• Title/Summary/Keyword: operation test

Search Result 5,241, Processing Time 0.03 seconds

Numerical Assessment of LNGC Berthing Operation to FLBT (FLBT를 향해 접안하는 LNGC의 수치해석 및 안정성 평가)

  • Jung, Sung-Jun;Jung, Dong-Woo;Oh, Seung-Hoon;Kim, Yun-Ho;Jung, Dong-Ho
    • Journal of Navigation and Port Research
    • /
    • v.45 no.3
    • /
    • pp.87-94
    • /
    • 2021
  • The IMO has adopted emission standards that strictly restrict the use of bunker C oil for vessels. Accordingly, research and bunkering pilot projects for LNG fueled ships are being actively carried out, which is expected to substantially reduce environmental pollution. In this study, we have adopted the turret moored Floating LNG Bunkering Terminal (FLBT) designed to receive the LNG from LNGCs and to transfer LNG to LNG bunkering shuttles in ship to ship moored condition. Numerical simulations have been performed with a 1-year return period of wind, wave, and current. Damping values of numerical model were adjusted from the results of model tests to obtain accurate simulation results. The results confirm safe berthing operation during the 1-year return period of environmental condition. Safety depends on the direction of environment, with increasingly stable operation facilitated by the application of heading-control function of FLBT to avoid beam-sea conditions.

Dispatching Rule based Job-Shop Scheduling Algorithm with Delay Schedule for Minimizing Total Tardiness (지연 스케쥴을 허용하는 납기최소화 잡샵 스케쥴링 알고리즘)

  • Kim, Jae-Gon;Bang, June-Young
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.42 no.1
    • /
    • pp.33-40
    • /
    • 2019
  • This study focuses on a job-shop scheduling problem with the objective of minimizing total tardiness for the job orders that have different due dates and different process flows. We suggest the dispatching rule based scheduling algorithm to generate fast and efficient schedule. First, we show the delay schedule can be optimal for total tardiness measure in some cases. Based on this observation, we expand search space for selecting the job operation to explore the delay schedules. That means, not only all job operations waiting for process but also job operations not arrived at the machine yet are considered to be scheduled when a machine is available and it is need decision for the next operation to be processed. Assuming each job operation is assigned to the available machine, the expected total tardiness is estimated, and the job operation with the minimum expected total tardiness is selected to be processed in the machine. If this job is being processed in the other machine, then machine should wait until the job arrives at the machine. Simulation experiments are carried out to test the suggested algorithm and compare with the results of other well-known dispatching rules such as EDD, ATC and COVERT, etc. Results show that the proposed algorithm, MET, works better in terms of total tardiness of orders than existing rules without increasing the number of tardy jobs.

A Difference Analysis on Visual Approach Accessibility of Airline Pilots Based on Flight Experience including Non-parametric Statistical Test (정기항공사 소속 조종사의 비행경력에 따른 시계접근능력 차이 분석 : 비모수 통계검정을 포함하여)

  • Lee, Gun-Young;Hwang, Jae-Kap;Jang, Ji-Seung
    • Journal of Advanced Navigation Technology
    • /
    • v.23 no.2
    • /
    • pp.104-113
    • /
    • 2019
  • There are keen competitions among the air operators to recruit competent pilots, which could be adversely affect the safe operation of aircraft. This study is aimed to identify the correlation between the flight experience of the pilot of the air transport operator and competency on visual approach operation. About 2,400 sets of flight training data of several pilots of an air transport operator was analysed for this study. The analysis showed that most captains were able to make stabilized visual approach regardless of his/her flight experience of any type of aircraft, while the first officers were able to make a stabilized visual approach with more than 1,500 hours of flight experience for each rated type of aircraft. This should be considered during making policies for the supply and demand of pilots for the safe operation of air transport.

Tele-operation System of Unmaned Fire Truck for Real-time Fire Suppression (실시간 화재진압을 위한 원격조종 무인소방 시스템)

  • Kang, Byoung Hun;Lee, Seung-Chol
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.22 no.6
    • /
    • pp.1-6
    • /
    • 2022
  • In this research, we suggest a real-time tele-driving system for unmanned fire truck control using the LTE communication system. The operator located in the safe area could drive the unmaned fire truck by implementing the secure tele-operation in case of the emergencies and disaster situation. A prototype of the unmaned fire truck was developed with a fire canon, a high pressure pump, a ball valve and a horse reel. The effect of time delay and FPS was quantified depending on the image sizes and the effective system for realtime tele-operation was suggested. To verify the suggested system, the test was performed between an operator and an unmanned fire truck which is approximately 30km apart. In this research, the immersion tele-driving system is suggested for real-time fire suppression with a 120ms time delay using LTE communication.

Control Effect of Temperature and Humidity by Ventilation Fan Operation Methods in Wintering Honey Bee House (월동용 양봉사의 환기팬 작동방식에 따른 온 ${\cdot}$ 습도 조절효과)

  • Lee, Jong-Won;Lee, Hyun-Woo;Lee, Suk-Gun;Jin, Ran-Shu;Choi, Kwang-Soo
    • Journal of Bio-Environment Control
    • /
    • v.12 no.3
    • /
    • pp.127-131
    • /
    • 2003
  • This study was conducted to establish the ventilation fan operation schedule to be able to provide satisfactory environment for colonies in thc wintering honey bee house. The simulation and practical measuring test were conducted to verify the applicability of an existing simulation program to thc calculation of inside thermal environment condition of the house, and the environment control performance was compared between the two types of fan operation schedule to find the proper schedule. It was concluded that the program could be used to design thc materials of the enclosure and the fan operation schedule and decide the number of accommodation hives. Inside temperature of bee house controlled by the fan operation schedule B was lower than the schedule A under the similar high outside temperature condition. In the presence of the high outside temperature condition, inside air temperature of bee house could be decreased by changing fan operation schedule A to schedule B. The humidity variation in bee house controlled by the tan operation of schedule B was smaller than that by schedule A. These results indicated that the schedule B was superior in the aspect of the environment control performance.

Economical Analysis of Cervical Disc Disease by Anterior Inter-body Fusion Methods - Comparing of Bone Graft vs Plating - (경추간판 탈출 환자의 전방 고정술에 따른 경제적 분석 - 골 이식법과 금속판 고정 병행술의 비교 -)

  • Gill, Seung-Bae;Lee, Sang-Youl;Heo, Seung-Ho;Jang, Yeun-Gyu
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.2
    • /
    • pp.201-206
    • /
    • 2001
  • Objective : The purpose of this study was to assess the complications, duration of admission, cost effectiveness, radiologic stabilization of the anterior cervical bone fusion in the treatment of cervical disc disease with and without plating. Materials and Methods : Fifty-two surgically treated patients for cervical disc disease were reviewed. Group I consisted of consecutive treated patients with iliac auto-bone graft without instrumentation after anterior cervical discectomy. Group II consisted of consecutive treated patients with iliac autologous-bone graft with CASPER cervical plate fixations. Radiologic fusion was decided when loss of end plate boundary between graft bone and vertebral body and immobile, maintenance of the disc space were evident on simple dynamic plain films. The patients were discharged after the stabilization of cervical motion by films was of tained. These groups were analysed multiple variably with Mann-Whitney U-test. Results : Group I consisted of 18 patients, group II consisted of 34 patients. Mean age was $49.0{\pm}8.1years$, mean duration of admission was $17.27{\pm}10.51days$, mean costs for treatment was $1,970,000{\pm}475,000won$. In group I, mean age was 47.7(34-60) years, 16 patients had undergo on one-level operation, 2-patients had undergo on two-level operation, mean duration of admission was $28.7{\pm}10.4days$, mean costs for treatment was $2,194,473{\pm}561,639won$. The periods of stabilization was $6.6{\pm}3.36weeks$ on radiologic study. Mean periods of out patient follow up was 16.8(6-64) weeks after discharge. Mean period of radiologic follow up was 17.3(4-6) weeks after surgical operation. In group II, mean age was 49.7(37-62) years and 18 patients one-level operation, 14- patients had undergo on two-level operation and 2-patients three-level operation. Mean duration of admission was $11.24{\pm}3.29days$, mean costs for treatment was $1,850,823{\pm}389,372won$. The periods of stabilization was $5.88{\pm}7.07weeks$ on radiologic study. Mean period of out patients follow up was 16.7(4-60) weeks after discharge. Mean period of radiologic follow up was 12.4(3-52) weeks after surgical operation. The duration of admission showed statistical significance in Group II but other items showed no significant difference between two groups. Conclusions : The more economic, early life return and effective method of cervical disc disease in our series were evident in patients who had undergone, iliac bone graft and plate fixations after anterior discectomy.

  • PDF

A Study on Transient Operation Characteristics of 30kW Scale CVCF Inverter based Micro-grid (30kW급 CVCF 인버터 기반 Micro-grid의 구현 및 과도상태 운용특성에 관한 연구)

  • Lee, Hu-Dong;Choi, Sung-Sik;Ferreira, Marito;Park, Ji-Hyun;Rho, Dae-Seok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.10
    • /
    • pp.18-25
    • /
    • 2019
  • Recently, micro-grids based on a CVCF inverter have been replacing diesel generators to reduce CO2 emissions in island areas with the increase of renewable energy sources. Stable operation methods are also being researched. These micro-grids may cause energy sinking if the total output of renewable energy sources is larger than the total customer loads. In the case of energy sinking, the voltage of a CVCF battery could rapidly increase according to the condition of SOC, and blackout could occur in the micro-grid due to the operation of a protection device in a CVCF inverter. Therefore, this paper analyzes the operation characteristics of a CVCF-inverter-based micro-grid when energy sinking occurs and proposes a transient operation strategy to prevent shut-down of the CVCF inverter. A test device of a 30-kW CVCF-inverter-based micro-grid was implemented, and the transient operation characteristics for the energy sinking phenomenon are presented. The simulation results confirm that blackout can be properly prevented according to the conditions of SOC and voltage in a CVCF battery.

ANALYSIS OF SPEECH PATHOLOGIC EVALUATION FOR CHILDREN WITH ANKYLOGLOSSIA (설유착증 환아의 언어병리학적 평가)

  • Lee, Ju-Kyung;Kim, Young-Bin;Leem, Dae-Ho;Baek, Jin-A;Shin, Hyo-Keun;Ok, Seung-O
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.30 no.5
    • /
    • pp.447-456
    • /
    • 2008
  • There is close relationship between intraoral structural anomaly and speech- functional problem. Patient with cleft palate patients & ankyloglossia is a typical example, patients with structural anomaly is repaired toward normal structure by operation. Ankyloglossia may cause functional limitation even after adequate surgical treatment speech disorders being one of them. Interindividually, they vary a lot, showing typical articulation specifics. The objective of this study was to evaluate and compare speech for children with ankyloglossia and general public, to determine whether ankyloglossia is associated with articulation problem. We wanted to present criteria for indication of frenectomy. The group of subject is composed of 10 childrens with ankyloglossia and articulation problem, visited the Oral and Maxillofacial surgical unit, dental hospital, Chonbuk university. The average age is 5 Y 7M, M : F ratio is 8 : 2 at the time of speech test. Control group is composed of 10 members without oral structural anomaly. The average age is 5 Y 10M, M : F ratio is 3 : 7 at the time of speech test. Outcomes were measured the PPVT(Peabody Picture Vocabulary Test), PCAT(Picture Consonant Articulation Test), Nasometer II test result obtained each group, statistically measured by Mann-whitney's U Test. There was no difference for 'chronological age-age equivalent' between two group. There was significant difference for 'consonant accuracy' between two group, showed more lower scores in subject group. There was more 'consonant error' in subject group, mostly showed/1/,/s/. A major modality of 'consonant error' was mostly distortion and replacement. There was no significant difference between two group for nasality.

A Study on the Wearing Phenomenon Analysis of Pantograph Slider for the Subway Cars (전동차 판토그라프 주습판 마모 현상분석에 관한 연구)

  • Kim, Young-Gyu;Kwon, Seok-Jin;Won, Si-Tae;Lee, Hi-Sung
    • Journal of the Korean Society for Railway
    • /
    • v.13 no.4
    • /
    • pp.389-395
    • /
    • 2010
  • This paper is about the copper slider with high electric conductivity and resistance arc. A new copper slider which has enhanced resistance against frictional wear was developed. By alteration of its material components and manufacturing process, its material property has been enhanced. To verify its enhanced wear-resisting capacity, a laboratory test and a field test were carried out. As the laboratory test, a dynamo test was performed and its test result showed that the developed new copper slider had superior wear-resisting capacity to the currently used copper slider. The new one showed double durability of the current one and normal wearing characteristics. A filed test was performed on the Metro subway lines at service by Seoul Metro. The field test showed similar results to those from the laboratory test, which the d eveloped new copper slider has double superior durability and sound wearing patterns. Authors strongly believe that the replacement of the copper slider currently in use by the developed new one will contribute to the economic and efficient operation of the subway line system

A FLOW AND PRESSURE DISTRIBUTION OF APR+ REACTOR UNDER THE 4-PUMP RUNNING CONDITIONS WITH A BALANCED FLOW RATE

  • Euh, D.J.;Kim, K.H.;Youn, Y.J.;Bae, J.H.;Chu, I.C.;Kim, J.T.;Kang, H.S.;Choi, H.S.;Lee, S.T.;Kwon, T.S.
    • Nuclear Engineering and Technology
    • /
    • v.44 no.7
    • /
    • pp.735-744
    • /
    • 2012
  • In order to quantify the flow distribution characteristics of APR+ reactor, a test was performed on a test facility, ACOP ($\underline{A}$PR+ $\underline{C}$ore Flow & $\underline{P}$ressure Test Facility), having a length scale of 1/5 referring to the prototype plant. The major parameters are core inlet flow and outlet pressure distribution and sectional pressure drops along the major flow path inside reactor vessel. To preserve the flow characteristics of prototype plant, the test facility was designed based on a preservation of major flow path geometry. An Euler number is considered as primary dimensionless parameter, which is conserved with a 1/40.9 of Reynolds number scaling ratio. ACOP simplifies each fuel assembly into a hydraulic simulator having the same axial flow resistance and lateral cross flow characteristics. In order to supply boundary condition to estimate thermal margins of the reactor, the distribution of inlet core flow and core exit pressure were measured in each of 257 fuel assembly simulators. In total, 584 points of static pressure and differential pressures were measured with a limited number of differential pressure transmitters by developing a sequential operation system of valves. In the current study, reactor flow characteristics under the balanced four-cold leg flow conditions at each of the cold legs were quantified, which is a part of the test matrix composing the APR+ flow distribution test program. The final identification of the reactor flow distribution was obtained by ensemble averaging 15 independent test data. The details of the design of the test facility, experiment, and data analysis are included in the current paper.