• Title/Summary/Keyword: operating room

Search Result 769, Processing Time 0.025 seconds

Sliding Wear Properties of Graphite as Sealing Materials for Cut off Hot Gas (고온차단 기밀용 그라파이트의 고온 미끄럼마모 특성 평가)

  • Kim, YeonWook;Kim, JaeHoon;Yang, HoYeong;Park, SungHan;Lee, HwanKyu;Kim, BumKeun;Lee, SeungBum;Kwak, JaeSu
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.37 no.11
    • /
    • pp.1349-1354
    • /
    • 2013
  • Sealing structure to prevent flowing hot gas into the driving device, located between the driving shaft and the liner of On-Off valve for controlling the hot gas flow path was studied. Wear occurs due to the constant movement of the driving shaft controlled by actuator on graphite as the sealing material. In this paper, the dynamic wear behavior in high temperature of graphite(HK-6) to be used as sealing material was evaluated. Reciprocating wear test was carried out for the graphite(HK-6) to the relative motion between shaft materials(W-25Re). The results of friction coefficient and specific wear rate according to contact load, sliding speed at room temperature and $485^{\circ}C$ considering the actual operating environment were evaluated. Through the SEM analysis of the worn surface, third body as lubricant films were observed and lubricant effect of third body was considered.

The Study of Permeation Characteristics for Pure Carbon Dioxide and Methane, and Gas Mixture in Cellulosic Membrane (셀룰로오스 분리막을 통한 순수 이산화탄소 메탄 및 혼합기체의 투과 특성 연구)

  • Kim, Hyun Joon;Kim, Hong Il;Kang, Yong Soo;Hong, Suk In
    • Applied Chemistry for Engineering
    • /
    • v.7 no.4
    • /
    • pp.605-613
    • /
    • 1996
  • The permeation characteristics were investigated for pure carbon dioxide and methane through asymmetric cellulose acetate(CA) membrane, composite cellulose acetate membrane and asymmetric cellulose triacetate(CTA) membrane. In particular, the effect of operating pressure on the permeation performance was examined. And the permeation behavior for a mixture of carbon dioxide and methane ($CO_2/CH_4=57.6/42.4$) was also investigated and compared to the characteristics obtained from pure gases. The experiments were run at the range of partial pressure from 25 to 125 psig, and room temperature. The permeation behaviors of the CA composite and CTA membrane were similiar to those of the CA membrane. The permeation rates of pure carbon dioxide for CA, CA composite and CTA membrane were increased slightly with an increase in upstream partial pressure, while in the case of pure methane they were independent of upstream partial pressure. For a binary mixture of carbon dioxide and methane, abnormal permeation behaviors were observed due to the plasticization of carbon dioxide and the competition effect of each gas. The separation factor and permeation rate for CTA membrane were found to be higher than those for CA membrane, but the mechanical strength of CTA membrane was very poor. And the permeation rate for CA composite membrane was higher than that for CA membrane. Consequently, it can be said that the CA composite membrane is a strong candidate for the separation of $CH_4$ and $CO_2$.

  • PDF

Generation of Femtosecond Pulses in a Passively Mode-Locked 100 MHz Cr4+:YAG Laser (수동 모드 잠금된 100 MHz Cr4+:YAG 레이저에서의 펨토초 펄스 발생)

  • Cho, Won-Bae;Rotermund Fabian;Kim, Jong-Doo;Jeon, Min-Yong;Suh, Ho-Suhng
    • Korean Journal of Optics and Photonics
    • /
    • v.16 no.6
    • /
    • pp.535-541
    • /
    • 2005
  • We report on the development of a passively mode-locked near-infrared femtosecond laser with Cr:YAG crystal that operates near room temperature. The laser wavelength could easily be tuned by using only the internal prism pair over 110 nm from 1400 nm to 1510 nm in cw and over about 30 nm in mode-locked operation, respectively Maximum cw output powers of 810 mW were obtained with $1.5 \%$ output coupler for absorbed pump powers of 7.6 W. For compensation of the internal group velocity dispersion, an IR graded prism pair was used. The Cr:YAG laser delivered nearly Fourier-transform limited pulses with a pulse duration as short as 64 fs at 100 MHz repetition rate. In the mode-locked regime, the laser was operating at 1510 nm with a spectral bandwidth of 44 nm. In order to avoid unstable mode-locking and power instabilities, self-built tubes were inserted into the beam path in the resonator and purged with N2 gas. Finally, output powers of the Cr:YAG laser were optimized to 250 mW fer long time stable mode-locked operation.

An Implementation of Temperature Independent Bias Scheme in Voltage Detector (온도에 무관한 전압검출기의 바이어스 구현)

  • Moon, Jong-Kyu;Kim, Duk-Gyoo
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.39 no.6
    • /
    • pp.34-42
    • /
    • 2002
  • In this paper, we propose a temperature independent the detective voltage source in voltage detector. The value of a detective voltage source is designed to become m times of silicon bandgap voltage at zero absolute temperature. By properly choosing the temperature coefficient of diode, the temperature coefficient of a concave voltage nonlinearities generated by the ${\Delta}V_{BE}$ section of diode between base and emitter of transistors with a different area can be summed with convex nonlinearities the $V_{BE}$ voltage to achieve the near zero temperature coefficient of the detective voltage source. We designed that the value of a detective voltage can be varied by ${\Delta}V_{BE}$, the $V_{BE}$multiplier circuit and resistor. In order to verify the performance of a proposed detective voltage source, we manufactured the voltage detector IC for 1.9V which is fabricated in $6{\mu}m$ Bipolar technology and measured the operating characteristics, the temperature coefficient of a detective voltage. To reduce the deviation of a detective voltage in the IC process step, we introduced a trimming technology, ion implantation and an isotropic etching. In manufactured IC, the detective voltage source could achieve the stable temperature coefficient of 29ppm/$^{\circ}C$ over the temperature range of -30$^{\circ}C$ to 70$^{\circ}C$. The current consumption of a voltage detector constituted by the proposed detective voltage source is $10{\mu}A$ from 1.9V-supply voltage at room temperature.

LED for plant growth regulators for the study of Light on the device (식물 생장 조절을 위한 LED 광처리 장치에 대한 연구)

  • Bang, Gul-Won;Kim, Yong-Ho
    • Journal of Digital Convergence
    • /
    • v.10 no.7
    • /
    • pp.267-272
    • /
    • 2012
  • Overcoming harsh light environment, as well as increased growth of crops even in high-quality production can play an important role when using the LED light system of photosynthetic products will be able to effectively reduce consumption. In this study, low efficiency of farm greenhouses, growing annual reduction in income due to rising operating costs and increase crop growth by inducing the proper planting environment Factory-type raise farmers' income and at the same time will contribute to the increase of Light device using LED Supplemental through photosynthesis, promote and improve product quality, plant growth regulators are considered possible for them to develop more efficient LED devices and LED Optical processing devices of Light leaf lettuce grown using normal fluorescent or incandescent bulbs grown in the results than the growth can see that the speed improvements. Usually shipped from seedling to harvest leaf lettuce from 25 to 30, whereas optical processing device be required red light (wavelength: 645nm) using a leaf of lettuce grown enough to be harvested after seven days increased the rate of growth. In addition, red light (wavelength: 645nm) and blue light (wavelength: 470nm) emitting at the same time, room, and grown for 5 days to harvest the growth rate was fast enough.

Determination of HONO Concentration and Investigation on Its Formation Mechanism Using a Continuous Measurement System in Indoor Environment of an Apartment (아파트 실내 환경에서 실시간 측정시스템을 활용한 HONO 농도 측정 및 생성기작 연구)

  • Park, Seung-Shik;Hong, Jin-H.;Lee, Jai-H.;Kim, Young-J.;Cho, Sung-Y.;Kim, Seung-J.
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.16-29
    • /
    • 2008
  • Nitrous acid (HONO) can be produced by heterogenous reactions of nitrogen dioxide on surface materials and direct emission from combustion sources. However, a little is known of indoor HONO levels or the relationship between residential HONO, NO, and $NO_2$ concentrations in occupied houses. Therefore, we measured simultaneously NO, $NO_2$, and HONO concentrations in living room of an apartment using continuous analyzers to study the production of HONO (June $22{\sim}30$, 2006). The 4-min average concentrations of indoor NO, $NO_2$, and HONO were 4.3 (range: $0.4{\sim}214.3$), 10.3 ($2.0{\sim}87.3$), and 1.8 ppb ($0.3{\sim}7.7$), respectively. Peak levels of HONO up to 7.7 ppb and 24-hr averages as high as 1.7 ppb were measured. In agreement with previous studies, indoor HONO concentrations increased during operation of an unvented gas range. Examination of the observed kinetics suggests that the secondary production of indoor HONO, possibly as a result of heterogeneous reactions involving $NO_2$ and $H_2O$ is associated with $[NO_2]^2[H_2O]\;(r^2=0.88)$ rather than with $[NO][NO_2][H_2O]\;(r^2=0.75)$. Three combustion experiments at nighttime were also carried out to investigate the effects of vented combustion on the HONO, NO, and $NO_2$ concentrations. It was found to release HONO for $10{\sim}15$ minutes after NO and $NO_2$ source was turned off, and peak values were finally attained. Compared to unvented combustion, peak $NO_2$ and HONO concentrations were 3.2 and 2.0 times lower at weak vented combustion (air flow: $340\;m^3/hr$) and 4.9 and 2.4 times lower at strong vented combustion (air flow: $540\;m^3/hr$), respectively, emphasizing importance of operating ventilation hood fan during combustion to improve indoor air quality.

A study on the standard of effective fire facilities for the Atrium (아트리움 공간의 효과적인 방화설비 기준연구)

  • Choi, Don-Mook;Kim, Jae-Woon;Min, Se-Hong
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.6 no.1
    • /
    • pp.49-66
    • /
    • 2005
  • The purpose of this study is to present reference data to be considered in designing fur the fire safety of atrium buildings. This study deals with the characteristics of atrium buildings in the fire safety aspect, analysis of fire examples and foreign fire codes of atrium space. And con-crete factors to be consigning fur the fire facilities of atrium buildings are presented. Recently many atrium spaces have been built in Korea. They provide new experience of space with resident and pedestrians. However, because of the lack of knowledge in design principle and disaster prevention, large loss of lives is expected in an emergency situation. cion. Therefore safety ensuring from the case is urgently needed. The following is the summary on the standard of effective fire facilities for the atrium. 1. The smoke control. inside atrium must use the machine ventilation in the atrium. 2. It is desirable to divide the section between atrium and nearby living room by anti-smoke screen in order to prevent damage by smoke when fire break out. 3. It is desirable to instill an excellent fire detector like infrared light detector as a replacement of old one. 4. It is desirable to transfer from closed operating sprinkler to fire-cycle sprinkler equipment or ablative sprinkler when the height is lower than 20m.

  • PDF

CdZnTe Detector for Computed Tomography based on Weighting Potential (가중 퍼텐셜에 기초한 CT용 CdZnTe 소자 설계)

  • Lim, Hyunjong;Park, Chansun;Kim, Jungsu;Kim, Jungmin;Choi, Jonghak;Kim, KiHyun
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.35-42
    • /
    • 2016
  • Room-temperature operating CdZnTe(CZT) material is an innovative radiation detector which could reduce the patient dose to one-tenth level of conventional CT (Computed Tomography) and mammography system. The pixel and pixel pitch in the imaging device determine the conversion efficiency of incident X-or gamma-ray and the cross-talk of signal, that is, image quality of detector system. The weighting potential is the virtual potential determined by the position and geometry of electrode. The weighting potential obtained by computer-based simulation in solving Poisson equation with proper boundaries condition. The pixel was optimized by considering the CIE (charge induced efficiency) and the signal cross-talk in CT detector system. The pixel pitch was 1-mm and the detector thickness was 2-mm in the simulation. The optimized pixel size and inter-pixel distance for maximizing the CIE and minimizing the signal cross-talk is about $750{\mu}m$ and $125{\mu}m$, respectively.

Evaluation of Fatigue Crack Propagation Behavior of Nickel-based Powder Metallurgy Superalloy for Aircraft at Elevated Temperature (항공기 터빈 디스크용 니켈기 초내열 분말야금 합금의 고온 피로균열진전 거동 비교 평가)

  • Yoon, Dong Hyun;Na, Seong Hyeon;Kim, Jae Hoon;Kim, Hongkyu;Kim, Donghoon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.41 no.8
    • /
    • pp.751-758
    • /
    • 2017
  • The behavior of fatigue crack growth of nickel-based powder metallurgy superalloy that could be used in aircraft turbine disc is investigated at room temperature, and $650^{\circ}C$ considering real operating conditions. The direct current potential drop(DCPD) method was used to measure the crack length of material in real time according to ASTM E647. Tests were performed with various stress ratios (0.1 and 0.5). Experimental results show that stress ratio, and temperature all affect the behavior of fatigue crack growth. As the stress ratio and temperature increase, the fatigue crack growth rate of nickel-based powder metallurgy superalloy also increases. Results were compared and reviewed with fatigue crack growth rates of other nickel-based superalloy materials (Inconel-100) that were studied in previous papers. Fractography analysis of the fractured specimens was performed using as SEM.

Principles of Intraoperative Neurophysiological Monitoring with Insertion and Removal of Electrodes (수술 중 신경계감시검사에서 검사에 따른 전극의 삽입 및 제거방법)

  • Lim, Sung Hyuk;Park, Soon Bu;Moon, Dae Young;Kim, Jong Sik;Choi, Young Doo;Park, Sang Ku
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.51 no.4
    • /
    • pp.453-461
    • /
    • 2019
  • Intraoperative neurophysiological monitoring (INM) examination identifies the damage caused to the nervous system during surgery. This method is applied in various surgeries to validate the procedure being performed, and proceed with confidence. The assessment is conducted in an operating room, using subdermal needle electrodes to optimize the examination. There are no textbooks or guides for the correct stimuli and recording areas for the surgical laboratory test. This article provides a detailed description of the correct stimuli and recording parts in motor evoked potential (MEP), somatosensory evoked potential (SSEP), brainstem auditory evoked potentials (BAEP) and visual evoked potentials (VEP). Free-running Electromyography (EMG) is an observation of the EMG that occurs in the muscle, wherein the functional state of most cranial nerves and spinal nerve roots is determined. In order to help understand the test, an image depicting the inserting subdermal needle electrodes into each of the muscles, is attached. Furthermore, considering both the patient and the examiner, a safe method is suggested for removal of electrodes after conclusion of the test.