• Title/Summary/Keyword: open set

Search Result 1,093, Processing Time 0.026 seconds

Dose Evaluation at The Build Up Region Using by Wedge Filter (쐐기필터 사용에 따른 선량증가 영역에서 선량평가)

  • Kim, Yon-Lae;Moon, Seong-Kong;Suh, Tae-Suk;Chung, Jin-Beom;Kim, Jin-Young;Lee, Jeong-Woo
    • Journal of radiological science and technology
    • /
    • v.37 no.4
    • /
    • pp.341-348
    • /
    • 2014
  • Wedge filter could use to increase the dose distribution at the hot dose regions. We evaluated dose discrepancy at surface and build region in the infield and outfield that Metal Wedge (MW) and Enhance Dynamic Wedge (EDW) were interact with photon. In this paper, we used Gafchromic EBT3 film that had excellent spatial resolution, composed the water equivalent materials and changed the optical density without development. The set up conditions of linear accelerator were fixed 6 MV photon, 100 cm SSD, $10{\times}10cm^2$ field size and were irradiated 400 cGy at Dmax. The dose distribution and absorbed dose were evaluated when we compared the open field with $15^{\circ}$, $30^{\circ}$, $45^{\circ}$ metal wedge and enhanced dynamic wedge. A $15^{\circ}$ metal wedge could increase the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. A $30^{\circ}$ metal wedge could decrease the surface and build up region dose than using a $30^{\circ}$ enhanced dynamic wedge. A $45^{\circ}$ metal wedge could decrease by large deviation the surface and build up region dose than using a $15^{\circ}$ enhanced dynamic wedge. The dose of penumbra region at outfield were increased on the thick side but were decreased on the thin side. It could be decrease the surface dose and build up region dose, if the metal wedge filters were properly used to make a good dose distribution and not closed the distance of surface.

Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator (CLINAC 1800 선형가속기의 15 MV X-선의 특성)

  • Kim, Kye-Jun;Lee, Jong-Young;Park, Kyung-Ran
    • Radiation Oncology Journal
    • /
    • v.9 no.1
    • /
    • pp.131-141
    • /
    • 1991
  • A comprehensive set of dosimetric measurements has been made on the Varian Clinac 1800 15 MV photon beam. Beam quality, percentage depth dose, dose in the build up region, output, symmetry and flatness, transmission through iead (Cerrobend), tray attenuation, isodose curves for the open and wedged fields were measured using 3 dimensional water phantom dosimetry system (including film densitometer system) and polystyrene phantoms. These dosimetric measurements sufficiently characterized the beam to permit clinical use. The depth dose characteristics of photon beam is $d_{max}$ of 3.0 cm and percentage depth dose of $76.8\%$ at 10 cm,100 cm source-surface distance, field size of $10\times10\;cm^2$ for 15 MV X-ray beam. The Output factors ranged 0.927 for $4\times4\;cm^2$ field to 1,087 for $35\times35\;cm^2$ field. The build-up level of maximum dose was at 3.0 cm and surface dose was approximately $15.5\%$ for a field size $10\times10\;cm^2$ The stability of output is $within\pm1\%$ and flatness and symmetry are $within\pm3\%$. The half value thickness (HVL) of lead is 13 mm, which corresponds to an attenuation coefficient of $0.053\;mm^{-1}$. These figures compare facorably with the manufacturesr`s specifications.

  • PDF

The Effect of Aquaplast on Surface Dose of Photon Beam (Aquaplast가 광자선의 표면선량에 미치는 영향)

  • Oh, Do-Hoon;Bae, Hoon-Sik
    • Radiation Oncology Journal
    • /
    • v.13 no.1
    • /
    • pp.95-100
    • /
    • 1995
  • Purpose : To evaluate the effect on surface dose due to Aquaplast used for immobilizing the patients with head and neck cancers in photon beam radiotherapy Materials and Methods: To assess surface and buildup region dose for 6MV X-ray from linear accelerator(Siemens Mevatron 6740), we measured percent ionization value with the Markus chamber model 30-329 manufactured by PTW Frieburg and Capintec electrometer, model WK92. For measurement of surface ionization value, the chamber was embedded in $25{\times}25{\times}3cm^3$ acrylic phantom and set on $25{\times}25{\times}5cm^3$ polystyrene phantom to allow adequate scattering. The measurements of percent depth ionization were made by placing the polystyrene layers of appropriate thickness over the chamber. The measurements were taken at 100cm SSD for $5{\times}5cm^2$, $10{\times}10cm^2$ and $15{\times}15cm^2$ field sizes, respectively. Placing the layer of Aquaplast over the chamber, the same procedures were repeated. We evaluated two types of Aquaplast: 1.6mm layer of original Aquaplast(manufactured by WFR Aquaplast Corp.) and transformed Aquaplast similar to moulded one for immobilizing the patients practically. We also measured surface ionization values with blocking tray in presence or absence of transformed Aquaplast. In calculating percent depth dose, we used the formula suggested by Gerbi and Khan to correct overresponse of the Markus chamber. Results : The surface doses for open fields of $5{\times}5cm^2$, $10{\times}10cm^2$, and $15{\times}15cm^2$ were $79\%$, $13.6\%$, and $18.7\%$, respectively. The original Aquaplast increased the surface doses upto $38.4\%$, $43.6\%$, and $47.4\%$, respectively. For transformed Aquaplast, they were $31.2\%$, $36.1\%$, and $40.5\%$, respectively. There were little differences in percent depth dose values beyond the depth of Dmax. Increasing field size, the blocking tray caused increase of the surface dose by $0.2\%$, $1.7\%$, $3.0\%$ without Aquaplast, $0.2\%$, $1.9\%$, $3.7\%$ with transformed Aquaplast, respectively. Conclusion: The original and transformed Aquaplast increased the surface dose moderately. The percent depth doses beyond Dmax, however, were not affected by Aquaplast. In conclusion, although the use of Aquaplast in practice may cause some increase of skin and buildup region dose, reductioin of skin-sparing effect will not be so significant clinically.

  • PDF

Vibration and Noise Level on the Training Ship Pusan 403 (실습선 부산 403호의 진동과 소음)

  • Park, Jung Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.8-8
    • /
    • 1987
  • This paper describes on the distribution of the vibration and the noise produced on a skipjack pole and line training ship M/S Pusan 403 (243GT, 1,000ps) under the cruising or drifting condition. The vibration and the noise level were measured by use of protable vibration analyzer (B and K 3513) and sound level meter (B and K 2205), and so the vibration level was converted into dB unit. The check points were set through every decks and around important places of the ship. The results obtained can be summarized as follows: 1. The vibration and the noise level 1) On the main deck, both the vibration and the noise level were highest at the vertically above the main engine, whereas the vibration level was the lowest in the bow store and the noise level beneath the bridge. 2) Under cruising condition, the vibration level around the cylinder head of main engine, port side of the engine room, on the shaft tunnel was 80, 67, 65 dB and the noise level 104, 87, 86 dB, respectively. 3) The vibration level on the vertical line passing through the bridge was the highest at the orlop deck with 60 dB and the lowest on the bridge deck with 55 dB, whereas the noise level the highest at the compass deck with 75 dB and the lowest at the orlop deck with 53 dB. 4) The vibration and the noise level on the open decks were the highest with 65 dB and 84 dB on the boat deck, whereas the vibration level was the lowest at the lecture room with 51 dB and the noise level the lowest at the fore castle deck with 57 dB. 5) On the orlop decks, both the vibration and the noise level were the highest at the engine room with 65 dB and 85 dB, and the lowest at bow store with 54 dB and 52 dB, respectively. Comparing with the vibration level and the noise level, the vibration level was higher than the noise level in the bow part and it was contrary in the stern part of the ship. 2. Vibration analysis 1) The vibration displacement and the vibration velocity were the greatest at the cylinder head of main engine with 100μm and 11mm/sec, and were the smallest at the compass deck with 3μm and 0.07mm/sec. They were also attenuated rapidly around the frequency of 100Hz and over. 2) The vibration acceleration was the greatest at the cylinder head with the main frequency of 1KHz and the acceleration of 1.1mm/sec super(2), and the smallest at the compass deck with 30KHz and 0.05mm/sec super(2).

Vibration and Noise Level on the Training Ship Pusan 403 (실습선 부산 403호의 진동과 소음)

  • 박중희
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.23 no.2
    • /
    • pp.54-60
    • /
    • 1987
  • This paper describes on the distribution of the vibration and the noise produced on a skipjack pole and line training ship M/S Pusan 403 (243GT, 1,000ps) under the cruising or drifting condition. The vibration and the noise level were measured by use of protable vibration analyzer (B and K 3513) and sound level meter (B and K 2205), and so the vibration level was converted into dB unit. The check points were set through every decks and around important places of the ship. The results obtained can be summarized as follows: 1. The vibration and the noise level 1) On the main deck, both the vibration and the noise level were highest at the vertically above the main engine, whereas the vibration level was the lowest in the bow store and the noise level beneath the bridge. 2) Under cruising condition, the vibration level around the cylinder head of main engine, port side of the engine room, on the shaft tunnel was 80, 67, 65 dB and the noise level 104, 87, 86 dB, respectively. 3) The vibration level on the vertical line passing through the bridge was the highest at the orlop deck with 60 dB and the lowest on the bridge deck with 55 dB, whereas the noise level the highest at the compass deck with 75 dB and the lowest at the orlop deck with 53 dB. 4) The vibration and the noise level on the open decks were the highest with 65 dB and 84 dB on the boat deck, whereas the vibration level was the lowest at the lecture room with 51 dB and the noise level the lowest at the fore castle deck with 57 dB. 5) On the orlop decks, both the vibration and the noise level were the highest at the engine room with 65 dB and 85 dB, and the lowest at bow store with 54 dB and 52 dB, respectively. Comparing with the vibration level and the noise level, the vibration level was higher than the noise level in the bow part and it was contrary in the stern part of the ship. 2. Vibration analysis 1) The vibration displacement and the vibration velocity were the greatest at the cylinder head of main engine with 100$\mu$m and 11mm/sec, and were the smallest at the compass deck with 3$\mu$m and 0.07mm/sec. They were also attenuated rapidly around the frequency of 100Hz and over. 2) The vibration acceleration was the greatest at the cylinder head with the main frequency of 1KHz and the acceleration of 1.1mm/sec super(2), and the smallest at the compass deck with 30KHz and 0.05mm/sec super(2).

  • PDF

Study on the Improvement of Stow Net Fishing Technique and the Enlargement of Fishing Ground to the Distant Waters - 1 . Model Experiment of the Net - (안강망어법의 개량과 어장의 원해로의 확대를 위한 연구 - 1 . 어구의 모형실험 -)

  • Lee, Byoung-Gee;Kim, Jin-Kun;Lee, Ju-Hee
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.24 no.2
    • /
    • pp.55-64
    • /
    • 1988
  • Stow nets have widely been used in the western sea of Korea from the olden age. The original structure of a stow net is a large square-sectional bag net made of 4 netting panels, and the front fringes of top and bottom panels are connected to the top and bottom beams respectively. Wire ropes, which is originated from the holding anchor are gradually forked and biforked, and finally 4 pieces of wire rope (biforked pendants) are jointed to each beam. Much convenience caused by long and heavy beams were problemed, then some studies have been carried out to improve the net since 1930's. The most effective improvement were achieved in 1980 by Mr. Han and his colleagues. The key point of improvement was that the beams were removed and the belt shaped shearing device made by canvas was attached to the side panels, the head rope and ground rope to the front fringe of top and bottom panel, and biforked pendants are joined to the shearing device. Even though this is the epoch-making improvement of a stow net, the further study should be required to find out more effective method. The authors carried out a model experiment on the stow net to determine the vertical and horizontal opening of a net mouth, and also examine the front, top and side-view configuration of the net. The model net was constructed depending on the Similarity Law of Fishing Gear in 1/10 and 1/20 scale and set against to the current at shallow and speedy flowing channel. The vertical and horizontal openings were determined by using scaled bamboo poles, and the configuration was observed by using specially prepared observation platform and underwater observation glass, and also photographed by using specially prepared underwater photographic equipment. The results obtained can be summarized as follows: 1. The opening height and width of the shearing device varied in accordance with the relative length of the biforked pendants. Considering the height and width of shearing device in 6 cases of the arrangement system of biforked pendants, the best result was obtained in the case that the 2nd, 3rd and 4th pendents from the bottom-most was 5%, 9% and 4% longer than that. 2. On the top-view configuration the excessive deformation of head rope and ground rope were observed. In the actual net, 54m long head rope and ground rope were attached to the front fringe of top and bottom panels so that the head rope may be lifted to make the net mouth open highly. But actually the head rope and the ground rope are streamed backward without any lift, and also the netting followed the ropes were deformed until the 2/5 in the whole length of the net. This deformation may be guessed to disturb the entrance of fish school into the net and also caused the net to get caught by obstacles in the sea bed and to be broken largely. 3. Hydrodynamic resistance R of the actual net may be deduced as R(kg)=29.2$\times$103 v1.65. It is also expressed as R(kg)=5.9$\times$d/l$\times$ab v1.65. depending on the formula deduced by Koyama to estimate the resistance of trawl nets, where d/l denote the ratio between diameter of netting twine and length of mesh leg in every part of side panel, a and b, the stretched circumference of the mouth and the stretched length of the net, respectively.

  • PDF

Comparative Analysis of arterial Gases and Acid-base status in Patients with Congenital and Acquired Heart Disease at Preoperative Period, During Extracorporeal Circulation. and Postoperative Period (선천성 및 후천성 심질환 환자에서 체외순환 전, 중, 후의 동맥혈 가스의 비교 분석)

  • 이동석;이봉근;김송명
    • Journal of Chest Surgery
    • /
    • v.34 no.11
    • /
    • pp.831-842
    • /
    • 2001
  • Background: Patients with cardiac diseases who have structural defects in their heart bring about metabolic insult such as preoperative acid-base imbalance. Cardiac operation requires many nonphysiologic procedures such as extracorporeal circulation, hypothermia, and hemodilution. We studied the acid-base status of surgical heart diseases pre-operatively, during extracorporeal circulation, and post-operatively and researched the treatment indications of acid-base disturbances. Material and Method: From January 1997 to May 1999, fifty two cases of open heart surgery were carried out under extracorporeal circulation, which divided into a set of pediatric and adult groups, congenital and acquired groups, non-cyanotic and cyanotic groups, The $\alpha$ -stat arterial blood gas analysis was done in each group during the preoperative period, during the operation with extracorporeal circulation, and during the postoperative period. Result: Before surgery, all patients present metabolic acidosis, PaO2 was low in adult group and acquired group and compensatory respiratory alkalosis was noted in cyanotic group. During extracorporeal circulation, adult group revealed alkalosis and normal in acquired group. Pediatric group presents low Pa$CO_2$, metabolic acidosis and respiratory alkalosis. Congenital group and non-cyanotic group showed non-compensatory alkalosis trend and non-compensatory respiratory acidosis were observed in cyanotic group during extracorporeal circulation. Postoperative acid-base status of adult group was recovered to normal and the standard bicarbonate was increased in the acquired group. All of the pediatric, congenital non-cyanotic, and cyanotic groups revealed the lack of buffer base.

  • PDF

A Research on the Regulations and Perception of Interactive Game in Data Broadcasting: Special Emphasis on the TV-Betting Game (데이터방송 인터랙티브 게임 규제 및 이용자 인식에 관한 연구: 승부게임을 중심으로)

  • Byun, Dong-Hyun;Jung, Moon-Ryul;Bae, Hong-Seob
    • Korean journal of communication and information
    • /
    • v.35
    • /
    • pp.250-291
    • /
    • 2006
  • This study examines the regulatory issues and introduction problems of TV-betting data broadcasts in Korea by in-depth interview with a panel group. TV-betting data broadcast services of card games and horse racing games are widely in use in Europe and other parts of the world. In order to carry out the study, a demo program of TV-betting data broadcast in the OCAP(OpenCableTM Application Platform Specification) system environment, which is the data broadcasting standard for digital cable broadcasts in Korea was exposed to the panel group and then they were interviewed after watching and using the program. The results could be summarized as below. First of all, while TV-betting data broadcasts have many elements of entertainment, the respondents thought that it would be difficult to introduce TV-betting in data broadcasts as in overseas countries largely due to social factors. In addition, in order to introduce TV-betting data broadcasts, they suggested that excessive speculativeness must be suppressed through a series of regulatory system devices, such as by guaranteeing credibility of the media based on safe security systems for transactions, scheduling programs with effective time constraints to prevent the games from running too frequently, limiting the betting values, and by prohibiting access to games through set-top boxes of other data broadcast subscribers. The general consensus was that TV-betting could be considered for gradual introduction within the governmental laws and regulations that would minimize its ill effects. Therefore, the government should formulate long-term regulations and policies for data broadcasts. Once the groundwork is laid for safe introduction of TV-betting on data broadcasts within the boundary of laws and regulations, interactive TV games are expected to be introduced in Korea not only for added functionality of entertainment but also for far-ranging development of data broadcast and new media industries.

  • PDF

The Effects of Hot Water Extraction of Wood Meal and the Addition of CaCl2 on Bending Strength and Swelling Ratio of Wood-Cement Board (목질(木質)의 열수추출(熱水抽出) 및 CaCl2 첨가(添加)가 목질(木質)-세멘트 보드의 휨강도(强度) 및 팽윤율(膨潤率)에 미치는 영향(影響))

  • Ahn, Won-Yung;Shin, Dong-So;Choi, Don-Ha
    • Journal of the Korean Wood Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.49-53
    • /
    • 1985
  • The effects of pre-treatments, the hot water extraction of wood meal and the addition of chemical ($CaCl_2$) to wood-cement water system on the properties of wood-cement composite such as modulus of rupture (MOR), modulus of elasticity (MOE), water sorption ratio and swelling ratio of resulting boards were studied in this experiment. The wood meals through 0.83mm(20 mesh) and retained on 0.42mm(35 mesh) screen were prepared from Pinus densiflora S. at Z. and Larix leptolepsis G. For hot water extraction, 500 grams of wood meal for each species were heated to boiling with 1,500ml of distilled water in 2-liter beaker for 6 hours. Every 2 hours, the wood meals were washed with boiling distil1ed water and reheated to boiling again. After 6 hours boiling, the boiled wood particles were collected by pouring this particles on 200 mesh screen. The collected particles then washed twice with hot distilled water and dried for 24 hours in an oven at $109{\pm}20^{\circ}C$. A mixture of 663.4 grams of cement with 331.7 grams of wood meal based on oven-dry weight were dry-mixed in a plastic vessel. The mixture was kneaded with 497.6ml of distilled water in the ratio of 1.5ml of water to a gram of wood meal. To add calcium chloride to the mixture as an accelerator, $CaCl_2$ 4% solution by weight per volume, was added to pine-or larch-cement board in the ratio of 3% to cement weight. To set wood-cement board, this mixture was clamped at 30cm ${\times}$ 30cm, in thickness of 1.5cm for 3 days at room temperature, declamped and then placed at open condition for 17 days. The target density was 1.0. The four specimens sized to 5cm in width and 28cm in length were used for MOR and MOE test for each treatment. After MOR test, the tested specimens were cut to the size of 5cm ${\times}$ 5cm for water sorption and swelling test. The twenty specimens used to measure the water sorption ratio (soaking 24 hours) and ten of these were used for swelling ratio measurement The results obtained were as follows: 1) Larch was not suitable for wood-cement boards because larch-cement board developed no strength, but pine showed 97.9kg/$cm^2$ by hot water extraction. 2) To increase MOR, hot water extraction was more effective than the addition of $CaCl_2$ in pine and larch because the $CaCl_2$ addition was seemed to speed up the ratio of cement hydration without reacting with the wood substances. 3) The water sorption ratio was lowered by the addition of $CaCl_2$ to wood-cement system because the chemical additive accelerated the rate of cement hydration. 4) In pine-cement board, the swelling ratio from 0.37 to 0.42 percent was observed in length and the swelling ratio from 0.88 to 2.0 percent in thickness. As a rule, the swelling ratio of wood-cement board was very low and the swelling ratio in thickness was higher than in length.

  • PDF

Effect of Root Zone Cooling Using the Air Duct on Temperatures and Growth of Paprika During Hot Temperature Period (공기순환 덕트를 이용한 근권부 냉방이 고온기 파프리카 재배에서 온도와 생육에 미치는 영향)

  • Choi, Ki Young;Jang, Eun Ji;Rhee, Han Cheol;Yeo, Kyung-Hwan;Choi, Eun Young;Kim, Il Seop;Lee, Yong-Beom
    • Journal of Bio-Environment Control
    • /
    • v.24 no.3
    • /
    • pp.243-251
    • /
    • 2015
  • This study aimed to determine the effects of root zone cooling using air duct on air temperature distribution and root zone and leaf temperatures of sweet pepper (Capsicum annum L. 'Veyron') grown on coir substrate hydroponic system in a greenhouse. When the air duct was laid at the passage adjacent the slab, the direction of air blowing was upstream at $45^{\circ}$. The cooling temperature was set at $20^{\circ}C$ for day and $18^{\circ}C$ for night. For cooing timing treatments, the cooling air was applied at all day (All-day), only night time (5 p.m. to 1 a.m.; Night), or no cooling (Control). The air temperature inside the greenhouse at a height of 40 and 80cm above the floor, and substrate and leaf temperatures, fruit characteristics, and fruit ratio were measured. Under the All-day treatment, the air temperature was decreased about $4.4{\sim}5.1^{\circ}C$ at the height of 40cm and $2.1{\sim}3.1^{\circ}C$ at the height of 80cm. Under the Night treatment, the air temperature was decreased about $3.4{\sim}3.8^{\circ}C$ at the height of 40cm and $2.2{\sim}2.7^{\circ}C$ at the height of 80cm. The daily average temperature in the substrate was in the order of the Control ($27.7^{\circ}C$) > Night ($24.1^{\circ}C$) > All-day ($22.8^{\circ}C$) treatment. Cooling the passage with either upstream blowing at $45^{\circ}$ or horizontal blowing at $180^{\circ}$ was effective in lowering the air temperature at a height of 50cm; however, no difference at a height of 100cm. Cooling the passage with perpendicular direction at $90^{\circ}$ was effective in lowering the air temperature at the height between 100 and 200cm above the floor; however, no effect on the temperature at the height of 50cm. A greater decrease in leaf temperature was found at 7 p.m. than that at 9. a.m. under both All-day and Night treatments. Fresh weight partitioning of fruit was in the order of the All-day (48.6%) > Night (45.6%) > Control (24.4%) treatment. A higher fruit production was observed under the All-day treatment, in which the accumulated average temperature was the lowest, and it may have been led to a higher proportion of photosynthate distributed to fruit than other treatments.