• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 1.334 seconds

A Study on the Evaluation Method for Tensile Ring Specimen Manufactured by Filament Winding Process (필라멘트 와인딩 공법으로 제조된 링 시험편의 인장강도 평가법에 관한 연구)

  • 배창원;권순철;임철문;엄수현;김윤해
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2000.11a
    • /
    • pp.15-20
    • /
    • 2000
  • Filament winding process is a comparatively simple operation in which continuous reinforcements in the form of roving are wound over a rotating mandrel. And it is now well established as a versatile method for storage tanks and pipe for the chemical and other industries. In this study, tensile strength of a filament wound ring specimens were evaluated by split disk test fixture and dress disk test fixture. The results obtained from experiments were compared with the theoretical values obtained by the rule of mixtures in composites . And the purpose of this paper is the suggestion of an appropriate test method for the evaluation of tensile properties of filament wound structures. The tensile strength of a ring specimen tested by the dress disk test showed better agreement with the theoretical values than that of a ring specimen tested by the split disk test because the stress concentration in edges of a split disk test fixture is more severe than that of dress disk test fixture. The results showed that the tensile strength of a ring specimen was influenced by the geometry of test fixture, the continuity of fibers, fiber-tension, fiber-end and stress concentration in specimen.

  • PDF

A Study on the Optimum Evaluation Method for Tensile NOL Ring Specimen Manufactured by Filament Winding Process (Filament winding에 의해 제조된 복합재료 NOL RING시험편의 최적 인장강도 평가법에 관한 연구)

  • 권순철;임철문;배창원;엄수현;김윤해
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2000.11a
    • /
    • pp.203-207
    • /
    • 2000
  • Filament Winding Process is a comparatively simple operation in which continuous reinforcements in the form of roving are wound over a rotating mandrel. And now well established as a versatile method for storage tanks and pipe for the chemical and other industries . In this study, tensile strength of a filament wound ring specimens were evaluated by split disk test fixture and dress disk test fixture , The results obtained from experiments were compared with the theoretical values obtained by the rule of mixtures. And the purpose of this paper is the suggestion of an appropriate test method for the evaluation of tensile properties of filament wound structures .The tensile strength of a ring specimen tested by the dress disk test showed better agreement with the theoretical values than of a ring specimen tested by the split disk test because the stress concentration in edges of a split disk test fixture is more severe than that of dress disk test fixture. The results showed that the tensile strength of a ring specimen was influenced by the geometry of test fixture, the continuity of fibers, fiber-tension, fiber-end and stress concentration in specimen.

  • PDF

The Reliability Evaluation of TBN Valve Testing Extension in NPP (원자력발전소 터빈밸브 시험주기 연장시 신뢰도평가)

  • Lim, Hyuk-Soon;Lee, Eun-Chan;Lee, Keun-Sung;Hwang, Seok-Won;Seong, Ki-Yeoul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3221-3223
    • /
    • 2007
  • Recently, nuclear power plant companies have been extending the turbine valve test interval to reduce the potential of the reactor trip accompanied with a turbine valve test and to improve the NPP's economy through the reduction of unexpected plant trip or decreased operation. In these regards, the extension of the test interval for turbine valves was reviewed in detail. The effect on the destructive overspeed probability due to the test interval change of turbine valves is evaluated by Fault Tree Analysis(FTA) method. Even though the test interval of turbine valves is changed from 1 month to 3 months, the analysis result shows that the reliability of turbine over speed protection system meets acceptance criteria of 1.0E-4/yr. This result will be used as the technical basis on the extension of the test interval for turbine valves. In this paper, the propriety of the turbine valve test interval extension is explained through the review on the turbine valve test interval status of turbine overspeed protection system, the analysis on the annual turbine missile frequency and the probability evaluation of the destructive overspeed due to the test interval extension.

  • PDF

Performance Evaluation of Swing-Nose Crossing Turnout on Slab Track (2) (콘크리트궤도용 고속분기기 성능평가 (2))

  • Kim, Si-Chul;Kim, Man-Cheol;Hwang, Kwang-Ha;Lee, Dong-Ho
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.717-724
    • /
    • 2011
  • In order to commercialize the track systems including the turnouts developed in Korea, the guideline of technical and systematic performance evaluation considering local environment was established on Aug. 2010. It consists of a technical compatibility, laboratory test and in-service test. Technical compatibility and laboratory test of the domestically-developed swing-nose crossing turnout on slab track(F18.5) were evaluated according to the guideline. And then in-service test was performed for the turnout installed at the 2nd phase site of Kyung-Bu HSR. In-service test is comprised of monitoring, and field and on-board test during KTX operation, where monitoring is to check the maintainability, and field and on-board test is to confirm structural and running safety. This paper is intended to explain the requirements for the in-serve test and analyze the results of monitoring and the data measured at field and on-board. Based on the in-service test, it is proven that performance of the domestically-developed swing-nose crossing turnout on slab track(F18.5) well satisfies the requirements of the guideline.

  • PDF

The Analysis of High Frequency Signal for 7tonf-class Power Pack System of KSLV-II (한국형발사체 7톤 파워팩 시스템 고주파 신호 분석)

  • So, Younseok;Yi, Seungjae;Lee, Kwangjin;Kim, Seunghan;Han, Yeoungmin
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.20 no.3
    • /
    • pp.96-102
    • /
    • 2016
  • The 7tonf-class power pack test at turbopump test facility in Naro space center was performed for confirmations of starting/running/ending operation characteristics before 7tonf rocket engine hot-firing test. The dynamic pressure mounted on a combustion chamber of gas generator is measured under 0.2 bar which does not conditioned to the unstable combustion. The analysis results of RPM and acceleration sensors mounted on the turbopump, the power pack test was performed to the estimated RPM with the stable combustion.

Overview of Thermal Test and Practice in Developing Satellite (인공위성 개발을 위한 유닛 열시험 개요와 실제)

  • Seo, Joung-Ki;Jang, Tae-Seong;Cha, Won-Ho
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.41 no.11
    • /
    • pp.915-920
    • /
    • 2013
  • Units developed for a real satellite should pass space environmental tests and launch environment tests. Thermal Vacuum Test, one of the space environmental test, simulates extreme thermal environment encountered in on-orbit operation of satellite. Many payloads which adapt non-traditional, brand-new technology are developed by developers who is not familiar to space engineering field. There might be some possibility of mistakes which result in serious problem due to lack of experience, especially from planning to performing thermal vacuum test. In this paper, brief overview of thermal environmental test related to a satellite development is summarized in order to prepare and perform the thermal test.

Evaluation of Intraoperative Stress Radiologic Tests for Syndesmotic Injuries (수술 중 부하 영상을 이용한 원위 경비 관절 손상 진단 방법의 평가)

  • Bae, Su-Young;Chung, Hyung-Jin;Oh, Su-Chan
    • Journal of Korean Foot and Ankle Society
    • /
    • v.15 no.1
    • /
    • pp.22-26
    • /
    • 2011
  • Purpose: To report the effectiveness of adding distal fibular external rotation stress test on the traditional lateral stress Cotton test in evaluating distal tibiofibular syndesmotic injuries. Materials and Methods: We evaluated syndesmotic injuries with intraoperative stress test during treating ankle fractures from March 2009 to September 2010. External rotation of distal fibula using small elevator was added on traditional stress test in case of suspicious syndesmotic injury. We retrospectively reviewed and compared the results of each test in 44 cases for which we tried both tests. Results: In 9 cases of positive traditional lateral stress tests, positive results were obtained in all cases by additional external rotation tests. In 21 cases of negative traditional stress tests, additional stress tests results were also negative. But there were 10 cases of positive additional tests and 4 of negative additional tests in equivocal results cases by the traditional stress tests. Conclusion: Using additional external rotation stress test in case of equivocal test result by the traditional lateral stress Cotton test for evaluation of syndesmotic injury during operation for ankle fracture can be a supplemental method to clarify syndesmotic injury needs fixation.

Analysis and lest of On-line and off-line PD Testing for High Voltage Rotating Machines Stator Windings using Ceramic Coupler (세라믹 커플러를 이용한 고전압회전기 고정자권선의 On-line 및 off-line 부분방전 특성 시험 및 분석)

  • Oh, Bong-Keun;Kim, Hyun-Il;Kang, Seong-Hwa;Lim, Kee-Joe
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.20 no.10
    • /
    • pp.895-900
    • /
    • 2007
  • Partial discharge(PD) test can be performed either when the rotating machine is not operating(off-line) or during normal machine operation(on-line). This paper presents an on-line and off-line PD test on a large hydro-generator and induction motor using the same PD acquisition system(PDAS) and ceramic coupler(CC) sensor. PD signal characteristics of CC sensor proved similar with that of epoxy mica coupler(EMC) sensor as a results of PD test for simulated defect winding and frequency response test. A comparison of on-line and off-line PD test for PD characteristic parameters-phase resolved PD(PRPD), maximum PD value(Qmax) and PD occurrence energy(POE)-indicated that on-line PD test could reliably and effectively diagnose insulation conditions which were verified by off-line PD test.

A Study on the Pseudo-exhaustive Test using a Netlist of Multi-level Combinational Logic Circuits (다층 레벨 조합논리 회로의 Net list를 이용한 Pseudo-exhaustive Test에 관한 연구)

  • 이강현;김진문;김용덕
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.30B no.5
    • /
    • pp.82-89
    • /
    • 1993
  • In this paper, we proposed the autonomous algorithm of pseudo-exhaustive testing for the multi-level combinational logic circuits. For the processing of shared-circuit that existed in each cone-circuit when it backtracked the path from PO to PI of CUT at the conventional verification testing, the dependent relation of PI-P0 is presented by a dependence matrix so it easily partitioned the sub-circuits for the pseudo-exhaustive testing. The test pattern of sub-circuit's C-inputs is generated using a binary counter and the test pattern of I-inputs is synthesized using a singular cover and consistency operation. Thus, according to the test patterns presented with the recipe cube, the number of test pattrens are reduced and it is possible to test concurrently each other subcircuits. The proposed algorithm treated CUT's net-list to the source file and was batch processed from the sub-circuit partitioning to the test pattern generation. It is shown that the range of reduced ration of generated pseudo-exhaustive test pattern exhibits from 85.4% to 95.8% when the average PI-dependency of ISACS bench mark circuits is 69.4%.

  • PDF

Managing method for stud female threads used long period under high temperature on the power plants (장기간 사용된 발전설비용 고온 스터드 암나사부 관리방법)

  • Chung, Nam-Yong;Kim, Moon-Young
    • Proceedings of the KSME Conference
    • /
    • 2000.11a
    • /
    • pp.199-205
    • /
    • 2000
  • The stud female threads for stud bolts tend to degrade faster by high temperature over 450 C. Therefore, inspection for replacement cycle of stud bolts is used to carry out many kinds of method such as ultrasonic test(UT), magnetic test(MT), wobble test, visual test and hardness test. The visual inspection among those has been only applied for stud female threads generally and wobble test is often used to apply stud bolts. In this paper, wobble test is applied for evaluation of stud female threads on the contrary stud bolts especially. It is also applied three types of inspection method included wobble test on the two sites which is used for each other different operation cycle and three kinds of acquisition data are compared with evaluation methods. From the results, we have studied the characteristic exchanging of integrity evaluation data distribution according to using time and proposed managing method for female thread of stud on the power plants.

  • PDF