• Title/Summary/Keyword: operational techniques

Search Result 369, Processing Time 0.024 seconds

시뮬레이션 기법을 이용한 컨테이너터미널 운영규칙의 평가 (Evaluation of Operational Rules for Container Terminals Using Simulation Techniques)

  • 장성용;임진만
    • 한국시뮬레이션학회:학술대회논문집
    • /
    • 한국시뮬레이션학회 2002년도 춘계학술대회논문집
    • /
    • pp.33-41
    • /
    • 2002
  • This paper deals with the development of simulation model for the container terminal consisting of 3 berths, 8 container cranes, 16 yard blocks with each yard cranes and 90 yard trucks in order to evaluate the various operational rules. The proposed operational rules are 3 ship dispatching rules, 3 berth allocation rules, 2 crane allocation rules, 2 yard allocation rules and 2 yard truck allocation rules and 4 performance measures like ship time in the terminal, ship time in the port, the number of ships processed and the number of containers handled are considered. The simulation result are as follows. 1) no difference among 3 ship dispatching rules, 2) berth allocation rules depends on performance measures 3) dynamic crane allocation is better than fixed policy 4) pooling yard allocation is better than short distance yard allocation rules and 5) fixed yard truck allocation by berth is a little better than pooling policy.

  • PDF

시뮬레이션 기법을 이용한 컨테이너터미널 운영규칙의 평가 (Evaluation of Operational Rules for Container Terminals Using Simulation Techniques)

  • 장성용;이원영
    • 한국항만경제학회지
    • /
    • 제18권1호
    • /
    • pp.27-41
    • /
    • 2002
  • This paper deals with the development of a simulation model for the container terminal, which consists of 3 berths, 8 container cranes, and 16 yard blocks with each yard crane and 90 yard trucks in order to evaluate the various operational rules. The proposed operational rules are 3 ship-dispatching rules, 3 berth allocation rules, 2 crane allocation rules, 2 yard allocation rules, and 2 yard truck allocation rules. These rules are simulated using 4 performance measures, such as ship time in the terminal, ship time in the port, the number of ships processed, and the number of containers handled. The simulation result is as follows: 1) there is no difference among 3 ship-dispatching rules, 2) berth allocation rules depend on performance measures, 3) dynamic crane allocation is better than fixed policy, 4) pooling yard allocation is better than short distance yard allocation rules, and 5) fixed yard truck allocation by berth is a little better than pooling policy.

  • PDF

사이버공격 추적시스템 운용아키텍처 (Cyberattack Tracing System Operational Architecture)

  • 안재홍
    • 한국군사과학기술학회지
    • /
    • 제26권2호
    • /
    • pp.179-187
    • /
    • 2023
  • APT cyber attacks have been a problem for over a past decade, but still remain a challenge today as attackers use more sophisticated techniques and the number of objects to be protected increases. 'Cyberattack Tracing System' allows analysts to find undetected attack codes that penetrated and hid in enterprises, and to investigate their lateral movement propagation activities. The enterprise is characterized by multiple networks and mass hosts (PCs/servers). This paper presents a data processing procedure that collects event data, generates a temporally and spatially extended provenance graph and cyberattack tracing paths. In each data process procedure phases, system design considerations are suggested. With reflecting the data processing procedure and the characteristics of enterprise environment, an operational architecture for CyberAttack Tracing System is presented. The operational architecture will be lead to the detailed design of the system.

HSR Traffic Reduction Algorithms for Real-time Mission-critical Military Applications

  • Nguyen, Xuan Tien;Rhee, Jong Myung
    • 정보와 통신
    • /
    • 제32권10호
    • /
    • pp.31-40
    • /
    • 2015
  • This paper investigates several existing techniques to reduce high-availability seamless redundancy (HSR) traffic. HSR is a redundancy protocol for Ethernet networks that provides duplicated frames for separate physical paths with zero recovery time. This feature makes it very useful for real-time and mission-critical applications, such as military applications and substation automation systems. However, the major drawback of HSR is that it generates too much unnecessary redundant traffic in HSR networks. This drawback degrades network performance and may cause congestion and delay. Several HSR traffic reduction techniques have been proposed to reduce the redundant traffic in HSR networks, resulting in the improvement of network performance. In this paper, we provide an overview of these HSR traffic reduction techniques in the literature. The operational principles, advantages, and disadvantages of these techniques are investigated and summarized. We also provide a traffic performance comparison of these HSR traffic reduction techniques.

해저 파이프라인 가설 분석 기술 (Advanced Offshore Pipelaying Analysis techniques Part 2 : Laybarge Methods)

  • 최한석
    • 한국해양공학회지
    • /
    • 제9권2호
    • /
    • pp.7-19
    • /
    • 1995
  • Various laybarge methods for offshore pipeline installation are introduced. Pipe stresses and strains during the installation are discussed with linear and nonlinear analysis methods. Several operational modes of offshore pipeline installation are described. Computer modelling techniques of the pipeline installation analyses are suggested.

  • PDF

일관제조공정에서의 최적 조업조건의 도출 (Determination of an optimal operation condition in continuous manufacturing process)

  • 김윤호;최해운
    • 경영과학
    • /
    • 제10권2호
    • /
    • pp.111-120
    • /
    • 1993
  • The most important factors for a product to survive in the market are cost and quality. In recent years, quality proceeds to cost. There are many techniques of use to improve the quality of a product. One of the techniques is applying statistical methods (especially Taguchi method) to real operational conditions for a continuous manufacturing process in P company. There are 91 factors to control in the process. So, we predetermined 7 main effect factors and 6 interactive effect factors by statistical methods and advices of engineers. With these 13 factors, we determined the optimal level of operations for the process.

  • PDF

역전류 주입방식 초고압 직류차단기의 차단 기술 (Interruption Techniques of Inverse Current Injection Type of HVDC Circuit Breaker)

  • 이병윤;정진교;박경엽;신영준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.92-94
    • /
    • 1999
  • This paper describes the interruption techniques of HVDC circuit breaker which adapts inverse current injection method. A representative circuit configuration of this type of HVDC circuit breaker is presented and its operational mechanism and timing diagrams are investigated.

  • PDF

항공기 시스템 설계와 안전성평가에 운영경험 반영 사례 연구 (A Study on the Application of Operational Experience in the Stage of Aircraft System Design and Safety Assessment)

  • 구민성
    • 한국항공운항학회지
    • /
    • 제22권2호
    • /
    • pp.34-39
    • /
    • 2014
  • Airworthiness authorities specify the technical standards of airworthiness that propose minimum requirement of the commercial transport category and apply the rules in the certification process to ensure the safety of the aircraft. The Federal Aviation Administration and other national airworthiness authorities define the fatal accident risk levels for the safety assessment of the aircraft system and establish standard procedures to apply both qualitative and quantitative analysis techniques. However, an accident or incident may occur by the combination of various factors, although the aircraft is designed in accordance with the strict standards and approval by the Airworthiness Authorities. There are some key factors, such as human error, unpredictable complex system failures, degradation of the components reliability, improper maintenance task and intervals. Risk can be reduced by reflecting aircraft operational experience with similar types of aircraft in the process of aircraft development and safety assessment. Result of the root cause analysis for the Airbus A300-600 incident in which the aircraft engine reverser was deployed in the air have been introduced to reflect the design of system and related components. Also, this paper suggests to create a big-database in order to provide a feed-back to the FAR Part 25 transport category design and safety assessment of the operational experience.

나로호 킥모터 TVC 노즐 행정확인시험 및 특성 분석 (Stroke Verification Test and Operational Characteristics Analysis of KSLV-I Kick Motor TVC Nozzle)

  • 선병찬;박용규;오충석;노웅래
    • 항공우주기술
    • /
    • 제11권1호
    • /
    • pp.158-168
    • /
    • 2012
  • 본 논문에서는 나로호 2단 킥모터 TVC 노즐에 대한 행정확인시험 방법과 행정확인시험 데이터로부터 TVC 운용 특성을 분석하는 과정 및 결과에 대해 다루었다. 개루프 행정확인 시험을 통해 TVC 스트로크와 포텐셔미터 전압 간의 관계를 분석하고, 폐루프 행정확인시험을 통해 노즐정렬오차, TVC 구동오차, TVC 중립위치, 플렉스씰 노즐의 회전중심위치, 비행시험후 분석에 사용할 노즐각 환산계수 등을 분석할 수 있음을 보였다. 아울러, 나로호 1호기 및 2호기 TVC 시스템에 대해 행정확인시험을 수행한 결과 TVC 운용 관련 모든 파라미터가 정상 범위 내에서 설정되었음을 정량적인 수치로써 제시하였다.

Investigation of water length effects on the modal behavior of a prototype arch dam using operational and analytical modal analyses

  • Sevim, Baris;Bayraktar, Alemdar;Altunisik, Ahmet Can
    • Structural Engineering and Mechanics
    • /
    • 제37권6호
    • /
    • pp.593-615
    • /
    • 2011
  • This study determines the water length effects on the modal behavior of a prototype arch dam using Operational and Analytical Modal Analyses. Achievement of this purpose involves construction of a prototype arch dam-reservoir-foundation model under laboratory conditions. In the model, reservoir length was taken to be as much as three times the dam height. To determine the experimental dynamic characteristics of the arch dam using Operational Modal Analysis, ambient vibration tests were implemented for empty reservoir and three different reservoir water lengths. In the ambient vibration tests, the dam was vibrated by natural excitations provided from small impact effects and the response signals were measured using sensitive accelerometers. Operational Modal Analysis software process signals collected from the ambient vibration tests, and Enhanced Frequency Domain Decomposition and Stochastic Subspace Identification techniques estimated modal parameters of the dams. To validate the experimental results, 3D finite element model of the prototype arch dam was modeled by ANSYS software for empty reservoir and three different reservoir water lengths, and dynamic characteristics of each model were determined analytically. At the end of the study, experimentally and analytically identified dynamic characteristics compared to each other. Also, changes on the natural frequencies along to water length are plotted as graphs. Results suggest that reservoir water complicates the modal behavior of the arch dam significantly.