• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.039 seconds

Experimental Performance Evaluation of a Fire System for Apartment Buildings (공동주택 전용화재시스템의 성능평가를 위한 실험적 연구)

  • Jung, Jong-Jin;Hong, A-Reum;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.51-56
    • /
    • 2015
  • In Korea, measures to maintain sustainable fire safety performance for apartment buildings are insufficient in terms of fire-fighting products, skilled personnel, and maintenance status. Also, because of the particular features of a fire compartment, it has structural problems that are very likely to cause damage to human life when a fire occurs. Currently, problems with the fire supervisory system installed in an apartment building cannot be checked in real time, so it is difficult to identify the location of a fire accurately. Protected areas are also not assigned to each household, and residents cannot be clearly informed of the occurrence of a fire. As a consequence, safety evacuation cannot be secured. In addition, it is impossible to test the operation performance for water detectors in sprinkler fire extinguishing systems outside of the household. Therefore, an experiment was conducted to evaluate the performance of a remote fire supervisory system. The results show that the system satisfies all performance requirements. Also, an household alarm system was installed in each household to alert of any occurrence of a fire accurately, and the performance of the alarm system was improved to ensure that residents were quickly evacuated.

Analysis of Repeated Measured VAS in a Clinical Trial for Evaluating a New NSAID with GEE Method (퇴행성 관절염 환자를 대상으로 새로운 진통제 평가를 위한 임상시험자료의 GEE 분석)

  • Lim, Hoi-Jeong;Kim, Yoon-I;Jung, Young-Bok;Seong, Sang-Cheol;Ahn, Jin-Hwan;Roh, Kwon-Jae;Kim, Jung-Man;Park, Byung-Joo
    • Journal of Preventive Medicine and Public Health
    • /
    • v.37 no.4
    • /
    • pp.381-389
    • /
    • 2004
  • Objective : To compare the efficacy between SKI306X and Diclofenac by using generalized estimating equations (GEE) methodology in the analysis of correlated bivariate binary outcome data in Osteoarthritis (OA) diseases. Methods : A randomized, double-blind, active comparator-controlled, non-inferiority clinical trial was conducted at 5 institutions in Korea with the random assignment of 248 patients aged 35 to 75 years old with OA of the knee and clinical evidence of OA. Patients were enrolled in this study if they had at least moderate pain in the affected knee joint and a score larger than 35mm as assessed by VAS (Visual Analog Scale). The main exposure variable was treatment (SKI 306X vs. Diclofenac) and other covariates were age, sex, BMI, baseline VAS, center, operation history (Yes/No), NSAIDS (Y/N), acupuncture (Y/N), herbal medicine (Y/N), past history of musculoskeletal disease (Y/N), and previous therapy related with OA (Y/N). The main study outcome was the change of VAS pain scores from baseline to the 2nd and 4th weeks after treatment. Pain scores were obtained as baseline, 2nd and 4th weeks after treatment. We applied GEE approach with empirical covariance matrix and independent(or exchangeable) working correlation matrix to evaluate the relation of several risk factors to the change of VAS pain scores with correlated binary bivariate outcomes. Results : While baseline VAS, age, and acupuncture variables had protective effects for reducing the OA pain, its treatment (Joins/Diclofenac) was not statistically significant through GEE methodology (ITT:aOR=1.37, 95% CI=(0.8200, 2.26), PP:aOR=1.47, 95% CI=(0.73, 2.95)). The goodness-of-fit statistic for GEE (6.55, p=0.68) was computed to assess the adequacy of the fitted final model. Conclusions : Both ANCOVA and GEE methods yielded non statistical significance in the evaluation of non-inferiority of the efficacy between SKI306X and Diclofenac. While VAS outcome for each visit was applied in GEE, only VAS outcome for the fourth visit was applied in ANCOVA. So the GEE methodology is more accurate for the analysis of correlated outcomes.

An Analysis on Signal Control Efficiency in a Three-Leg Intersection Adopting Pedestrian Push-Button System Following Pedestrian volume (3지 교차로에서 보행자 교통량에 따른 보행자작동신호기를 이용한 신호제어효율에 관한 분석)

  • Kim, Eung-Cheol;Cho, Han-Seon;Jung, Dong-Woo;Kim, Hyoung-Soo
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.121-128
    • /
    • 2009
  • This study has proposed the signal operating system to use both semi-actuated signal control and pedestrian push-button as a way to make up for the problems of 3 leg intersections which are operated inefficiently in the signal operation, one of the methods of traffic operations. In case of the semi-actuated signal control, it can reduce delay inside the intersection by serving to uncongested traffic on the main road where there is not much traffic volume on the secondary road and push-button signal can reduce unnecessary waiting time it could happen to vehicles by operating it though there is no pedestrian. Quantitative analysis was tried regarding the average delay reduction per vehicle using VISSIM, microscopic simulation program regarding how much effect it has compared with the existing signal control system and semi-actuated signal control system when the above two advantages are collected. The field test was performed for one three-leg intersection of Incheon. According to respectively signal control method pedestrian traffic changed and executed a sensitivity analysis. The result which compares the average delay time per a vehicle of scenarios, the signal control method of using the pedestrian push-button system in comparison with the fixed signal control method showed to decrease effect of a minimum 3.7 second (10%), a maximum 5.8 second (16%). When the pedestrian traffic volume was 20% or less of the measurement traffic volume, The signal control method of using the pedestrian push-button system appeared to be more efficient the semi-actuated signal control with object intersection.

  • PDF

Assessment of Emitted Volatile Organic Compounds, Metals and Characteristic of Particle in Commercial 3D Printing Service Workplace (실제 3D 프린팅 작업장에서 발생하는 공기 중 유기화합물, 금속 및 입자특성 평가)

  • Kim, Sungho;Chung, Eunkyo;Kim, Seodong;Kwon, Jiwoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.153-162
    • /
    • 2020
  • Objectives: 3D printing technologies have become widely developed and are increasingly being used for a variety of purposes. Recently, the evaluation of 3D printing operations has been conducted through chamber test studies, and actual workplace studies have yet to be completed. Therefore, the objective of this study was to determine the emission of volatile organic compounds(VOCs), metals, and particles from printing operations at a workplace. This included monitoring conducted at a commercial 3D printing service workplace where the processes involved material extrusion, material jetting, binder jetting, vat photo polymerization, and powder bed fusion. Methods: Area samples were collected with using a Tenax TA tube for VOC emission and MCE filter for metals in the workplace. For particle monitoring, Mini Particle Samplers(MPS) were also placed in the printer, indoor work area, and outdoor area. The objective was to analyze and identify particles' size, morphology, and chemical composition using transmission electron microscopy with energy dispersive spectroscopy(TEM-EDS) in the workplace. Results: The monitoring revealed that the concentration of VOCs and metals generated during the 3D printing process was low. However, it also revealed that within the 3D printing area, the highest concentration of total volatile organic compounds(TVOC) was 4,164 ppb at the vat photopolymerization 3D printing workplace, and the lowest was 148 ppb at the material extrusion 3D printing workplace. For the metals monitoring, chromium, which, is carcinogenic for humans, was detected in the workplace. As a characteristic of the particles, nano-sized particles were also found during the monitoring, but most of them were agglomerated with large and small particles. Conclusions: Based on the monitoring conducted at the commercial 3D printing operation, the results revealed that the concentration of VOCs and metals in the workplace were within Korea's occupational exposure limits. However, due to the emission of nano-sized particles during 3D printing operations, it was recommended that the exposure to VOCs and metals in the workplace should be minimized out of concern for workers' health. It was also shown that the characteristics of particles emitted from 3D printing operations may spread widely within an indoor workplace.

k-Interest Places Search Algorithm for Location Search Map Service (위치 검색 지도 서비스를 위한 k관심지역 검색 기법)

  • Cho, Sunghwan;Lee, Gyoungju;Yu, Kiyun
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.31 no.4
    • /
    • pp.259-267
    • /
    • 2013
  • GIS-based web map service is all the more accessible to the public. Among others, location query services are most frequently utilized, which are currently restricted to only one keyword search. Although there increases the demand for the service for querying multiple keywords corresponding to sequential activities(banking, having lunch, watching movie, and other activities) in various locations POI, such service is yet to be provided. The objective of the paper is to develop the k-IPS algorithm for quickly and accurately querying multiple POIs that internet users input and locating the search outcomes on a web map. The algorithm is developed by utilizing hierarchical tree structure of $R^*$-tree indexing technique to produce overlapped geometric regions. By using recursive $R^*$-tree index based spatial join process, the performance of the current spatial join operation was improved. The performance of the algorithm is tested by applying 2, 3, and 4 multiple POIs for spatial query selected from 159 keyword set. About 90% of the test outcomes are produced within 0.1 second. The algorithm proposed in this paper is expected to be utilized for providing a variety of location-based query services, of which demand increases to conveniently support for citizens' daily activities.

The Plasma Concentrations and Systemic Toxicity of Lidocaine after Maximal or Supramaximal Recommended Doses of Epidural Administration (경막외 Lidocaine의 최대사용량과 혈중농도에 대한 고찰)

  • Park, Han-Suk;Chung, Chan-Jong;Chin, Young-Jhoon
    • The Korean Journal of Pain
    • /
    • v.12 no.1
    • /
    • pp.36-42
    • /
    • 1999
  • Background: The current maximal recommended doses of lidocaine are 7 mg/kg with $5\;{\mu}g/ml$ of epinephrine. But in clinical practice, sometimes more doses of lidocaine are required to produce adequate regional anesthesia. Method: Twenty-two healthy women patients were divided into two groups and pretreated with valium 5 mg p.o., morphine 5 mg i.m., and midazolam 2 mg i.v. before operation. Of these, 7 mg/kg of 2% lidocaine with $5\;{\mu}g/ml$ of epinephrine were given to 11 patients epidurally. Initial 3 ml of epinephrine mixed lidocaine was given as a test dose and remaining doses were given 5 ml/30 sec with 3 min intervals. Radial arterial blood were drawn at 5, 10, 15, 20, 30, 45, 60, 90, 120 min to measure plasma lidocaine concentrations. After confirming all of the peak plasma concentrations of 7 mg/kg lidocaine were absolutely under $5\;{\mu}g/ml$, the other 11 patients were given 10 mg/kg of 2% lidocaine with $5\;{\mu}g/ml$ of epinephrine epidurally and blood samplings were taken according to the same method of 7 mg/kg group. The peak plasma concentration ($C_{max}$), time to reach to $C_{max}$ ($T_{max}$), time to reach to $T_4$, maximal sensory block level, systemic toxicity, and vital sign changes were investigated. Result: $C_{max}$ was significantly higher in 10 mg/kg group ($5.1{\pm}1.3\;{\mu}g/ml$) than 7 mg/kg group($3.3{\pm}0.5\;{\mu}g/ml$), but $T_{max}$ ($10.5{\pm}2.7$ min vs $10.9{\pm}3.1$ min) was not different. Time to reach $T_4$ was significantly shorter in 10 mg/kg group ($9.5{\pm}2.7$ min) than 7 mg/kg group ($12.7{\pm}3.2$ min) but maximal sensory block level ($T_{3.7{\pm}0.7}$ vs $T_{2.7{\pm}1.0}$) was not different. In four patients of 10 mg/kg group, peak plasma concentrations exceeded $5\;{\mu}g/ml$, but no systemic toxicities appeared. No significant vital sign changes were observed. Conclusion: The current maximal recommended doses of lidocaine, merely based on body weight are not always appropriate. Further studies are needed to determine more precise guideline of maximal doses that include various pharmacokinetic components.

  • PDF

A Study on the Optimization of District Heating and Cooling Facilities (지역냉난방사업의 설비 최적화에 관한 연구)

  • Kim, Jin Hyung;Choi, Byung Ryeal
    • Environmental and Resource Economics Review
    • /
    • v.15 no.3
    • /
    • pp.505-530
    • /
    • 2006
  • For the district heating and cooling business, it is required to install energy-saving facilities using energy from waste and land fill gases such as combined heat and power(CHP). The current issues that this business faces can be summarized as below: which facilities including CHP can be economically introduced and how much of their capacities should be. Most of such issues are clearly related to the optimal plant design of the district heating and cooling business, and the prices of energy services such as heating and cooling energy, and electricity. The purpose of this study is to establish linear program model of least cost function and to practice the empirical test on a assumed district heating and cooling business area. The model could choose the optimal type of energy-producing facilities among various kinds available such as CHP's, absorption chillers, the ice-storage system, etc. CHP with the flexible heat and power ratio is also in the set of available technologies. And the model show us the optimal ration of heat producing facilities between CHP and historical heat only boiler in the service area. Some implications of this study are summarized as below. Firms may utilize this model as a tool for the analysis of their optimal size of the facilities and operation. Also, the government may refer the results to regulate resonable size of business.

  • PDF

Clients Satisfaction with Oral Hygiene Care Services System Provided by the Dental Hygiene Clinics in the Department of Dental Hygiene, Yonsei University (연세대학교 치위생학과 구강위생교육실을 방문한 대상자의 구강위생관리 서비스체계에 대한 만족도 조사)

  • Kim, Nam-Hee;Kwon, Hye-Ri;Kim, Da-Hye;Kim, Da-Hee;Kim, Min-Hee;Yoo, Seung-Hee;Choi, Jin-Ah;Chung, Won-Gyun
    • Journal of Korean society of Dental Hygiene
    • /
    • v.7 no.4
    • /
    • pp.419-431
    • /
    • 2007
  • The setting of dental hygiene clinics is very important to dental hygiene education, which is the place not only to educate students but also to care clients. The purpose of this study is to provide basic research material for improvement of dental hygiene care system in dental hygiene clinics by analyzing the client satisfaction. A questionnaire survey by means of self-entry method was conducted to find out satisfaction of the client, who was visited to the dental hygiene clinics in the department of dental hygiene, Yonsei University. An analysis of frequency, one way ANOVA and T-Test were performed through SPSS 12.0K program. 1. Most clients were mainly composed of students in Wonju College of Medicine. 2. The clients visited for scaling(85.8%) and oral examination(9.73%) were much than treatment(4.42%). 3. Clients aged 21 to 25 were relatively lower in satisfaction with the facilities, system, attitude than any other ages. 4. The dental hygiene students are the lowest group in satisfaction with the facility, system, attitude than medical and nursing students. 5. The clients satisfaction with dental hygiene clinics was decreased in reverse proportion to visiting frequency. 6. Most of the clients pointed out the problems of appointment system(54.0%) and fee(23.0%), which should be improved than any other operation conditions. 7. Most of the clients were not satisfied with chair time and pain during care. 8. Most clients recognized to receive the better care service than other dental offices(81.3%). Especially, they paid attention to oral health education using phase-contrast microscope. 9. Many clients were dissatisfied with facilities of the dental hygiene clinics(71.7%). The problems of appointment system(54.0%) and chair time of dental hygiene care services(63.6%) had also inconvenienced to clients. The dental hygiene clinics in school play a crucial role in dental hygiene education to foster the student to be competent as a professional dental hygienist in the future. Therefore, well-organized dental hygiene care program based on dental hygiene process is essential. It is also required to improve the environment of dental hygiene clinics including facilities, appointment system and fee etc.

  • PDF

Fishing investigation of vertical bottom longline fisheries in sea mount of central northern Pacific (북태평양 중부 해산어장에 있어서 저층 선주낙의 어획실태)

  • Oh, Taeg-Yun;Kim, Yeong-Seung;Cho, Sam-Kwang;Kim, In-Ok;Choi, Seok-Gwan;Koh, Jeong-Rack;Yang, Won-Seok
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.41 no.3
    • /
    • pp.188-198
    • /
    • 2005
  • This study was conducted to survey the catches of vertical bottom longline fisheries in the sea mount of central northern Pacific($30^{\circ}-42^{\circ}N$, $170^{\circ}-175^{\circ}E$), during the period of July 1 to August 25,2004 by commercial fishing vessel. The number of 57 test fishing was carried out in the central northern Pacific during 43 days and the total catches were 21,092.4kg as 19 fish species, CPUE/day and catches/day were 185 baskets and 490.5kg, respectively. Main fish species caught from the experimental fishing were Squalus mitsukurii (66.3%), Coelorhyrchus asperocephaius (11.7%) and Helicolenus avius (9.8%) and, average inside diameter for fish mouth was 4.0cm over. Catch ratio according to each fishing ground was the order of F, D, J, B and C. Catch ratio fur water depth was the order of 450-500m, 350-400m, 300-350m, 400-450m, 1000-1100m and 500-550m and, main species by water depth was Squalus mitsukurii for 300-400m, Etmopterus lucifer for 300-550m, Coelorhyrchus asperocephaius far 1,000m over. Catch ratio according to the kind of hooks was higher at the hook no.6 for Squalus mitsukurii and no. 5 for Etmopterus lucifer and, catch ratio by baits was higher at squid for Squalus mitsukurii, saury and eel for Helicolemus avius and saury for Etmopterus lucifer. Accordingly, it is thought that the extension of fishing hours is needed with the reduction of damage and loss for fishing gears during fishing operation.

Drying of Crops with Solar Heated Air -Drying of Rough Rice - (태양열을 이용한 농산물건조에 관한 연구 (I)-벼의 건조에 대하여)

  • 이문남;금동혁;류능환
    • Journal of Biosystems Engineering
    • /
    • v.3 no.2
    • /
    • pp.100-113
    • /
    • 1978
  • Drying grain with conventional artificial drying methods requires great quantities of petroleum fuels. Depletion of fossil fuel increases the need of the utilization of solar energy as an alternative to petroluem fuels for drying grain , an energy intensive agricultural operation. Many techniques for the utilization of solar energy in grain drying have been developed, however, there are many problems in adopting solar energy as an energy sources for drying grain. Futhermore, very little research has been done on solar grain drying in Korea. This study was conducted to evaluate the availability of solar energy for drying of rough rice in Chuncheon, Suweon, and Jinju areas based on 50year meteorological data, and to analyze experimentally the performance of a solar air collector for dying grain, and to find the effects of solar heated air compared to unheated air on the rate of drying and energy consumption required for drying of rough rice. The results of this study was may be summarized as follows ; 1. Monthly average daily total radiation on a horizontal surface in October was 260.6 ly/day for Chuncheon, 240.3 ly/day for Suweon , and 253.4 ly/day for Jinju area, respectively. 2. the ratio of monthly average daily diffuse radiation to daily total radiation on a horizontal surface was approximately 0.41 for Chuncheon, 0.45 for Suweon, and 0.44 for Jinju area, respectively. 3. Although the statistical distribution curves of daily total radiation for the three locations were not identical , the differences among them were not large and may be neglected for many practical purposes. 4. I was estimated that the optimum tilting angle of the collector in October was approximately 46 degrees for Chuncheon and Suweon and 45 degrees for Jinju. 5. The ratio of the total radiation on a optimum tilting plane to that on a horizontal plane was estimated to be 1.36 for Chuncheon, 1.31 for Suweon, and 1.27 for Jinju , respectively. 6. The collection efficiency of the solar air collector ranged from 47. 8 to 51. 5 percent at the air flow rates of 251. 1-372.96 $m^3$/hr. High efficiency remained nearly , constant during the best sunshine hours, 10 a.m. to 2 p.m. and decreased during other hours. More energy was collected as the air flow rate incresed. 7. The average temperature rise in the drying air from the solar collector for the test period varied from $6.5^\circC$ to $21.8^\circC$ above the ambient air temperature. 8. Solar-dried rough rice averaged 13.7 percent moisture (w.b.) after 130 hours of drying with the air flow rate of 1. 64 ccm/$m^3$, and rough rice dried with natural air averaged 15.1 percent moisture (w.b.) after 325 hours of drying with the same air flow rate. 9. Energy saving of 2.4 kwh per $m^3$ percentage point of moisture removed was obtained from solar heated air drYing. The solar bin used 53.3 percent less energy per percentage point of moisture removed than the natural air bin.

  • PDF