• Title/Summary/Keyword: operation efficiency

Search Result 5,505, Processing Time 0.032 seconds

High Efficiency Inverter System by Partial Resonant Method (부분공진기법에 의한 고효율 인버터 시스템)

  • 김영철;이현우
    • Proceedings of the KIPE Conference
    • /
    • 1998.11a
    • /
    • pp.39-43
    • /
    • 1998
  • A large number of soft switching topologies included a resonant circuit have been proposed. But these circuits increase number of switch in circuit and complicate sequence of switching operation. In this paper, the authors propose power conversion system, DC-AC inverter of high efficiency and high power factor with soft switching mode by partial resonant method. The switching devices in a proposed circuits are operated with soft switching by the partial resonant method, that is, PRS2MPC (Partial Resonant Soft Switching Mode Power Converter). The result is that the switching loss is very low and the efficiency of system is high. And the snubber condenser used in partial resonant circuit makes charging energy regenerated at input power source for resonant operation.

  • PDF

Analysis of Loss Compensation Efficiency Factor in the Uniform Price Market (단일가격시장에서 손실보상효율계수의 특성 분석)

  • Hahn, Tae-Kyung;Kim, Jin-Ho;Park, Jong-Keun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.5
    • /
    • pp.871-881
    • /
    • 2010
  • In the uniform price electricity market or bilateral electricity market, the energy transactions in which the network is not considered and ISO's system operation costs which ISO try to minimize are settled separately. In this paper, transmission loss, one of the ISO's system operation costs, was dealt. The conventional marginal loss allocation method gives economic signals but three aspects have to be considered; excessiveness, arbitrariness and cross-subsidy. In this paper, marginal loss compensation efficiency method was suggested which consider those aspects of the conventional marginal loss allocation method. Also the characteristics of the marginal loss compensation efficiency were analyzed in the appendixes. And simple 2-bus system and IEEE 14 bus system were used to explain these characteristics.

The Study on the Rules for Efficiency of Train Operation (열차운행효율화를 위한 운전관계 사규에 대한 연구)

  • Oh, Min-Seok;Kim, Ho-Soon;Jeong, Do-Won
    • Proceedings of the KSR Conference
    • /
    • 2010.06a
    • /
    • pp.823-829
    • /
    • 2010
  • Railway is facing a new era by the remarkable technology-intensive development of railways in the rolling stock and track, trains and infrastructure facilities. But the relevant provisions of the regulations for the various driving speed limit accept most of the past rules and it is desperately needed to realize the efficiency of the train operation. In addition, because the rules that drive too many treats of redundancy(the same information is duplicated in the other company policy provisions), they can cause confusion among employees, and also because of the contents of the detailed provisions dealing with almost same regulations, they can cause probable failure and big accident. In this study, the relevant provisions of the current rules are analyzed and overcome problems to improve efficiency and duplicated contents of relevant provisions to drive trains are merged. Also by reorganization of complex speed limits, we can understand easily when even the unusual situation and make a simple decision to prevent accidents. As a result, we can establish the system by doing subsequent actions quickly and accurately.

  • PDF

국내 폐탄광 광산배수 자연정화처리시설의 가동현황 연구

  • 지상우;고주인;김효범;강희태;김재욱;김선준
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.352-355
    • /
    • 2003
  • 27 passive systems in 21 mines constructed by The Coal Industry Promotion Board since 1996 were investigated to evaluate the treatment efficiency of systems and find problems in each system, which will eventually lead to the improvement or suggesting the alternative method of the passive treatment system. Problems in operation include overflow, leakage, inefficiency and unusablness. The efficiency of systems which has been evaluated by metal(Fe) removal rate and/or by acidity removal rate do not reflect the poor removal rate of S $O_4$$^{2-}$. Especially high concentration of S $O_4$$^{2-}$ and high COD in the beginning of the operation would decrease the bacteria activity due to the lack of the nutrition. To solve the problem of overflow the upflow-type SAPS is being considered.

  • PDF

Power Closed-loop Control of Switched Reluctance Generator for High Efficiency Operation

  • Li, Zhenguo;Gao, Dongdong;Ahn, Jin-Woo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.1 no.3
    • /
    • pp.397-403
    • /
    • 2012
  • This paper describes a control method of turn-on/off angles to improve the efficiency of the switched reluctance generator(SRG) with a power closed-loop control system, and the inner-loop of the system is current hysteresis control. The SRG control system is constituted by the PI power controller and the two-level current hysteresis controller. By measuring and analyzing the system losses of different reference powers, speeds and turn-on/off angles, selection strategy of optimal turn-on/off angles is discussed. The proposed method is simple, reliable, and easy to achieve.

Operation characteristics of fast pulse generator using a 2-stage magnetic switch (2단 자기스위치를 사용한 고속 펄스발생기의 동작 특성)

  • 김복권;권순걸;서기영;이현우
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.10
    • /
    • pp.139-147
    • /
    • 1996
  • In this study a two-stage fast pulse generaor using magnetic switches is proposed. The scheme consist of a switch, an inductor and two pairs of capacitor and saturable inductors, a linear transformer. The basic principle and the operation are described using a set of given parameters. The main issue of the magnetic pulse genration scheme is the system efficiency. This study focuses on the system efficiency improvement using magnetic switches. The voltage compression ratio, energy transfer with respect to core area are investigated. The output voltage and transferred energy as a function of input voltage are also included. Also, an analysis and experiments are performed to verify the porposed topology by implementing a 10[J] class experimental circuit. The efficiency of the transferred energy a tload side is 82%.

  • PDF

A High Efficiency and High Power Chopper Circuit QRAS using Soft Switching under Test Evaluation at 8kW

  • Tsuruta Yukinori;Kawamura Atsuo
    • Journal of Power Electronics
    • /
    • v.6 no.1
    • /
    • pp.1-7
    • /
    • 2006
  • This paper is a record of the study on a high efficiency and high power chopper based on the new soft switching method QRAS (Quasi~resonant Regenerating Active Snubber) designed for a Fuel Cell Electric Vehicle (FCEV). This power chopper is basically proposed for 25kHz soft switching. To confirm the practicality and effectiveness of the converter, the fabrication of a prototype-model using IGBTs was completed. Additionally, a 8kW rating test, a light load test, a current discontinuous mode test and a stable operation resonance test was completed. The circuit geometry, the basic operation, and the 8kW one-tenth-prototype test results are reported with a $97.5\%$ efficiency measurement.

Testing Harmonic Used Better than Aged in Expectation in Upper Tail(HUBAEUT) Class of Life Distributions Using Kernel Method

  • Abu-Youssef, S.E.;Al-nachawati, H.
    • International Journal of Reliability and Applications
    • /
    • v.7 no.2
    • /
    • pp.89-99
    • /
    • 2006
  • A new classes of life distribution, namely harmonic used better than aged in expectation in upper tail (HUBAEUT) is introduced. Testing exponentiality against this class is investigated using kernel method. The limiting null and nonnull distribution of the test statistics is normal and the null variance is calculated exactly. Selected critical values are tabulated for sample sizes of 5(1)40. Power of the test are estimated by simulation. the efficacies of the test statistics used for testing against HUBAEUT are calculated for som common alternatives and are compared to some other procedures. It is shown that proposed test is simple, has high relative efficiency and power for some commonly used alternatives. The set of real data are used as an examples to elucidate the use of the proposed test statistics for practical reliability.

  • PDF

Analysis of Performance Enhancement of a Microturbine by Water Injection (수분사를 통한 마이크로터빈 성능향상 해석)

  • Jeon, Mu-Sung;Lee, Jong-Jun;Kim, Tong-Seop
    • The KSFM Journal of Fluid Machinery
    • /
    • v.12 no.2
    • /
    • pp.46-51
    • /
    • 2009
  • Recently, microturbines have received attention as a small-scale distributed power generator. Since the exhaust gas carries all of the heat release, generating hot water is usual method of heat recovery from microturbine CHP (combined heat and power) systems. The power of microturbines decreases as ambient temperature increases. This study predicted micoturbine power boost by injecting hot water generated by heat recovery. Influence of injecting water at two different locations was examined. Water injection improves power, but efficiency depends much on the injection location. Injecting water at the compressor discharge shows a much higher efficiency than the combustor injection. However, the combustor injection may have as much available cogeneration heat as the dry operation, while the available heat in the compressor discharge injection is much smaller than the dry operation.

A Study on the Design of Wired and Wireless Communication System for Solar Panel Optimizer (태양광 패널 최적기의 유선 및 무선 통신 시스템 설계에 관한 연구)

  • Yang, Oh
    • Journal of the Semiconductor & Display Technology
    • /
    • v.18 no.2
    • /
    • pp.32-37
    • /
    • 2019
  • In this paper, we have designed a solar photovoltaic system to attach solar photovoltaic modules to each module and develop the best efficiency in each module. The efficiency of the designed solar panel optimizer was more than 99.27% and MPPT efficiency of 99.66%. In addition, the monitoring of power generation and abnormal operation phenomenon in each optimum period and tracking for failure location of specific photovoltaic module have improved the utilization rate of photovoltaic power generation. Wired and wireless communication methods has been proposed to monitor the power generation and operation status of the solar panel optimizer. For this purpose, the RS485 communication was used for wire communication and Zigbee communication was used for wireless communication to monitor the status of each module in real time. It is shown that communication redundancy can be achieved through the proposed method, and the possibility of commercialization is suggested.