• Title/Summary/Keyword: operation test

Search Result 5,243, Processing Time 0.036 seconds

Torque Prediction of Ball Bearings Considering Cages using Computational Fluid Dynamics (전산유체역학을 이용한 케이지가 고려된 볼 베어링의 토크 예측)

  • Jungsoo Park;Jeongsik Kim;Seungpyo Lee
    • Tribology and Lubricants
    • /
    • v.40 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Ball bearings are a major component of mechanical parts for transmitting rotation. Compared to tapered roller bearings, ball bearings offer less rolling resistance, which leads to reduced heat generation during operation. Because of these characteristics, ball bearings are widely used in electric vehicles and machine tools. The design of ball bearing cages has recently emerged as a major issue in ball bearing design. Cage design requires pre-verification of performance using theoretical or experimental formula or computational fluid dynamics (CFD). However, CFD analysis is time-consuming, making it difficult to apply in case studies for design decisions and is mainly used in performance prediction following design confirmation. To use CFD in the early stages of design, main-taining analytical accuracy while reducing the time required for analysis are necessary. Accordingly, this study proposes a laminar steady-state segment CFD technique to solve the problem of long CFD analytical times and to enable the use of CFD analysis in the early stages of design. To verify the reliability of the CFD analysis, a bearing drag torque test is performed, and the results are compared with the analytical results. The proposed laminar steady-state segment CFD technique is expected to be useful for case studies in bearing design, including cage design.

Laser micro-drilling of CNT reinforced polymer nanocomposite: A parametric study using RSM and APSO

  • Lipsamayee Mishra;Trupti Ranjan Mahapatra;Debadutta Mishra;Akshaya Kumar Rout
    • Advances in materials Research
    • /
    • v.13 no.1
    • /
    • pp.1-18
    • /
    • 2024
  • The present experimental investigation focuses on finding optimal parametric data-set of laser micro-drilling operation with minimum taper and Heat-affected zone during laser micro-drilling of Carbon Nanotube/Epoxy-based composite materials. Experiments have been conducted as per Box-Behnken design (BBD) techniques considering cutting speed, lamp current, pulse frequency and air pressure as input process parameters. Then, the relationship between control parameters and output responses is developed using second-order nonlinear regression models. The analysis of variance test has also been performed to check the adequacy of the developed mathematical model. Using the Response Surface Methodology (RSM) and an Accelerated particle swarm optimization (APSO) technique, optimum process parameters are evaluated and compared. Moreover, confirmation tests are conducted with the optimal parameter settings obtained from RSM and APSO and improvement in performance parameter is noticed in each case. The optimal process parameter setting obtained from predictive RSM based APSO techniques are speed=150 (m/s), current=22 (amp), pulse frequency (3 kHz), Air pressure (1 kg/cm2) for Taper and speed=150 (m/s), current=22 (amp), pulse frequency (3 kHz), air pressure (3 kg/cm2) for HAZ. From the confirmatory experimental result, it is observed that the APSO metaheuristic algorithm performs efficiently for optimizing the responses during laser micro-drilling process of nanocomposites both in individual and multi-objective optimization.

Real-time online damage localisation using vibration measurements of structures under variable environmental conditions

  • K. Lakshmi
    • Smart Structures and Systems
    • /
    • v.33 no.3
    • /
    • pp.227-241
    • /
    • 2024
  • Safety and structural integrity of civil structures, like bridges and buildings, can be substantially enhanced by employing appropriate structural health monitoring (SHM) techniques for timely diagnosis of incipient damages. The information gathered from health monitoring of important infrastructure helps in making informed decisions on their maintenance. This ensures smooth, uninterrupted operation of the civil infrastructure and also cuts down the overall maintenance cost. With an early warning system, SHM can protect human life during major structural failures. A real-time online damage localization technique is proposed using only the vibration measurements in this paper. The concept of the 'Degree of Scatter' (DoS) of the vibration measurements is used to generate a spatial profile, and fractal dimension theory is used for damage detection and localization in the proposed two-phase algorithm. Further, it ensures robustness against environmental and operational variability (EoV). The proposed method works only with output-only responses and does not require correlated finite element models. Investigations are carried out to test the presented algorithm, using the synthetic data generated from a simply supported beam, a 25-storey shear building model, and also experimental data obtained from the lab-level experiments on a steel I-beam and a ten-storey framed structure. The investigations suggest that the proposed damage localization algorithm is capable of isolating the influence of the confounding factors associated with EoV while detecting and localizing damage even with noisy measurements.

Research on Transportation of Personnel and Equipment for Verification of Nuclear Activities on the Korean Peninsula (한반도 원자력 활동 현장 검증을 위한 인력 및 장비 운반에 관한 연구)

  • Ji-Young Han;Su-Hui Park;Je-Wan Park;Yong-Min Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.4
    • /
    • pp.481-487
    • /
    • 2023
  • After conducting a hydrogen bomb test and launching an intercontinental ballistic missile (ICBM) in 2017, The Democratic People's Republic of Korea (North Korea, D.P.R.K.) declared the completion of its national nuclear capabilities. Currently, North Korea is refusing all nuclear inspections, but the possibility of nuclear inspections and the denuclearization process on the Korean Peninsula still exists. The Republic of Korea (South Korea, Rep. of Korea) has numerous reasons as a neighboring country to participate in North Korea's nuclear inspections and denuclearization, including technological capabilities, geographical proximity, and linguistic benefits. This study assumes nuclear inspections and verification within North Korea and aims to propose scenarios for the transportation and operation of personnel and equipment. The data and results compiled through this research are anticipated to serve as foundational information for future inspections and verifications on the Korean Peninsula. Furthermore, it is assessed that they could contribute to the development of strategies in preparation for participation in denuclearization efforts.

A Study on Improving Safety Management System's Operation of the Approved (Flight) Training Organizations Operated by Universities (대학기관 비행교육원의 효율적인 항공안전시스템(SMS) 운영을 위한 개선 연구)

  • Jun-Suk Seo;Jung-Bin Kim;Gun-Young Lee
    • Journal of the Korean Society for Aviation and Aeronautics
    • /
    • v.32 no.3
    • /
    • pp.1-14
    • /
    • 2024
  • The main purpose of this study is to improve the efficiency of the manual for the aviation safety management system of the Approved(flight) Training Organization(ATO) in Korean university institutions. To achieve such purpose, universities' aviation Safety Management System(SMS) manuals were reviewed and compared. Based on the review, the first survey for aviation experts was performed to evaluate the importance of the items. A second survey focused to analyze the importance of items with high importance, which were derived from the first survey. Through Delphi analysis, the high, low important items and non-essential items were selected. Following the Delphi analysis results, frequency analysis, t-test, bivariate correlation analysis, and exploratory factor analysis were conducted. As a result of the study, the high and low importance items were identified from the manual for the aviation safety management system of the Approved Training Organization Korean university institutions.

An efficient numerical modeling approach for coupled electrical cabinets in nuclear power plants

  • Sudeep Das Turja;Md. Rajibul Islam;Dong Van Nguyen;Dookie Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.9
    • /
    • pp.3512-3527
    • /
    • 2024
  • Seismic quantification of nonstructural components like electrical cabinets is essential to ensure the uninterrupted operation of nuclear facilities during earthquake events. This process requires experimental tests, which can be expensive, time-consuming, and limited by safety concerns and precision. As an alternative to that, numerical simulations should be done in such a way that they are capable of capturing the global dynamic behavior with minimum computational efforts. However, in the case of complex interconnected cabinets, the simplification of numerical models often poses difficulties in illustrating the real-time behavior of combined cabinet systems. On the other hand, detailed three-dimensional (3D) numerical models require lengthy time and sophisticated computational setup, indicating their expensive computational efforts. To resolve this issue, a simplified and efficient 3D modeling approach has been proposed in this study. The accuracy of the results from the new model showed an excellent match with that obtained from the responses of the experimental test. After the validation and observation of the numerical efficiency, a practical application is implemented by considering the impacts of earthquake frequency contents on the behavior of cabinet systems. From the outcomes, it is evident that this proposed modeling methodology has the potential to replace the complex combined nuclear cabinet models for earthquake evaluation.

Automatic Notification System for Nuclear Medicine Blood Test (핵의학 혈액 검사의 경고치 자동통보 시스템)

  • Sim, Seong-Jae;Yoon, Pil-Young;Lim, Soo-Yeon;Cheon, Jun-Hong;Shin, Young-Kyoon;Yu, Seon-Hui;Cho, Si-Man
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.3
    • /
    • pp.159-164
    • /
    • 2009
  • Purpose: The automatic notification system for alarm values on blood tests conducted by this hospital is designed to immediately inform the attending physician of the result of a blood test, to help the relevant patient to promptly receive proper treatment, and furthermore, to reduce the likelihood of a fatal influence to the patient. From 2004, the clinical pathology department of this hospital has been operating an automatic notification system for blood tests, in relation to the items of WBC, Hb, Plt, PB cell morphology, Malaria, PT, aPTT, BT, fibrinogen, Ca, K, Na, Cl, Mg, Glucose, Ketone, Digoxin, PKU, Homocystinuria, 17-OHP, Neonatal TSH, and Galactosemia. Recently, the blood test room of the nuclear medicine department has been operating an automatic notification system for the alarm values of a blood test, in relation to three items of TSH, FT4, and 17-${\alpha}$-OH-PGR, and the details of its operation will be described here. Materials and Methods: The subjects were newborn babies that were receiving TSH, FT4, and $17{\alpha}$-OH-PGR prescriptions from February $19^{th}$ to May $11^{st}$, 2009, and who met with the following criteria: N2340 Thyroid-Stimulating Hormone: >$10{\mu}IU/mL$ (Reference value: 0.4~5.0). N2360 Free-Thyroxine: <$0.8{\mu}g/dL$ (Reference value: 0.8~1.9), N2444 $17{\alpha}$-OH-Progesterone: >$30\;{\mu}g/mL$ (Reference value: Male (0.6~3.42), Female follicular phase (0.19~1.8). The automatic notification system was operated by entering test items, relevant treatment departments, and standard values for reporting alarm values into the OCS program, and then transmitting results that met with the input conditions to the PDAs of the prescription and the attending physician by SMS. Results: Reporting an alarm value of the nuclear medicine blood test, which can have a fatal influence on the lives of patients, will help cure patients, improve the quality of the test, and furthermore, will increase the patient's satisfaction with the prescription and treatment of the test.

  • PDF

Comparison of Results of ACL Reconstruction According to the Fixation Materials (Metal & Bioabsorbable Interference Screw and RIGIDfix) (금속, 흡수성 간섭 나사못 및 RIGIDfix를 이용한 전방 십자 인대 재건술의 결과 비교)

  • Lim Hong Chul;Wang Joon Ho;Rho Young Jin;Hwang Jin Ho
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.2
    • /
    • pp.206-214
    • /
    • 2003
  • Purpose : To analysis each clinical results after arthroscopic ACL reconstruction with using variable fixatives which are metallic and bioabsorbable interference screw, and RIGIDfix. Therefore, We reported the clinical reliability and safty of ACL reconstruction using RIGIDfix. Materials and Methods : We evaluated the results of arthroscopic ACL resconstruction with patellar tendon autograft among three groups, of which group 1 is used metal interference screw for 44 patients, group 2 used bioabsorbable interference screw for 47 patients, group 3 used RIGIDfix for 42 patients. We compared the clinical results by physical examination (anterior drawer test, Lachman test and pivot shift test), Lysholm score and KT-2000 arthrometer and compared the radiological results by measurement of tunnel and fixatives position and widening and by MRI findings. We analyzed the results by SAS 8.2 Ducan. Tukey and paired t-test Results : Physical instability was in 5 cases, which group 2 had 4 cases and group 3 had 1 case. Lysholm score improved from 59.8. 64.4, 61 to 90.1, 92.3. 92. KT-2000 arthrometer instability improved from 9.20, 10.2, 9.5 to 1.43. 1.62. 2.00 (p=0.478). Radiologically, all cases had excellent tunnel position and cyst change was observed the 8 cases in the group 2, but, all 20 cases 2nd MRI had signal change of peri-fixatives. But, no correlation of clinical results. Conclusion : No statistical difference of clinical instability was found among three groups. And femoral tunnel changes were much observed in group I, II than III. We considered the RIGIDfix has much advantages because the short operation time, better fixation position and much bone contact surface. But, further long term follow up study was needed.

  • PDF

A Study on the Surgical Hand Scrub and Surgical Glove Perforation (외과적 손씻기 및 외과용 장갑의 천공율에 대한 연구)

  • 윤혜상
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.4
    • /
    • pp.653-667
    • /
    • 1995
  • Post - operative wound infections have been a serious problem in nursing care in the operating room and appear to be strongly related to the infection occurring during the performance of operation. The purpose of this study is to identify patterns in duration of surgical hand scrub (SHS), to evaluate the method of SHS and to examine the rate of glove perforation. Subjects for this study include 244 doctors and 169 nurses working in the operative theatre of a hospital in Seoul area. Test samples and related data were collected from this medical facility between April 1, through 15, and July 1, through 5, 1995 by the author and a staff member working in the operating room. For the study, data on the SHS of doctors and nurses were obtained at the time of operation and multiple batches of surgical gloves worn by the operating doctors were collected after each operation. The duration of SHS was measured with a stop watch and the method of SHS was evaluated according to Scoring Hand Scrub Criteria (SHS Criteria) and expressed as SHS scores. For the analysis of the data, t-test was used to compare the differences in the duration and the SHS scores of doctors and nurses, and Pearson's correlation coefficient was used to examine the relationship between the SHS duration and the SHS scores. The results of the study are summarized as follows. 1) The mean time spent in each SHS was 167 seconds in nurses, and 127 seconds in doctors. The data comparing nurses and doctors indicated that there were significant differences in Our ation of SH S between these two groups (t=5.58, p=.000). 2) The mean time spent in the first SHS was 145 seconds and that in the End SHS, 135 seconds, and there was not a significant difference in the duration of the SHS between doctors and nurses (t=1.44, P=.156). 3) The mean time spent in the SHS by OS (Orthopaedic surgery) doctors was 162 seconds, 150 seconds by NS(Neurologic surgery), 121 seconds by GS(General surgery), 94 seconds by OPH(Opthalmology) and DS(Dental surgery), 82 seconds by URO(Urology), 78 seconds by PS(Plastic surgery) and 40 seconds by ENT(Ear, Nose & Throat) These also showed a significant difference in the duration of the SHS among the medical specialities (t=4.8, P=.0001). 4) The average SHS score of the nurses was 15.2, while that of doctors was 13.1. The statistical analysis showed that t-value was 3.66, p was. 000. This indicates that the nurses actually clean their hands more thoroughly than the doctors do. 5) The average SHS score of NS doctors was 15.5, 15.3 for doctors for OPH,14.3 for OS,12.7 for GS, 12.0 for DS, 11.7 for URO, 10.1 for PS, 7.5 for ENT. Comparison of the average SHS scores from 8 specialties showed that there was a significant differences in the patterns of the SHS (F=5.08, P=.000) among medical specialties. 6) It appears that the operating personnel scrub the palms and dorsum of their hand relatively well, however, less thorough the nails and fingers. 7) The more the operating personnel spend their time in hand scrubbing, the more correctly they clean their hands(r=.6427, P<.001). 8) The overall frequencies of perforation in all post-operative gloves tested was 38 out of 389 gloves (10.3%). The perforation rate for PS was 13%, 12.1% for GS,8.8% for 05, and 3.3% for NS.

  • PDF

Is Preventive Bilateral Surgery Needed in Case of Bilateral Bullae on HRCT at Unilateral Primary Spontaneous Pneumothorax (일차성 자연기흉의 고해상 CT에서 보이는 반대편 기포의 예방적 기포절제술이 필요한가?)

  • Han, Jong-Hee;Kang, Min-Woong;Yu, Jeong-Hwan;Kim, Yong-Ho;Na, Myung-Hoon;Lim, Seung-Pyung;Lee, Young;Yu, Jae-Hyeon
    • Journal of Chest Surgery
    • /
    • v.40 no.3 s.272
    • /
    • pp.215-219
    • /
    • 2007
  • Background: Due to the advancement of video assisted thoracoscopic techniques, an operation for primary spontaneous pneumothorax is now considered a common procedure. However, whether a preventive operation is necessary when a contralateral bulla is found on High Resolution Computed Tomography (HRCT) at the time of the first primary spontaneous pneumothorax attack is still unknown. In this retrospective study, it was our intension to find whether contralateral bullae are related to the occurrence of pneumothorax. Material and Method: Between January 1999 and April 2006, 550 patients were admitted to the Chungnam University hospital with primary spontaneous pneumothorax, which was confirmed by the HRCT scans in 190 patents. In these 190 patients, 159 had not received a bilateral operation after their first primary spontaneous pneumothorax attack. In these 159 patients, the relationship between the presence of contralateral bullae and the occurrence of pneumothorax was measured. Result: In these 159 patients, 67 had contralateral bullae confirmed inform the HRCT scan, and 92 had no visible contralateral bullae, During the follow up period, 6 patients (8.9%) with contralateral bullae had an occurrence of contralateral pneumothorax, and 5 patients (5.4%) without contralateral bullae had an occurrence of contralateral pneumothorax. (p=0.529 [Fisher's exact test]) Conclusion: In patients with unilateral primary pneumothorax, an HRCT scan is a useful way of confirming contralateral pulmonary bullae. However, the presence of bullae is not a significant predictive sign of an occurrence of contralateral pneumothorax. Also, surgery for pneumothorax is not completely uncomplicated, and bilateral surgery is still doubtful. A further prospective study will be required to find the relationship between the bullae found on HRCT and the occurrence of pneumothorax.