• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.035 seconds

A study on the basic test for the development of the wireless sensor monitoring system of the railroad vehicle (철도차량 무선 센서 모니터링 시스템 개발을 위한 기초연구)

  • Kim, Jae-Hoon;Oh, Jae-Geun;Park, Jun-Seo;Kim, Hyung-Jin
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.291-295
    • /
    • 2009
  • We did the blooth module test as a pre-test of wireless sensor monitoring system, which for the improving of on-condition maintenance reliability, on the train. In this test, we examined the communication environment of wireless sensor monitoring system by the acceleration date and frequency date in the real train structure during the operation. Also based on this results, we did the experimental verification of the sensor power system which use piezoelectric energy conversion technology by the theoretical modeling for the applying on the train on-condition maintenance.

  • PDF

Evaluation of Load Rejection to House Load Test at 50% Power for UCN 3

  • Lee, Chang-Gyun;Suk whun Sohn;Sohn, Jong-Joo;Seo, Jong-Tae;Lee, Sang-Keun;Kim, Youngsung;Nam, Kyu-Won;Jung, Yang-Mook;Chae, Kyeong-Sik
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05a
    • /
    • pp.398-403
    • /
    • 1998
  • The Load Rejection to House Load test at 50% power was successfully peformed during the UCN 3 PAT period. In this test, all plant control systems automatically controlled the plant from 50% power to house load operation mode. The KISPAC code, which was used in the performance analysis during the design process of UCN 3&4, predictions of the test agreed with the measured data demonstrating the validity of the code as well as the completeness of the plant design.

  • PDF

Running Stability Test of Developed Bogie for High Speed Train on the Roller Rig (주행 시험대에서의 고속전철 개발대차의 주행안정성 평가)

  • Kim, Jin-Tae;Oh, Hyeong-Sik;Jung, Hoon
    • Proceedings of the KSR Conference
    • /
    • 2002.10b
    • /
    • pp.839-844
    • /
    • 2002
  • This research aims to test the running stability of the developed bogie with maximum operating speed of 350km/h, which of Korea TGV was 300km/h. The running stability test has been executed in status of a dummy car with one developed bogie and one dummy bogie on the roller rig to embody similar operation condition. The test has been done in the two rail conditions, i.e. excitation and non-excitation, respectively. Running speed has been increased by the roller step by step. In consequence, the developed bogie was proven to be able to run upto 400 Km/h without any unstable point in the non-excitation. Vibration characteristics of carbody also was within the value specified on the UIC 515.

  • PDF

Consolidated Undrained Triaxial on Cubical Compression and Plane Clay Specimen (입방체 점토시료에 대한 압밀 비배수 삼축압축 및 평면변헝률 시험)

  • 박경기;이강일
    • Geotechnical Engineering
    • /
    • v.10 no.3
    • /
    • pp.41-54
    • /
    • 1994
  • This study aims at investigating the mechanism and operation of cubical triaxial test developed by Lade in order to obtain analysis on the clayey foundation deformation. A comparison on deviator stress, pore water pressure and stress path is made between test results of clay using the cubical consolidated undrained test as well as plane strain test.

  • PDF

Influence Analysis of Deep Excavation on the Nearby Undercrossing Road by Centrifuge Model Test

  • Huang, Hongwei;Xie, Xiongyao
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.395-406
    • /
    • 2008
  • An excavation with the depth of 32.7m will be constructed as a ventilation shaft in Shanghai metro Line 9. The excavation induced effect on a nearby undercrossing road in operation must be properly evaluated. A centrifuge model test was conducted to study the impact of deep excavation on this existing undercrossing. Detail simulation works are described in this paper. The excavation steps could be simulated in the no-stop state of centrifuge machine. And induced settlements of the undercrossing road in both parallel and vertical directions were analyzed. Protective partition cement soil piles were also simulated in the tests. Simulation test shows deep excavation has a great influence on undercrossing road and the partition pile can obviously deduce the influence.

  • PDF

A Study on VV&A Application Method for Credibility Improvement of The DM&S for C4I Test and Evaluation (C4I체계 시험평가 국방M&S 신뢰도 향상을 위한 VV&A 적용방안 연구)

  • Kim, Kyung-Hee;Kang, Seok-Joong
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.13 no.6
    • /
    • pp.1080-1090
    • /
    • 2010
  • A study for improvement of credibility on test & evaluation result of interoperability in battle management information system which focused in C4I systems is very essential in rapid change of battle field environment. Realization of effective operation process with integration of developed IT also core factor for reducing of operational response time such as information gathering from sensor to shooter, time for commander's decision making. Therefore, by required to meet of high technical T&E, meet of complex software's user requirement, long-term system development period, system integration ability's request by various linkage of systems, it is high a M&S dependency to optimal performance, interpoerability's guarantee. Especially credibility on test & evaluation using M&S is very important. This paper will propse a VV&A applied methods using other VV&A case to improve credibility of M&S on test & evaluation.

An Information Transmission Method of the DC Switchgear for Light Railway Vehicle (경량전철용 직류배전반의 정보 전송방식)

  • Lee, H.D.;Kim, S.N.;Ryu, S.P.;Lee, S.H.
    • Proceedings of the KIPE Conference
    • /
    • 2005.07a
    • /
    • pp.143-145
    • /
    • 2005
  • This paper describes the transmission method of an information using communication networks between RTU(Remote Terminal Unit) and PCU(Protection and Control System) of the DC switchgear for Light Railway Vehicle. Also the test result carried out in the laboratory was represented. In this test, transmission signal waveform, polling time, response time and request/response frame between RTU and PCU were measured. The field test including the measurements of analog signal and status of the digital logic operation of PCU was conducted in Gyeongsan Test Track.

  • PDF

A Study on the Design, Fabrication and Characteristics Test of 25KJ Superconducting Magnetic Energy Storage (25KJ 초전도 에너지 저장장치의 설계,제작 및 특성 시험)

  • 홍원표;원종수;이송엽;이승원
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.37 no.10
    • /
    • pp.683-693
    • /
    • 1988
  • For the economical and reasonable operation of electric power system according to continual increase of electric power demand and decrease of load factor, the potential application of superconducting magnertic energy storage [SMES] with high efficiency and fast response in the electric utility is receiving attractive attension. In the light of this background, to confirm the basic principle of SMES, theoretical study, design technique and fabrication procedure for superconducting coil, current lead, cryostat, measuring and protection system of SMES are described in detail. Especially, a new design technique for superconducting coil and current lead is porposed and it was proved experimentally by the performance test of SMES which is developed for the first time in our country. At the peak operating current 200A, the maximum magnetic field amd stored energy of the coil are 3.52T and 2500J, espectively. The thermal and mechanical stability of 2500J SMES is also confirmed experimetally by its characteristics test, AC loss, protection system, charge and discharge test. The experimetal results show good characteristics of energy storage system.

  • PDF

Short-term Run and Short-circuit Test of 6.6㎸/200A DC reactor Type Superconducting Fault Current Limiter (6.6㎸/200A급 DC 리액터헝 초전도한류기의 단시간운전 및 단락시험)

  • 안민철;이승제;강형구;배덕권;윤용수;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.10-13
    • /
    • 2003
  • 6.6㎸rms/200Arms DC reactor type superconducting fault current limiter (SFCL) has been developed. This paper deals with the manufacture and short-circuit test of the SFCL. DC reactor was the HTS solenoid coil whose inductance was 84mH. AC/DC power converter was performed as the dual-mode operation. The short-term run(1 sec) and short-circuit test of this SFCL was performed successfully. The experimental results have a similar tendency to the simulation results. In short-circuit test, at 2 cycles after the fault, fault current limitation rate was about 30%.

  • PDF

Effect of Differential Pressure on the Performance of Motor Operated Flexible Wedge Gate Valve (차압이 모터구동 Flexible Wedge형 게이트밸브의 성능에 미치는 영향)

  • Kim, Dae-Woong;Yoo, Seong-Yeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.2 s.257
    • /
    • pp.151-158
    • /
    • 2007
  • The mechanism of power transmission from motor torque to stem thrust and the operation characteristic of each stroke position are analyzed using the diagnostic signal, and effects of differential pressure on the performance of motor operated flexible wedge gate valve are investigated. Test facility consists of 76 mm motor operated valve(flexible wedge type), pump and pipe system. Static and dynamic test are performed separately, and two differential pressure conditions are applied in the dynamic test. To evaluate the performance of valve, test signals for the torque, thrust, current, voltage and stroke length are acquired by using UDS which is diagnosis device for motor operated valve, and each diagnostic signal is analyzed and compared. The characteristic of valve performance factors such as stem factor, rate of loading, valve factor, are evaluated, and these factors are found to be severely influenced by the fluid differential pressure.