• Title/Summary/Keyword: optical filter

Search Result 1,009, Processing Time 0.031 seconds

Focal Reducer for McDonald Otto Struve Telescope

  • Lim, Ju-Hee;Kim, Young-Ju;Park, Won-Kee;Kim, Jin-Young;Chang, Seung-Hyuk;Pak, Soo-Jong;Im, Myung-Shin
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.36.2-36.2
    • /
    • 2010
  • The CQUEAN (Camera for QUasars in EArly uNiverse) is an optical CCD camera optimized for observation of high redshift objects. It is going to be attached to the cassegrain focus of 2.1m telescope at McDonald Observatory, USA. We are making a focal reducer for CQUEAN to secure a larger field of view. The focal reducer is composed of four spherical lens, and it reduces the focal length of telescope by one third. We designed the lens configuration, performed tolerance analysis, and estimated the optical performance with ZEMAX. The differences in optical performace with/without filters were also investigated. The result from ZEMAX shows that the system has ample margin of errors for median seeing of 1.2" at McDonald observatory. Even with aberration and alignment tolerance, the performance is better than the original requirement. The lenses are now being made, and the lens barrel and an adapter for assembly of the Andor CCD camera and the filter wheel is now under designing process. We expect that the manufacturing of the focal reducer system as well as its optical test will be finished by April 2010.

  • PDF

Optimal Optical Filters of Fluorescence Excitation and Emission for Poultry Fecal Detection

  • Kim, Tae-Min;Lee, Hoon-Soo;Kim, Moon-S.;Lee, Wang-Hee;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.37 no.4
    • /
    • pp.265-270
    • /
    • 2012
  • Purpose: An analytic method to design excitation and emission filters of a multispectral fluorescence imaging system is proposed and was demonstrated in an application to poultry fecal inspection Methods: A mathematical model of a multispectral imaging system is proposed and its system parameters, such as excitation and emission filters, were optimally determined by linear discriminant analysis (LDA). An alternating scheme was proposed for numerical implementation. Fluorescence characteristics of organic materials and feces of poultry carcasses are analyzed by LDA to design the optimal excitation and emission filters for poultry fecal inspection. Results: The most appropriate excitation filter was UV-A (about 360 nm) and blue light source (about 460 nm) and band-pass filter was 660-670 nm. The classification accuracy and false positive are 98.4% and 2.5%, respectively. Conclusions: The proposed method is applicable to other agricultural products which are distinguishable by their spectral properties.

The Optimization of Indium Zinc Oxide Thin Film Process in Color Filter on Array structure

  • Lee, Je-Hun;Kim, Jin-Suek;Jeong, Chang-Oh;Kim, Shi-Yul;Lim, Soon-Kwon;Souk, Jun-Hyung
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2004.08a
    • /
    • pp.1244-1247
    • /
    • 2004
  • For obtaining the best panel quality of color filter on array(COA) architecture in TFF LCD, we investigated the influence of deposition temperature, $O_2$ flow, thickness on the optical transmittance, wet etching and adhesion properties of IZO deposited onto each color photo resist(red, green, blue). Average transmittance of the pixel single layer in the visible range(between 380 and 780nm) was mainly affected by thickness and showed maximum at 1250 ${\AA}$ while the thickness showing peak transparency in each R, G, B wavelength was different. The relation was calculated by using bi-layer transmission and reflectance model, which corresponded to experimental data very well. The adhesion of IZO deposited on each color PR was found to have enhanced value except red PR case, compared to that of IZO which was deposited on $SiN_x$. Wet etching pattern linearity was decreased as the thickness increased. The thickness of IZO was one of vital factors in order to optimize overall pixel process for fabricating COA structure.

  • PDF

Terrain Aided Inertial Navigation for Precise Planetary Landing (정밀 행성 착륙을 위한 지형 보조 관성 항법 연구)

  • Jeong, Bo-Young;Choi, Yoon-Hyuk;Jo, Su-Jang;Bang, Hyo-Choong
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.38 no.7
    • /
    • pp.673-683
    • /
    • 2010
  • This study investigates Terrain Aided Inertial Navigation(TAIN) which consists of Inertial Navigation System (INS) with the optical sensor for precise planetary landing. Image processing is conducted to extract the feature points between measured terrain data and on-board implemented terrain information. The navigation algorithm with Iterated Extended Kalman Filter(IEKF) can compensate for the navigation error, and provide precise navigation information compared to single INS. Simulation results are used to demonstrate the feasibility of integration to accomplish precise planetary landing. The proposed navigation approach can be implemented to the whole system coupled with guidance and control laws.

Vergence control of parallel stereoscopic camera using the binocular disparity information (시차정보를 이용한 수평이동방식 입체영상 카메라의 주시각제어)

  • Kwon, Ki-Chul;Kim, Nam
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.2
    • /
    • pp.123-129
    • /
    • 2004
  • This paper concerns auto vergence control of a parallel stereoscopic camera through geometrical analysis. In the construction of a parallel stereoscopic camera, we experimentally demonstrated linear relationship between the key object distance and the amount of vergence control. And we proposed a vergence control system for the stereoscopic camera using binocular disparity information. For the real-time calculation of disparity information, the Hybrid Cepstral filter algorithm, with input data acquired from the vertical projection data and from the down sampling data from the source images, was proposed for precision and high speed processing. With the disparity information algorithm and the vergence control of the parallel stereoscopic camera system, the stereoscopic images become more like those of the human eye.

Highly Sensitive Partial Discharge Sensor with Remote Monitoring Capabilities (원격감시 기능을 갖는 고감도 부분방전센서)

  • Choi, Kyoo-Nam
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.10 no.3
    • /
    • pp.349-356
    • /
    • 2015
  • Remote monitoring partial discharge sensor, equipping with hybrid filter combining optical and electrical noise reduction capabilities and with signal integrating function to calculate total arc energy, was investigated. Hybrid filter showed insensitivity to fluorescent and incandescent lamps under simulated distribution panel condition. Signal integrating function showed selective detection capability corresponding to different arc energy levels, while convention arc sensor had difficulty to discriminate arc energy level due to bursty arc waveform and peak level detection characteristics. The sensor showed possibility for application to remote monitoring partial discharge sensor, since it detected arc energy level corresponding to normal open and close discharge in low voltage 100A MCCB at 2m distance.

Adaptive Automatic Thresholding in Infrared Image Target Tracking (적외선 영상 표적추적 성능 개선을 위한 적응적인 자동문턱치 산출 기법 연구)

  • Kim, Tae-Han;Song, Taek-Lyul
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.17 no.6
    • /
    • pp.579-586
    • /
    • 2011
  • It is very critical for image processing of IIR (Imaging Infrared) seekers to achieve improved guidance performance for missile systems to determine appropriate thresholds in various environments. In this paper, we propose automatic threshold determination methods for proper thresholds to extract definite target signals in an EOCM (Electro-Optical Countermeasures) environment with low SNR (Signal-to-Noise Ratios). In particular, thresholds are found to be too low to extract target signals if one uses the Otsu method so that we suggest a Shifted Otsu method to solve this problem. Also we improve extracting target signal by changing Shifted Otsu thresholds according to the TBR (Target to Background Ratio). The suggested method is tested for real IIR images and the results are compared with the Otsu method. The HPDAF (Highest Probabilistic Data Association Filter) which selects the target originated measurements by taking into account of both signal intensity and statistical distance information is applied in this study.

Design and evaluation of light source for photodynamic diagnosis of cancer (광역학적 암진단을 위한 광원장치의 설계 및 평가)

  • Lim, Hyun-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2007.04a
    • /
    • pp.73-76
    • /
    • 2007
  • Photodynamic diagnosis(PDD) is a method to diagnose the possibility of cancer, both by the principle that if a photosensitizer is injected into an organic tissue, it is accumulated in the tissue of a malignant tumor selectively after a specific period, and by a comparison of the intensity of the fluorescence of normal tissue with abnormal tissue after investigating the excitation light of a tissue with accumulated photosensitizer. Since the selection of the wavelength band of excitation light has an interrelation with fluorescence generation according to the selection of a photosencitizer, it plays an important role in POD. This study aims at designing and evaluating light source devices that can stably generate light with various kinds of wavelengths In order to make possible PDD using a photosensitizer and diagnosis using auto-fluorescence. The light source device was a Xenon lamp and filter wheel, composed of an optical output control through Iris and filters with several wavelength bands It also makes the inducement of auto-fluorescence possible because it is designed to generate a wavelength band of 380-400. The transmission part of the light source was, developed to enhance the efficiency of light transmission. To evaluate this light source device, the characteristics of the light output and wavelength band were verified. To validate the capability of this device as PDD the detection of auto-fluorescence using mouse was performed.

  • PDF

Characteristics of particles at Kosan, Cheju Island: Intensive study results duting March 11 .sim. 17 1994 (제주도 고산지역 입자특성 : 1994년 3월 11일 - 17일 측정결과)

  • 김용표;심상규;문길주;백남준;김성주;허철구;강창희
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.11 no.3
    • /
    • pp.263-272
    • /
    • 1995
  • Characteristics of anbient at Korean, Cheju Island have been studied during the intensive field study period on March 11 .sim. 17, 1994 in collaboration with other research organizations from Korea and abroad. The particle size distribution was measured using an Electrical Aerosol Analyzer(EAA) and an Optical particle Counter(OPC). Fine particles(PM1 and PM3) have been collected by filter pack samplers and their ionic compositions have been analyzed. sampling errors inherent to the filter pack sampling method are discussed and the method to analyze those errors are presented. The rine mass concentrations of this study show very similar mass concentrations when Seoul is clear. This is somewhat surprising result, because the most of researchers believe that Kosan is one of the cleanest area in Korea. Bimodal volume size distributions with peak values around 0.1 .sim. 0.2.mu.m and 3.mu.m in particle dimeter were observed for most of the measurement period, particle mass loadings and ionic composition data show a large fraction of particles are from non-sea salt origins. Estimation of water content and acidity of particles based on measurement by a gas/particle equilibrium model, SCAPE, reveals that the pH values of particles are comparable to or lower than those estimated based on measurements in Los Angeles, U.S.A. during the SCAQS study. These findings with the meteorological conditions during the study period suggest that the particles collected during the period have originated from outside Cheju Island.

  • PDF

A Study of Weld Pool width Control in Gas Tungsten Arc Welding Using the Digital Image Processing (화상처리에 의한 Gas Tungsten Arc 용접에서의 용융지폭제어에 관한 연구)

  • Kim, Dong-Cheol;Rhee, Sehun;Um, Ki-Woan
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.20 no.9
    • /
    • pp.2760-2769
    • /
    • 1996
  • The feedback control systems of welding process using visual information can improve weld qualities. However, it is very difficult to get the visual information of weld pool since the light intensity of welding arc is much stronger than that of the weld pool. To explore the possibility of extending the capability of automatic welding machines, a study of a closed loop controlled welding system consisted of a GTA welding machine, a vision system, a stepping motor system and a digital computer was undertaken. Particularly, in this system, a CCD camera with a long wavelength pass filter was used to get a better weld pool image. Subsequently, an image analysis technique has been developed to measure the weld pool width. Using this weld pool width measurement, a colsed loop control system adjusted welding speed to maintain a constant weld pool width.