• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.046 seconds

The Effects of Supportive Nursing Intervention Using Video-Program of Operating Room Nurses before Operation on Laparoscopic Hysterectomy Patient's Anxiety (수술 전 수술실간호사의 동영상 프로그램을 활용한 지지간호중재가 자궁적출술 환자의 불안에 미치는 효과)

  • Eo, Yong-Sook;Lee, Nae-Young;Lee, Ji-Won;Cha, Hyeon-Jun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2639-2646
    • /
    • 2015
  • This study was to identify the effects of supportive nursing intervention using video-program of operating room nurses before operation on laparoscopic hysterectomy patient's anxiety. This study was nonequivalent control group pre-post test design. The data were collected from May 1 to Jun 20, 2013 and analyzed by $x^2-test$, Fisher's exact test and t-test using SPSS 20.0 program. Experimental group(who received supportive nursing intervention) and control group(who received booklet education) was respectively consisted of 25 patients who were laparoscopy hysterectomy. The anxiety(p=.002) of experimental group was significantly lower than control group. The systolic(p=.012) and diastolic(p=.045) pressure of experimental group was significantly lower than control group, but pulse wasn't. The supportive nursing intervention for preoperative patient is considered effective and useful in reducing anxiety. Further research is warranted to investigate the supportive nursing intervention long-term effect.

A New Test Algorithm for Bit-Line Sensitive Faults in High-Density Memories (고집적 메모리에서 BLSFs(Bit-Line Sensitive Faults)를 위한 새로운 테스트 알고리즘)

  • Kang, Dong-Chual;Cho, Sang-Bock
    • Journal of IKEEE
    • /
    • v.5 no.1 s.8
    • /
    • pp.43-51
    • /
    • 2001
  • As the density of memories increases, unwanted interference between cells and coupling noise between bit-lines are increased. And testing high-density memories for a high degree of fault coverage can require either a relatively large number of test vectors or a significant amount of additional test circuitry. So far, conventional test algorithms have focused on faults between neighborhood cells, not neighborhood bit-lines. In this paper, a new test algorithm for neighborhood bit-line sensitive faults (NBLSFs) based on the NPSFs(Neighborhood Pattern Sensitive Faults) is proposed. And the proposed algorithm does not require any additional circuit. Instead of the conventional five-cell or nine-cell physical neighborhood layouts to test memory cells, a three-cell layout which is minimum size for NBLSFs detection is used. Furthermore, to consider faults by maximum coupling noise by neighborhood bit-lines, we added refresh operation after write operation in the test procedure(i.e.,$write{\rightarrow}\;refresh{\rightarrow}\;read$). Also, we show that the proposed algorithm can detect stuck-at faults, transition faults, coupling faults, conventional pattern sensitive faults, and neighborhood bit-line sensitive faults.

  • PDF

The Analysis of Parallel Operating Characteristics for DC-DC Converter Using the Parallel Operation Model (병렬운전 모델을 이용한 DC-DC 컨버터의 병렬운전 특성해석)

  • Kim, Soo-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.174-182
    • /
    • 2004
  • Consideration for parallel operation in a high power system has been increased due to the advantages of parallel operation like as high productivity, simplicity of design, and redundancy of power. Based on the small signal model of DC-DC Converter, the simple and exact power stage model of parallel operation system is derived and the parallel operation system using current balance method for the uniform current distribution among the parallel operation system is proposed. Using Simulation programs, which consists of nonidentical Converter modules and changes the position of master and slave automatically, the current distribution error is kept within the limit in the parallel operation system. To verify the high performance of the proposed Converter system for parallel operation, the parallel operation test, which has 2 Converter modules of 1 kW, is accomplished. Also, the simulation result is good agreement with the experiment result in the transient and starting characteristics.

A study on relation of position of hyoidbone and upper airway dimensional change according to chin movement in persons with skeletal class III facial pattern after orthognathic surgery (골격성 3급 부정교합자시 악교정 수술후 골격이동량에 따른 설골의 위치와 상기도 변화에 관한 연구)

  • Cho, Se-Jong;Kim, Yeo-Gab
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.22 no.3
    • /
    • pp.343-350
    • /
    • 2000
  • The goal of this study is the comparison of upper airway size and change of skeletal Class I group and skeletal Class III group (before operation, within 2 weeks after operation, 6 months after operation) respectively. At first, we measured the lines between selected upper air way landmarks on lateral cephalometric x-ray film of skeletal Class I 40 persons whoes age were 23-26 years old, ,and did the same lines of landmarks of skeletal Class III 44 persons who had not been operated yet, were within 2 weeks after operation, were 6 months after operation. And we compared it respectively and analyzed it with paired t-test. We studied the relationship of those on produced data. 1. Skeletal Class III group was narrower in nasopharyngeal air way space than that of skeletal Class I group, and increased in thickness of oropharyngeal, hypopharyngeal wall within 2 weeks after operation, and reduced in nasopharyngeal, oropharyngeal air way space, and did in thickness of nasopharngeal, hypopharyngeal wall 6 months after operation. 2. Skeletal Class III group reduced in nasopharyngeal, oropharyngeal air way space, and increased in thickness of nasopharyngeal, oropharyngeal, hypopharyngeal wall within 2 weeks after operation, restored the thickness of nasopharyngeal, oropharyngeal wall, but did not restored nasopharyngeal, oropharyngeal, hypopharyngeal air way space. 3. Vertical length from hyoid bone to mandibular plane did not have signifacant difference from Class I group but after operation, it increased more than Class I group significantly. 4. The size of airway reduced after operation. Among this, oropharyngeal airway most reduced.

  • PDF

Modification of Dia. 2m-Small-scaled Rotor Test Facility (직경 2m급 축소로터 시험장치 개조 및 보완)

  • Song, Keun Woong;Lee, Jae Ha;Kim, Seoung Ho
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2012.10a
    • /
    • pp.190-195
    • /
    • 2012
  • Small-scaled Rotor Test facility(GSRTS, General Small-scaled Rotor Test Facility) in KARI could not use the test because facility aging and parts discontinued. Also in order to perform a joint international research, GSRTS modifications should be needed. So requirements of GSRTS modifications were established and according to the requirements, GSRTS modifications were conducted. Facility operation test, 6-component fixed balance calibration, Small-scaled OLS rotor performance test were performed to verify the results of GSRTS modifications. Reasonable results were obtained in comparison to calculation results. Then GSRTS ready was completed to conduct international collaborative research and wind tunnel test.

  • PDF

Reliability Assessment of Polymer Insulators by Accelerated Aging Test (가속열화시험에 의한 폴리머애자의 신뢰성 평가)

  • Han, Jae-Hong;Lee, Byung-Sung;Jung, Jong-Wook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2001.05c
    • /
    • pp.10-14
    • /
    • 2001
  • In order to assess the long-tenn reliability of polymer insulators for distribution power systems, we have developed the accelerated aging test method which can simulate the operation conditions. In this study, 3000 hours aging test for 4 kinds of polymer insulators has been completed by the developed accelerated aging test. After 3000 hours aging test, visual inspection and electrical tests were carried for identifying a change of characteristics. Some specimens showed the surface erosion and the manufacturing defect. In the electrical tests, the wet flashover voltage was significant1y decreased by the accelerated aging test. In comparison with the field-aged polymer insulators, it can be concluded that the developed test method can evaluate the long-tenn reliability within short time and screen the manufacturing defect.

  • PDF

A Study on the Evaluation of Measurement Uncertainty for the National Calibration and Test Organizations (Liquid Flow) (국가교정검사기관(액체유량)의 측정불확도 평가 및 비교연구)

  • 임기원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.12 no.11
    • /
    • pp.1012-1019
    • /
    • 2000
  • A proficiency test is one of programs which Korea Research Institute of Standards and Science(KRISS), as national metrology institute, is putting in operation for the mutual recognition arrangement. The Fluid Flow Group of KRISS evaluated the measurement capability for liquid flowmeter calibrator of the national calibration and test organizations. The uncertainty of national standard system was estimated in accordance with Guide to The Expression of Uncertainty in Measurement (ISO), and the turbine flowmeter, which was used for the round-robin test as a reference flowmeter, was characterized. The round-robin tests with the turbine flowmeter package were carried out in 1995 and 1999. The test results of the organizations and those of KRISS agreed within $\pm0.2$%. It is found thus that the organizations have the traceability of the national standard for liquid flow measurement.

  • PDF

Delay Test for Boundary-Scan based Architectures (경계면 스캔 기저 구조를 위한 지연시험)

  • 강병욱;안광선
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.6
    • /
    • pp.199-208
    • /
    • 1994
  • This paper proposes a delay fault test technique for ICs and PCBs with the boundary-scan architectures supporting ANSI/IEEE Std 1149.1-1990. The hybrid delay fault model, which comprises both of gate delay faults and path delay faults, is selected. We developed a procedure for testing delay faults in the circuits with typical boundary scan cells supporting the standard. Analyzing it,we concluded that it is impractical because the test clock must be 2.5 times faster than the system clock with the cell architect-ures following up the state transition of the TAP controller and test instruction set. We modified the boundary-scan cell and developed test instructions and the test procedure. The modified cell and the procedure need test clock two times slower than the system clock and support the ANSI/IEEE standard perfectly. A 4-bit ALU is selected for the circuits under test. and delay tests are simulated by the SILOS simulator. The simulation results ascertain the accurate operation and effectiveeness of the modified mechanism.

  • PDF

Sealing Integrity of polymeric ZnO Surge Arresters (고분자 피뢰기의 기밀특성에 관한 연구)

  • Liang, He-Jin;Han, Se-Won;Cho, Han-Goo;Kim, In-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.258-261
    • /
    • 1997
  • The sealing integrity is related to the safe operation of arrester the prime failure reason of porcelain housed arresters is moisture ingress. To be a meaningful tests a polymer arrester sealing test must be a realistic acceleration of field service. We think the test should be an accelerating course of actual temperatures, the enduring property to mechanical load and temperatures should be considered together. A union test method consisting of the thermal mechanical test and thermal cycling test is proposed to test the sealing integrity of polymeric arresters, which uses dielectric loss, leakage current 1mA DC voltage and partial discharge as the diagnostic techniques, and the test results were presented. The comparison states that the TMTCUT method is suitable fur the test of sealing integrity of polymeric arresters. .

  • PDF