• Title/Summary/Keyword: optical center height

Search Result 53, Processing Time 0.026 seconds

Design and Fabrication of a Step Height Certified Reference Material for Multi-probe Inspection Instruments (다중 프로브 검사 계측 장비를 위한 단차 표준 인증 물질의 설계 및 제작)

  • Maeng, Sae-Rom;Jin, Jong-Han;Buajarern, Jariya;Kim, Jae-Wan;Kim, Jong-Ahn;Kang, Chu-Shik
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.3
    • /
    • pp.323-329
    • /
    • 2011
  • Certified reference materials (CRMs) have been used to calibrate surface profilers for reliable measurements. In this paper, we present a newly designed step height CRM which has a step height pattern with two different widths and various special patterns for checking radial magnification, distortion of optical viewing systems, etc. Especially, it could be useful for multi-probe inspection instruments in the manufacturing lines. The fabrication was done by conventional optical lithography and dry etching process with optimized conditions. To verify the step height values, a white-light scanning interferometer was used with objective lenses having magnification of $10{\times}$ and $100{\times}$. CRMs with nominal step heights of $0.5\;{\mu}m$, $1\;{\mu}m$, $3\;{\mu}m$, $5\;{\mu}m$, $7\;{\mu}m$, and $10\;{\mu}m$ were fabricated and the uniformity of these CRMs was evaluated to be less than 3 nm ($1{\sigma}$).

implementation and its limitations

  • Nahm, Kie-B.;Shin, Eun-S.;Ryoo, Seok-M.
    • Journal of the Optical Society of Korea
    • /
    • v.1 no.2
    • /
    • pp.90-93
    • /
    • 1997
  • The shallow depth of focus in conventional light microscopy hinders the observation of the whole image when the object is thicker than the depth of field. Most of the existing techniques measured the object distance, which is not necessarily the actual distance of each pixel in the image. We implemented a means of determining the "best focus" of each pixel and located the height of object points by sectioning at different sample heights. Combining the height information and its gray values together, we obtained an image where the blur from the finite depth of focus is eliminated. Limitations of the technique are discussed together with composed images.ed images.

A Study on Optical Characteristic of Plasmonic Nanostructure Depending on Height of Deposited Silver (플라즈모닉 구조를 위한 은 증착 두께에 따른 광 특성 해석 연구)

  • Kim, J.H.;Jeong, M.Y.
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.26 no.2
    • /
    • pp.55-58
    • /
    • 2019
  • Surface plasmon effect was considered importantly because of the enhancement of optical signals. It is important to detect weak optical signal in neuroscience and bio technology due to detect weaker image or signal. The height of silver can change the optical characteristic of plasmonic nano structure including transmittance and reflectance. In this paper, the optical characteristic of plasmonic nano structure were confirmed by the FDTD analysis method depending on the silver height and it was confirmed that energy was concentrated at the center of nano structure, and high far-field gain and current density in particular wavelength coule be obtained.

Lidar Measurement of Optical Properties of Cirrus Clouds at Kwangju, Korea

  • Noh, Y.M.;Choi, S.C.;Kim, Y.J.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.959-961
    • /
    • 2003
  • Cirrus clouds observation was conducted using a lidar system in order to measure their height, thickness and optical depth at Kwangju (35$^{\circ}$10'N, 126$^{\circ}$53'), Korea in winter, December 2002, and spring March and April 2003. Cirrus clouds at high altitude can be distinguished from atmospheric aerosols location by high depolarization ratio and high altitude. Cirrus clouds were observed at 5${\sim}$12km altitudes with a high depolarization ratio from 0.2 to 0.5. Optical depth of cirrus clouds had varied from 0.28 to 1.81. Radiative effect of observed cirrus cloud on climate system was estimated to be negative net flux from ?0.24 to ?31.04 W/m$^{2}$.

  • PDF

Eight-axis-polishing Machine for Large Off-axis Aspheric Optics

  • Rhee, Hyug-Gyo;Yang, Ho-Soon;Moon, Il-Kweon;Kihm, Hag-Yong;Lee, Jae-Hyub;Lee, Yun-Woo
    • Journal of the Optical Society of Korea
    • /
    • v.15 no.4
    • /
    • pp.394-397
    • /
    • 2011
  • For the purpose of fabricating off-axis aspheric optics, we propose an 8-axis-polishing machine combined with a testing tower whose height is up to 9 m. The proposed polishing machine was designed and analyzed by using a well-known finite element method. The eight axes of the machine have a synchronized motion generated by a computer, and each axis was calibrated by a heterodyne laser interferometer or an optical encoder. After calibration, the maximum positioning error of the machine was less than 2 ${\mu}m$ within a whole 2 m ${\times}$ 2 m area. A typical fabrication result of a ${\phi}1.5$ m concave mirror was also described in this manuscript.

Fabrication of Multi-layered Macroscopic Hydrogel Scaffold Composed of Multiple Components by Precise Control of UV Energy

  • Roh, Donghyeon;Choi, Woongsun;Kim, Junbeom;Yu, Hyun-Yong;Choi, Nakwon;Cho, Il-Joo
    • BioChip Journal
    • /
    • v.12 no.4
    • /
    • pp.280-286
    • /
    • 2018
  • Hydrogel scaffolds composed of multiple components are promising platform in tissue engineering as a transplantation materials or artificial organs. Here, we present a new fabrication method for implementing multi-layered macroscopic hydrogel scaffold composed of multiple components by controlling height of hydrogel layer through precise control of ultraviolet (UV) energy density. Through the repetition of the photolithography process with energy control, we can form several layers of hydrogel with different height. We characterized UV energy-dependent profiles with single-layered PEGDA posts photocrosslinked by the modular methodology and examined the optical effect on the fabrication of multi-layered, macroscopic hydrogel structure. Finally, we successfully demonstrated the potential applicability of our approach by fabricating various macroscopic hydrogel constructs composed of multiple hydrogel layers.

The Effect of the Optical Points Difference between Finished-Reading Glasses and Dispensing Reading Glasses (완성품 돋보기와 조제가공된 돋보기가 광학적 요소에 미치는 영향)

  • Shim, Young-Cheol;Yoo, Gun-Chang;Kim, In-Suk
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.13 no.3
    • /
    • pp.65-71
    • /
    • 2008
  • Purpose: This paper studied the effect of eyes on the comparison between the distance optical centers problem of dispensing reading glasses made by optician and finished reading glasses in the current market. Methods: The method of this study has been measured by eleven different categories from +1.00D to +4.00D. This study also separated into three groups by their optical frame size and measured optical center point (O.C) and optical center height (O.H) with 200 peoples of man and females over 40 years old without ocular disease living in Gwang-san gu, Gwang-Ju city. Results: As a result, optical center point ranged from 57 mm to 80 mm and it turned to be most common range is from 61 mm to 65 mm (64.6%). Moreover, the optical center height ranged from 1 mm to 8mm and most common ranged (23%) were 4 mm. In other words, finished reading glasses have irregular optical ranges. After observing 200 people who are over 40 years old men and women, result shows that more than 75.5% (151 people) currently use finished reading glasses. Survey of 151 people, most common error between the finished reading glasses's O.C and the wearers P.D were 4 mm (45%). Furthermore, the most common error between the finished reading glassses's O.H and the wearers O.H ranged from 3 mm to 4 mm. Astonishingly, the entire 151 people who wear finished reading glasses appeal that they feel tiredness on their eyes when they wear finished reading glasses. 53 people (35%) claimed that they feel tiredness on their eyes after 10 to 20 minutes wearing finished reading glasses. Base on the research, We conducted more experiment to find the value of prism of optical centers err because it will tell us whether the finished reading glasses are good enough to wear or not. We multiplied diopter by the difference between finished reading glasses's O.C. and wearer's P.D. Consequently, We found out that the finished reading glasses counter to the German RAL-RG 915 policy. And We also found that it is relative to the diopter of lenses. In conclusion, based on the researched that wearing finished reading glasses have a dangerous factor for our vision. Therefore optician must need to recommend correctly made dispensing reading glasses based on the optical center point.

  • PDF

Analysis of Environmental Factors Affecting the Machining Accuracy (가공정밀도에 영향을 미치는 환경요소 분석)

  • Kim, Young Bok;Lee, Wee Sam;Park, June;Hwang, Yeon;Lee, June Key
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.20 no.7
    • /
    • pp.15-24
    • /
    • 2021
  • In this paper, to analyze the types of surface morphology error according to factors that cause machining error, the experiments were conducted in the ultra-precision diamond machine using a diamond tool. The factors causing machining error were classified into the pressure variation of compressed air, external shock, tool errors, machining conditions (rotational speed and feed rate), tool wear, and vibration. The pressure variation of compressed air causes a form accuracy error with waviness. An external shock causes a ring-shaped surface defect. The installed diamond tool for machining often has height error, feed-direction position error, and radius size error. The types of form accuracy error according to the tool's errors were analyzed by CAD simulation. The surface roughness is dependent on the tool radius, rotational speed, and feed rate. It was confirmed that the surface roughness was significantly affected by tool wear and vibration, and the surface roughness of Rz 0.0105 ㎛ was achieved.

Adjustment System by Optical Measurements of Assembly Tolerancies of VCR HEAD (조립오차의 광학식 측정에 의한 VCR HEAD 조정 SYSTEM)

  • Yun, Byung-Han;Yun, Jong-Soon
    • Proceedings of the KIEE Conference
    • /
    • 1995.07b
    • /
    • pp.849-851
    • /
    • 1995
  • Magnetic heads on vcr drum are adjusted for protrusion, rotational angle, setting angle between two symmetrically positioned heads and height difference. Developed adjustment system covered assembly spec., namely ${\pm}2{\mu}m$ and ${\pm}30{\mu}m$ in rotational angle by using the image processing to determine head positions and S/W algorithm to compensate mechanical errors.

  • PDF

Development of Automatic Alignment Height and Cross-section Inspection System for Fiber Bragg Grating Embedded Field Assembly Connector (FBG Embedded 현장 조립형 커넥터의 자동 정렬 및 단면 자동 검사 시스템 개발)

  • Lee, Jung-Ho;Park, Chan-Hee;Yoon, Jae-Soon;Lee, Hee-Kwan;Kim, Cheol-Sang;Kim, Jae-Won;Kim, Kyung;Kim, Jae-Jun
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.23 no.1
    • /
    • pp.94-101
    • /
    • 2014
  • Recently, in order to reduce the time required to replace an optical jumper cord, many researchers are using a field-installable connector and applying the ferrule polishing method, ferrule mechanical contact method, or ferrule fusion contact method. However, the process of arranging the length of the optical fiber, i.e., inserting the optical fiber into the ferrule by hand and checking its cross section, takes 60% of the time required for the entire process, which increases the overall cost. Therefore, in order to make this task more cost-effective, we will develop an automated inspection system with automatic cross-sectional arrangement of a field-installable connector. This system will be able to decrease the failure rate from 10% to 2% compared with the conventional method when cutting the optical fiber inserted into the ferrule. It will also improve the productivity by decreasing the test time by 28% compared with the conventional method. Our studies showed that it was possible to reduce the production costs and improve the quality of a field-installable connector, and we expect it to dominate the market.