• Title/Summary/Keyword: operating unit

Search Result 1,243, Processing Time 0.158 seconds

Main Function, Management Difficulties and Activating Conditions of the Cooperative Child Care Sharing Center Based on Field Cases (현장 사례로 본 공동육아나눔터의 주요 기능과 운영상 문제 및 활성화 조건)

  • Lee, Seung-mie;Kim, Seon-mi
    • Journal of Family Resource Management and Policy Review
    • /
    • v.26 no.1
    • /
    • pp.59-73
    • /
    • 2022
  • This qualitative study focused on the activation of cooperative child care sharing centers'. Eight centers nationwide were selected as example cases in accordance with region (large city, small and medium-sized city, county unit), opening time, operating institution, location, full-time care for dual-income children, and participation in the 2020 care community pilot project. Co-researchers visited each center together to observe the site and conducted in-depth interviews with the head of the center or dedicated staff using semi-structured questionnaires. Interview data were analyzed using triangle verification and transcribed : the data were then grouped into 12 categories and 34 subcategories. From this, the following three topics were derived: the main functions, operational difficulties, and activation conditions. In conclusion, four suggestions are made: 1. proper relationship with the Family center, the cooperative childcare sharing center, and the local care communities 2. activation plan through "solution of operational difficulties" 3. "extension" of the cooperative child care sharing center 4. the role of the Ministry of Gender Equality and Family, the Korea Institute for Healthy Family, local governments, and Family Centers.

Prediction of pathogen positive-culture results in acute poisoning patients with suspected aspiration (흡인이 의심되는 급성 중독환자에서 병원균 양성 배양 결과의 예측)

  • Baek Sungha;Park Sungwook
    • Journal of The Korean Society of Clinical Toxicology
    • /
    • v.20 no.2
    • /
    • pp.75-81
    • /
    • 2022
  • Purpose: This study sought to compare the characteristics of patients with pathogen-positive and negative cultures, and to investigate factors predicting pathogen-positive culture results in patients of acute poisoning with suspected aspiration. Methods: Consecutive patients with acute poisoning admitted to an intensive care unit between January 2016 and December 2018 were retrospectively studied. Respiratory specimens were collected from the enrolled patients at the time of the suspected aspiration. We compared the characteristics of patients with pathogen-positive and negative culture results and analyzed the causative pathogens. Results: Among the 526 patients, 325 showed no clinical features that could be attributed to aspiration, and 201 patients had clinical features suggestive of aspiration. Of these, 113 patients had pathogen-positive culture, 61 were negative, and the specimens of 27 patients contained poor-quality sputum. In univariate analysis, patients with a positive culture showed a longer time to culture from ingestion (p=0.01), faster heart rate (p=0.01), and higher partial pressure of arterial oxygen to the fraction of inspired oxygen (PaO2/FiO2) (p=0.02) than patients with negative culture. Multivariate analysis demonstrated that PaO2/FiO2 (adjusted odd ratio, 1.005; 95% confidence interval [CI], 1.002-1.008; p=0.005) was a significant risk factor for pathogen-positive culture. The area under the receiver operating characteristic curve of PaO2/FiO2 was 0.591 (95% CI, 0.510-0.669, p=0.05). Gram-negative pathogens (GNPs) were predominant and at least one GNP was observed in 84 (73.3%) patients among those with pathogen positive culture. Conclusion: We failed to find any clinical factors associated with positive culture results. Antibiotics that cover GNPs could be considered when deciding the initial antibiotic regimen at the time of suspected aspiration.

A Study on the Optimal Combination of Berth and Crane in Container Terminal (컨테이너터미널 사용자비용을 최소로 하는 선석과 크레인의 최적구성에 관한 연구)

  • Yun, Y.C.;Moon, S.H.
    • Journal of Korean Port Research
    • /
    • v.9 no.2
    • /
    • pp.39-49
    • /
    • 1995
  • Recently, the traffic volume has been greatly increased partly because of high growth rate of domestic and world economy, and partly because of increased transhipment demand resulting from the destruction of Kobe port by earthqwake early this year. So, container facilities in Pusan Port are under serious congestion. The congestion costs in connection with container traffic in Pusan Port is estimated to be 29.3 billion won in 1994. In 1995 the situation is still worsening. PECT has continued to grow annually by 35% in cargo handling exceeding more than 31% of the total container volumes handled in Korea. The BOR of container berths in PECT in 1994 is 75% reflecting extreme congestion in container traffic. The reason for such serious congestion in PECT is the shortage of container handling facilities in comparison with ever-increasing cargo traffic. In order to solve the provisional problem, the shortage of handling capacity, a model developed to optimize the operation of PECT is described and demonstrated. The model minimizes total port costs, including the costs of dock labour, facilities and equipment, ship, containers, and cargo. The object of this study is, through the model results, mainly to determine the optimal combination of berths and cranes under various circumstances and to show that total costs per ship or unit of cargo served can be reduced by increasing the number of cranes per berth and berth utilization above present levels. Eventually, the results obtained with this model in PECT suggest that increase to 3 in the number of cranes per existing berth could reduce the need for major investments in berths and even reduce operating costs.

  • PDF

Scenario-based Future Infantry Brigade Information Distribution Capability Analysis (시나리오 기반의 미래 보병여단 정보유통능력 분석 연구)

  • Junseob Kim;Sangjun Park;Yiju You;Yongchul Kim
    • Convergence Security Journal
    • /
    • v.23 no.1
    • /
    • pp.139-145
    • /
    • 2023
  • The ROK Army is promoting cutting-edge, future-oriented military development such as a mobile, intelligent, and hyper-connected Army TIGER system. The future infantry brigade plans to increase mobility with squad-level tactical vehicles to enable combat in multi-domain operations and to deploy various weapon systems such as surveillance and reconnaissance drones. In addition, it will be developed into an intelligent unit that transmits and receives data collected through the weapon system through a hyper-connected network. Accordingly, the future infantry brigade will transmit and receive more data. However, the Army's tactical information communication system has limitations in operating as a tactical communication system for future units, such as low transmission speed and bandwidth and restrictions on communication support. Therefore, in this paper, the information distribution capability of the future infantry brigade is presented through the offensive operation scenario and M&S.

Design and Analysis of Composite Reflector of High Stable Deployable Antenna for Satellite (위성용 전개형 고안정 반사판 안테나 복합재 주반사판 설계 및 해석)

  • Dong-Geon Kim;Kyung-Rae Koo;Hyun-Guk Kim;Sung-Chan Song;Seong-Cheol Kwon;Jae-Hyuk Lim;Young-Bae Kim
    • Composites Research
    • /
    • v.36 no.3
    • /
    • pp.230-240
    • /
    • 2023
  • The deployable reflector antenna consists of 24 unit main reflectors, and is mounted on a launch vehicle in a folded state. This satellite reaches the operating orbit and the antenna of satellite is deployed, and performs a mission. The deployable reflector antenna has the advantage of reduce the storage volume of payload of launch vehicle, allowing large space structures to be mounted in the limited storage space of the launch vehicle. In this paper, structural analysis was performed on the main reflector constituting the deployable reflector antenna, and through this, the initial conceptual design was performed. Lightweight composite main reflector was designed by applying a carbon fiber composite and honeycomb core. The laminate pattern and shape were selected as design variables and a design that satisfies the operation conditions was derived. Then, the performance of the lightweight composite reflector antenna was analyzed by performing detailed structural analysis on modal analysis, quasi-static, thermal gradient, and dynamic behavior.

A study on the implementation of door control unit for railway trains operable at low and high platforms

  • Young-Seok Cho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.28 no.7
    • /
    • pp.1-9
    • /
    • 2023
  • Currently, as the demand for stops in the urban increases resulting from an increase in the supply of express trains, the development of trains capable of operating both high-floor platforms in the urban and low-floor platforms in the suburbs is required. In this paper, we studied the design and fabrication of a controller for train doors that consists of low and high steps as a plug-in type door mechanism and thus can be used on low and high platforms. This DCU H/W was designed and implemented using 32 bit MCU to control 4 motors, 33 digital inputs and 16 digital outputs. In addition, based on the software life cycle of EN50128, 2 items of operation requirements and 12 items of control requirements were derived, and then they were designed and implemented as operation SW. The implemented SW was tested for each requirement. As a result, we performed tests on 13 items that could be tested in the mock-up out of 14 total requirement items and showed that the requirements were satisfied.

An Integrated Flood Simulation System for Upstream and Downstream of the Agricultural Reservoir Watershed (농촌 유역 저수지 상·하류 통합 홍수 모의 시스템 구축 및 적용)

  • Kwak, Jihye;Kim, Jihye;Lee, Hyunji;Lee, Junhyuk;Cho, Jaepil;Kang, Moon Seong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.65 no.1
    • /
    • pp.41-49
    • /
    • 2023
  • To utilize the hydraulic and hydrological models when simulating floods in agricultural watersheds, it is necessary to consider agricultural reservoirs, farmland, and farmland drainage system, which are characteristics of agricultural watersheds. However, most of them are developed individually by different researchers, also, each model has a different simulation scope, so it is hard to use them integrally. As a result, there is a need to link each hydraulic and hydrological model. Therefore, this study established an integrated flood simulation system for the comprehensive flood simulation of agricultural reservoir watersheds. The system can be applied easily to various watersheds because historical weather data and the SSP (Shared Socio-economic Pathways) climate change scenario database of ninety weather stations were built-in. Individual hydraulic and hydrological models were coded and coupled through Python. The system consists of multiplicative random cascade model, Clark unit hydrograph model, frequency analysis model, HEC-5 (Hydrologic Engineering Center-5), HEC-RAS (Hydrologic Engineering Center-River Analysis System), and farmland drainage simulation model. In the case of external models with limitations in conceptualization, such as HEC-5 and HEC-RAS, the python interpreter approaches the operating system and gives commands to run the models. All models except two are built based on the logical concept.

Characterization of Fuel Cell Stack Using Hydrocarbon Polymer-Silica Composite Membranes (탄화수소계 고분자-실리카 복합막이 적용된 연료전지 스택 성능평가)

  • Hyun Woo Kang;Doo Sung Hwang;Chi Hoon Park;Young Moo Lee
    • Membrane Journal
    • /
    • v.33 no.3
    • /
    • pp.127-136
    • /
    • 2023
  • In this study, the electrochemical performance of a 5-layer fuel cell stack using silica composite membranes as polymer electrolyte membranes was evaluated. It was observed that the flow rate of the fuel gases plays a crucial role in stack performance, particularly being mainly dependent on the flow rate of hydrogen. Increasing the flow rate of oxygen resulted in negligible changes in performance, whereas an increase in the flow rate of hydrogen demonstrated performance improvements. However, this led to an imbalance in the ratio of hydrogen to oxygen flow rates, causing significant degradation in stack performance and durability. A decline in stack performance was also observed over time due to the degradation of stack components. This phenomenon was consistently observed in individual unit cells. Based on these findings, it was emphasized that, in addition to optimizing the performance of each component during stack operation, it is important to optimize design and operating conditions for uniform flow rate control. Lastly, the developed silica composite membrane was assessed to have sufficient performance for application in actual fuel cell systems, exhibiting a performance of over 25 W based on maximum power.

One year of treating patients with open fractures of the lower extremity in a new military trauma center in Korea: a case series

  • Ji Wool Ko;Giho Moon;Jin Geun Kwon;Kyoung Eun Kim;Hankaram Jeon;Kyungwon Lee
    • Journal of Trauma and Injury
    • /
    • v.36 no.4
    • /
    • pp.376-384
    • /
    • 2023
  • Purpose: The Armed Forces Trauma Center of Korea was established in April 2022. This study was conducted to report our 1-year experience of treating soldiers with open fractures of the lower extremity. Methods: In this case series, we reviewed the medical records of 51 Korean soldiers with open fractures of the lower extremity between April 2022 and March 2023 at a trauma center. We analyzed patients with Gustilo-Anderson type II and III fractures and reported the duration of transportation, injury mechanisms, injured sites, and associated injuries. We also presented laboratory findings, surgery types, intensive care unit stays, hospital stays, rehabilitation results, and reasons for psychiatric consultation. Additionally, we described patients' mode of transport. Results: This study enrolled nine male patients who were between 21 and 26 years old. Six patients had type II and three had type III fractures. Transport from the accident scene to the emergency room ranged from 75 to 455 minutes, and from the emergency room to the operating room ranged from 35 to 200 minutes. Injury mechanisms included gunshot wounds, landmine explosions, grenade explosions, and entrapment by ship mooring ropes. One case had serious associated injuries (inhalation burn, open facial bone fractures, and hemopneumothorax). No cases with serious blood loss or coagulopathies were found, but most cases had a significant elevation of creatinine kinase. Two patients underwent vascular reconstruction, whereas four patients received flap surgery. After rehabilitation, six patients could walk, one patient could move their joints actively, and two patients performed active assistive movement. Eight patients were referred to the psychiatry department due to suicidal attempts and posttraumatic stress disorder. Conclusions: This study provides insights into how to improve treatment for patients with military trauma, as well as medical services such as the transport system, by revising treatment protocols and systematizing treatment.

Development of maintenance concept and procedures for KASS (KASS 유지보수 정의 및 절차 개발)

  • Minhyuk Son;Youngsun Yun;ByungSeok Lee
    • Journal of Advanced Navigation Technology
    • /
    • v.26 no.6
    • /
    • pp.373-379
    • /
    • 2022
  • KASS (korea augmentation satellite system) is an SBAS (satellite based augmentation system) that must ensure the performance of aviation service in accordance with the International Civil Aviation Organization's SARPs (standards and recommended practices) Annex 10 - Aeronautical Telecommunications. In order to guarantee the target service performance, the operating system must be operated, maintained and managed stably, and a maintenance system must be established for this purpose. From the maintenance point of view, the KASS subsystems were developed to consist of replacement units, and the maintenance organization and procedures to manage those subsystems and units were defined. In addition, the maintenance task for each the replacement unit was developed to ensure the availability performance required for the successful KASS operation, and the developed tasks were verified to sufficiently cover the activities to maintain the previously defined replacement units. The maintenance tasks developed through this study will be continuously verified in the actual operation preparation process prior to the full-scale provision of aviation services in the end of 2023, and will be updated accordingly.