• 제목/요약/키워드: operation efficiency

검색결과 5,505건 처리시간 0.032초

차세대 전동차 대불선 시운전 시 유지보수방안 연구 (A study on advanced EMU's maintenance program on test operation in Dabul line)

  • 김영규;박세영;송정훈;안천헌;이한민
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2010년도 춘계학술대회 논문집
    • /
    • pp.2215-2222
    • /
    • 2010
  • Advanced EMU have been enhanced in terms of safe transport and maintainability. It is a new urban railway technology that enables an operation institution to cut repair and maintenance costs and customers to use convenient service at lower costs based on IT technology. If a development vehicle of Advanced EMU is completed, it will be used to test the entire advanced EMU system through sufficient performance check and reliability check prior to operation in commercial line. It will also verify efficiency, safety, punctuality and energy efficiency of transport. Accordingly, it is necessary to figure how to repair and maintain vehicles to enhance safety of Advanced EMU system in cooperation with operation during the period of comprehensive evaluation on the operation of a development vehicle in a test line. In this paper, we investigated the maintenance program of Advanced EMU on test operation in Dabul line. The test condition and operation environment of Advanced EMU in Daebul line was analyzed.

  • PDF

Analysis of Hybrid Converter with Wide Voltage Range Operation

  • Lin, Bor-Ren
    • Journal of Power Electronics
    • /
    • 제19권5호
    • /
    • pp.1099-1107
    • /
    • 2019
  • A soft switching converter with wide voltage range operation is investigated in this paper. A series resonant converter is implemented to achieve a high circuit efficiency with soft switching characteristics on power switches and rectifier diodes. To improve the weakness of the narrow voltage range in LLC converters, an alternating current (ac) power switch is used on the primary side to select a half-bridge or full-bridge resonant circuit to implement 4:1 voltage range operation. On the secondary-side, another ac power switch is adopted to select a full-wave rectifier or voltage-doubler rectifier to achiever an additional 2:1 output voltage range. Therefore, the proposed resonant converter has the capacity for 8:1 (320V~40V) wide output voltage operation. A single-stage hybrid resonant converter is employed in the study circuit instead of a two-stage dc converter to achiever wide voltage range operation. As a result, the study converter has better converter efficiency. The theoretical analysis and circuit characteristics are verified by experiments with a prototype circuit.

어선용 하이브리드 추진시스템에 관한 연구 (A Study on the Hybrid Propulsion System for Fishing Boat)

  • 오진석;조관준;박충환;함연재;곽준호;이지영
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제32권5호
    • /
    • pp.677-683
    • /
    • 2008
  • The electric propulsion system us closely related with the economical efficiency of ship operation. Fuel efficiency is mainly decided by propulsion system such as diesel engine, propulsion motor and steam turbine. The hybrid propulsion system for fishing boat consists of diesel engine and battery as propulsion power source. This paper is to design battery capacity according to power consumption with ship operation condition, and to test the power consumption of model ship in the circulating water channel. As a result. it can be known that the optimum ship operation condition affects the fuel efficiency.

High Efficiency Operation of a Switched Reluctance Generator over a Wide Speed Range

  • Yu, Siyang;Zhang, Fengge;Lee, Dong-Hee;Ahn, Jin-Woo
    • Journal of Power Electronics
    • /
    • 제15권1호
    • /
    • pp.123-130
    • /
    • 2015
  • This paper investigates the high efficiency operation of a switched reluctance generator over a wide speed range. The system efficiency is improved by optimizing the current shape. A modified angle position control (MAPC) method that can be used to optimize the current shape over a wide speed range is proposed. Simulation and experimental results are presented to validate the effectiveness of the proposed control scheme.

PV System 기반 ESS의 최적운전을 위한 설계 및 제어 특성에 관한 연구 (A Study on the Design and Control Characteristics for Optimum Operation of the PV System-based ESS)

  • 차인수;박종복;정경환
    • 한국태양에너지학회 논문집
    • /
    • 제36권5호
    • /
    • pp.19-30
    • /
    • 2016
  • In this study, realize voltage regulation $220Vac{\pm}10%$ or less, frequency fluctuation $60Hz{\pm}1%$ or less over the independent operation and grid-connected operation technologies for power stabilization relates to the ESS designed and manufactured in conjunction with solar installations and solar to compensate the output reduction due to the polarization of the solar module through the polarization prevention technology for preventing the optical module efficiency is lowered, in conjunction with the BMS inverter efficiency was more than 92%, more than 90% of the charging efficiency to the target. This study was designed in conjunction with the ESS solar power plants, grid-connected operation and independent operation, Peak-Cut, it can stabilize the grid via the Peak-Shifting operation

A Study on the Operation Method of Packaging System to Enhance Logistics Efficiency

  • Jung, Sung-Tae
    • 한국포장학회지
    • /
    • 제24권2호
    • /
    • pp.73-84
    • /
    • 2018
  • This study sought efficiency of collaboration between manufacturers and distributors by finding a way to improve logistics efficiency in order to save distribution cost and standardize packaging together with profit generation by way of simple-display packaging in discount stores. For the study purpose, the impact of products with RRP (Retail Ready Packaging) by each discount store on the collaboration achievement such as loading efficiency was observed. From this observation, an alternative packaging system that can improve logistics efficiency between manufacturers and distributors was sought and the role of distributors in distribution standardization was explored. The purpose of this study also includes suggesting some implications on future basic direction of environment-friendly management. If this study would induce distributors to have more interest in distribution standardization and if logistics efficiency would be enhanced by the operation of packaging system considered of compatibility with pallets, this study would have academic significance and create practical values.

Estimation of Optimal Operation Conditions in Step Feed Processes Based on Stoichiometric Nitrogen Removal Reactions

  • Lee, Byung-Dae
    • 한국응용과학기술학회지
    • /
    • 제28권1호
    • /
    • pp.6-9
    • /
    • 2011
  • Step feed process was analyzed stoichiometrically for the optimal operation conditions in this study. In case of optimal operation conditions, minimum R (sludge recycling) value, r (internal recycling ratio) value, and n (influent allocation ratio) value for the step feed process to acquire the maximum TN removal efficiency were identified by theoretical analysis. Maximum TN removal efficiency, based on stoichiometric reaction, can be obtained by controlling n value for the step feed process.

기어 물림 상태의 타행 주행 저항을 이용한 엔진 운전 조건의 분석 (Analysis of Engine Operation Condition by Using Coastdown Test under Gear Engaged Condition)

  • 심범주;박경석;박준수;민병두
    • 한국자동차공학회논문집
    • /
    • 제20권6호
    • /
    • pp.61-66
    • /
    • 2012
  • Conventional method to transform vehicle driving condition to engine operation mode is to use vehicle road load under neutral gear and mechanical efficiency of drivetrain. But this method requires additional measurement of efficiency of drivetrain on a test rig. And this measurement is normally done at fixed speed and thus estimated accuracy of engine operation mode is not considered to be high enough. This study suggests new method to calculate engine operation mode for prescribed driving mode such as NEDC using vehicle coastdown test under gear engaged condition without measurement of mechanical efficiency of drivetrain. Coastdown test was done under neutral and gear engaged condition for comparison and also trial to extract mechanical loss of drivetrain was carried out. Calculated engine torque by conventional and newly suggested method was compared with actually measured torque of a vehicle on a chassis dynamometer during NEDC. Newly suggested method showed slightly higher accuracy of accumulated brake work during NEDC.

퍼지로직과 DEA를 이용한 RCC/RSC별 운영효율성 평가 (Evaluation of Operation Efficiency in the Korean RCC/RSC Using Fuzzy-Logic and DEA)

  • 장운재;금종수
    • 해양환경안전학회지
    • /
    • 제12권4호
    • /
    • pp.233-239
    • /
    • 2006
  • 본 연구는 우리나라 RCC/RSC의 효율성을 2개의 투입자료와 4개의 산출자료를 이용하여 DEA법을 이용하여 측정하였고, 정성적 자료는 전문가의 설문 및 면접결과로 평가하였다. 또한, 이러한 자료를 통합하기 위한 방법은 의사결정지원시스템인 퍼지로직을 적용하였고, 이 평가방법을 이용하여 RCC/RSC의 운영효율성의 우선순위를 평가하였다. 그 결과 목포, 제주, 부산, 통영, 인천, 여수, 동해, 울산, 포항, 속초, 태안, 완도, 군산RSC 순으로 효율성이 높은 것으로 나타났다.

  • PDF

A Novel Power-Efficient BS Operation Scheme for Green Heterogeneous Cellular Networks

  • Kim, Jun Yeop;Kim, Junsu;Kang, Chang Soon
    • 한국통신학회논문지
    • /
    • 제41권12호
    • /
    • pp.1721-1735
    • /
    • 2016
  • Power-efficient base station (BS) operation is one of the important issues in future green cellular networks. Previously well-known BS operation schemes, the cell zooming scheme and the cell wilting and blossoming scheme, require tight cooperation between cells in cellular networks. With the previous schemes, the non-cooperative BSs of a serving cell and neighboring cells could cause coverage holes between the cells, thereby seriously degrading the quality of service as well as the power saving efficiency of the cellular networks. In this paper, we propose a novel power-efficient BS operation scheme for green downlink heterogeneous cellular networks, in which the networks virtually adjust the coverage of a serving macrocell (SM) and neighboring macrocells (NMs) without adjusting the transmission power of the BSs when the SM is lightly loaded, and the networks turn off the BS of the SM when none of active users are associated with the SM. Simulation results show that our proposed scheme significantly improves the power saving efficiency without degrading the quality of service (e.g., system throughput) of a downlink heterogeneous LTE network and outperforms the previous schemes in terms of system throughput and power saving efficiency. In particular, with the proposed scheme, macrocells are able to operate independently without the cooperation of a SM and NMs for green heterogeneous cellular networks.