• 제목/요약/키워드: operating rate of power plant

검색결과 109건 처리시간 0.036초

Plant Minimum Stable Load (Pmin) Test for Ilijan CCPP

  • Kim, Si Moon;Yun, Wan No;Jang, Cheol Ho;Park, Se Ik
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제2권1호
    • /
    • pp.83-88
    • /
    • 2016
  • This paper describes the test results of plant minimum stable load (Pmin) for Ilijan Power Plant. The test was conducted on May 13 through 14, 2015 to investigate the plant operating and equipment condition in accordance with "Ilijan Plant Performance Test Procedure on Plant Minimum Stable Load" [1]. This paper also contains the assessment of the impact of Pmin to plant operating parameters and possible technical operating issues when operating at lower loads and to recommend the safe minimum load operation of Ilijan per block. In addition, this paper describes the performance calculation results of efficiency and heat rate depending on the load level.

매립가스 자원화를 위한 가스엔진 발전의 수익성에 관한 연구 (A Study on Profitability of Power Plant for Landfill Gas)

  • 김오우;이정일
    • 산학경영연구
    • /
    • 제19권2호
    • /
    • pp.69-94
    • /
    • 2006
  • 매립된 패기물의 분해과정에서 생성되는 부산물로서의 매립가스는 악취와 환경오염을 유발하는 유해한 가스로 여겨져 왔다. 그러나 발열량이 $5,000kcal/m^3$에 달하는 매립가스의 특성은 에너지원으로써의 활용가치가 탁월한데다 지구온난화의 주범으로 떠오르면서 그 회수 필요성이 더욱 강조되고 있어, 재생에너지로서의 매립가스를 대체에너지 자원으로 이용하려는 추세는 매우 고무적인 현상이라 하겠다. 현재 우리나라의 매립가스자원화 사업은 가스엔진을 이용한 전력생산이 대부분을 차지하고 있으며, 부분적으로 중질가스와 고질가스의 활용에도 관심을 보이고 있다. 가스발전기의 가동률과 전력단가의 변동을 고려하여 매립가스의 경제성을 분석해본 결과, 초기 투자비 회수와 지속적인 수익성 확보를 위해서는 최소한 10년 이상의 발전사업 운영 및 전력판매 단가의 현실화가 요구되고 있다.

  • PDF

매립가스 자원화를 위한 가스엔진 발전의 수익성에 관한 연구 (A Study on Profitability of Power Plant for Landfill Gas)

  • 김오우;이정일
    • 한국산학경영학회:학술대회논문집
    • /
    • 한국산학경영학회 2006년도 춘계학술발표대회 발표논문집
    • /
    • pp.147-170
    • /
    • 2006
  • 재생에너지로서의 매립가스는 매립된 폐기물의 분해과정에서 생성되는 부산물로서 악취와 환경오염을 유발하는 유해한 가스로 여겨져 왔으나, 최근 들어 매립가스를 대체에너지 자원으로 이용하려는 추세가 나타나고 있음은 매우 고무적인 현상이라 하겠다. 발열량이 $5,000kcal/m^3$에 달하는 매립가스의 특성은 에너지원으로써의 활용가치가 탁월한데다 지구온난화의 주범으로 떠오르면서 그 회수 필요성이 더욱 강조되고 있는 실정이다. 현재 우리나라의 매립가스자원화 사업은 가스엔진을 이용한 전력생산이 대부분을 차지차고 있으며, 부분적으로 중질가스와 고질가스의 활용에도 관심을 보이고 있다. 가스발전기의 가동률과 전력단가의 변동을 고려하여 매립가스의 경제성을 분석해본 결과, 초기 투자비 회수와 지속적인 수익성 확보를 위해서는 최소한 10년 이상의 발전사업 운영 및 전력판매 단가의 현실화가 요구되고 있다.

  • PDF

터빈 사이클 열소비율 정확도 추정 모델 (Uncertainty Estimation Model for Heat Rate of Turbine Cycle)

  • 최기상;김성근;최광희
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.1721-1726
    • /
    • 2004
  • Heat rate is a representative index to estimate the performance of turbine cycle in nuclear power plant. Accuracy of heat rate calculation is dependent on the accuracy of measurement for plant status variables. Uncertainty of heat rate can be modeled using uncertainty propagation model. We developed practical estimation model of heat rate uncertainty using the propagation and regression model. The uncertainty model is used in the performance analysis system developed for the operating nuclear power plant.

  • PDF

Membrane distillation of power plant cooling tower blowdown water

  • Ince, Elif;Uslu, Yasin Abdullah
    • Membrane and Water Treatment
    • /
    • 제10권5호
    • /
    • pp.321-330
    • /
    • 2019
  • The objective of this study was to examine the recovery of the power plant cooling tower blowdown water (CTBD) by membrane distillation. The experiments were carried out using a flat plate poly vinylidene fluoride (PVDF) membrane with a pore diameter of $0.22{\mu}m$ by a direct contact membrane distillation unit (DCMD). The effects of operating parameters such as transmembrane temperature difference (${\Delta}T$), circulation rate and operating time on permeate flux and membrane fouling have been investigated. The results indicated that permeate flux increased with increasing ${\Delta}T$ and circulation rate. Whereas maximum permeate flux was determined as $47.4L/m^2{\cdot}h$ at ${\Delta}T$ of $50^{\circ}C$ for all short term experiments, minimum permeate flux was determined as $7.7L/m^2{\cdot}h$ at ${\Delta}T$ of $20^{\circ}C$. While $40^{\circ}C$ was determined as the optimum ${\Delta}T$ in long term experiments. Inorganic and non-volatile substances caused fouling in the membranes.

발전용 증기밸브 누설량 평가에 관한 연구 (Study on Evaluation of the Leak Rate for Steam Valve in Power Plant)

  • 이상국;박종혁;유근배
    • 동력기계공학회지
    • /
    • 제11권1호
    • /
    • pp.45-50
    • /
    • 2007
  • Acoustic emission technology is applied to diagnosis the internal leak and operating conditions of the major valves at nuclear power plants. The purpose of this study is to verify availability of the acoustic emission as in-situ diagnosis method. In this study, acoustic emission tests are performed when the pressurized high temperature steam flowed through gate valve(1st stage reheater valve) and glove valve(main steam dump valve) on the normal size of 4 and 8". The valve internal leak diagnosis system for practical field was designed. The acoustic emission method was applied to the valves at the site, and the background noise was measured for the abnormal plant condition. To improve the reliability, a judgment of leak on the system was used various factors which are AE parameters, trend analysis, signal level analysis and RMS(root mean square) analysis of acoustic signal emitted from the valve operating condition internal leak.

  • PDF

하동 화력 발전소 전범위 시뮬레이터 개발 (A Full Scale Fossil Power Plant Simulator For Hadong)

  • 김성호;김종현;조창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2000년도 제15차 학술회의논문집
    • /
    • pp.204-204
    • /
    • 2000
  • This paper describes the development of training simulator for Hadong fossil Power Plant. The simulator was developed to train operator, test new control Logic and evaluate alternative operating procedure for expert engineer of control system. The most control logics such as Siemens TELEPERM ME and GE Mark V are translated directly from microprocessors. Those HMI are also directly emulated. The simulation was performed by ProTRAX modeling software. The paper discusses the configuration of simulator and the simulation results of 30%, 50%, 75% and 100% normal rate load test.

  • PDF

각기 다른 열소비율 보정곡선을 갖는 증기터빈의 최적 복수기 운전압력 설정 (The steam turbine condenser pressure optimization with different heat rate correction curves)

  • 조천환;백남호;허진혁;이재헌;문승재;유호선
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.224-227
    • /
    • 2008
  • The present study performs a test of a change in a condenser pressure on two kinds of power plants having different condenser pressure-heat rate correction curve and evaluates the results. According to a result of the test, it is confirmed that a sub-critical drum type steam power plant is optimally operated at the condenser pressure of 38㎜Hga that is designed, even during winters. On the other hand, it can be found that a supercritical once through type steam power plant operated at the condenser pressure that is reduced below a design value, that is, up to 28㎜Hga during winters is advantageous in view of turbine efficiency and is operated without a problem in facility operation such as moisture erosion, turbine vibration, etc. Also, the present study compares and reviews a condenser pressure-heat rate correction curve proposed by a manufacturer and a test value. The present study proposes optimum condenser operation pressure capable of concurrently satisfying the stable operation and efficiency improvement of the power plant facility that is operating, making it possible to support an efficient operation of a power plant.

  • PDF

운전데이터에 의한 증기터빈 발전소의 부하제어에 관한 고찰 (A Study on Load Control in a Steam Turbine Power Plant using Acquired Data)

  • 우주희;최인규
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 B
    • /
    • pp.749-751
    • /
    • 1999
  • We acquired operating data in an existing steam turbine power plant using analog control system to investigate operation characteristics. We analyzed a load control logic to develop a digital turbine control system. The load control logic is constituted of load target, load reference, loading rate, load limit and admission mode transfer of valve. The result of this paper is utilized to implement a digital turbine control system.

  • PDF

조력발전과 해류발전을 겸하는 통합발전시스템 타당성 연구 (Feasibility Study on the Integration Power System combining Tidal Power Generation and Ocean Current Power Generation)

  • 장경수;이정은
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.611-614
    • /
    • 2009
  • The present paper relates to an integration power system combining tidal power generation and ocean current power generation, and more particularly, to an integration power system combining a tidal power plant and two ocean current power parks, which is capable of increasing the operating rate of power facilities and efficiently generating electrical energy by using incoming seawater into the lake through turbine generators of a tidal power plant or fast flow of seawater discharged to a sea side through sluice gates of a tidal power dam. It is shown that the integration power system is a new promising ocean power system and the ocean current turbine generators in the ocean current power parks of the integration power system are smaller in size and larger in power generation capacity compared with the tidal current turbine generators in the ocean.

  • PDF