• Title/Summary/Keyword: operation test

Search Result 5,243, Processing Time 0.039 seconds

Analyses and Evaluation of Gird Connected PCU for PV System (태양광발전용 계통연계형 PCU의 성능특성 분석평가)

  • So J. H.;Jung Y. S.;Yu G. J.;Choi J. Y.
    • Proceedings of the KIPE Conference
    • /
    • 2003.11a
    • /
    • pp.65-68
    • /
    • 2003
  • 3kW grid-connected photovoltaic(PV) systems and data acquisition system are constructed for performance analysis of PV system at field demonstration test center of Gwang-Ju in Korea. As climatic and irradiation conditions are varied, operation characteristics of the PV system are collected and analyzed in data acquisition system. From these results, the performances of PV systems have simulated and evaluated using simulation tool In comparison with actual value of data acquisition system of field demonstration test center. Furthermore, performance of each PV system e.g. electric power and loss factor is reviewed.

  • PDF

An Application of the Optimal Routing Algorithm for Radial Power System using Improved Branch Exchange Technique (개선된 선로교환 기법을 이용한 방사상 전력계통의 최적 라우팅 알고리즘의 적용)

  • Kim, Byeong-Seop;Sin, Jung-Rin;Park, Jong-Bae
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.6
    • /
    • pp.302-310
    • /
    • 2002
  • This paper presents an application of a improved branch exchange (IBE) algorithm with a tie branch power (TBP) flow equation to solve the Optimal Routing problem for operation of a radial Power system including power distribution system. The main objective of the Optimal Routing problem usually is to minimize the network real power loss and to improve the voltage profile in the network. The new BE algorithm adopts newly designed methods which are composed by decision method of maximum loss reduction and new index of loss exchange in loop network Thus, the proposed algorithm in this paper can search the optimal topological structures of distribution feeders by changing the open/closed states of the sectionalizing and tie switches. The proposed algorithm has been evaluated with the practical IEEE 32, 69 bus test systems and KEPCO 148 bus test system to show favorable performance gained.

A Study on the Digital DC Protection Relay through with Field Adoption Test in the DC Distribution System (직류급전시스템 시험적용 사례를 통한 디지털 직류 보호계전기에 관한 연구)

  • Ko, In-Suk;Cha, Kwang-Seok;Min, Byung-Hoon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.55 no.12
    • /
    • pp.646-652
    • /
    • 2006
  • This study identifies the comparison of Technical specification and Characteristics of DC Protection Relay(ETCPU200) used in DC Distribution System in Korea. ETCPU200 has completed Field Test and approved its capability by finding out causes of recent operations through lately developed digital DC protection relay in parallel operation at Maebong-Substation, Sangbong-Substation, Nakseongdae-Substation, Euljirosaga-Substation, Jegi-Substation and Chongyangri T/P area. It also examines additional features for efficient System Analysis and Operations.

A Study on Repair Case of Journal and Bearing Damage for 25MW Industrial Gas Turbine (25MW급 산업용 가스터빈의 저널과 베어링 손상 보수사례에 관한 연구)

  • Kim, Byung Ok;Sun, Kyung Ho;Lee, An Sung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.15 no.6
    • /
    • pp.64-69
    • /
    • 2012
  • This paper deals with the study on repair case of journal shaft and bearing damage in 25MW industrial gas turbine caused by sudden blackout, operation mistake, and logic abnormal, etc. When a serious accident such as journal and bearing damage in a gas turbine occurs, the domestic local companies having the gas turbine are dependent on manufacturer for all maintenance and repair schedule until now. This case study shows that the damaged gas turbine is normally re-operated itself in domestic by establishing repair schedule in a short period of time, repairing damage journal shaft and tilting pad bearings, and performing rotating test for a reliability check. This paper can be regarded as the important case study of emergency test run experience of the refurbished 25MW gas turbine rotor.

Tibial Nerve Block for Cerebral Palsy Patients (뇌성마비 환자의 수술적응 판정을 위한 경골신경 차단)

  • Park, Chong-Min;Kim, Young-Cheol
    • The Korean Journal of Pain
    • /
    • v.9 no.1
    • /
    • pp.232-234
    • /
    • 1996
  • For surgical Treatment of spastic deformities of the foot, selective peripheral neurotomies were introduced. These neurotomies utilize microsurgical techniques and intraoperative electrical stimulation for better identification of the function of the fascicles constituting the nerve. Selectivity is required to supress the excess of spasticity without excessive weakening of motor strength and without producing exaggerated amyotrophy. To achieve this goal, minimum one fourth of the motor fibers must be preserved. Neurotomies may be indicated when spasticity is localized to muscle or muscle groups supplied by a single or a few peripheral nerves that are easily accessible. To help the surgeon decide if neurotomy is appropriate, temporary local anesthetic block of the nerve with bupivacaine can be useful. Such a test can determine if articular limitations result from spasticity, musculotendinous contractures, or articular ankyloses because only spasticity is decreased by the test. In additon, these tests give the patient a chance to appreciate what to expect from the operation.

  • PDF

Software Fault Injection Test Methodology for the Software Verification of ISO 26262 Standards-based (ISO 26262 표준 기반의 소프트웨어 검증을 위한 소프트웨어 결함 주입 기법)

  • Lee, Sangho;Shin, Seunghwan
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.68-74
    • /
    • 2014
  • As the number of ECUs (Electronic control units) are increasing, reliability and functional stability of a software in an ECU is getting more important. Therefore the application of functional safety standards ISO 26262 is making the software more reliable. Software fault injection test (SFIT) is required as a verification technique for the application of ISO 26262. In case of applying SFIT, an artificial error is injected to inspect the vulnerability of the system which is not easily detected during normal operation. In this paper, the basic concept of SFIT will be examined and the application of SIFT based on ISO26262 will be described.

COMS SYSTEM LEVEL RF COMPATIBILITY TEST SYNTHESIS

  • Lim, Hyun-Su;Park, Durk-Jong;Yang, Hyung-Mo;Ahn, Sang-Il
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.500-503
    • /
    • 2007
  • During the COMS system level test, the RF compatibility will be performed in order to verify that there is no issue in RF interface between satellite and COMS ground station, namely SOC (Satellite Operation Center) before the launch. As used for KOMPSAT1, the RF coaxial cable was chosen to be used to connect satellite and SOC with various advantages as compared with ground antennas. As the preparation step, RF cable and required multiplexer were tested in advance. This paper suggests the way for the RF compatibility tests between the satellite and the SOC over RF cable interface and presents the estimated level diagram as the signal power analysis result.

  • PDF

Vibration Characteristics of the Tower Structure of a 750kW Wind Turbine Generator (750kW 풍력발전기 타워 구조의 진동 특성)

  • Kim, Seokhyun;Nam, Y.S.;Eun, Sungyoung
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.15 no.2 s.95
    • /
    • pp.219-224
    • /
    • 2005
  • Vibration response of the tower structure of a 750kW wind turbine (W/T) generator is investigated by measurement and analysis. Acceleration response of the W/T tower under various operation condition is monitored in real time by the vibration monitoring system using LabVIEW. Resonance state of the tower structure is diagnosed in the operating speed range. Resonance frequency range of the test model is investigated with the wind speed data of the test site. To predict the tower resonance frequency, tower is modeled as an equivalent beam with a lumped mass and Rayleigh energy method is applied. Calculated tower bending frequency is in good agreement with the measured value and the result shows that the simplified model can be used in the design stage of the W/T tower.

Design of Automatic Assembly & Evaluation System for Phone Camera Module (폰 카메라 모듈 자동 조립.평가시스템 설계)

  • Song J.Y.;Lee C.W.;Ha T.W.;Jung Y.W.;Kim Y.G.;Lee M.C.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.71-72
    • /
    • 2006
  • In this study, automatic assembly and evaluation system fer phone camera module is conceptually designed. The designed core(Auto focus & UV curing, Image Test) equipments adopts a clustering mechanism and compactible structure using index table for minimum tact time. Using a ball screw actuator and absolute encoder in each axis, we can verifies the repeatability and position accuracy of system within ${\pm}3{\mu}m$. In result of simulation test, the proposed system is expected up to 30% in productivity than manual operation.

  • PDF

Construction Technique of Miniature Rumen for the Absorption Test in the Ruminants (반추수(反芻獸)의 흡수시험(吸收試驗)을 위한 소형위(小型胃)의 조성술(造成術))

  • Kim, Kyo-joon
    • Korean Journal of Veterinary Research
    • /
    • v.24 no.1
    • /
    • pp.105-109
    • /
    • 1984
  • Five Korean native goats were employed to test the effectiveness of the two modified techniques (Method I and II) of Pawlow's pouch method, Both methods turned out to be successful and simpler than the original pawlow's pouch method. In both methods, the miniature rumens were formed on the junction of two veins; versa ruminalis sinistra and vena ruminalis dextra. Both method I and II have the advantage of shortening the operation time, but caution is necessary to prevent the fistula formation between the rumen and miniature rumen in Method I.

  • PDF