• Title/Summary/Keyword: operating unit

Search Result 1,243, Processing Time 0.035 seconds

Comparison of Adverse Events due to Differences in NICU Nursing Expertise (NICU 간호 숙련성의 차이에 따른 위해 사건 비교)

  • Han, Young-Mi;Sung, Min-Jung;Park, Kyung-Hee;Byun, Shin-Yun
    • Neonatal Medicine
    • /
    • v.18 no.2
    • /
    • pp.345-352
    • /
    • 2011
  • Purpose: Nursing quality influences patient' outcomes in the neonatal intensive care unit (NICU). We compared differences in adverse events (AEs) by differences in the level of nursing experience at the NICU, developed guidelines to prevent AE, and then investigated the change in AE. Methods: AEs related to nursing were investigated from January 1, 2009 to December 31 2009 at the NICU of the newly established A hospital and B hospital that has been operating for 14 years. We also assessed the level of nursing experience. Guidelines to prevent nursing-related AEs were prepared at A hospital, and the change in the incidence of AE was investigated after 1 year. Results: Twenty nurses (80%) had <2 years experience at A hospital, whereas 13 nurses (65%) had 2 years or longer but less than 4 years experience at B hospital (P<0.001). The number of incidences of AE that occurred in 2009 in A hospital was higher (46) than that at B hospital (10). Intravenous (IV) injection-related incidents had the highest share in both hospitals: 24 incidents (52.2%) at hospital A and eight incidents (80%) at hospital B. After the guidelines were instituted in 2009, the number of nursing AEs decreased to 17, of which the number of IV incidents was the highest (6, 35%), athough its share decreased. Conclusion: Supervision and prevention guidelines should be in place to reduce nursing AEs, which would improve the quality of NICU service.

Numerical Study on the Supply and Exhaust Port Size and Fire Management Method in the Semi-transverse Ventilation System for Road Tunnel (도로터널 반횡류환기시스템에서 급배기 포트개도 및 화재시 운영방안에 관한 수치해석적 연구)

  • Ryu, Ji-Oh;Kim, Jin-Su;Rie, Dong-Ho
    • Fire Science and Engineering
    • /
    • v.30 no.2
    • /
    • pp.68-74
    • /
    • 2016
  • In semi-transverse ventilation system applied for road tunnel, adjustment of the port opening ratio is an essential part for uniform airflow rate per unit length over the entire tunnel. However, it has not been considered decently throughout the design process and operating of the tunnel. Therefore, in this study, we developed a program for the calculation of the opening size ratio of supply or exhaust port in transverse ventilation system and carried out the research to present a management plan for the port. In supply duct system, the opening size of the port had a tendency to increase and then decrease later when it gradually becomes closer toward the bulkhead at the beginning of the duct the minimum opening degree is to appeared as 56%. In the exhaust system, port size is the smallest at the beginning of duct as 15%, has shown a tendency to increase towards the bulk head. As results of estimating the air flow rate for 300 m intervals, the exhaust flow rate in the center of tunnel appeared to be extremely low as 8.1% and 12.5% when port size is constant and is adjusted supply type. Thus, even if the normal ventilation efficiency is declines, yet it is highly recommend adjusting the port size in order to obtain a uniform flow rate at fire accidents.

Building Energy Savings due to Incorporated Daylight-Glazing Systems (통합 채광시스템의 건물 냉난방 에너지 성능평가)

  • Kim, Jeong-Tai;Ahn, Hyun-Tae;Kim, Gon
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.6
    • /
    • pp.1-8
    • /
    • 2005
  • The quantity of light available for a space can be translated in term of the amount of energy savings through a process of a building energy simulation. To get significant energy savings in general illumination, the electric lighting system must be incorporated with a daylight - activated dimmer control. A prototype configuration of an once interior has been established and the integration between the building envelope and lighting and HVAC systems is evaluated based on computer modeling of a lighting control facility. First of all, an energy-efficient luminaire system is designed and the lighting analysis program, Lumen-Micro 2000 predicts the optimal layout of a conventional fluorescent lighting future to meet the designed lighting level and calculates unit power density, which translates the demanded met of electric lighting energy. A dimming control system integrated with the contribution of daylighting has been applied to the operating of the artificial lighting. Annual cooling load due to lighting and the projecting saving amount of cooling load due to daylighting under overcast diffuse sky m evaluated by computer software ENER-Win. In brief, the results from building energy simulation with measured daylight illumination levels and the performance of lighting control system indicate that daylighting can save over 70 percent of the required energy for general illumination in the perimeter zones through the year A 25[%] of electric energy for cooling and almost all off heating energy may be saved by dimming and turning off the luminaires in the perimeter zones.

Total Cost Analysis by Calling Port Reduction of Mega Containership - The Case of Domestic Shipping Company - (초대형 컨테이너선의 기항지 축소에 따른 총 비용 분석 - 국내 선사 사례를 중심으로 -)

  • Nam Ki-Chan;Song Yong-Seok;Kim Tae-Won
    • Journal of Navigation and Port Research
    • /
    • v.30 no.1 s.107
    • /
    • pp.53-59
    • /
    • 2006
  • Recently, 8,000TEU class containerships has started operating the shipping service and the mega-containership of over 10,000TEU is on planning. A unit cost in relation to shipping service is decreased by the bigger ship based on the economy of scale. Most of the previous studies have been performed and focused on the total operation cost from mega port to mega port. However, the purpose of this paper is to estimate economic efficiency of selected hub ports from point of view of total cost such as service cost(or operation cost), port charge and feeder cost, etc. First, the service-network of mega containerships is based on data of a domestic shipping company operated main line and economic analysis of individual scenarios on the cost and traffic when 10,000TEU mega containerships offer the services. The three scenarios presented in this paper set up the hub ports which are the port of Busan, Shanghai and Yokohama The results show that port of Busan is economically the most efficient one among others.

Plant-wide On-line Monitoring and Diagnosis Based on Hierarchical Decomposition and Principal Component Analysis (계층적 분해 방법과 PCA를 이용한 공장규모 실시간 감시 및 진단)

  • Cho Hyun-Woo;Han Chong-hun
    • Journal of the Korean Institute of Gas
    • /
    • v.1 no.1
    • /
    • pp.27-32
    • /
    • 1997
  • Continual monitoring of abnormal operating conditions i a key issue in maintaining high product quality and safe operation, since the undetected process abnormality may lead to the undesirable operations, finally producing low quality products, or breakdown of equipment. The statistical projection method recently highlighted has the advantage of easily building reference model with the historical measurement data in the statistically in-control state and not requiring any detailed mathematical model or knowledge-base of process. As the complexity of process increases, however, we have more measurement variables and recycle streams. This situation may not only result in the frequent occurrence of process Perturbation, but make it difficult to pinpoint trouble-making causes or at most assignable source unit due to the confusing candidates. Consequently, an ad hoc skill to monitor and diagnose in plat-wide scale is needed. In this paper, we propose a hierarchical plant-wide monitoring methodology based on hierarchical decomposition and principal component analysis for handling the complexity and interactions among process units. This have the effect of preventing special events in a specific sub-block from propagating to other sub-blocks or at least delaying the transfer of undesired state, and so make it possible to quickly detect and diagnose the process malfunctions. To prove the performance of the proposed methodology, we simulate the Tennessee Eastman benchmark process which is operated continuously with 41 measurement variables of five major units. Simulation results have shown that the proposed methodology offers a fast and reliable monitoring and diagnosis for a large scale chemical plant.

  • PDF

Requirements for Cerebrovascular Surgery in Comprehensive Stroke Centers in South Korea

  • Kim, Tackeun;Oh, Chang Wan;Park, Hyeon Seon;Lee, Kunsei;Lee, Won Kyung;Lee, Heeyoung
    • Journal of Korean Neurosurgical Society
    • /
    • v.61 no.4
    • /
    • pp.478-484
    • /
    • 2018
  • Objective : Cerebrovascular disease (CVD) was the third most common cause of death in South Korea in 2014. Evidence from abroad suggests that comprehensive stroke centers play an important role in improving the mortality rate of stroke. However, surgical treatment for CVD is currently slightly neglected by national policy, and there is still regional imbalance in this regard. For this reason, we conducted a survey on the necessity of, and the requirements for, establishing regional comprehensive cerebrovascular surgery centers (CCVSCs). Methods : This investigation was performed using the questionnaire survey method. The questionnaire was consisted with two sections. The first concerned the respondent's opinion regarding the current status of demand and the regional imbalance of cerebrovascular surgery in South Korea. The second section asked about the requirements for establishing regional CCVSCs. We sent the questionnaire to 100 board members of the Korean Society of Cerebrovascular Surgeons. Results : Most experts agreed that cerebrovascular surgery patients were concentrated in large hospitals in the capital area, and 83.6% of respondents agreed that it was necessary to alleviate the regional imbalance of cerebrovascular surgery. With regards to personnel, over 90% of respondents answered that at least two neuro-vascular surgeons and two neuro-interventionists are necessary to establish a CCVSC. Regarding facilities, almost all respondents stated that each CCVSC would require a neuro-intensive care unit and hybrid operating room. The survey asked the respondents about 13 specific neurovascular surgical procedures and whether they were necessary for a regional CCVSC. In the questions about the necessity of cerebrovascular surgical equipment, all seven pieces of equipment were considered essential by all respondents. A further five pieces of equipment were considered necessary on site: computed tomographic angiography, magnetic resonance angiography, conventional angiography, surgical microscope, and surgical navigation. Our results may provide a basis for future policy regarding treatment of cerebrovascular disease, including surgery. Conclusion : Raising the comprehensiveness of treatment at a regional level would lower the national disease burden. Policies should be drafted regarding comprehensive treatment including surgery for cerebrovascular disease, and related support plans should be implemented.

Development of Autonomous Bio-Mimetic Ornamental Aquarium Fish Robotic (생체 모방형의 아쿠아리움 관상어 로봇 개발)

  • Shin, Kyoo Jae
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.4 no.5
    • /
    • pp.219-224
    • /
    • 2015
  • In this paper, the designed fish robots DOMI ver1.0 is researched and development for aquarium underwater robot. The presented fish robot consists of the head, 1'st stage body, 2nd stage body and tail, which is connected two point driving joints. The model of the robot fish is analysis to maximize the momentum of the robot fish and the body of the robot is designed through the analysis of the biological fish swimming. Also, Lighthill was applied to the kinematics analysis of robot fish swimming algorithms, we are applied to the approximate method of the streamer model that utilizes techniques mimic the biological fish. The swimming robot has two operating mode such as manual and autonomous operation modes. In manual mode the fish robot is operated to using the RF transceiver, and in autonomous mode the robot is controlled by microprocessor board that is consist PSD sensor for the object recognition and avoidance. In order to the submerged and emerged, the robot has the bladder device in a head portion. The robot gravity center weight is transferred to a one-axis sliding and it is possible to the submerged and emerged of DOMI robot by the breath unit. It was verified by the performance test of this design robot DOMI ver1.0. It was confirmed that excellent performance, such as driving force, durability and water resistance through the underwater field test.

Design and Implementation of Unified Index for Moving Objects Databases (이동체 데이타베이스를 위한 통합 색인의 설계 및 구현)

  • Park Jae-Kwan;An Kyung-Hwan;Jung Ji-Won;Hong Bong-Hee
    • Journal of KIISE:Databases
    • /
    • v.33 no.3
    • /
    • pp.271-281
    • /
    • 2006
  • Recently the need for Location-Based Service (LBS) has increased due to the development and widespread use of the mobile devices (e.g., PDAs, cellular phones, labtop computers, GPS, and RFID etc). The core technology of LBS is a moving-objects database that stores and manages the positions of moving objects. To search for information quickly, the database needs to contain an index that supports both real-time position tracking and management of large numbers of updates. As a result, the index requires a structure operating in the main memory for real-time processing and requires a technique to migrate part of the index from the main memory to disk storage (or from disk storage to the main memory) to manage large volumes of data. To satisfy these requirements, this paper suggests a unified index scheme unifying the main memory and the disk as well as migration policies for migrating part of the index from the memory to the disk during a restriction in memory space. Migration policy determines a group of nodes, called the migration subtree, and migrates the group as a unit to reduce disk I/O. This method takes advantage of bulk operations and dynamic clustering. The unified index is created by applying various migration policies. This paper measures and compares the performance of the migration policies using experimental evaluation.

High Resolution InSAR Phase Simulation using DSM in Urban Areas (도심지역 DSM을 이용한 고해상도 InSAR 위상 시뮬레이션)

  • Yoon, Geun-Won;Kim, Sang-Wan;Lee, Yong-Woong;Lee, Dong-Cheon;Won, Joong-Sun
    • Korean Journal of Remote Sensing
    • /
    • v.27 no.2
    • /
    • pp.181-190
    • /
    • 2011
  • Since the radar satellite missions such as TerraSAR-X and COSMO-SkyMed were launched in 2007, the spatial resolution of spaceborne SAR(Synthetic Aperture Radar) images reaches about 1 meter at spotlight mode. In 2011, the first Korean SAR satellite, KOMPSAT-5, will be launched, operating at X-band with the highest spatial resolution of 1 m as well. The improved spatial resolution of state-of-the-art SAR sensor suggests expanding InSAR(Interferometric SAR) analysis in urban monitoring. By the way, the shadow and layover phenomena are more prominent in urban areas due to building structure because of inherent side-looking geometry of SAR system. Up to date the most conventional algorithms do not consider the return signals at the frontage of building during InSAR phase and SAR intensity simulation. In this study the new algorithm introducing multi-scattering in layover region is proposed for phase and intensity simulation, which is utilized a precise LIDAR DSM(Digital Surface Model) in urban areas. The InSAR phases simulated by the proposed method are compared with TerraSAR-X spotlight data. As a result, both InSAR phases are well matched, even in layover areas. This study will be applied to urban monitoring using high resolution SAR data, in terms of change detection and displacement monitoring at the scale of building unit.

Optimization of Electro-UV-Ultrasonic Complex Process for E. coli Disinfection using Box-Behnken Experiment (Box-Behnken법을 이용한 E. coli 소독에서 전기-UV-초음파 복합 공정의 최적화)

  • Kim, Dong-Seog;Park, Young-Seek
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.33 no.3
    • /
    • pp.149-156
    • /
    • 2011
  • This experimental design and response surface methodology (RSM) have been applied to the investigation of the electro-UV-ultrasonic complex process for the disinfection of E. coli in the water. The disinfection reactions of electro-UV-ultrasonic process were mathematically described as a function of parameters power of electrolysis ($X_1$), UV ($X_2$), and ultrasonic process ($X_3$) being modeled by use of the Box-Behnken technique, which was used for fitting 2nd order response surface model. The application of RSM yielded the following regression equation, which is empirical relationship between the residual E. coli number (Ln CFU) in water and test variables in coded unit: residual E. coli number (Ln CFU) = 23.69 - 3.75 Electrolysis - 0.67 UV - 0.26 Ultrasonic - 0.16 Electrolysis UV + 0.05 Electrolysis Ultrasonic + 0.27 $Electrolysis^2$ + 0.14 $UV^2$ - 0.01 $Ultrasonic^2$). The model predictions agreed well with the experimentally observed result ($R^2$ = 0.983). Graphical 2D contour and 3D response surface plots were used to locate the optimum range. The estimated ridge of maximum response and optimal conditions for residual E. coli number (Ln CFU) using 'numerical optimization' of Design-Expert software were 1.47 Ln CFU/L and 6.94 W of electrolysis, 6.72 W of UV and 14.23 W of ultrasonic process. This study clearly showed that response surface methodology was one of the suitable methods to optimize the operating conditions and minimize the residual E. coli number of the complex disinfection.