• Title/Summary/Keyword: open eye

Search Result 174, Processing Time 0.02 seconds

A Grounded Theory Approach on the Experience of Foster Care Child's Biological Parents (가정위탁아동 친부모의 경험에 대한 근거이론접근)

  • Kim, Jin-Sook;Lee, Keun-Moo
    • Korean Journal of Social Welfare Studies
    • /
    • v.42 no.3
    • /
    • pp.85-119
    • /
    • 2011
  • This Study was to explore the experience of foster care child's biological parents and proposed the practical discuss and method for support their returning home. We approached grounded theory to subject. Twenty biological parent's of foster child participated this research. The Data were collected by in depth-interview and documents. The authors analyzed the data according to frame that proposed Strauss and Corbin(1998). The results as follows: In open coding 143 concepts, 34 subcategory, 13 category. In axial coding the causal conditions were 「self-devaluation」, 「self-stigma」, 「social prejudice」. and the phenomenon were 「life as surplus being」, 「revolving around the world」, and the contextual conditions were 「collapse of life base」, 「rustical fatalism」. The intervention conditions were 「operation of support system」, 「instinct of maternity」. The action/interception strategy were 「closing of single eye」, 「pussling of scattered piece」. The consequence were 「fixations of abandonment」. 「resoaring to the world」 The authors proposed the core category as 「go over the wall of world burdening liabilities of being」. The authors classified patricians life type as 「challenging type」, 「status quo type」, 「escaping type」, Finally, we proposed the practical method for support restoring family the world」, foster care child's biological parents.

A Study on Comparison of Outdoor Wind Pressure Performance According to Outdoor Exposure and Acceleration Deterioration Methods of Structural Sealants Applied to Curtain Wall (커튼월에 적용된 구조용 실링재의 옥외폭로와 실내복합열화 처리방법에 따른 내풍압성능 비교연구)

  • Jang, Pil Sung;Hong, Soon Gu;Kim, Sung Rae
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.9
    • /
    • pp.279-287
    • /
    • 2018
  • Sealants are an important element of modern architecture and serve as a building protection against weathering by providing barriers against ingress of moisture, air, and other materials. Exposure to a variety of environments often reduces lifespan due to changes in physical, chemical and mechanical characteristics, and UV, humidity, and temperature expansion are important issues that are directly related to durability. In this study, a combined deterioration test chamber was developed to simulate the environment of the open air as an instrument for verifying the durability of structural sealing materials indoors. In order to replicate special weather conditions, such as yellow dust, acid rain, and contamination by microorganisms, it was deemed impossible to replicate the outdoor environment by 100 %, and the results of the results of the results of the external exposure test of the structural sealant and the combined deterioration testing device. As a result of the displacement test of the outdoor exposure test, it was determined that the sealant was breaking apart and that it would be smooth, and the displacement would be up to three times greater than the initial material value of 1 year. The displacement test results of the combined deterioration test device show the tendency to deteriorate, decreasing the elasticity and tensile characteristics. In the case of denatured silicon, the current 400 cycles have been completed to confirm 12 months of degradation of the external exposure. The deformation of the test specimen cannot be verified with the naked eye, so it is considered that the conditions of the specimen are more stable than the silicon sealant. As a result of the outdoor exposure test, if the combined deterioration test device is structured and proposed in the relevant guidance or specification, the anticipated lifespan of 12 months in the actual use environment can be verified indoors and below 3 months later, economically.

A Study on the Spatial Control Effect of Panjang in Donggwoldo (동궐도(東闕圖) 판장(板墻)의 공간통제 효과에 관한 연구)

  • HA Yujeong;KIM Choongsik
    • Korean Journal of Heritage: History & Science
    • /
    • v.55 no.4
    • /
    • pp.196-209
    • /
    • 2022
  • This study compared and analyzed the spatial division function and role of partitions by comparing the entire space and the spatial changes before and after the installation of partitions in <Donggwoldo>, which was manufactured in the late Joseon Dynasty. As a research method, a set standard was prepared to decompose the space of <Donggwoldo> into a unit space, and the standard was set according to the role and height of the space by classifying it into a main space, sub space, and transition space. Two convex maps were prepared according to before and after the installation of the Panjang, and the values of connectivity, control, and integration, which are spatial syntax variables, were calculated and analyzed. The results of the study are as follows. First, the partition in <Donggwoldo(東闕圖)> did not affect the overall spatial arrangement and control or connection of Donggwol, but the movement and access of space is limited to specific areas. Second, the partition was a facility intensively distributed in Naejeon(內殿) and Donggung(東宮) to be used actively in the way of space utilization. It shows that the unit space increased rapidly due to the installation of the partition. Since the partition was installed in the spaces that were open and under high control in the case of Naejeon(內殿), it helped to secure private spaces as closed ones under low control. On the other hand, for Donggung(東宮), the spaces were compartmented and divided with the partition to guide the movement path through narrow gates of the partition and increase the depth of the space. This helped to create spaces that are free and can be hidden as it increased the number of spaces coming through. Third, In addition to the functions of "eye blocking, space division, and movement path control" revealed in prior research, the partition has created a "space that is easy to control" within a specific area. The installation of the partition reduced the scale through the separation of spaces, but it occurred the expansion of the movement path and space. Also, the partition functioned to strengthen hiding and closure or increase openness as well through space division. This study is significant in that it revealed the value of the spatial control function of panjang through the analysis of spatial control and depth by analyzing the function of the partition with a mathematical model in addition to the analysis and study of the function and role of panjang. In addition, it is valuable in that it has prepared a framework for analysis tools that can be applied to traditional residential complexes similar to palaces by applying space syntax to <Donggungdo> to create convex spaces according to unit space division and connection types of palace architecture and landscape elements.

The study of MDCT of Radiation dose in the department of Radiology of general hospitals in the local area (일 지역 종합병원 영상의학과 MDCT선량에 대한 연구)

  • Shin, Jung-Sub
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.4
    • /
    • pp.281-290
    • /
    • 2012
  • The difference of radiation dose of MDCT due to different protocols between hospitals was analyzed by CTDI, DLP, the number of Slice and the number of DLP/Slice in 30 cases of the head, the abdomen and the chest that have 10 cases each from MDCT examination of the department of diagnostic imaging of three general hospitals in Gyeongsangbuk-do. The difference of image quality, CTDI, DLP, radiation dose in the eye and radiation dose in thyroid was analyzed after both helical scan and normal scan for head CT were performed because a protocol of head CT is relatively simple and head CT is the most frequent case. Head CT was significantly higher in two-thirds of hospitals compared to A hospital that does not exceed a CTDI diagnostic reference level (IAEA 50mGy, Korea 60mGy) (p<0.001). DLP was higher in one-third of hospitals than a diagnostic reference level of IAEA 1,050mGy.cm and Korea 1,000mGy.cm and two-thirds exceeded the recommendation of Korea and those were significantly higher than A hospital that does not exceed a diagnostic reference level (p<0.001). Abdomen CT showed 119mGy that was higher than a diagnostic reference level of IAEA 25mGy and Korea 20mGy in one-third. DLP in all hospitals was higher that Korea recommendation of 700mGy.cm. Among target hospitals, C hospital showed high radiation dose in all tests because MPR and 3D were of great importance due to low pitch and high Tube Curren. To analyze the difference of radiation dose by scan methods, normal scan and helical scan for head CT of the same patient were performed. In the result, CTDI and DLP of helical CT were higher 63.4% and 93.7% than normal scan (p<0.05, p<0.01). However, normal scan of radiation dose in thyroid was higher 87.26% (p<0.01). Beam of helical CT looked like a bell in the deep part and the marginal part so thyroid was exposed with low radiation dose deviated from central beam. In addition, helical scan used Gantry angle perpendicularly and normal scan used it parallel to the orbitomeatal line. Therefore, radiation dose in thyroid decreased in helical scan. However, a protocol in this study showed higher radiation dose than diagnostic reference level of KFDA. To obey the recommendation of KFDA, low Tube Curren and high pitch were demanded. In this study, the difference of image quality between normal scan and helical scan was not significant. Therefore, a standardized protocol of normal scan was generally used and protective gear for thyroid was needed except a special case. We studied a part of CT cases in the local area. Therefore, the result could not represent the entire cases. However, we confirmed that patient's radiation dose in some cases exceeded the recommendation and the deviation between hospitals was observed. To improve this issue, doctors of diagnostic imaging or technologists of radiology should perform CT by the optimized protocol to decrease a level of CT radiation and also reveal radiation dose for the right to know of patients. However, they had little understanding of the situation. Therefore, the effort of relevant agencies with education program for CT radiation dose, release of radiation dose from CT examination and addition of radiation dose control and open CT contents into evaluation for hospital services and certification, and also the effort of health professionals with the best protocol to realize optimized CT examination.