• Title/Summary/Keyword: operation guideline

Search Result 413, Processing Time 0.025 seconds

Analysis of Effects of Lightning on PAV Using Computational Simulation and a Proposal to Establish Certification Guidance (전산 시뮬레이션을 통한 PAV 낙뢰 영향성 분석 및 인증기술에 관한 연구)

  • Park, Se-Woong;Kim, Yun-Gon;Kang, Yong-Seong;Myong, Rho-Shin
    • Journal of Aerospace System Engineering
    • /
    • v.13 no.6
    • /
    • pp.60-69
    • /
    • 2019
  • Companies around the world are actively developing Personal Air Vehicle (PAV) to solve the serious social problem of traffic jams. Airworthiness certification for PAV is required, since it is a manned vehicle. As with aircraft, the critical threat to the safe operation of PAV is lightning strike with strong thermal load and magnetic fields. Lightning certification issue also remains important for PAV, since there are still insufficient development of PAV-related lightning certification technologies, guidelines, and requirements. In this study, the SAE Aerospace Recommended Practice (ARP), an international standard certification guideline recognized by the Federal Aviation Administration (FAA), was analyzed. In addition, the guideline of lightning certification was applied to a PAV. The impact of lightning on PAV was also analyzed through computational software. Finally, the basis for the establishment of the PAV lightning certification guidance was presented.

Developing the Installation Guideline of Building Monitoring Systems for Hazardous Symptom Measurements with Visual Perception (시지각적 요소를 갖춘 건축물 위험징후 측정 모니터링 시스템 설치 가이드라인 개발연구)

  • Kim, Heejae;Kim, Geunyoung;Shin, Jungjae
    • Journal of the Society of Disaster Information
    • /
    • v.16 no.2
    • /
    • pp.374-382
    • /
    • 2020
  • Purpose: Recently, structural defects in old safety management facilities have led to the collapse of buildings and facilities. The purpose of this study is to develop guidelines for the installation of regular monitoring systems that determine the optimal sensor location for monitoring exhibition space building sensors equipped with visual elements in order to analyze the risk signs of exhibition space buildings and develop measurement technology. Method: The components, installation locations, alarm criteria, and management measures of the instrument are presented. Result: A measure was proposed to determine the location of sensors, secure signal processing technology for analysis by having unified visual perception, and configure optimal 'risk sign detection' based on sensor monitoring through test-bed operation. Conclusion: The results of this study can be prepared against the disasters that may arise from the collapse of exhibition buildings, and contribute to strengthening safety management capabilities.

An Empirical Study on Marketing Strategies for Improvement of Library Performance (도서관 성과 증진을 위한 마케팅 전략의 실증적 분석)

  • Kim, Hee-Sop;Park, Yong-Jae
    • Journal of the Korean Society for information Management
    • /
    • v.24 no.4
    • /
    • pp.133-152
    • /
    • 2007
  • As interior and exterior environments change rapidly with the modern IT technology, the strategies related to marketing activities which enhance the library competition have been demanded. Although many previous studies have been conducted to improve the satisfaction of the library users and to increase the use rate, only few studies focused on the marketing strategy to elevate the library performance. With suggestion of a systematic framework related to the strategies, this study aims to analyze not only the interior and exterior factors which impact on the library marketing strategies, but the strategies which may influence on its performance. To achieve this objective, we adopted a comprehensive survey targeting the various types of our domestic libraries. On the basis of the results, we proposed a guideline for the strategy operation for the librarians to enhance the library performance.

Guideline for the Diagnose of Geotechnical Structure (Underground Oil Storage Cavern) using a Microseismic Monitoring System (음향미소진동기반 모니터링 시스템을 이용한 지반구조물(유류 지하저장시설) 진단평가 가이드라인)

  • Cheon, Dae-Sung;Jung, Yong-Bok
    • Tunnel and Underground Space
    • /
    • v.28 no.4
    • /
    • pp.293-303
    • /
    • 2018
  • Monitoring is the act of collecting and analyzing accurate engineering information using various methods and instruments. The purposes of the monitoring are design verification, construction management, quality control, safety management, and diagnose of structure etc.. The diagnose evaluation of the geotechnical structures corresponds to the confirmation of the structural performance. It is aimed to judge the soundness of geotechnical structures considering the degree of damage due to the environmental change and elapsed time. Recently, microseismicity, which is widely known in Korea, can be used for safety management and diagnoses of structure as it detects the micro-damage without disturbance of the structure. This report provides guideline on the procedure for assessing an underground oil storage cavern using microseismic monitoring techniques. Guidelines cover the selection of monitoring systems, sensor array, sensor installation and operation of systems, and interpretation.

Determination of Working Area Based on Operator's Working Comfort (사용 편의성에 기초한 작업 영역의 결정)

  • Park, Sung-Joon;Jung, Eui-Seung
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.26 no.2
    • /
    • pp.88-94
    • /
    • 2000
  • For efficient operation, vital hand controls must be easily controlled by the operator from his or her normal working position. The primary working area based on the operator-perceived working comfort was developed to serve as a design guideline to the control panel layout. Six male and four female subjects voluntarily participated in the experiment in which working comfort was measured for two types of controls - knob and lever. The operator-perceived working comfort was examined for the frontal and sagittal distances from the body center and the slope of a work surface. The response surface methodology using a central composite design was employed to develop a prediction model for operator's working comfort on each type of controls. The proposed working areas based on the actual working comfort of an operator avoided the dichotomy that considers only the reachability of control devices, and showed a distinct shape, when compared to the existing normal working areas following the Farley's concept. It was shown that the distance from the body to control devices and the slope of a work surface have a quadratic relationship to the working comfort, and that the most comfortable area for seated tasks is located at the distance of about 2∼4 cm in the sagittal direction and about 42∼43 cm in the frontal direction from the shoulder, respectively. It was also found that the working comfort varies within the working area even at the positions with an equal distance from the body. It is expected that the isocomfort working area generated in the study will be used as a useful guideline for control panel layout.

  • PDF

A Study on Powder Fire Extinguisher Design with RULA Technique Used (RULA 평가기법을 활용한 분말소화기 디자인 연구)

  • Kang, Chaewoo;Kim, Dueknam
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.117-123
    • /
    • 2017
  • This study was intended to find methods of fire extinguishing system designs that can improve the equipment's usability. In this study, the fire suppression experiment through fire extinguishers and the data drawn through the experiment were analyzed, and then the guideline for the improvement of designs was presented. The procedure is as follows. A fire suppression experiment with the use of fire extinguishers was done by 43 average adults. The whole process of the fire suppression was videotaped, and then captured major scenes were analyzed with the use of RULA, a human engineering measurement tool. The analyzed data were divided into 4 steps, and then the guideline for design improvement was presented. The summary of the study is as follows. Step 1, Fire extinguisher distance step. To reduce overload occurring at the process of holding fire extinguishers suddenly, wheels are attached to the body of extinguishers, or pedestals are installed. Step 2, Fire extinguisher transportation step. The length of hose is extended, or fire fighting water is sprayed far, so that overload of legs occurring at the process of travel can be reduced. In addition, the weight of fire extinguisher shouldn't be over 2 kg. Step 3, Safety pin removal stage. Safety pins should be applied with button type, so that excessive posture of lower limbs and excessive twisting of wrists won't happen during safety pin removal process. Besides, safety pins should be designed for easy identification and operation. Step 4, Fire extinguishing agent spraying step. To reduce overload occurring at sudden spraying of fire fighting water, pressure should be increased gradually until high pressure. With the above study results applied to existing fire extinguisher design, it may contribute to reducing any fire damage.

Current Condition and Prospect of On-Site Domestic Wastewater Treatment Technologies (합병정화조 기술현황 및 전망)

  • 임연택
    • Proceedings of the Membrane Society of Korea Conference
    • /
    • 1998.06a
    • /
    • pp.95-112
    • /
    • 1998
  • Water quality in the public water course has been polluted more seriously than ever before due to the increase of the number and aremount of pollution sources such as domestic and industrial wastewater. For water quality conservation, the Korean government has been trying to construct sewage treatment facilities continually, of which treatment capacity reached to 11,452,400m$^{3}$/day in 1996. Night soil treatment facilites of m nationwide have the treatment capacity of 24,038m$^{3}$/day. But water quality has not been improved because the sewer systems were insufficient and the treatment efficiencies of sewage were not high, enough. For renovation of water quality, miscellaneous domestic wastewater must be treated because 27g BOD/day out of total 40g BOD/person-day come from miscellaneous wastewater, comparing to 13g BOD/day from night soil. However, sole treatment purifier treat only night soil from the flushing toilet. Therefore, it may be desirable to treat the miscellaneous domestic wastewater and the night soil from flushing toilet together by joint treatment purifier system as on-site domestic wastewater treatment technology. In Korea, the joint treatment purifier system, introduced in 1997, have the benefit as follows; i) good water poiluion control effect, ii ) good effect on river water flow, iii) water pollution control with sewage treatment facility, and iv) rapid pollution control effect, etc. In order to achieve a good effect as stated before, i ) strengthening effluent guideline including BOD, nitrogen and phosphorus, ii ) specializing operation to maintain high performance, and iii) supporting its construction and maintenance costs by the governmental level may be necessary: In addition, automation system of joint treatment purifier, technology for its package and compactness, and a new bio-media bio-filter with higher capacity should be further developed in agreement with a more stringent effluent guideline.

  • PDF

A study on the Development course of guideline for fostering the Rural village roads (농촌마을길 조성을 위한 가이드라인 개발 방향 연구)

  • Kim, Eun-Ja;Lee, Yoo-Kyoung;Kim, Sang-Bum;Lim, Chang-Su;Park, Mi-Jung;Choi, Jin-Ah;Lee, Jeung-Won
    • Journal of Korean Society of Rural Planning
    • /
    • v.19 no.1
    • /
    • pp.189-207
    • /
    • 2013
  • This study aimed to draw the plan elements and characteristics that should be considered in case when developing guidelines to build up roads in rural villages. Drawing the construction elements necessary for building up roads through the advanced researches, the survey was conducted for relevant experts in order to evaluate the importance of each plan element of route plan, design & construction and operation & management. The result determined total 105 contents that should be considered in case when building up roads in rural villages. The study on building up roads in rural villages as a strategy to vitalize rural areas means universal roads that connect each village with rural amenities in various values like walking tour road, visit roads and observation roads. It is considered that the development of guidelines for building up roads in rural villages could be used as a basic data to build up roads where nature, culture and history of rural areas can be effectively experienced and enjoyed.

Development of Clinical Protocol on the Correlation Between Disease Cause Pattern Identification and Pulse Wave Variables (병인변증과 요골동맥 맥상파의 특성 파악을 위한 탐색적 관찰 연구 : 임상시험 프로토콜 개발)

  • Kim, Jihye;Yu, Hana;Ku, Boncho;Kim, Hyunho;Kim, Jongyeol;Jeon, Youngju
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.28 no.6
    • /
    • pp.662-667
    • /
    • 2014
  • The purpose of this clinical study is to develop structured clinical trial protocol and guideline for improvement of safety, useful and effective of pulse diagnosis devices. As a first step, papers on pulse diagnosis and pulse diagnosis devices from 2001 and 2013 were systematically reviewed. In the next step, we have collected the opinions from the specialists, companies, and statistician in pulse diagnosis to evaluate the current condition, the state and problem of domestic clinical trial cases of pulse diagnosis device. And we have to created protocol and case report form (CRF) in regards to site condition and characteristics of pulse diagnosis devices, and showed the guideline of eligibility criteria, operation process, investigation items, evaluation items and so on. This clinical protocol will become a basic information for a researcher in designing or performing a clinical study of pulse diagnosis devices, and be used as a useful material during acquisition of good clinical data. Furthermore, we hope to enhance the invigoration of pulse diagnosis clinical trials and the performance improvement of pulse diagnosis devices.

Radiation Safety Exploration Using Radio-photoluminescence Dosimeter for Crookes Tubes in Junior and Senior High School in Japan

  • Akiyoshi, Masafumi;Do, Duy Khiem;Yamaguchi, Ichiro;Kakefu, Tomohisa;Miyakawa, Toshiharu
    • Journal of Radiation Protection and Research
    • /
    • v.46 no.3
    • /
    • pp.106-111
    • /
    • 2021
  • Background: Crookes tube is utilized in junior high and high schools in Japan to study the character of electrons and current, and not for radiological education. There is no official guideline or regulation for these radiation source to the public. Therefore, most teachers have no information about the leakage of X-rays from Crookes tube. The peak energy of X-rays is approximately 20 keV, and it is impossible to measure using conventional survey meters. Materials and Methods: Each leakage dose of low energy X-rays from 38 Crookes tube in the education field, such as junior and senior high schools in Japan, was explored by the teachers in the school using radio-photoluminescence (RPL) dosimeters. Before and after the measurements, the dosimeters were sent by postal mails. Results and Discussion: At the exploration in this study, it was estimated that the 70 ㎛ dose equivalent, Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes, at the distance of 1 m, where the Crookes tube was usually observed. However, the highest dose was estimated as 0.69 mSv by an equipment with the full power. Furthermore, one Crookes tube exhibited 0.62 mSv with minimum output power of the induction coil. This relatively large dose was reduced by the shorter distance of discharge electrodes of the induction coil. Conclusion: The leakage dose of low energy X-rays from 38 Crookes tube was explored using RPL dosimeters. It was estimated that the Hp(0.07) of X-rays from 31 Crookes tubes were smaller than 100 µSv in 10 minutes at the distance of 1 m, while some equipment radiated a higher dose. With this study, the provisional guideline for the safety operation of Crookes tube is established.