• Title/Summary/Keyword: operating guidelines

Search Result 309, Processing Time 0.024 seconds

Improvement of Supervision Work in Cultural Heritage Repair (문화재 감리업무 개선방안 연구)

  • Park, Hwan-Pyo;Han, Jae-Goo;Kim, Kyong-Hoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.1
    • /
    • pp.61-71
    • /
    • 2020
  • The Cultural Heritage Administration is operating the resident supervision and non-resident supervision system to prevent poor repair and ensure the quality of cultural heritage repairs And recently, responsible supervision system was introduced to enhance the supervision of cultural heritage repairs. However, many problems have arisen in the operation of the supervision work, and need improvement. Accordingly, this study improved the resident and non-resident supervision of cultural heritage repair and developed work guidelines for the responsible supervision. First, this research has derived unreasonable sectors and problems of work guidelines for resident supervision about cultural heritage repair and has suggested supervision work guidelines which are improved. Second, we have derived the problems of work guidelines for non-resident supervision about cultural heritage repair and has suggested non-resident supervision work guidelines which are improved. Third, this paper has proposed the development direction and detailed supervision work to perform responsible supervision as a result of the adoption of the supervision system for cultural heritage repair.

A Study on Guideline for the Digitalized R&D Information Security (전자화된 연구개발정보 보호를 위한 가이드 개발 연구)

  • Kyung, Tae-Won;Kim, Kyung-Hun;Song, Young-Jae
    • Journal of Digital Convergence
    • /
    • v.10 no.1
    • /
    • pp.341-347
    • /
    • 2012
  • The study provides the direction for constructing and operating ELN(Electronic Laboratory Notebook) system for systematic record, management and reliability security of the document. Firstly, Present the standard of the system environment for writing and management of ELN. Secondly, Establish guidelines for systematic maintenance and operation of ELN system. Thirdly, Draw up guidelines of inspection whether ELN system is managed in according with the standards and procedures. Therefore, it is expected that these guidelines contribute to vitalize ELN and set foundation of application for researching and developing information in the medium and long term.

A Study on the Determination of Voltage Limits for Korean Power System Reliability (국내 전력계통 신뢰도 기준을 위한 전압 제한범위 결정에 관한 연구)

  • Flores, BenJeMar-Hope F.;Aryani, Dwi Riana;Kim, Seungjin;Song, Hwachang
    • Proceedings of the KIEE Conference
    • /
    • 2015.07a
    • /
    • pp.335-336
    • /
    • 2015
  • Voltage collapse is one of the main threats in power system operation and it is a result of a very low voltage profile in one or multiple areas in the power system network. Hence, the need for proper coordination among transmission and generator operators to maintain voltage stability if of paramount importance. In this paper, the different voltage and reactive power operating guidelines and criteria of various electric reliability councils, coordinating councils, transmission system operators and other electric utilities are discussed. Among these are NERC, ENTSO-E, WECC, PJM and ERCOT. A comprehensive comparison is also made to the existing Korean power system voltage reliability guidelines. Furthermore, this paper presents a set of voltage and reactive power guidelines that can help in determining voltage limits that can improve the reliability of the Korean power system operation.

  • PDF

A Study on the Circulation System of Biosafety Level 4 Laboratory Facilities (생물안전 4등급(BL4) 실험시설의 동선계획에 관한 연구)

  • Kwon, Soonjung;Choi, Hongbin
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.17 no.1
    • /
    • pp.23-32
    • /
    • 2011
  • Recently, with the advent of high risk infectious agent such as the Ebola virus, SARS, special research facilities dealing with such dangerous pathogenic are drawing attention gradually. Especially, this kind of facilities can be called BL4(Biosafety Level 4) facility. At the moment, Korean government is going to construct BL4 institute in order to handle efficiently such kind of pathogen. However, there are no proper design guidelines for BL4 facility. This paper proposes circulation system of BL4 facility on the basis of analysis of existing BL4 guidelines of Canada, and Korean BL3 facilities. The outcomes of this study are as follows. At first, functional areas of BL4 facilities have been divided into three categories according to the hazard level ; dangerous area, transitional area, and ordinary area. Secondly, circulation system of BL4 facility has been explored as a form of diagram according to the circulating subjects. These include human, laboratory animals, hazardous pathogen, equipments and cloth. This study has some limitations in that it lacks empirical evidences and concrete SOPs(Standard Operating Procedure). Despite of some weaknesses, it is expected to give some preliminary guidelines for the design of circulation system in BL4 facilities.

Experimental Study on $CO_2$ Level Fluctuation by Door-opening of Subway (전동차 출입문 개폐에 따른 객실 이산화탄소 농도변화의 실험적 연구)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Park, Eun-Young;Kim, Se-Young;Jung, Mi-Young;Ham, Dae-Joo
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1652-1655
    • /
    • 2008
  • Indoor air quality (IAQ) of subway becomes a key issue as the IAQ guidelines for public transportation published. There are two major sources regarding IAQ of subway; One is the sources coming from outdoor air and the other is sources of inside. Particulate matters smaller than 10 micrometer (PM10) and carbon dioxide ($CO_2$) are recognized as the one of the most severe pollutants in Korea. The source of PM10 is mainly coming from outdoor air, however, the source of $CO_2$ is coming from passengers exhaust. According to the guidelines, the level of $CO_2$ should be lower than 2500ppm for normal operating time and lower than 3500ppm for rush hour. In order to satisfy these guidelines, the volume of mechanical ventilation should be increase which consumes extra energy for heating or cooling. Therefore, the optimum volume of mechanical ventilation should be calculated for energy saving. In this study, we measured the natural ventilation rate by door-opening which can reduce the load of mechanical ventilation. The $CO_2$ generator and sensors were used to measure the change of $CO_2$ by periodic door-opening of subway.

  • PDF

A Study on the Architectural Planning of the Ward in Infectious Disease Hospitals (감염병 전문병원의 병동부 건축계획에 관한 연구)

  • Choi, Kwangseok
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.27 no.1
    • /
    • pp.7-15
    • /
    • 2021
  • Purpose: This study analyzed the architectural planning factors of the ward in infectious disease hospitals, such as functional unit planning, ward configurations, spatial compositions & circulation, and detailed architectural planning. Through these, the facility guidelines of infectious disease hospitals are summarized, focusing on the differences from the wards of non-infectious hospitals. Methods: This study was conducted by literature review of research reports, papers, design cases, and guidelines, based on the experiences of field surveys for infectious disease hospitals. Results: The result of this study can be summarized into a few points. 1) Infectious disease hospitals need to establish an operation plan with the concept of continuity of care, as an extension of existing facilities. 2) The types of ward configuration for infectious disease hospitals has many variables, so an appropriate type should be selected according to the hospital's operating policy. 3) Various spatial composition types of the ward can be planned by the arrangement of traffic cores and areas of patient groups. At this time, the main planning considerations are safety, efficiency, and comfort. 4) As elements of the detailed plan, It is necessary to consider the types & dimensions of patient rooms, the relationships between nursing stations & sub-stations, and supplementations of medical support functions & convenience facilities. Implications: Since there are many differences in function from the ward of non-infectious hospitals, appropriate facility guidelines for infectious disease hospital are required.

Numerical Investigation of Large-capacity Wind Turbine Wake Impact on Drone system during Maintenance (수치해석 활용 대용량 풍력발전시스템 유지보수 시 타워 및 블레이드 후류에 따른 드론 블레이드 간섭 연구)

  • Jun-Young Lee;Hyun-Choi Jung;Jae-ho Jeong
    • Journal of Wind Energy
    • /
    • v.14 no.3
    • /
    • pp.100-108
    • /
    • 2023
  • The aim of this study is to develop guidelines for predicting interference between drones and wakes during non-destructive blade inspections in wind power systems. The wake generated by wind towers and blades can affect the stability of drone flights, necessitating the establishment of guidelines to ensure safe and efficient inspections. In order to predict the interference between drones and blades, environmental variables must be considered, including quantification of turbulence intensity in the wake generated by the tower and blades, as well as determining the appropriate distance between the drone and the tower/blades for flight stability. To achieve this, computational fluid dynamics (CFD) analysis was performed using cross-sectional geometries corresponding to the main wind turbine blade and tower span locations. Based on the CFD analysis results, a safe flight path for drones is proposed, which minimizes the risk of collision and interference with towers and blades during maintenance operations of wind power systems. Implementation of the proposed guidelines is expected to enhance the safety and efficiency of maintenance work.

A New Reclosing and Re-breaking DC Thyristor Circuit Breaker for DC Distribution Applications

  • Kim, Jin-Young;Choi, Seung-Soo;Kim, In-Dong
    • Journal of Power Electronics
    • /
    • v.17 no.1
    • /
    • pp.272-281
    • /
    • 2017
  • The DC circuit breaker is essential for supplying stable DC power with the advent of DC transmission/distribution and sensitive loads. Compared with mechanical circuit breakers, which must interrupt a very large fault current due to their slow breaking capability, a solid-state circuit breaker (SSCB) can quickly break a fault current almost within 1 [ms]. Thus, it can reduce the damage of an accident a lot more than mechanical circuit breakers. However, previous DC SSCBs cannot perform the operating duty, and are not economical because many SCR are required. Therefore, this paper proposes a new DC SSCB suitable for DC grids. It has a low semiconductor conduction loss, quick reclosing and rebreaking capabilities. As a result, it can perform the operating duties of reclosing and rebreaking. The proposed DC SSCB is designed and implemented so that it is suitable for home dc distribution at a rated power of 5 [kW] and a voltage of 380 [V]. The operating characteristics are confirmed by simulation and experimental results. In addition, this paper suggests design guidelines so that it can be applied to other DC grids. It is anticipated that the proposed DC SSCB may be utilized to design and realize many DC grid systems.

Comparative analysis for improving the effective application of HACCP prerequisite items in meat markets (식육판매장 HACCP 선행요건의 효율적인 적용을 위한 비교분석)

  • Hong, Chong-Hae;Na, Hae-Seo
    • Korean Journal of Veterinary Service
    • /
    • v.33 no.4
    • /
    • pp.393-399
    • /
    • 2010
  • We analyzed the HACCP prerequisite of National Veterinary Research and Quarantine Service (NVRQS) and the Food Establishment Inspection Report of US Food and Drug Administration (FDA) to recommend contents and ranges to be complemented and used for preparation of guidelines for more effective application of HACCP prerequisites. We used the HACCP inspection reports implemented by Korea Livestock Products HACCP Accreditation Service from 2007 to 2009, FDA Food Code 2009 Guide 3-B Instructions for Marking the Food Establishment Inspection Report, and Retail Food Establishment Sanitation Requirements of 410 Indiana Administrative Code. Major non-compliance items were open doors and windows, insanitary cleaning of in-use utensil, inadequate record of warehousing, and improper storage, transportation, and labelling. Hot water supply, personal hygiene, and regular product testing were additional week points which should be more strongly controlled by detailed operating guidelines. Also, current prerequisite items were required revision into more precise contents to enhanced the effective evaluation and practical application in meat markets.

A Novel Soft-Switching Full-Bridge PWM Converter with an Energy Recovery Circuit

  • Lee, Dong-Young;Cho, Bo-Hyung;Park, Joung-Hu
    • Journal of Power Electronics
    • /
    • v.9 no.5
    • /
    • pp.809-821
    • /
    • 2009
  • This paper proposes a new phase-shift full-bridge DC-DC converter by applying energy recovery circuits to a conventional full-bridge DC-DC converter in plasma display panel applications. The converter can achieve soft-switching in main-switches by an extra auxiliary resonant network even with the wide operating condition of both output load and input voltage. The un-coupled design guidelines to the main bridge-leg component parameters for soft-switching operation contribute to conduction loss reduction in the transformer primary side leading to efficiency improvement. The auxiliary switches in the resonant network also operate in zero-current switching. This paper analyzes the operation modes of the proposed scheme and presents the key design guidelines through steady state analysis. Also, the paper verifies the validity of the circuits by hardware experiments with a 1kW DC/DC converter prototype.