• Title/Summary/Keyword: operating rating

Search Result 152, Processing Time 0.026 seconds

An Investigation on the Fault Currents in 22.9 kV Distribution System Due to the Increased Capacity and Operating Conditions of Power Transformers in 154 kV Substation (154 kV 변전소 주변압기의 용량 및 운전조건이 22.9 kV 배전계통의 고장전류에 미치는 영향)

  • Cho, Seong-Soo;Han, Sang-Ok
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.57 no.3
    • /
    • pp.302-310
    • /
    • 2008
  • In order to evaluate the nominal rating of breakers in distribution system due to the increased capacity and operating conditions of power transformers in 154 kV substation, the fault currents in distribution system were calculated by the conventional method and simulations of PSCAD/EMTDC program. Consequently, under the condition of the parallel operation of transformers, the fault currents exceed the nominal current of the breakers in some areas. Without NGR at the secondary neutral of the transformer, the current of single line-to-ground fault was bigger than that of 3-phase fault. Therefore, the results clearly show that the measures to limit the fault currents in distribution system are needed when the increased capacity of power transformers is introduced into 154 kV substation.

Convalescent Hospital Doctors and Nursing Staff Awareness of the Differential Rating : Focused on Doctors, Nursing Staff (요양병원 의사 및 간호인력 차등등급에 따른 인지도 - 의사, 간호인력 중심으로)

  • Kim, Byung-Ho;Park, Young-Seok
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.12
    • /
    • pp.285-293
    • /
    • 2015
  • This study was performed in order to provide better quality health care services and satisfaction, the basis for the differential rating system to be operational by identifying how to recognize and respect in hospital operating efficiently and according to the rating differential with convalescent hospital doctors and nursing staff target was. The results of this study are as follows. Rating and doctors as a result of the independent sample t-test to analyze the differences of the nursing grade, second grade doctors were able to see that higher efficiency and improve the patient's rights organization in nursing improving patient safety in two grades, improve care and patient rights this product was confirmed to be enhanced higher. Doctor and as a result of the ANOVA analysis to analyze the differences in accordance with the nursing staff level, improve patient safety, hospital finances, the hospital doctor in the first grade, Nursing grade 2, the right to improve patient education and self-development, and two doctors, nursing grade 1 in was found that high. Overall, doctors, nursing staff of higher grade, first grade and second grade is the difference between me and a different result each category future convalescent hospital doctors and nursing staff of the differential rating system 1, it is necessary to consider restructuring among a calculation based on 2 ratings there will be.

A Comparison of Urban Growth Probability Maps using Frequency Ratio and Logistic Regression Methods

  • Park, So-Young;Jin, Cheung-Kil;Kim, Shin-Yup;Jo, Gyung-Cheol;Choi, Chul-Uong
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.38 no.5_2
    • /
    • pp.194-205
    • /
    • 2010
  • To predict urban growth according to changes in landcover, probability factors werecal culated and mapped. Topographic, geographic and social and political factors were used as prediction variables for constructing probability maps of urban growth. Urban growth-related factors included elevation, slope, aspect, distance from road,road ratio, distance from the main city, land cover, environmental rating and legislative rating. Accounting for these factors, probability maps of urban growth were constr uctedusing frequency ratio (FR) and logistic regression (LR) methods and the effectiveness of the results was verified by the relative operating characteristic (ROC). ROC values of the urban growth probability index (UGPI) maps by the FR and LR models were 0.937 and 0.940, respectively. The LR map had a slightly higher ROC value than the FR map, but the numerical difference was slight, with both models showing similar results. The FR model is the simplest tool for probability analysis of urban growth, providing a faster and easier calculation process than other available tools. Additionally, the results can be easily interpreted. In contrast, for the LR model, only a limited amount of input data can be processed by the statistical program and a separate conversion process for input and output data is necessary. In conclusion, although the FR model is the simplest way to analyze the probability of urban growth, the LR model is more appropriate because it allows for quantitative analysis.

Electro-Optical Characteristics of an ICP Light Source Depending on Driving Temperature and Length of Discharge Tube (구동 온도와 방전관 길이에 따른 ICP 광원의 전기.광학적 특성)

  • Yim, Youn-Chan;Park, Dae-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.4
    • /
    • pp.107-113
    • /
    • 2008
  • We investigated the electro-optical characteristics of an ICP(Inductively Coupled Plasma) light source depending on driving temperature, and length of discharge tube. An electro-optical stability of a sample at operating was measured to see a steady state of a sample. In this results, we can see that a stability of power loss and luminous flux of a sample at operating of upper 70[min] was 1.45[%1 and 0.36[%]. We measured the optical characteristics of a sample in a thermal chamber operated at a specific temperature divided into 5 steps. While luminance increased with temperature increasing, the decrement of luminance a eared at u or $46.7[^{\circ}C]$. According to Parchen's and Boyle-Charles' law, we can speculate that a pressure was increased and a higher voltage was needed but a ballaster having a rating power can't support a higher voltage corresponding to a pressure change, 0.02[Torr] at $46.7[^{\circ}C]$. Moreover, we measured an a lied power and current of samples depending to a various length of a discharge tube.

Optimal Threshold from ROC and CAP Curves (ROC와 CAP 곡선에서의 최적 분류점)

  • Hong, Chong-Sun;Choi, Jin-Soo
    • The Korean Journal of Applied Statistics
    • /
    • v.22 no.5
    • /
    • pp.911-921
    • /
    • 2009
  • Receiver Operating Characteristic(ROC) and Cumulative Accuracy Profile(CAP) curves are two methods used to assess the discriminatory power of different credit-rating approaches. The points of optimal classification accuracy on an ROC curve and of maximal profit on a CAP curve can be found by using iso-performance tangent lines, which are based on the standard notion of accuracy. In this paper, we offer an alternative accuracy measure called the true rate. Using this rate, one can obtain alternative optimal threshold points on both ROC and CAP curves. For most real populations of borrowers, the number of the defaults is much less than that of the non-defaults, and in such cases the true rate may be more efficient than the accuracy rate in terms of cost functions. Moreover, it is shown that both alternative scores of optimal classification accuracy and maximal profit are the identical, and this single score coincides with the score corresponding to Kolmogorov-Smirnov statistic used to test the homogeneous distribution functions of the defaults and non-defaults.

Application of Combustion Stabilization Devices to Liquid Rocket Engine (액체 로켓엔진에서 연소 안정화기구의 적용 효과)

  • Sohn, Chae-Hoon;Seol, Woo-Seok;Lee, Soo-Yong;Kim, Young-Mog;Lee, Dae-Sung
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.6
    • /
    • pp.79-87
    • /
    • 2003
  • Application of combustion stabilization devices such as baffle and acoustic cavity to liquid propellant rocket engine is investigated to suppress high-frequency combustion instability, i.e., acoustic instability. First, these damping devices are designed based on linear damping theory. As a principal design parameter, damping factor is considered and calculated numerically in the chambers with/without these devices. Next, the unbaffled chambers with/without acoustic cavities are tested experimentally for several operating conditions. The unbaffled chamber shows the peculiar stability characteristics depending on the operating condition and it is found to have small dynamic stability margin. As a result, the acoustic cavity with the present design has little stabilization effect in this specific chamber. Finally, stability rating tests are conducted with the baffled chamber, where evident combustion stabilization is observed, which indicates sufficient damping effect.

Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor (단상유도전동기의 돌입전류저감을 위한 제어기 설계)

  • Park, Su-Kang;Baek, Hyung-Lae;Lee, Sang-Il
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.50 no.5
    • /
    • pp.238-245
    • /
    • 2001
  • During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch.

  • PDF

Droop Control Method for Circulating Current Reduction in Parallel Operation of BESS (BESS의 병렬운전 시 발생되는 순환 전류 저감을 위한 드룹 제어 기법)

  • Sin, Eun-Suk;Kim, Hyun-Jun;Yang, Won-Mo;Han, Byung-Moon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.5
    • /
    • pp.708-717
    • /
    • 2015
  • This paper proposes a new reduction scheme of circulating current when two units of BESS (Battery Energy Storage System) are operated in parallel with conventional droop control. In case of using conventional droop, the terminal voltage of each BESS are not equal due to the unequal line impedance, which causes the circulating current. The operation performance of BESS is critically dependant on the circulating current because it increases system losses which causes the increasement of required system rating. This paper introduces a new reduction scheme of circulating current in which the terminal voltage difference of each BESS is compensated by adding feed-forward path of line voltage drop to the droop control. The feasibility of proposed scheme was first verified by computer simulations with PSCAD/EMTDC software. After then a hardware prototype with 5kW rating was built in the lab and many experiments were carried out. The experimental results were compared with the simulation results to confirm the feasibility of proposed scheme. Two parallel operating BESS with proposed scheme shows more accurate performance to suppress the circulating current than those with the conventional droop control.

Clinical Utility and Cut-Off Scores of the Korean Adult Attention-Deficit/Hyperactivity Disorder Rating Scale

  • Hong, Minha;Lee, Young Sik;Kim, Bongseog;Joung, Yoo Sook;Yoo, Hanik K;Kim, Eui-Jung;Lee, Soyoung Irene;Bhang, Soo Young;Lee, Seung Yup;Han, Doughyun;Bahn, Geon Ho
    • Journal of the Korean Academy of Child and Adolescent Psychiatry
    • /
    • v.30 no.3
    • /
    • pp.116-120
    • /
    • 2019
  • Objectives: This study was conducted to re-validate the clinical efficacy of the Korean Adult Attention-Deficit/Hyperactivity Disorder (ADHD) Rating Scale (K-AARS), which is a self-report scale for ADHD in adults, and to determine the clinical utility and cut-off scores of K-AARS. Methods: The participants were 135 drug naïve adults with ADHD and 144 healthy controls. To diagnose ADHD based on the diagnostic criteria of the Diagnostic and Statistical Manual of Mental Disorders, 5th Edition, two board-certified pediatric psychiatrists interviewed the participants and completed the Mini International Neuropsychiatric Interview. K-AARS was applied to all participants. K-AARS comprises six clinical subscales, one impairment subscale, and one driving behavior subscale. The receiver operating characteristic analysis was conducted to calculate the cut-off scores of K-AARS. Results: All subscale scores, including six clinical subscale, impairment subscale, and driving behavior subscale scores, were found to be significant in distinguishing adults with ADHD from healthy controls. The sensitivity and specificity of the six clinical subscales were 63.0-77.0% and 66.7-79.9%, respectively. The combined total score of the six clinical subscales, had a sensitivity of 80.0% and specificity of 79.9%. Conclusion: The discriminative power of K-AARS for the diagnosis of ADHD in adults was excellent, and K-AARS and the empirical diagnosis of adults can be useful in diagnosing ADHD in adulthood.

A Study on Improvement of Trade Credit Insurance Rating for Capital Impaired Foreign Buyers (자본잠식 수입자에 대한 무역보험 신용평가 개선방안 연구)

  • Kyung-Chul Kim
    • Korea Trade Review
    • /
    • v.48 no.3
    • /
    • pp.89-106
    • /
    • 2023
  • This study is to investigate the problem of credit rating by Korea Trade Insurance Corporation(KSURE) which evaluates overseas buyers in a state of capital impairment as G-grade regardless of the cause of capital impairment. This study classifies capital impairment into two types: deficit-type capital impairment due to accumulated operating losses and surplus-type capital impairment due to shareholder return policies such as dividends and treasury stock buybacks. It is proposed to improve the credit evaluation method on companies with surplus capital impairment from a formal review to a substantive review. This study is expected to improve credit rating of KSURE on overseas buyers for better support of trade credit insurance for exporters.