• Title/Summary/Keyword: open circuit potential

Search Result 206, Processing Time 0.035 seconds

A Study on Circuit Topology for the Electrical Power Failure and Open-Phase Fault Detection of Industrial Field (산업현장 정전 및 결상사고 감지회로 토폴로지 연구)

  • Park, Dong-Hun;Kwak, Dong-Kurl;Jeon, Hoe-Joong;Jeon, Ho-Jin
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.540-542
    • /
    • 2019
  • This paper proposes an open-phase fault control system using 3-phase neutral voltage. The proposed control system is designed as a new topology which uses the potential difference between neutral point and ground of three phase. The open-phase detection system is also configured to Y-wiring of three capacitance devices of the same capacity to each line of three phase power source R-S-T. This paper also designs a mobile phone application for remote alarm of open-phase fault.

  • PDF

A Study on the Elimination of Temporary overvoltage Due to Ferroresonance at Gas Insulated Switchgear (Gas 색연(絶綠) 개폐장치(開閉裝置)의 철공진(鐵共振) 제어대책(制御對策)에 관한 연구(硏究))

  • Kim, S.K.;Kim, T.S.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2000.05b
    • /
    • pp.216-221
    • /
    • 2000
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP(Electro- magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computationl model.

  • PDF

A analysis result on the PT ferroresonance at 154 kV GIS substation (154 kV GIS의 PT 철공진 소손사례와 원인규명)

  • Woo, J.W.;Shim, E.B.;Kim, S.K.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07e
    • /
    • pp.2076-2079
    • /
    • 1999
  • This paper describes the analysis results on the PT ferroresonance at 154 kV GIS (gas Insulated substation by EMTP (Electro-magnetic Transient Program). We had simulated the PT ferroresonance between a potential transformer(PT) and an open circuit breaker's grading capacitance. The ferroresonance leads to very large power frequency overvoltages on PT bus and subsequent insulation failure. The large power can be supplied to the PT by the high voltage on the opened circuit due to the grading capacitance and equivalent capacitance of the buses during the ferroresonance. The damping circuit connected on the secondary winding were considered in the model. The actual countermeasure include a saturable inductor and a resistor series-mounted, but the 2 ohms of damping resistance was used in the computational model.

  • PDF

A Study on the Short-circuit Protection System for Learning Teaching Instruction Using Incandescent Light Bulb (백열전구를 이용한 학습 교구용 단락보호장치에 대한 고찰)

  • Hong-yong Kim
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.4
    • /
    • pp.844-850
    • /
    • 2023
  • Purpose: This paper is about the development of a short-circuit protection power supply device using incandescent bulbs and its application for educational materials. This article, which considers electrical safety and energy conservation at the same time, has many kinds of potential applications for both educational and industrial areas. The above mentioned short-circuit protection power supply device using incandescent bulbs enhances safety and efficiency compared to normal current power supply devices. Additionally, as an educational materials, it can be used for electric safety training, and provides practical electrical safety knowledge on our actual life. Method: Using incandescent bulbs, design new type of short-circuit protection power supply device, and through verifying the function and safety of the device, make new type device, and applying it for an educational tool. Conclusion: This study is to develop new type of power supply device, and verify the possibility of the application for the device as an educational materials. Through this research, show an innovative solution, which contribute to electrical safety and energy conservation, and open the potential possibility on educational and industrial sectors.This kind of research is expected to contributes to enhanced research, and education on electrical safety and energy conservation management.

The Effect of LiBr Concentration on Corrosion of Absorption Refrigeration Systems Using $LiBr-H_2O$ Working Fluids ($LiBr-H_2O$계 흡수식냉동기의 부식에 미치는 LiBr 농도의 영향)

  • Lim Uh Joh;Jeong Ki Cheol
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.4 s.16
    • /
    • pp.33-39
    • /
    • 2001
  • This paper was studied on corrosion behavior of absorption refrigeration systems using $LiBr-H_2O$ working fluids. In the various concentration of lithium bromide solution, polarization test of SS 400, Cu(C1220T-OL) and Al-Ni bronze is carried out. And the corrosion behavior of materials forming absorption refrigeration systems is investigated. The main results are as following: 1) As concentration of lithium bromide solution increases, polarization resistance of materials of each kinds is low. And open circuit potential becomes less noble, the corrosion current density is high drained 2) Open circuit potential of SS 400 is less noble than that of Cu and Al-Ni bronze, corrosion current density of SS5 400 is high drained than that of Cu and Al-Ni bronze. 3) Anodic polarization of Cu and Al-Ni bronze in $62\%$ LiBr solution continues the active state. that of Cu and Al-Ni bronze in the natural sea water maintains the active state and the critical current for passivation appears.

  • PDF

Analytical Performance Modelling of Slotted Surface-Mounted Permanent Magnet Machines with Rotor Eccentricity

  • Yan, Bo;Wang, Xiuhe;Yang, Yubo
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.778-789
    • /
    • 2017
  • This paper presents an improved subdomain method to predict the magnet field distributions and electromagnetic performance of the surface-mounted permanent magnet (SPM) machines with static or dynamic eccentricity. Conventional subdomain models are either based on the scalar magnet potential to predict the rotor eccentricity effect or dependent on the magnetic vector potential without considering the eccentric rotor. In this paper, both the magnetic vector potential and the perturbation theory are introduced in order to accurately calculate the effect of rotor eccentricity on the open-circuit and armature reaction performance. The calculation results are presented and validated by the corresponding finite-element method (FEM) results.

Effect of Nitrogen Ion Implantation on Corrosion Resistance of Biocompatible Ti Implant (질소이온의 주입이 생체안전성 티타늄임플란트의 내식성에 미치는 영향)

  • 최종운;손선희
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.134-139
    • /
    • 1999
  • In this study, PSII(plasma source ion implantation) was used to improve the biocompatibility of bone-anchored Ti implant. According to potentiodynamic anodic polarization test in deaerated Hank's solution, open circuit potential of ion implanted specimens were increased compare to that of unimplanted specimen ; besides, passive current density and critical anodic current density of ion implanted specimens were lower than unimplanted specimen.

  • PDF

Electrosorption of Uranium Ions in Liquid Waste

  • Lee, Hye-Young;Jung, Chong-Hun;Oh, Won-Zin;Park, Jin-Ho;Shul, Yong-Gun
    • Carbon letters
    • /
    • v.4 no.2
    • /
    • pp.64-68
    • /
    • 2003
  • A study on the electrosorption of uranium ions onto a porous activated carbon fiber (ACF) was performed to treat uraniumcontaining lagoon sludge. The result of the continuous flow-through cell electrosorption experiments showed that the applied negative potential increased the adsorption kinetics and capacity in comparison to the open-circuit potential (OCP) adsorption for uranium ions. Effective U(VI) removal is accomplished when a negative potential is applied to the activated carbon fiber (ACF) electrode. For a feed concentration of 100 mg/L, the concentration of U(VI) in the cell effluent is reduced to less than 1 mg/L. The selective removal of uranium ions from electrolyte was possible by the electrosorption process.

  • PDF

Corrosion Behavior of the parts of Carbon Steel Bolted GECM(Graphite Epoxy Composite Material)/Al plates (탄소강 볼트 체결된 GECM(Graphite Epoxy Composite Material)/Al 판재의 구성 부재의 부식 거동)

  • Kim, Youngsik;Park, Sujin;Yoo, Youngran
    • Corrosion Science and Technology
    • /
    • v.11 no.6
    • /
    • pp.232-241
    • /
    • 2012
  • This work focused on corrosion of carbon steel bolted GECM/Al parts in tap water and NaCl solutions. In tap water and NaCl solutions, open circuit potential of GECM and its potentials in a series of carbon steel bolt>Ti>Al became active. Regardless of test materials, open circuit potentials in tap water were noble, and increasing NaCl concentration, its potentials became active. Immersion test of single specimen showed that no corrosion occur in Ti and GECM. In tap water, carbon steel bolt didn't show red corrosion product and in chloride solutions, corrosion rate in 1% NaCl solution was greater than its rate in 3.5% NaCl solution and red corrosion product in 1% NaCl solution was earlier observed than that in 3.5% NaCl solution. It seems that this behavior would be related to zinc-coatings on the surface of carbon stee l bolt. On the other hand, aluminium was corroded in tap water and chloride solutions. Corrosion of aluminium in tap water was due to the presence of chloride ion in tap water by sterilizing process.

Reference Electrode at Molten Salt: A Comparative Analysis of Electroceramic Membranes

  • Yoon, Seokjoo;Kang, Dokyu;Sohn, Sungjune;Park, Jaeyeong;Lee, Minho;Choi, Sungyeol
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.2
    • /
    • pp.143-155
    • /
    • 2020
  • A reference electrode is important for controlling electrochemical reactions. Evaluating properties such as the reduction potential of the elements is necessary to optimize the electrochemical processes in pyroprocessing, especially in a multicomponent environment. In molten chloride systems, which are widely used in pyroprocessing, a reference electrode is made by enclosing the silver wire and molten salt solution containing silver chloride into the membranes. However, owing to the high temperature of the molten salt, the choice of the membrane for the reference electrode is limited. In this study, three types of electroceramic, mullite, Pyrex, and quartz, were compared as reference electrode membranes. They are widely used in molten salt electrochemical processes. The potential measurements between the two reference electrode systems showed that the mullite membrane has potential deviations of approximately 50 mV or less at temperatures higher than 650℃, Pyrex at temperatures lower than 500℃, and quartz at temperatures higher than 800℃. Cyclic voltammograms with different membranes showed a significant potential shift when different membranes were utilized. This research demonstrated the uncertainties of potential measurement by a single membrane and the potential shift that occurs because of the use of different membranes.