• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.031 seconds

Development of the KOSHA Proficiency Testing Scheme on Asbestos Analysis in Korea

  • Kwon, Jiwoon;Jang, Konghwa;Hwang, Eunsong;Kim, Ki-Woong
    • Safety and Health at Work
    • /
    • v.8 no.3
    • /
    • pp.318-321
    • /
    • 2017
  • This commentary presents the regulatory backgrounds and development of the national proficiency testing (PT) scheme on asbestos analysis in the Republic of Korea. Since 2009, under the amended Occupational Safety and Health Act, the survey of asbestos in buildings and clearance test of asbestos removal works have been mandated to be carried out by the laboratories designated by the Ministry of Employment and Labor (MOEL) in the Republic of Korea. To assess the performance of asbestos laboratories, a PT scheme on asbestos analysis was launched by the Korea Occupational Safety and Health Agency (KOSHA) on behalf of the MOEL in 2007. Participating laboratories are evaluated once a year for fiber counting and bulk asbestos analysis by phase contrast microscopy and polarized light microscopy, respectively. Currently, the number of laboratory enrollments is > 200, and the percentage of passed laboratories is > 90. The current status and several significant changes in operation, sample preparations, and statistics of assigning the reference values of the KOSHA PT scheme on asbestos analysis are presented. Critical retrospect based on the experiences of operating the KOSHA PT scheme suggests considerations for developing a new national PT scheme for asbestos analysis.

Cooling Performance of Geothermal Heat Pump Using Surface Water Heat Exchanger (지표수 열교환기 적용 지열 히트펌프 시스템의 냉방 성능)

  • Lim, Hyo Jae;Kong, Hyoung Jin;Sohn, Byonghu
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.29 no.6
    • /
    • pp.316-326
    • /
    • 2017
  • Commercial buildings and institutions are predominantly cooled, thereby dissipating excess heat to a vertical ground heat exchanger (VGHE), than heat extracted over an annual cycle. Surface waters, such as lakes and ponds, provide a cost-effective means of reducing the VGHE length, and in balancing the thermal loads to the ground. This paper presents the measurement and analysis of the cooling performance of ground-coupled heat pump (GCHP) system, using surface water heat exchanger (SWHE) submerged in an artificial pond. In order to measure the performance of the system, we installed monitoring equipment, including sensors, for assessing the temperature and power consumption, after which the operation parameters were determined. The results from the thermal performance test for the SWHE indicate that the temperatures at the outlet of the SWHE and within the pond were affected by outdoor air temperature. In addition, the results reveal similar variation trends on temperatures; however, the peak temperatures of the SWHE were somewhat greater than those of outdoor air, due to the thermal capacity of the pond. Analyzing the cooling performance over the measurement period, the average coefficient of performance (COP) of heat pump was found to be 5.71, while that for the entire system was 2.99.

A Study on the User Satisfaction of Demand Response Transport(DRT) by Quantile Regression Analysis (분위회귀분석에 의한 수요응답형교통 이용자 만족도 분석)

  • Jang, Tae Youn;Han, Woo Jin;Kim, Jeong Ho
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.15 no.3
    • /
    • pp.118-128
    • /
    • 2016
  • As the rural areas have experienced the population reduction and the aging, the service level of public transit decreases. This study analyzes the effecting factor to user satisfaction of demand response transport(DRT) as alternative to rural public transit by the quantile regression that aims at estimating either the conditional median or other quantiles of the response variable. Jeonbuk Province tested DRT operations in Dongsang of Wanju County and Sannae of Jeongup City each in 2015. The user DRT satisfaction of Wanju was higher than one of Jeongup in basic statistics analysis. The difference in satisfaction between higher quantile and lower quntile of Wanju is smaller than one of Jeongupy as a result of quantile regression analysis. Also, Wanju DRT continues the second test operation of DRT as satisfaction from Ordinary Least Squares(OLS) close to higher satisfaction quantile.

Thermal Design and Analysis for Two-Axis Gimbal-Type X-Band Antenna of Compact Advanced Satellite (차세대 중형위성용 2축 짐벌식 X-밴드 안테나의 열설계 및 궤도 열해석)

  • Chae, Bong-Geon;You, Chang-Mok;Chang, Su-Young;Kang, Eun-Su;Oh, Hyun-Ung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.4
    • /
    • pp.306-314
    • /
    • 2018
  • A two-axis gimbal-type X-band antenna for CAS(Compact Advanced Satellite) transmits large amount of image data to ground station regardless of satellite attitude and orbital motion. This antenna mounted on the external surface of the satellite is directly exposed to the extreme space with thermal environment during the orbital operation. Therefore, a proper thermal design is needed to maintain the antenna itself as well as other main components within allowable temperature range. In this study, the thermal design effectiveness of two-axis gimbal X-band antenna was verified through the thermal analysis. In addition, required power and duty cycle of heater were estimated through the thermal analysis under conditions of system level thermal vacuum test and on-orbit thermal environment. The thermal analysis results indicated that all the main components of X-band antenna satisfy the allowable temperature requirement.

A Study on Thermal Performance Evaluation Procedures of LNG Fuel Tank (LNG 연료탱크의 단열성능 평가 절차에 관한 연구)

  • Cho, Sang-Hoon;Sim, Myung-Ji;Jung, Young-Jun;Kim, Ik-Soo
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.45-52
    • /
    • 2018
  • As guidelines for exhaust gases of ship are reinforced by the International Maritime Organization, the necessity for LNG fuelled ship is emerging. The relevant research is actively progressing to develop technologies and promote commercialization. When the residual quantity of LNG fuel tank is less than 70% by consuming fuel during operation, sloshing should be considered. We applied the Type C LNG fuel tank because medium sized LNG fuelled ships are difficult to equip with re-liquefaction system. Structural integrity and thermal performance are very important, especially in LNG fuel tanks that apply to LNG fuelled ship. Through this study, we proposed evaluation procedure of thermal performance for the Type C LNG tank, and verified the validity and effectiveness of BOR(Boil-Off Rate) test Procedure by comparing and analyzing changes in temperature, pressure, BOG(Boil-Off Gas).

A Study on the Internal Control System of Fisheries Cooperative (수산업협동조합의 내부통제제도에 관한 연구)

  • 박이봉;최정윤
    • The Journal of Fisheries Business Administration
    • /
    • v.22 no.2
    • /
    • pp.101-148
    • /
    • 1991
  • The fisheries cooperative (FC) performs the economic and nonprofitable activity to get the fundamental objective of enhancing cooperative members' economic and social position. The internal control system fitted for a local FC should be required for not only solving the resulting problem from the complexity of FC environment nowaday but also delegating authorities and performance from FC Federation to a local FC by implementing the local autonomy. The methodology of this study is to empirically test and to analyze the condition of FC internal control system (FCICS) by the questionnaire survey. The actual condition of FCICS in Korea is analyzed by the questionnaire and the detailed contents are as follows : (1) sending 208 questionnaire consisting of 162 questions, and receiving 92 replies from 39 manufactures (business firms) and 15 banks in Gyungnam and Pusan area and 25 FC and 13 agricultural cooperative (AC) in Korea, (2) the analyzed results of FC and AC are treated simultaneously. In the fundamentals of above analyzed results, the evaluation model of FCICS is tried to construct from the relationship between the financial condition of FC and the internal control elements through the stepwise regression method. (1) By the stepwise regression method, the number of FC officials $(X_1)$, the experimental number of regular auditing $(X_7)$, and auditing duty years $(X_8)$ are finally accepted as independent variables, (2) and the final model becomes $Y=-1.53526+0.34455X_1+0.24513X_7+0.16585X_8$/ and this model explains to the extent of 47.826%. From the above study, following proposals are to be suggested: (1) The function and problem of internal control in FCICS is able to be improved by enforcing the function of FCICS and enriching the management's recognition of FCICS (2) The cooperative president can bring up good FC by the rational operation of FCICS according to the size and the performance pattern of FC, adding up to enhance members' economic and social position.

  • PDF

Decomposition Characteristics of PFCs for Various Plasma Discharge Methods in Dielectric Barrier Discharge (DBD 반응기에서 플라즈마 방전형태에 따른 PFCs 가스의 분해 특성)

  • Kim, Kwan-Tae;Kim, Yong-Ho;Cha, Min-Suk;Song, Young-Hoon;Kim, Seock-Joon;Ryu, Jeong-In
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.20 no.5
    • /
    • pp.625-632
    • /
    • 2004
  • Perfluorocompounds ($PFC_s$), such as tetrafluoromethane ($CF_4$) and hexafluoroethane ($C_2F_6$), have been widely used as plasma etching and chemical vapor deposition (CVD) gases for semiconductor manufacturing processes. Since these $PFC_s$ are known to cause a greenhouse effect intensively, there has been a growing interest in reducing $PFC_s$ emissions. Among various $CF_4$ decomposing techniques, a dielectric barrier discharge (DBD) is considered as one of a promising candidate because it has been successfully used for generating ozone ($O_3$) and decomposing nitrogen oxide (NO). Firstly, optimal concentration of oxygen for $CF_4$ decomposition was found to figure out how many primary and secondary reactions are associated with DBD process. Secondary, to find effective discharge method for $CF_4$ decomposition, a streamer and a glow mode in DBD are experimentally compared, which includes (i) coaxialcylinder DBD, (ii) DBD reactor packed with glass beads. and (iii) a glow mode operation with a helium gas. The test results showed that optimal concentration of oxygen was ranged 500 ppm~1% for treating 500 ppm of $CF_4$ and helium glow discharge was the most efficient one to decompose $CF_4$.

The Development of A Dynamic Traffic Assignment Technique using the Cell Transmission Theory (Cell Transmission 이론을 이용한 동적통행배정기법 개발에 관한 연구)

  • 김주영;이승재;손의영
    • Journal of Korean Society of Transportation
    • /
    • v.17 no.4
    • /
    • pp.71-84
    • /
    • 1999
  • The purpose of this study is to construct a dynamic traffic analysis model using the existing traffic flow theory in order to develope a dynamic traffic assignment technique. In this study the dynamic traffic analysis model was constructed using Daganzo's CELL TRANSMISSION THEORY which was considered more suitable to dynamic traffic assignment than the other traffic flow theories. We developed newly the diverging split module, the cost update module and the link cost function and defined the maximum waiting time decision function that Daganzo haven't defined certainly at his Papers. The output that resulted from the simulation of the dynamic traffic analysis model with test network I and II was shown at some tables and figures, and the analysis of the bottleneck and the HOV lane theory showed realistic outputs. Especially, the result of traffic assignment using the model doesn't show equilibrium status every time slice but showed that the average travel cost of every path maintains similarly in every time slice. It is considered that this model can be used at the highway operation and the analysis of traffic characteristics at a diverging section and the analysis of the HOV lane effect.

  • PDF

Experimental Study on the Suppression of low Frequency Unstable Burning Occurred in a Gas Generator Using Bundle Cylindrical Grain (다발 원통형 그레인을 사용한 가스발생기의 저주파 연소불안정 소멸에 대한 실험적 연구)

  • Sung Hong-Gye;Byun Jong-Ryul
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.8 no.3
    • /
    • pp.10-16
    • /
    • 2004
  • Untypical unstable burning with very low frequency was observed at firing test of a gas generator using bundle cylindrical grain. The pressure unbalance between inside and outside of cylindrical grain brought such a low unstable burning. The grains were radially holed so that the high pressure gas inside of grain could quickly moved outward of gain, resulting dissipation of the pressure unbalance However too many holes were required to let the burning be stable for all operation regime from low to high temperature of grain and resultantly deteriorate the Progressive increase of gas amount produced by a gas generator. So another idea using grids located both sides of a bundle grain was applied to dissipate actively large vorticities enhanced by unbalance pressure distribution in a combustor. Finally stable burning with progressively increase of gas was established by application of 5${\times}$5 grid slightly away bundle grain to move bundle gain freely in case pressure unbalance were occurred inside of combustor.

Memory Characteristics of Al2O3/La2O3/SiO2 Multi-Layer Structures for Charge Trap Flash Devices (전하 포획 플래시 소자를 위한 Al2O3/La2O3/SiO2 다층 박막 구조의 메모리 특성)

  • Cha, Seung-Yong;Kim, Hyo-June;Choi, Doo-Jin
    • Korean Journal of Materials Research
    • /
    • v.19 no.9
    • /
    • pp.462-467
    • /
    • 2009
  • The Charge Trap Flash (CTF) memory device is a replacement candidate for the NAND Flash device. In this study, Pt/$Al_2O_3/La_2O_3/SiO_2$/Si multilayer structures with lanthanum oxide charge trap layers were fabricated for nonvolatile memory device applications. Aluminum oxide films were used as blocking oxides for low power consumption in program/erase operations and reduced charge transports through blocking oxide layers. The thicknesses of $SiO_2$ were from 30 $\AA$ to 50 $\AA$. From the C-V measurement, the largest memory window of 1.3V was obtained in the 40 $\AA$ tunnel oxide specimen, and the 50 $\AA$ tunnel oxide specimen showed the smallest memory window. In the cycling test for reliability, the 30 $\AA$ tunnel oxide sample showed an abrupt memory window reduction due to a high electric field of 9$\sim$10MV/cm through the tunnel oxide while the other samples showed less than a 10% loss of memory window for $10^4$ cycles of program/erase operation. The I-V measurement data of the capacitor structures indicated leakage current values in the order of $10^{-4}A/cm^2$ at 1V. These values are small enough to be used in nonvolatile memory devices, and the sample with tunnel oxide formed at $850^{\circ}C$ showed superior memory characteristics compared to the sample with $750^{\circ}C$ tunnel oxide due to higher concentration of trap sites at the interface region originating from the rough interface.