• Title/Summary/Keyword: opposite 필터

Search Result 26, Processing Time 0.035 seconds

A Variable-Q Digital Graphic Equalizer with Opposite Filters (Opposite 필터를 적용한 가변 Q 디지털 그래픽 이퀄라이저)

  • 이용희;김인철;조국춘
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.41 no.4
    • /
    • pp.131-139
    • /
    • 2004
  • This paper proposes a variable-Q digital graphic equalizer with the opposite filters. A method for designing the proposed equalizer is also presented. In the proposed variable-Q equalizer, we adjust the Q-factor of the equalizer filter depending on the gain, yielding an improved equalizer performance. Also, by increasing the Q-factor of the opposite filters gracefully as the gain becomes greater, the inter-band interference can be removed effectively. We shall show that the frequency response of the proposed equalizer can reproduce the user's gain setting faithfully.

Cultural Characteristics and Fruiting-body Productivity of New Variety 'Hwadam' (Lentinula edodes) According to Filter Treatment in Boxes (상자에 필터처리에 따른 표고 신품종 '화담'의 재배특성 및 자실체 생산성)

  • Kim, Jeong-Han;Kang, Young-Ju;Baek, Il-Sun;Shin, Bok-Eum;Ha, Tai-Moon;Jung, Gu-Hyun
    • The Korean Journal of Mycology
    • /
    • v.48 no.2
    • /
    • pp.95-102
    • /
    • 2020
  • This study was carried out to develop a new method of cultivation of 'Hwadam' a new variety of Lentinula edodes, to improve fruiting body productivity and reduce labor. To determine the optimum filter number for box cultivation, L. edodes were assessed for their cultural characteristics and mushroom yield. During spawn running of L. edodes in the box, the temperature gradually increased to the highest value of 25.8℃, 23.7℃, and 23.0℃ on day 18 for the four filter, two filter, and no treatment groups, respectively. Oxygen concentration displayed an opposite trend to carbon dioxide concentration, reaching the lowest value on day 21. The oxygen concentration progressively increased as more filters were used (5.4%, 8.2%, and 8.9% treatment with no, two, and four filters, respectively. Growth of L, edodes in the box resulted in the highest yield (2,228 g/7kg substrate) and biological efficiency (70.7%) using four filters. The biological efficiency of the four filter treatment was 29.4% higher compared to bag cultivation (41.3%). Further studies are necessary to verify stable productivity of fruiting bodies through repeated cultivation.

Spectral Resolution Enhancement of Acousto-Optic Tunable Filter(AOTF) using Incident Angle Variation (음향광학변조필터의 입사각 변화를 이용한 분해능 향상 방법)

  • You, Jang-Woo;Ahn, Jeong-Ho;Kim, Dae-suk;Kwak, Yoon-Keun;Kim, Soo-Hyun;Lee, Yun-Woo;Whang, In-Duk
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.607-612
    • /
    • 2004
  • Spectral resolution enhancement method of Acousto-Optic Tunable Filter (AOTF) using incident light angle variation is described. AOTF is a small, mechanically rigid, high speed and spectral resolution light tunable filter. The basic theory of AOTF and its experimental verification is described. AOTF can generate two opposite polarized light simultaneously which wavelength can be changed by incident angle variation. We focused on the common region of two filtered light at the specific incident angle. This region can be used to enhance the spectral resolution of AOTF.

  • PDF

Dose Evaluation Using Mathematical Simulation of Radiation Exposure Body in Mammography System (유방영상시스템에서 수학적 모의피폭체를 이용한 선량평가)

  • Lee, Jinsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.155-161
    • /
    • 2014
  • Mammography is mostly performed by series projection on both breasts. While taking mammography, it is less than average glandular dose of 3 mGy which regulated. But mammography is exposed much more doses actually, due to additional or series projection. Also, it is difficult to recognize around organ dose except exposed breast. Using mathematical simulation of radiation exposure body in mammography, we studied around organ dose distribution by changing thickness(25, 30, $50{\mu}m$) of filter and relative absorption dose rate which set on basis of exposed breast. as a result, when setting of basis of exposed breast, dose of opposite breast is more affected approximately from 79.26 to 86.31%. when using $25{\mu}m$ of filter thickness than $30{\mu}m$, $50{\mu}m$ of filter thickness in Mo/Mo, W/Rh combination which used actually, absorbed dose rates for opposite breast and around organ were low.

A Loop Filter Size and Spur Reduced PLL with Two-Input Voltage Controlled Oscillator (두 개의 입력을 가진 VCO를 이용하여 루프필터와 스퍼 크기를 줄인 위상고정루프)

  • Choi, Young-Shig;Moon, Dae-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.8
    • /
    • pp.1068-1075
    • /
    • 2018
  • In this paper, a novel PLL has been proposed that reduces the size of the loop filter while suppressing spur by using a VCO with two inputs. Through the stability analysis according to the operating status, the PLL is designed to operate stably after the phase fixing. The capacitor of loop filter usually occupies larger area of PLL. It is a VCO that can reduce the size of the loop filter by increasing the effective capacitance of the capacitor through the simultaneous charge and discharge operation by two charge pumps and has two signals operating in opposite phases. The settling time of set to $80{\mu}s$ approximately by using a LSI(Locking Status Indicator) indicating the phase locking status. The proposed PLL is designed using a supply voltage of 1.8V and a $0.18{\mu}m$ CMOS process.

Application of Wiener filter to Chest CR images (흉부 CR영상에 대한 위너필터의 적용)

  • Choi, Seokyoon
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.4
    • /
    • pp.519-524
    • /
    • 2018
  • Chest examinations and mass chest examinations using the CR(computed radiography) System are frequently used clinically. a factor that degrades image quality in the acquisition process is the use of unused IPs long times. this paper addresses the estimation of winer filter and improved wiener filter to restoration of Chest CR images Experimental results show that the proposed method can reduce noise. in low noise variation image wiener method was excellent than improved method and the result was the opposite at high noise varience. the application of algorithms to chest CR images effectively eliminates noise. the classic Wiener filter was better than the improved method. Multiple patients examined during the process without any erase IP(image plate) process, The proposed algorithm determines that the images can be restored to a good quality and will help to read the images.

A temperature stable bandpass filter using dieletric-filled stepped impedance resonators (접합된 Stepped impedance resonator를 이용한 온도보상형 유전체 대역통과 필터)

  • Lim, Sang-Kyu;Kim, Jun-Chul;Kim, Duck-Hwan;Ha, Jong-Su;Oh, Chang-Heon;Sim, Hwa-Sup;An, Chul
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.2
    • /
    • pp.78-85
    • /
    • 1998
  • The design method of a temperature stable bandpass filter using dielectric coaxial resonators of with two dielectric ceramics with opposite signs of temperature coefficient of dielectric constant (${\tau}_{\epsilon}$) to compensate for each other in this method. $MgTiO_3$(${\tau}_{\epsilon}$=+99 ppm/${\circ}C$) as a positive ${\tau}_{\epsilon}$ material and Ba($Zn_{1/3}Nb_{2/3}$)$O_3$(${\tau}_{\epsilon}$=-77ppm/${\circ}C$) as a negative material were selected. The length of a SIR for the temperature stability was calculated according to the design method and the susceptance slope parameter of the SIR was obtained. A temperature stable bandpass filter using dielectric SIR's was designed, simulated and fabricated. The center frequency of this filter was 915 MHz and the pass bandwidth was 20 MHz. Temperature properties of this bandpass filter by simulations were compared with the measured results of the bandpass filter fabricated.

  • PDF

Phase Tracking Settling Time and BER Performance Evaluation in the Digital Retrodirective Array Antenna System (디지털 역지향성 배열 안테나 시스템에서 위상 추적 Settling 시간과 BER 성능 평가)

  • Kim, So-Ra;Lee, Seung Hwan;Shin, Dong Jin;Ryu, Heung-Gyoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.55-63
    • /
    • 2013
  • Digital retrodirective antenna system is easy to modify and upgrade because it can control the phase information of the output signal toward opposite direction to input signal without a priori knowledge of the arrival direction. Due to this advantage, it is possible to do fast beam tracking. Especially, we need to design the digital PLL performance for the digital retrodirective array antenna system. So, in this paper the settling time of phase estimator and BER performance of retrodirective antenna system are investigated according to design of filter in digital PLL. When QAM signal is used for 1 Mbps with $30^{\circ}$ of phase delay, simulation results show that digital phase conjugation technique has better BER performance by about 1 dB than non-phase conjugation system when digital filter is stable. If not, the system can't estimate the exact phase because of oscillation of filter.

Pore Structure Modification and Characterization of Porous Alumina Filter with Chemical Vapor Infiltration (CVI) SiC Whisker (화학증착 탄화규소 휘스커에 의한 다공성 알루미나 필터의 기공구조 개질 및 특성 평가)

  • 박원순;최두진;김해두
    • Journal of the Korean Ceramic Society
    • /
    • v.41 no.7
    • /
    • pp.518-527
    • /
    • 2004
  • In this study, SiC whiskers were grown in porous alumina substrate in order to enhance the filtering efficiency, performance, and durability by controlling pore morphology. This experiment was performed by Chemical Vapor Infiltration (CVI) in order to obtain the whiskers on the inside of pores as well as on the surface of porous the A1$_2$O$_3$ substrate. The deposition behavior was changed remarkably with the deposition position, temperature, and input gas ratio. First, the mean diameter of whisker was decreased as the position of observation moved into the inside of substrate due to the reactant gas depletion effect'. Second, the deposition temperature caused the changes of the deposition type such as debris, whiskers and films and the change in morphology affect the various properties. When SiC films were deposited. the gas permeability and the specific surface area decreased. However, the whisker showed the opposite result. The whiskers increase not only the specific surface area and minimizing pressure drop but also mechanical strength. Therefore it is expected that the porous alumina body which deposited the SiC whisker is the promising material for the filter trapping the particles.