• Title/Summary/Keyword: operating characteristics

Search Result 5,674, Processing Time 0.035 seconds

The Characteristics of Dust Removal in Flue Gas by the Plasma of Impulse Streamer Corona (충격식 코로나 방전 플라즈마를 이용한 배연가스로부터 먼지제거에 대한 특성)

  • 김은호
    • Journal of Environmental Science International
    • /
    • v.12 no.12
    • /
    • pp.1261-1267
    • /
    • 2003
  • On the basis of the distribution of particle size measured by laser diffraction spectrometers, this research was carried out to investigate the characteristics of mist removal with the change of operating condition in the plasma reactor of impulse streamer corona. The operating parameters in this experiment were power of impulse streamer corona, gas velocity, impulse generation time, gas temperature, and SOx/NOx concentration. The collection efficiency T(d) was estimated by the distribution of particle size in the collection zone through the advanced model.

An Experimental Study of Three Buffer Pulse Tube Refrigerator (Three buffer 맥동관 냉동기에 관한 실험적 연구)

  • 박성제;고득용;김효봉;신완순
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.189-193
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus was constructed. This paper presents operating process of three buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in three pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27W at 120K.

  • PDF

An Experimental Study of a Therr Buffer Pulse Tube Refrigerator (Three Buffer 맥동관 냉동기에 관한 실험적 연구)

  • 박성재;고득용;김효봉;신완순
    • Progress in Superconductivity and Cryogenics
    • /
    • v.1 no.2
    • /
    • pp.54-59
    • /
    • 1999
  • An experimental study was carried out to improve the cooling capacity and performance of the pulse tube refrigerator. Three buffer pulse tube refrigerator was designed and fabricated, and the experimental apparatus operating process of the therr buffer pulse tube refrigerator and results obtained with the performance test. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the three buffer pulse tube refrigerator was 88K and the cooling capacity at the optimum operating condition was 27 W at 120K.

  • PDF

Performance Test of the Stirling Cryocooler for Cooling of the Infrared Detectors (적외선 센서 냉각용 스터링 냉동기의 성능시험)

  • 고득용;박성제;김효봉;염한길;김홍국;김남환
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 1999.02a
    • /
    • pp.202-206
    • /
    • 1999
  • This paper presents operating process of the Stirling cryocooler and results obtained with the performance test for Signal Usfa UP 7075 Stirling cryocooler. An experimental study was carried out to develop the more reliable Stirling cryocooler. The cooldown characteristics and load characteristics are described. The lowest temperature measured in the Stirling cryocooler wa 62.5K and the cooling capacity at the optimum operating condition was 0.4W at 77K. At that time, carnot COP was 0.024.

  • PDF

Determination of Operating frequency its Design of the Self-exited electronic Ballast (자려식 전자안정기의 동작 주파수 결정과 설계)

  • 박종연;전경준;한재현
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.315-318
    • /
    • 2002
  • In this paper, we have studied about the determination methode of the operating frequency, and the design technique for the self-exited electronic ballast. Because we use the saturation characteristics of the ferrite core, the variation of the B/H curve characteristics for the selected core in the most important factor for the stabilization. Although it is impossible to fix the operation frequency, the self-exited electronic ballast is widely used because of its cost and the simplicity of its structure.

  • PDF

The devlepment of a MPC controller for water level control in the steam generator of a nuclear power plant (원전 증기발생기 수위제어를 위한 MPC 제어기 개발)

  • 손덕현;한진욱;이환섭;이창구
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.359-359
    • /
    • 2000
  • Generally, level control in the steam generator of a nuclear power plant is difficulty process control, because the low power operating can lead nonminimum phase characteristics(swell and shrink phenomenon) and flow measurement are unreliable and nonlinear characteristics. This paper presents a framework for solving this problem based on the constrained linear model predictive control and introduces the design of method for the level of the controller in the entire operating power of the steam generator, and compares with conventional PI controller.

  • PDF

A Study on the Operating Characteristics for a Grid-Connected Photovoltaic Power System (계통연계형 태양광 발전시스템의 운전특성에 관한 연구)

  • Ahn, K.S.;Hwang, I.H.;Jeong, S.J.;Lim, H.C.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07g
    • /
    • pp.2436-2438
    • /
    • 1998
  • The operating characteristics of a 3 kW grid-connected photovoltaic (PV) power system was studied by analying annual photovoltaic data. The system performance for grid connection was investigated using a DC/ AC inverter. The results of a demonstration test show that the system utilization rate is 15.6% and the system efficiency is 8.03%.

  • PDF

Operating Characteristics Analysis of Disk type Single-phase SRM (디스크형 단상 SRM의 동작 특성 해석)

  • Lee, Jong-Han;Oh, Young-Woong;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.191-193
    • /
    • 1999
  • The various advantages of DSPSRM lie in constructional simplicity, robustness and low cost. Also it has a specific characteristic of axial flux machine and radial flux machine simultaneously. In this paper, we designed and manufactured its operating drive and measured the characteristics of torque, efficiency, current to speed.

  • PDF

Implementation of the Dynamic Simulator for Predicting Operating Characteristics of Three-Phase Induction Motors (유도전동기의 운전 특성 예측을 위한 동적 시뮬레이터 구성)

  • Pyon, H.S.;Hahn, S.C.
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.906-908
    • /
    • 2000
  • This paper presents dynamic modeling and simulation of induction motors. Equivalent circuit parameters measured by do test, no-load test and locked-rotor test were used as the input data for computer simulation. Operating characteristics of an induction motor were predicted by Matlab/simulink when changing load torque, opening and reclosing of phase a of the stator and three-phase fault at machine terminals.

  • PDF

Operating Characteristics Analysis of TCSC Simulator with Damping Resistor (제동 저항 인가에 따른 TCSC 시뮬레이터의 특성 분석)

  • Jeon, Jin-Hong;Kim, Kwang-Su;Kim, Ji-Won;Chun, Yeung-Han
    • Proceedings of the KIEE Conference
    • /
    • 2003.11a
    • /
    • pp.193-195
    • /
    • 2003
  • In this paper, we present the analysis results of TCSC(Thyritor Controlled Series Capacitor) operating characteristics with damping resisters. This TCSC system is designed for KERI simulator. It consists of many power system components, which are generator models, scale-downed transmission line modules, transformers, switches, FACTS(Flexible AC Transmission System) devices.

  • PDF