• Title/Summary/Keyword: operation test

Search Result 5,243, Processing Time 0.04 seconds

Pilot Test of Grid-Type Underground Space Considering Underground Complex Plant Operation (지하 복합플랜트 운영 중 확장을 고려한 격자형 지하공간 파일럿 테스트)

  • Chulho Lee
    • Tunnel and Underground Space
    • /
    • v.33 no.6
    • /
    • pp.472-482
    • /
    • 2023
  • The grid-type or room-and-pillar method is applied for the purpose of mining horizontally buried minerals. In this study, design and pilot test were performed to apply the room-and-pillar method which uses natural rock as a rock pillar to the construction of underground space. The area where the pilot test was conducted was in stone mine and had good rock conditions with an appropriate depth (about 30 m) to apply the pilot test. The pilot test site was selected by reviewing accessibility and ground conditions and then site construction was performed through detailed ground investigation and design. The pilot test was designed with a column shape of 8×8 m and a cross-section of 8×12 m. The blasting pattern was determined through test blasting at the site, and blasting of 3 m excavation with 89 holes was performed. Through field observations, the average width of 12.5 m and the average height of 8.3 m were measured. Therefore, it is possible to proceed similar to the cross-sectional shape considered in the design.

Development of a Test Environment for Performance Evaluation of the Vision-aided Navigation System for VTOL UAVs (수직 이착륙 무인 항공기용 영상보정항법 시스템 성능평가를 위한 검증환경 개발)

  • Sebeen Park;Hyuncheol Shin;Chul Joo Chung
    • Journal of Advanced Navigation Technology
    • /
    • v.27 no.6
    • /
    • pp.788-797
    • /
    • 2023
  • In this paper, we introduced a test environment to test a vision-aided navigation system, as an alternative navigation system when global positioning system (GPS) is unavailable, for vertical take-off and landing (VTOL) unmanned aerial system. It is efficient to use a virtual environment to test and evaluate the vision-aided navigation system under development, but currently no suitable equipment has been developed in Korea. Thus, the proposed test environment is developed to evaluate the performance of the navigation system by generating input signal modeling and simulating operation environment of the system, and by monitoring output signal. This paper comprehensively describes research procedure from derivation of requirements specifications to hardware/software design according to the requirements, and production of the test environment. This test environment was used for evaluating the vision-aided navigation algorithm which we are developing, and conducting simulation based pre-flight tests.

Effect of endurance exercise during acute stage on hindlimb muscles of stroke induced rat (지구력 운동이 급성기 뇌졸중 쥐의 뒷다리근 질량에 미치는 영향)

  • An, Gyeong-Ju;Lee, Yoon-Kyong;Im, Ji-Hae;Choi, S-Mi;Choe, Myoung-Ae
    • Journal of Korean Biological Nursing Science
    • /
    • v.2 no.2
    • /
    • pp.67-80
    • /
    • 2000
  • The purpose of this study was to identify hindlimb muscle atrophy in stroke induced rat and determine the effect of endurance exercise on body weight, weight of hindlimb muscle during 7 days after stroke induction. Thirty four male Sprague-Dawley rats with 200-270g body weight were divided into four groups : control, control+exercise(Con+Ex), stroke, and exercise after stroke(St+Ex) group. The control group and Con+Ex group received sham operation and the stroke group and St+Ex group received right MCA occlusion operation by using silicon-coated probe. The Con+Ex and St+Ex groups ran on a treadmill for 20min/day at 10m/min and $10^{\circ}grade$. Daily body weight and diet intake were measured every morning for 7 days. Cerebral infarction of stroke and St+Ex groups were identified by staining with TCC for 30minutes. The data were analyzed by Kruskal-Wallis test and Mann-Whitney U test using the SPSSWIN 9.0 program. Body weight of the control group at the 7th day increased by 18.3% significantly from the first day of experiment, that of the stroke group at the 7th day decreased by 6.7% significantly compared to the day of receiving right MCA occlusion operation. Body weight of the Con+Ex group at the 7th day increased by 10.3% significantly form the first day of experiment, that of St+Ex group at the 7th day also increased by 13.4% significantly compared to the day of receiving right MCA occlusion operation. The total amount of diet in stroke group decreased significantly compared to that of St+Ex and that of control group. In stroke group the wet weight of both sides of soleus, plantaris, and gastrocnemius muscles decreased significantly compared to that of control group. The relative weight of affected(left) plantaris and gastrocnemius muscles decreased significantly compared to that of the control group. The difference between the weight of affected and unaffected soleus, plantaris, and gastrocnemius muscles were not significant in stroke group. The wet weight of right gastrocnemius muscles in Con+Ex group increased compared to that of control group. The relative weight of right gastrocnemius muscle increased significantly compared to that of the control group. The wet weight of St+Ex group increased significantly compared to that of the stroke group in both sides of soleus, plantaris, and gastrocnemius muscles. The relative weight of affected plantaris muscle increased significantly compared to that of the stroke group. The difference between the weight of affected and unaffected soleus, plantaris, and gastrocnemius muscles were not significant in St+Ex group. Body weight and wet weight of soleus, plantaris, and gastrocnemius muscles in the St+Ex group did not recover to the values of control group. Based on these results, it can be suggested that endurance exercise during acute stage of stroke can reduce muscle atrophy related to denervation, inactivity and undernutrition.

  • PDF

A Study on Improvement of Operation Characteristics and Inspection Method of Standby Power Supply such as Emergency Induction Light using Li-ion Capacitor (리튬이온커패시터를 활용한 비상유도등 예비전원장치의 동작 특성 및 점검방법 개선에 관한 연구)

  • Jung, Jun-Chea
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.392-401
    • /
    • 2020
  • Purpose: This study analyzes the operating characteristics of a lithium ion capacitor that can be used as a standby power supply in an emergency, and determines whether the standby power supply is abnormal even by measuring the voltage using a linear proportionality characteristic during charging and discharging. The aim is to provide an experimental basis that can be done. Method: As a method for this study, first, analyze the operation principle and characteristics of the existing backup power supply and lithium ion capacitor, and then measure the voltage of the lithium ion capacitor according to the configuration and system block diagram of the induction lamp used in the experiment. We proceed with the test of the measured value of discharge power for each voltage band to check the amount of power held by the battery and the operation test experiment using induction lamps. Results: Just by checking the charging voltage using the linear proportional characteristics of lithium ion capacitors, it provides a basis for accurately inferring the effective operating time of induction lamp lamps. Conclusion: In the event of a disaster, the lithium ion capacitor is used as a spare power supply for emergency induction lamps to prevent complete discharge of emergency induction lamps, to prevent the problem of performing normal operation of the standby power supply, and to use only a simple voltage measurement to reserve power. It was intended to suggest many uses for evacuation equipment application in the future by making it possible to check whether the device is abnormal.

Perception of the Nurse on the Nursing Malpractice and Its Case (간호사고와 관련판례에 대한 임상간호사의 지각)

  • Jeong, Ji-Yun;Lee, Myung-Ha
    • Journal of Korean Academy of Nursing Administration
    • /
    • v.5 no.3
    • /
    • pp.445-462
    • /
    • 1999
  • The purpose of this study is to provide some basic data for the direction of nursing education and practice to prevent nursing malpractice as investgating perception of the nurse on the nursing malpractice and its case. Data were collected from 450 nurse working in four general hospitals which were located in Chonbuk province from November 9 to 21, 1998 through questionnare. The structured instruments developed by the reseacher were used for collecting data. The Results were as follows: 1) As for the cognition of the nursing malpractice case, the transfusion accident was 37.3%, the side-effects of KCL injection(19.3%), hymen rupture by uterus cancer test, the side-effects of aminophyllin injections on dyspnea patient and the others were 10% below. 2) With regard to the channel of the perception of the nursing malpractice case, mass-communication was taken first and followed through by neighbors, In-service education, school education, continuing education 3) As for the direct${\cdot}$indirect experience of the nursing malpractice case, transfusion accident was 51.3%, the fall of NPO patient after an operation 40.1%, the side-effect of KCL injection 32.5%, suicide of the psychiatric patient 32.5%, and the others were 30% below. 4) The possibility of nursing malpractice case was an average 2.57(${\pm}$0.91) and the highest was the fall of the NPO patient after an operation. 5) The perception on the responsibility of the nursing malpractice in its case was indicated as a joint-fault in ten nursing malpractice instances. As compared to the real decision, nurse's perception of the responsibility in the fall of the NPO patient after an operation, the side-effect of KCL injection, the tracheal edema of the patient who had a thyroid operation, the suicide of psychiatric patient, the hymen rupture by uterus cancer test accorded real decisions. But the other cases were different from the real decisions. These cases were perceived as ones of joint fault even in cases determined as Dr's single fault cases or those in which both doctor and nurse were declared free of fault. 6) Knowledge levels of the nursing malpractice, school education and In-service education were perceived as low but anxiety levels of the malpractice were high. 7) With regard to the countmeasure of the hospital after nursing malpractice, the rate answered as "the practice settled the accident temporarily and forced the person in charge to be punished" was highest. In conclusion, the level of the cognition of the clinical nurse on nursing malpractice cases was low. As nurses' perception on the responsibility of the nursing malpractice case was compared to the real decision, there was a difference in five cases out of the ten cases.

  • PDF

An Improvement Plan of the Interactive ROK Army Interactive Electronic Technical Manuals (육군 전자식 기술교범 개선방안 연구)

  • Lee, Pan-Ju;Shim, Sang-Ryul
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.3
    • /
    • pp.399-406
    • /
    • 2020
  • The R.O.K Army has developed and operated TM to maintain the operation of weapons systems since its establishment. As more modern weapons systems were developed, the more efficient operation was limited by a large quantity. As a countermeasure, the DAPA has operated the IETM using the KAIS TOOL since 2003. However, 16 years later, they were shunned by operators for software instability and other reasons. Based on the results of an operational test and evaluation team of the Army headquarters, the analysis results of software instability, limited compatibility and integration, limited real-time updates, etc. were analyzed. It was confirmed that KAIS development tools were urgently needed. Therefore, in order to solve this current problem for the Army IETM, the first phase of this paper focused on improving the IETM by maintaining the application present, the second of the Army Electronic Technology manual, phase going to propose improvement plans for operational test and evaluation by lining 11 elements of comprehensive logistics support with an electronic technology code.

Biodegradability of Artificial Bait for Blue Crab Pots and Its Effect on Seawater Quality (꽃게 통발용 인공미끼의 생분해도 및 해양수질 영향)

  • Jeong, Byung-Gon;Koo, Jae-Geun;Chang, Ho-Young
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.12 no.2
    • /
    • pp.96-103
    • /
    • 2009
  • The biodegradability in water of the artificial baits for blue crab pots which were made of intestines of mackerel, tuna and grinded krill were studied. The biodegradability of artificial bait was evaluated with the effective capacity of 10L water tank which was made of acryl pipe at the velocity of 1m/d and hydraulic retention time of 12 hours. For the 23 days operation time, all artificial baits were degraded fast at the early stage of operation time and stabilized within 5 days after start up. The rates of biodegradation were different depending on the raw materials of artificial baits. In terms of degradation rate of organic matter which can be expressed as COD, artificial bait made of tunas intestine showed the fastest degradation rate. On the other hand, in terms of degradation rate of nitrogenous matter which can be expressed as ammonia nitrogen, artificial bait made of mackerels intestine showed the fastest degradation rate. In order to evaluate the effect of artificial bait on marine ecosystem, seawater qualities including SS, COD, DO, nitrogen, phosphorus were determined depending on depth and location during 2 days test operation period. It is apparent that the effect of artificial bait on seawater quality was negligible when comparing seawater quality of test operation area with control area.

  • PDF

Comparative study on the estimated blood loss follwing to orthognathic surgeries (다양한 악교정 술식 조합에 따른 실혈양의 비교 연구)

  • Jang, Jin-Hyun;Kim, Jin-Woo;Park, Sung-Ho;Kim, Myung-Rae;Kim, Sun-Jong
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.4
    • /
    • pp.272-277
    • /
    • 2011
  • Purpose: The aim of this study was to compare the estimated blood loss and determine the change in hemoglobin depending on the combination of each orthognathic surgery. Subjects and Methods: The subjects of this study were patients who underwent orthognathic surgery among those diagnosed with a dentofaical deformity in Mok-Dong hospital, Ewha Womans University from 2002 to 2009. One hundred patients (men - 36, women - 64, mean age of $24.5{\pm}4.6$) participated in the study and were divided into four groups (group 1 - bilateral sagittal ramus osteotomy [BSSRO], group 2 - BSSRO+Genioplasty, group 3 - Lefort 1+BSSRO+genioplasty, group 4 - anterior segmental osteotomy on maxilla and mandible). A comparative study on the estimated blood loss (EBL), operation time, peri-operative changes in hemoglobin was performed using anesthesia records. The results were analyzed statistically using a Mann-Whitney U-test and Spearman's Rho test - SPSS 12.0 (SPSS Inc. Chicago, IL, USA). Results: In group 1 (BSSRO), the mean EBL, operation time and change in hemoglobin was $394.43{\pm}52.69$ ml, $184{\pm}42.33$ minutes, and 1.43, respectively, In group 2 (BSSRO+genioplasty), it was $556.32{\pm}63.42$ ml, $231{\pm}37.45$ minutes, and 1.80, respectively. In group 3 (Lefort 1+BSSRO+Genioplasty), it was $820.55{\pm}105.54$ ml, $320{\pm}15.41$ minutes, and 2.73, respectively. In group 4 (segmental osteotomy), it was $1025.39{\pm}160.21$ ml, $355{\pm}20.10$ minutes, and 3.33, respectively. In particular, in group 3, significant differences were observed depending on the method of the orthognathic surgery. The mean EBL in a Lefort 1 osteotomy with advancement was only 687 ml, whereas Lefort 1 osteotomy with canting correction (992 ml), even impaction (764 ml), and posterior nasal spine impaction (100 ml) showed a much higher EBL. Conclusion: From these results, the EBL and peri-operation hemoglobin increased as treatment plans became more complicated and increasing operation time. Safe orthognathic surgery should be performed by applying proper autologous transfusion plans based on the average EBL of each orthognathic surgery type.

A Study on the Effect which the Method of Deep Breathing with the Use of Incentive Spirometer has on the function of pulmonary Ventilation - In Upper Abdominal Operation Patients - (Incentive Spirometer를 사용한 심호흡 방법이 폐환기 기능에 미치는 효과에 관한 연구 -상복부 수술 환자를 대상으로-)

  • 김종혜;변영순
    • Journal of Korean Academy of Nursing
    • /
    • v.21 no.3
    • /
    • pp.268-280
    • /
    • 1991
  • The nursing intervention for the prevention of the pulmonary complication and of the function lowering of pulmonary ventilation which emerge with high generation frequency during the nursing of operation patient is necessary for performing the qualitative nursing for operation patient. So, this researcher tried this study so as to obtain the data which can be utilized for the trial of nursing intervention, by grasping the effect that the deep breathing with Incentive Spirometer has on the function of pulmonary ventilation, analysing the factor to have influence on the function of pulmonary ventilation, and applying the effective method of deep breathing to the clinic. By making 42 patients who underwent the operation of upper abdomen after admitting G Hospital in Seoul from Mar. 7, 1991 to Apr.30, 1991 as the object, they were classified into the experiment group that the deep breathing was made with the use of Incentive Spiromenter and the comparison group that the deep breathing exercise was made without the use of Incentive Spirometer. And then, by measuring Tidal Volume and Forced Vital Capacity with Respirometer and $O_2$ Saturation with Pulse Oximeter at preoperation postoperation 24 hours, 72 hours, and 120 hours data were collected. The collected data were analyzed with of, average, standard deviation, x$^2$-test, t-test and ANOVA by SPSS. The result of this study is as follows : 1. As for the hypothesis that the function of pulmonary ventilation at postoperation 24 hours, 72 hours and 120 hours will be better in the experiment group that the deep breathing was made with the use of Incentive Spirometer, in comparison with the comparison group that deep breathing was made without the use of Incentive Spirometer, experiment group and comparison group didn't show the significant difference in Tidal Volume, Foreced Vital Capacity and $O_2$ Saturation at postoperation 24 hours and 72 hours. But experiment group and comparison group showed the significant difference in Tidal Volume at postoperation 120 hours (p<0.01). So, this hypothesis was supported partially. 2. The variables that there were the significant differences about the function of pulmonary ventilation in experiment group at postoperation 24 hours stastically were smoking existence (p<0.05), and the variables that there were not significant differences about the function of pulmonary ventilation were distinction of sex, age, anesthetic duration, smoking extent, body weight, surface area of body, existence of narcotic use, regular exercise existence, and past experience existence of respiratory disease. As above result, it appeared that the method of deep breathing with the use of the Incentive Spirometer is more effective for the function recovery of pulmonary ventilation, in comparison with the deep breathing without use of Incentive Spirometer and that smoking existence was the factor to have influence on the function of pulmonary ventilation. In the aspect of clinic, the trial of nursing intervention of deep breathing with use of Incentive Spirometer is expected. And, in the aspect of study, the study through various operative site patients about the effect of Incentive Spirometer use at the clinic will have to be confirmed.

  • PDF

The Effect of Pre and Intra-Operative Warming Therapy on Tympanic Temperature Changes during Perioperative Phase in Receiving Patients with Total Hip Replacement (수술전과 수술중 피부가온요법 적응이 고관절 전치환술 환자의 수술 주기 고막체온 변화에 미치는 영향)

  • Kwon Young-Sook;Kim Eun-Hee
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.7 no.1
    • /
    • pp.86-96
    • /
    • 2000
  • The purpose of the study was to investigate the effects of Warming Therapy used with patients consistantly before and during surgery to on changes in their body temperatures. The data were collected from patients in a university hospital in Taegu between December 1, 1998 and May 31, 1999. The subjects were selected from patients who were hospitalized for total hip replacement surgery. Thirty participants were assigned to two groups : experimental(Warming Therapy) group and control group. Each group consisted of 15 patients. The research design was a repeated measurement design, using a nonequivalent control group. The Warming Therapy, using a forced-air warming blanket, that is a, 'Bair Hugger' was applied to subjects in the experimental group. The subjects in the group were treated with the 'Bair Hugger' to warm up the whole body for 40 minutes before surgery and upper body and face during the operation. The core temperature was measured using a tympanic thermometer. The body temperature of the patients was measured 13 times every 15 minutes during the surgery. After the operation the body temperature of the patients was measured 4 times every 15 minutes, from the time of arrivial in the recovery room to the time of leaving the recovery room. The SPSS Win 9.0 program was used for data analysis. Specific methods tested were done using ${\chi}^2-test$, t-test, repeated measures ANOVA. The findings of the study are as follows. 1. The first hypothesis, 'The level of tympanic temperature for the experimental group which received Warming Therapy will be higher than that of the control group during the operation', was supported (F=32.16, p=.000). 2. The second hypothesis, 'The level of tympanic temperature for the experimental group which received Warming Therapy will be higher than that of the control group after the operation', was supported.(F=33.36, p=.000) 3. During recovery, shivering was observed one patient in the experimental group and seven patients in the control group. In summary, the findings of the study suggest that the 'Warming Therapy' applied before and during the surgery was a very effective treatment for surgical patients in maintaining the core temperature during surgery

  • PDF