detection algorithm. The three-dimensional information for synthetic ages is obtained from the measured disparity and the convergent stereo camera model. It is shown that the experimental results of the proposed method for various stereo images are accurate around the fixation point like the human visual system.

Merging of KOMPSAT-1 EOC Image and MODIS Images to Survey Reclaimed Land (간척지 조사를 위한 KOMPSAT-1 EOC 영상과 MODIS 영상의 중합)

  • 신석효;김상철;안기원;임효숙;서두천
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2003.04a
    • /
    • pp.171-180
    • /
    • 2003
  • The merging of different scales or multi-sensor image data is becoming a widely used procedure of the complementary nature of various data sets. Ideally, the merging method should not distort the characteristics of the high-spatial and high-spectral resolution data used. To present an effective merging method for survey of reclaimed land, this paper compares the results of Intensity Hue Saturation (IHS), Principal Component Analysis (PCA), Color Normalized(CN) and High Pass Filter(HPF) methods used to merge the information contents of the high-resolution (6.6 m) Electro-Optical Camera (EOC) panchromatic image of the first Korea Multi-Purpose Satellite 1 (KOMPSAT-1) and the multi-spectral Moderate Resolution Imaging Spectroradiometer (MODIS) image data. The comparison is made by visual evaluation of three-color combination images of IHS, PCA, CN and HPF results based on spatial and spectral characteristics. The use of a contrasted EOC panchromatic image as a substitute for intensity in merged images with MODIS bands 1, 2 and 3 was found to be particularly effective in this study.

  • PDF

Ground Experiment of Spacecraft Attitude Control Using Hardware Testbed

  • Oh, Choong-Suk;Bang, Hyo-Choong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.1
    • /
    • pp.75-87
    • /
    • 2003
  • The primary objective of this study is to demonstrate ground-based experiment for the attitude control of spacecraft. A two-axis rotational simulator with a flexible ann is constructed with on-off air thrusters as actuators. The simulator is also equipped with payload pointing capability by simultaneous thruster and DC servo motor actuation. The azimuth angle is controlled by on-off thruster command while the payload elevation angle is controlled by a servo-motor. A thruster modulation technique PWM(Pulse Width Modulation) employing a time-optimal switching function plus integral error control is proposed. An optical camera is used for the purpose of pointing as well as on-board rate sensor calibration. Attitude control performance based upon the new closed-loop control law is demonstrated by ground experiment. The modified switching function turns out to be effective with improved pointing performance under external disturbance. The rate sensor calibration technique by Kalman Filter algorithm led to reduction of attitude error caused by the bias in the rate sensor output.

Long-Period Fiber Gratings Based on Periodically Surface-Etched Structure Imprinted by Using a Photoresist Polymer (폴리머 장주기 패턴을 이용한 표면 식각된 격자 구조 기반의 장주기 광섬유 격자)

  • Park, Sang-Oh;Kwon, Oh-Jang;Han, Young-Geun
    • Korean Journal of Optics and Photonics
    • /
    • v.22 no.1
    • /
    • pp.1-4
    • /
    • 2011
  • A new fabrication technique of long-period fiber gratings with periodically surface-etched structures is proposed. Transmission characteristics of the periodically surface-etched long-period fiber gratings are improved by changing strain because of variation of coupling strength between the core and the cladding modes. The sensitivities of the periodically surface-etched long-period fiber gratings to strain, torsion, and ambient refractive index were measured. The strain and the torsion sensitivities were measured to be $-0.033\;dB/\mu\varepsilon$ and -1.30 nm m/rad, respectively. The ambient index sensitivity was measured to be -31.33 nm/RIU from a range from 1.33 to 1.42.

Crystal growth and characteristics of lysozyme crystals

  • Kojima, Kenichi
    • Proceedings of the Korea Crystallographic Association Conference
    • /
    • 2002.11a
    • /
    • pp.3-3
    • /
    • 2002
  • Many studies on crystal growth mechanisms of the hen egg-white lysozyme protein crystals have mainly performed by optical microscopy and atomic force microscopy (AFM). As results, two types of growth mechanisms, which are a two-dimensional nucleation mechanism and a spiral growth mechanism, were identified. However, there was no direct evidence of grown-in screw dislocations at the spiral sites. We first observed the screw dislocations in tetragonal lysozyme crystals using synchrotron X-ray topography. In addition, to confirm the characteristics of dislocations, we have observed some elastic constants in lysozyme crystals in terms of the sound velocity measurement by pulse echo methods. Tetragonal hen egg-white lysozyme crystals were grown by the concentration gradient method. The crystals were grown in test tubes, with an inner diameter of 8 ㎜ and 80 ㎜ in length, held vertically. The test tubes were kept at 23C for 2 weeks. The maximum size of crystals were 3×3×4 ㎟. The high quality crystals were examined by Laue topography with a water filter using synchrotron radiation. Figure is a X-ray topograph. Several straight screw dislocations were observed. We also determined Burgers vector to be a [110] direction. The measurement of sound velocity was performed by the digital signal processing method. the crystals were placed in stainless steel vessel, which was filled with lysozyme solution used for crystal growth. We observed the longitudinal sound velocity along the [110] direction in the tetragonal is obtained to be 1817 ㎧. Therefore, Young modulus and shear modulus were evaluated to be 2.70 Gpa and 1.02 Gpa, respectively, if we assumed Poisson ratio is 0.33. These results will be discussed at the meeting.

  • PDF

Design of Hardware Interface for the Otto Struve 2.1m Telescope

  • Oh, Hee-Young;Park, Won-Kee;choi, Chang-Su;Kim, Eun-Bin;Nguyen, Huynh Anh Le;Lim, Ju-Hee;Jeong, Hyeon-Ju;Pak, Soo-Jong;Im, Myung-Shin
    • Bulletin of the Korean Space Science Society
    • /
    • 2009.10a
    • /
    • pp.25.3-25.3
    • /
    • 2009
  • To search for the quasars at z > 7 in early universe, we are developing a optical camera which has a $1k\times1k$ deep depletion CCD chip, with later planned upgrade to HAWAII-2RG infrared array. We are going to attach the camera to the cassegrain focus of Otto Struve 2.1m telescope at McDonald observatory of University of Texas at Austin, USA. We present the design of a hardware interface to attach the CCD camera to the telescope. It consists of focal reducer, filter wheel, and guiding camera. Focal reducer is needed to reduce the long f-ratio (f/13.7) down to about 4 for wide field of view. The guiding camera design is based on that of DIAFI offset guider which developed for the McDonald 2.7m telescope.

  • PDF

Algorithm for extracting region of interest in medical images using image processing techniques (영상처리 기법을 이용한 의료 영상에서 관심영역 추출 알고리즘)

  • Cho, Young-bok;Woo, Sung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.10a
    • /
    • pp.295-298
    • /
    • 2018
  • The proposed paper proposes an algorithm that automatically extracts the region of interest using image processing techniques for medical images. In general, the robust boundary segmentation technique provides robust and accurate segmentation results in object boundaries with various noise and direction generated during image acquisition through optimal segmentation of the edges considering noise characteristics and directionality in noise images. In this paper, it is possible to apply adaptive filter type and size to the structural information of the image object and apply it to the boundary division of various object objects. In addition, it is possible to divide the boundary between various noise images such as an ultrasound image and an optical image.

  • PDF

Source Analysis of Size Distribution and Density Estimation in PM2.5 -Part II (입경 분포 원인 분석 및 PM2.5 밀도 추정 -Part II)

  • Bae, Min-Suk;Park, Da-Jeong;Lee, Jeonghoon;Ahn, Joon-Young;Lee, Yeong-Jae
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.32 no.2
    • /
    • pp.158-166
    • /
    • 2016
  • To characterize the features of particle apparent density, continuous measurements of particle number size distributions from optical particle sizer (OPS) and 24 hr integrated particle mass concentrations from filter based sampler were conducted at the National institute of environmental research NamBu Supersite (NNBS, $35.22^{\circ}N$, $126.84^{\circ}E$) in Gwangju for 16 days from Nov. 4 in 2014. Source apportionment model was carried out by applying Positive Matrix Factorization (PMF) to particle size distribution data. Three different distributions related to primary and secondary sources were investigated by the diurnal patterns of identified factors. Density estimated by gaussian model has been calculated as $1.69g/cm^3$ with 95% confidence bounds ($1.57{\sim}1.81g/cm^3$).