• Title/Summary/Keyword: operational frequencies

Search Result 137, Processing Time 0.021 seconds

Dynamic Response Measurements and Analysis on a 10 kW Class Vertical Axis Wind Turbine (10 kW급 수직축 풍력터빈에 대한 구조물 동적응답 계측 및 분석)

  • Yi, Jin-Hak;Kim, Wonsul;Han, Taek Hee;Yim, Sungyul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.27 no.1
    • /
    • pp.107-113
    • /
    • 2017
  • The dynamic characteristics including natural frequencies and excitation frequencies are evaluated for a small 10 kW vertical axis wind turbine. Acceleration responses were measured at 12 distributed locations for impact vibration tests, ambient vibration tests during non-operational and operational conditions, and braking tests during operational condition. The natural frequencies for the lowest 2 bending modes and the first torsional mode were estimated and also the excitation frequencies, i.e. 1P, 2P, 4P, were also estimated according to the rotational speed using the responses under operational conditions (i.e. power generation condition).

Reduction of Radiated Noise in a Reciprocating Compressor (왕복동식 압축기의 방사소음 저감)

  • Kim, Yong-Tae;Lee, Jin-Woo;Joo, Jae-Man
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.431-434
    • /
    • 2005
  • Generally, noise in a reciprocating compressor is attributed to the driving force of a pump. However, close examination shows that the noise heard by customers finally results from radiation of a shell in a compressor, the noise caused by both transmission through a shell and resonance with the natural frequency of a shell. Therefore, the peak frequencies contributing to the overall level of a compressor' noise are closely concerned with vibration of a shell. That's why radiated noise by vibration can be reduced by changing the mode of a shell and by shifting the peak frequencies to other ranges, which are not globally related with the overall noise level. In this paper, the main peak frequencies are analyzed to reduce the radiated noise of a shell, and the vibration characteristics of a shell are examined through Frequency Response Function and Finite Element Analysis. Moreover, the Operational Deflection Shape for a shell is measured with consideration of real driving force of a pump. Finally, the optimum position on a shell, closely related to the main peak frequencies, is found, and the overall noise level caused by radiated noise of a shell is noticeably reduced by mass or stiffness modification of the position.

  • PDF

Effects of house load operation on PSA based on operational experiences in Korea

  • Lim, Hak Kyu;Park, Jong-hoon
    • Nuclear Engineering and Technology
    • /
    • v.52 no.12
    • /
    • pp.2812-2820
    • /
    • 2020
  • House load operation (HLO) occurs when the generator supplies power to the house load without triggering reactor trips during grid disturbances. In Korea, the HLO capability of optimized power reactor 1000 (OPR1000) plants has prevented several reactor trips. Operational experiences demonstrate the difference in the reactor trip incidence due to grid disturbances between OPR1000 plants and Westinghouse plants in Korea, attributable to the availability of the HLO capability. However, probabilistic safety assessments (PSAs) for OPR1000 plants have not considered their specific design features in the initiating event analyses. In an at-power PSA, the HLO capability can affect the initiating event frequencies of general transients (GTRN) and loss of offsite power (LOOP), resulting from transients within the grid system. The initiating event frequencies of GTRN and LOOP for an OPR1000 plant are reduced by 17.7% and 78.7%, respectively, compared to the Korean industry-average initiating event frequencies, and its core damage frequency from internal events is reduced by 15.2%. The explicit consideration of the HLO capability in initiating event analyses makes significant changes in the risk contributions of the initiating events. Consequently, for more realistic at-power PSAs in Korea, we recommend incorporating plant-specific HLO-related design features when estimating initiating event frequencies.

Vulnerability assessment of strategic buildings based on ambient vibrations measurements

  • Mori, Federico;Spina, Daniele
    • Structural Monitoring and Maintenance
    • /
    • v.2 no.2
    • /
    • pp.115-132
    • /
    • 2015
  • This paper presents a new method for seismic vulnerability assessment of buildings with reference to their operational limit state. The importance of this kind of evaluation arises from the civil protection necessity that some buildings, considered strategic for seismic emergency management, should retain their functionality also after a destructive earthquake. The method is based on the identification of experimental modal parameters from ambient vibrations measurements. The knowledge of the experimental modes allows to perform a linear spectral analysis computing the maximum structural drifts of the building caused by an assigned earthquake. Operational condition is then evaluated by comparing the maximum building drifts with the reference value assigned by the Italian Technical Code for the operational limit state. The uncertainty about the actual building seismic frequencies, typically significantly lower than the ambient ones, is explicitly taken into account through a probabilistic approach that allows to define for the building the Operational Index together with the Operational Probability Curve. The method is validated with experimental seismic data from a permanently monitored public building: by comparing the probabilistic prediction and the building experimental drifts, resulting from three weak earthquakes, the reliability of the method is confirmed. Finally an application of the method to a strategic building in Italy is presented: all the procedure, from ambient vibrations measurement, to seismic input definition, up to the computation of the Operational Probability Curve is illustrated.

The determination of effect of TiO2 on dynamic behavior of scaled concrete structure by OMA

  • Tuhta, Sertac
    • Advances in nano research
    • /
    • v.11 no.6
    • /
    • pp.641-648
    • /
    • 2021
  • In this article, the dynamic parameters (frequencies, mode shapes, damping ratios) of the scaled concrete structure and the dynamic parameters (frequencies, mode shapes, damping ratios) of the entire outer surface of titanium dioxide, 80 micron in thickness are compared using operational modal analysis method. Ambient excitation was provided from micro tremor ambient vibration data on ground level. Enhanced Frequency Domain Decomposition (EFDD) was used for the output only modal identification. From this study, a good correlation between mode shapes was found. Titanium dioxide applied to the entire outer surface of the scaled concrete structure has an average of 11.78% difference in frequency values and 10.15% in damping ratios, proving that nanomaterials can be used to increase rigidity in structures, in other words, for reinforcement. Another important result determined in the study was the observation of the adherence of titanium dioxide and similar nanomaterials mentioned in the introduction to concrete structure surfaces was at the highest level.

The determination of effect of TiO2 on dynamic behavior of scaled WPC warehouse by OMA

  • Tuhta, Sertac
    • Advances in nano research
    • /
    • v.12 no.1
    • /
    • pp.65-72
    • /
    • 2022
  • The dynamic properties (frequencies, mode shapes, damping ratios) of the scaled WPC warehouse are compared using the operational modal analysis approach to the dynamic parameters (frequencies, mode shapes, damping ratios) of the full outer surface of titanium dioxide, 70 micron in thickness. Micro tremor ambient vibration data on ground level was used to provide ambient excitation. For the output-only modal identification, Enhanced Frequency Domain Decomposition (EFDD) was used. This study discovered a strong correlation between mode shapes. Titanium dioxide applied to the entire outer surface of the scaled WPC warehouse results in an average 14.05 percent difference in frequency values and 7.61 percent difference in damping ratios, demonstrating that nanomaterials can be used to increase rigidity in structures, or for reinforcement. Another significant finding in the study was the highest level of adherence of titanium dioxide and similar nanomaterials mentioned in the introduction to WPC structure surfaces.

An Experimental Study on Tooth-Meshing Frequency Components in Noise/Vibration of a Gearbox Under Operational Conditions (기어 박스 구동시 회전수 변화에 따른 이 맞물림 주파수 소음/진동 성분의 증폭에 대한 실험적 연구)

  • Lee, Seong-Hun;Kim, Kwang-Joon;Ha, Jae-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1096-1101
    • /
    • 2000
  • In machine tools, often a gearbox is installed to control the rotating speed of spindle, which sometimes generates problems of noise and vibration due to errors in tooth-meshing. In this study, the characteristics of, noise and vibration of given gearbox for a machine tool are analyzed experimentally. From the measurement, it was observed that the tooth-meshing component of the sound pressure level from the gearbox took its maximum at a specific operational speed. Therefore, the main content of this study is to investigate the reason why the above mentioned characteristics are observed. By investigating the natural frequencies of the components in gearbox, it was found that the natural frequencies of the rotating gear-shaft and gearbox for twisting mode were closely related to the first and second peak of sound pressure levels respectively. Thereform, in this study, those relations were identified by the impact test of rotating gear-shaft and-gearbox. In addition, we inserted the rubber between housing and bed, and analyze the effect of the rubber insertion on noise reduction by Operational Deflection Shapes.

  • PDF

Vibration modelling and structural modification of combine harvester thresher using operational modal analysis and finite element method

  • Zare, Hamed Ghafarzadeh;Maleki, Ali;Rahaghi, Mohsen Irani;Lashgari, Majid
    • Structural Monitoring and Maintenance
    • /
    • v.6 no.1
    • /
    • pp.33-46
    • /
    • 2019
  • In present study, Operational Modal Analysis (OMA) was employed to carry out the dynamic and vibration analysis of the threshing unit of the combine harvester thresher as a mechanical component. The main study is to find the causes of vibration and to decrease it to enhance the lifetime and efficiency of the threshing unit. By utilizing OMA, structural modal parameters such as mode shapes, natural frequencies, and damping ratio was calculated. The combine harvester was excited by engine to vibrate different parts and accelerometer sensor collected acceleration signals at different speeds, and OMA was utilized by nonparametric and frequency analysis methods to obtain modal parameters while vibrating in real working conditions. Afterwards, finite element model was designed from the thresher and updated using the data obtained from the modal analysis. Using the conducted analyses, it was specified that proximity of the thresher pass frequency to one of the natural frequencies (16.64 Hz) was the most important effect of vibration in the thresher. Modification process of the structure was carried out by increasing mass required for changing the natural frequency location of the first mode to 12.4 Hz in order to reduce resonance and vibration of the thresher.

A Study on the Electrical Magnetic Excitation Force and Noise Characteristics in Motor of Interior Permanent magnetic Type (영구자석 매입형 BLDC 모터의 전자기적 가진력 및 소음특성에 관한 연구)

  • Ko, Hong-Seok;Eun, Hee-Kwang;Kim, Kwang-Joon;Shin, Hyoun-Jeong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1139-1146
    • /
    • 2000
  • The frequencies of principal noise in interior permanent motor originate form two sources. One is torque ripple that is composed of cogging torque, magnetic torque ripple and reluctance torque ripple. The other is induced by natural frequencies. In this paper, the torque ripple and its influence on noise was examined by theoretical analysis. Understanding relation of dynamic characteristics and noise, natural frequencies and mode shapes were obtained by experimentation and operational deflection shape was observed. Finally, the method of predicting frequencies of principal noise was proposed.

  • PDF

Ambient vibration testing of Berta Highway Bridge with post-tension tendons

  • Kudu, Fatma Nur;Bayraktar, Alemdar;Bakir, Pelin Gundes;Turker, Temel;Altunisik, Ahmet Can
    • Steel and Composite Structures
    • /
    • v.16 no.1
    • /
    • pp.21-44
    • /
    • 2014
  • The aim of this study is to determine the dynamic characteristics of long reinforced concrete highway bridges with post-tension tendons using analytical and experimental methods. It is known that the deck length and height of bridges are affected the dynamic characteristics considerably. For this purpose, Berta Bridge constructed in deep valley, in Artvin, Turkey, is selected as an application. The Bridge has two piers with height of 109.245 m and 85.193 m, and the total length of deck is 340.0 m. Analytical and experimental studies are carried out on Berta Bridge which was built in accordance with the balanced cantilever method. Finite Element Method (FEM) and Operational Modal Analysis (OMA) which considers ambient vibration data were used in analytical and experimental studies, respectively. Finite element model of the bridge is created by using SAP2000 program to obtain analytical dynamic characteristics such as the natural frequencies and mode shapes. The ambient vibration tests are performed using Operational Modal Analysis under wind and human loads. Enhanced Frequency Domain Decomposition (EFDD) and Stochastic Subspace Identification (SSI) methods are used to obtain experimental dynamic characteristics like natural frequencies, mode shapes and damping ratios. At the end of the study, analytical and experimental dynamic characteristic are compared with each other and the finite element model of the bridge was updated considering the material properties and boundary conditions. It is emphasized that Operational Modal Analysis method based on the ambient vibrations can be used safely to determine the dynamic characteristics, to update the finite element models, and to monitor the structural health of long reinforced concrete highway bridges constructed with the balanced cantilever method.