• Title/Summary/Keyword: opening a door

Search Result 187, Processing Time 0.028 seconds

A Study on the Design of Hemming Process for Automotive Body Panels (자동차 패널의 헤밍 공정 설계에 관한 연구)

  • 안덕찬;이경돈;인정제;김권희
    • Transactions of Materials Processing
    • /
    • v.9 no.6
    • /
    • pp.624-630
    • /
    • 2000
  • Typical automotive opening parts, i. e. hood trunk lid and door, are made through the press operations such as drawing, trimming, flanging, and hemming. The dimensional accuracy of stamped panels is mainly dependent on the drawing operation. However, the gap between outer panels and opening parts, which is important to the appearance quality of the assembled body, is directly influenced by the flanging and hemming operation. In this study, the relation between the design parameters of the hemming operation and the defect of roll-in is shown. The effects of some design parameters on the gap are examined using CAE. furthermore, the simulated results of the hemmed part of tailgate comer are shown and discussed.

  • PDF

A Study on the Conditions of Injection Pressurization in the Smoke-Control Zone II. Analysis of the Conditions for Closing Force of Fire Door with Variation of Angular Velocity (제연구역 방화문의 각속도 변화와 폐쇄 조건 분석)

  • Lee, Chang-Wook;Kim, Hong-Jin;Choi, Young-Ki;Youm, Moon Cheon;Ryou, Hong-Sun
    • Fire Science and Engineering
    • /
    • v.27 no.2
    • /
    • pp.6-10
    • /
    • 2013
  • This study aims to construct the performance data for smoke-control zone and realize the safety of injection and pressurization room which is composed of supply air pressure zone, vestibule, smoke-control zone and stairwell. To obtain this, smoke-control system and the device of the opening-closing force of fire door are manufactured. This subject is the analysis of the closing force, angular velocity and fire door size in the case of fixed volume flow rate. Based on the results, closing force increased as fire door size and closing angular velocity increases. Also, it is remark that there exists a critical angular velocity, which maintains constant maximum closing force even though the angular velocity increases more.

Comparison of Spinal Canal Expansion Following Cervical Laminoplasty Based on the Preoperative Lamina Angle : A Simulation Study

  • Jung, Jong-myung;Jahng, Anthony L.;Hyun, Seung-Jae;Kim, Ki-Jeong;Jahng, Tae-Ahn
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.2
    • /
    • pp.229-237
    • /
    • 2021
  • Objective : Expansion in the spinal canal area (SCA) after laminoplasty is one of the critical factors to relieve the preoperative symptoms. No previous study has compared the increases in SCA achieved by open-door laminoplasty (ODL) and double door laminoplasty (DDL) according to the preoperative lamina angle (LA). This study was designed to clarify the relationship between the laminoplasty opening angle (OA)/laminoplasty opening size (OS) and increases in the SCA following ODL and DDL according to the preoperative LA using a simulation model. Methods : The simulation model was constructed and validated by comparing the clinical data of 64 patients who had undergone C3-C6 laminoplasty (43 patients with ODL and 21 patients with DDL). SCA expansion was predicted with a verified simulation model at various preoperative LAs (from 28° to 32°) with different OAs (40° to 44°) and OSs (10 mm to 14 mm) recruited from patient data. Results : The constructed simulation model was validated by comparing clinical data and revealed a very high degree of correlation (r=0.935, p<0.001). In this validated model, at the same OA, the increase in SCA was higher following ODL than following DDL in the usual LA (p<0.05). At the same OS, the increase in SCA was slightly larger following DDL than following ODL, but the difference was not significant (p>0.05). The difference was significant when the preoperative LA was narrower or much wider. Conclusion : Based on clinical data, a simulation model was constructed and verified that could predict increases in the SCA following ODL and DDL. When applying this model, prediction in SCA increase using the OS parameter was more practical and compatible with clinical data. Both laminoplasties achieved enough SCA, and there was no significant difference between them in the usual range.

A Study on the Safety of Evacuation according to Evacuation Delay Time and Fire Door Openness: Based on Residence Types (피난 지연시간의 적용과 방화문 개방 정도에 따른 피난 안전성 확보에 관한 고찰 : 주거형태를 중심으로)

  • Seo, Dong-Gil;Kim, Mi-Seon;Gu, Seon-Hwan;Song, Young-Joo
    • Fire Science and Engineering
    • /
    • v.34 no.2
    • /
    • pp.156-165
    • /
    • 2020
  • In this paper, the application of evacuation delay time (Cognition time + initiation time) and examine the degree of opening of fire doors in households for evaluating evacuation safety and suggest a realistic alternative. In order to proceed with this study, first of all, the preliminary investigation on evacuation safety evacuation of residential-type buildings (Apartment, urban living houses, etc.) among the performance-oriented design targets of Gwangju Metropolitan City, which was implemented until June 2018. Then, for the two representative types that are commonly used among the previously surveyed buildings, evacuation delay time is applied to W1, W2, and respectively simulating the opening of the doors is applied to th full open, 1/4 open, the leakage gap and evacuation safety evaluation was performed. As a result of evaluating evacuation safety was found that it is difficult to secure evacuation safety regardless of evacuation delay time W1 and W2 when the fire door is fully open and 1/4 open, Only when the leakage gap is applied evacuation safety was ensured even if evacuation delay time W2 was applied. Therefore, when a residential building is subject to performance-oriented design, evaluating the application of W2 rather than W1 is considered for evacuation delay time to reflect concern about privacy infringement due to CCTV installation, etc. In order to secure the Smoke blocking performance of the fire door and to improve the performance-oriented design, I would like to propose to consider the method of applying a leak gap to the degree of opening of the fire door. Through this, it is expected that the performance-oriented design will be a step further by performing evacuation safety evaluation with more realistic data.

A Flow Analysis of a Refrigeration Warehouse where an Unusual Death of an Operator Occurred by Deficiency of Oxygen

  • Park, Chan-Seong;Moon, Jung-Eun;Kim, Yoon-Ho;Kim, Jin-Pyo
    • International Journal of Safety
    • /
    • v.5 no.2
    • /
    • pp.29-33
    • /
    • 2006
  • A numerical flow analysis of the case of a refrigeration warehouse where an unusual death of an operator occurred by deficiency of oxygen is performed by using STAR-CD program of the computational fluid dynamics (CFD) code. The refrigeration room of the warehouse for storing the fruits maintains an atmosphere of 95% nitrogen and 5% oxygen by volume. When the operator was found dead in the refrigeration room, the room was in normal operating conditions except for the fact that the auxiliary door had been left open. For the flow analysis, unsteady 3-dimensional natural convection with mass transfer is considered. The flow analysis result is compared with the oxygen concentration level measured against time during on-site investigation. The change in oxygen concentration level in the warehouse due to the opening of the auxiliary door is found to be negligible.

A Study on The Development of Container Security Device(CSD) based on Active RFID (능동형 RFID 기반 컨테이너 보안 장치(CSD)의 개발에 관한 연구)

  • Choi, Hyung-Rim;Kim, Jae-Joong;Kang, Moo-Hong;Shin, Joong-Jo;Shon, Jung-Rock;Moon, Young-Sik;Lee, Eun-Kyu
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.2B
    • /
    • pp.244-251
    • /
    • 2010
  • CSD is Active RFID based Container Security Device which is proposed by the U.S Department of Home Security. It is mounted inside the container to sense opening of the container door. ConTracer is the CSD which is developed in this research whose major features are sensing door opening status as well as history inquiring on internal environment and shock to the container by mounting the temperature/humidity/shock sensors. Moreover, its RFID frequency bandwidth uses 433MHz and 2.4GHz to correspond actively to the radio regulations used by different countries. This paper introduces the development trend of CSD, compares the ConTracer which is developed thru this research and other company's CSD, and introduces CSD System which is designed and established using ConTracer. Finally, the implemented CSD System is verified by applying the demonstration service to container distribution between Korea and China.

A study on the transition of the type of openings constructed at backside of DAECHUNG in Korean traditional architectures (전통건축 대청 배면 개구부형식의 변천에 관한 연구)

  • 정명섭
    • Journal of the Korean housing association
    • /
    • v.5 no.2
    • /
    • pp.29-40
    • /
    • 1994
  • The purpose of this study is to survey the transition of the type of openings in korean traditional archiectures. To do this, various types of openings at the backside of Daechung of 23 Hyang-Gyo Myung-Ryun-Dangs were investigated. After the classification in some groups according to their types and their periods of constuction, the tasnsition of the type of openings was analysed. Results are as follows. (1) The openings constructed form 16th to 17th century, the earliest form, is a ledged and battened panel window(or framed and ledged panel window) whose mullion is built on the frame of window. It is presumed that these types were widely used before 17th century. (2) The next type is ledged and battened panel window(door) (or framed and ledged panel window) which lacks a mullion. These types were thought to be customed after 18th century. (3) The lastest type, which is appeared from 19th to 20th century, is an characteristic backside opening(ledged and battened panel window or framed and ledged panel window) that among 3 column spacings the central one is enlarged in comparison with the right and left ones. Through this transition pattern of the openings, can be menifested that the trend of 20th century is to enlarge convenience of usage by constuctiong door and eliminating some windows.

  • PDF

Analysis of the Bacteria in Nuclear Medicine (핵의학 검사실내 세균 분석)

  • Shin, Seong-Gyu;Lee, Hyo-Yeong
    • Journal of the Korea Safety Management & Science
    • /
    • v.19 no.2
    • /
    • pp.95-100
    • /
    • 2017
  • In this study, the bacterial contamination level of equipments and devices in the nuclear medicine department of a university hospital was investigated. CNS was detected from the sample collected from the door opening button of the nuclear medicine department. Bacillus sp. was detected from the table and CNS with Bacillus sp. were detected from the control button at the PET-CT room no.1. Also, CNS was detected from the table and the control button at the PET-CT room no.2. In the distribution room no.1, CNS and Bacillus sp. were detected while CNS being detected from the distribution room no.2 and CNS with Bacillus sp. being detected from the distribution room no.3. In the injection room, Enterrococcus faecium and Pontoea sp. were detected. On the table of the ecsomatics room, Pontoea sp. was detected. Bacillus sp. was detected from the inside of the syringe Pb shield and CNS was detected from the outside. Enterrococcus faecium was detected from the Gamma camera table and Bacillus sp. was detected from the door grip. On the chair at the patient waiting room, Pseudomonas aeruginosa abd Bacillus sp. were detected. Therefore, it was understood that infection should be prevented by securely sterilizing examination devices after each examination, maintaining cleanliness by regular sterilization of waiting chairs and such objects with a number of direct contacts with patients, and infection education for the features of nuclear department.

A Study on Evaluation of Residential Environments and Residential Alterations for Physically Disabled Women (여성지체장애인 가정의 주택 개조 실태 및 거주자의 물리적 주거환경 평가에 관한 연구)

  • 최재순;권오정;이의정
    • Journal of the Korean Home Economics Association
    • /
    • v.39 no.11
    • /
    • pp.1-14
    • /
    • 2001
  • In order to develop a manual of residential alterations for the physically disabled, this case study was accomplished to analyze and evaluate residential environments and residential alterations for physically disabled women. Twenty-nine physically disabled women in Seoul and Kyunggi areas were the subjects of this study. With the evaluation checklist on physical environments of their housing, data on general characteristics of wall, floor, and all features and equipments and spaces of bedroom, kitchen, bathroom, living mom, entrance and balcony were gathered. Also, data on residential alterations were gathered through personal interviews. The data were collected from July 18th to July 25th in 2000. Frequency, percentage, and mean were used to analyze the data. In kitchen, small space, hee space under the sink and heights of the lower cabinets were not properly provided. In bathroom, door width, direction of opening door, adjustable height of shower, level difference, clear space for wheelchair user, and storage place were not appropriate to the disabled. Kitchen and bathroom showed high frequencies of alteration. But most of the subjects were not satisfied with the alterations of their housing. They also wanted to alter these two spaces in the future. In order to after their housing effectively appropriate information of the residential alterations was needed. If a guide or manual book for residential alterations was provided, the physically disabled people will more easily after their housing for safe and independent life.

  • PDF

Effects of the Geometry and Location of an Vertical Opening on the Fire Characteristics in the Under-Ventilated Compartment Fire (환기부족 구획화재에서 수직 개구부의 형상 및 위치가 화재특성에 미치는 영향)

  • Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong;Park, Seul-Hyun
    • Fire Science and Engineering
    • /
    • v.27 no.3
    • /
    • pp.20-29
    • /
    • 2013
  • To investigate numerically the effects of geometry and location of vertical opening on the thermal and chemical fire characteristics in full-scale under-ventilated compartment fires, the ventilation factor ($A\sqrt{h}$) to estimate a theoretical maximum inflow of ambient air and the mass loss rate in a heptane pool fire were fixed for all cases. It was shown that variations in door geometry affected significantly the change in thermal and chemical characteristics inside the compartment. Variations in window location resulted in the complex change in additional fire characteristics including the fire duration time and recirculating flow structure. These results were analyzed in details by the multi-dimensional flow and fire characteristics including the vent flow and fuel/air mixing phenomena.