• Title/Summary/Keyword: open circuit

Search Result 1,168, Processing Time 0.026 seconds

Study on the Sulfide Corrosion to the Internal Surface of Transportation Pipeline

  • Zhang, Yiling;Qi, Ping;Kong, Dehong
    • Corrosion Science and Technology
    • /
    • v.7 no.4
    • /
    • pp.193-196
    • /
    • 2008
  • This article briefly tests and analyzes the sulfur content and the distribution of active sulfur in the crude oil of Kurkow Kazakhstan and Siberian Russian, and discusses the relationship between active sulfur content and total sulfur content, active sulfur and corrosion. At the same time, it measures the open circuit potential of X70 steel and X60 steel witch have been immerged in the above two kind of crude oil for a period of time, discusses the sulfur corrosion to metal.

A Study on Open-Frame Type DC-DC Converter Module with High Power Density (높은 전력밀도를 갖는 개방형 DC-DC 컨버터 모듈에 관한 연구)

  • Yon Je-Sun;Ahn Tae-Young
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.1266-1268
    • /
    • 2004
  • This is a thesis that a quarter-brick size of 100W class open-frame type on board power module comprising telecommunication application is reported. The input voltage is established between 36 and 75 in range in order for power module to be utilized for the telecommunication application, and output were set at 3.3V and 30A. A number of parts used for transformer, inductor, and hit sink are composed of PCB in order for DC-DC converter to be lowered below 8 mm. A constant current control circuit was annexed to the system as well as basic protection prototypes such as over-voltage, over-current, and over-temperature were well considered to enhance more credibility, and were tested. As a result, high circuit performance and credibility turned out to be significant.

  • PDF

Control-to-output Transfer Function of the Open-loop Step-up Converter in CCM Operation

  • Wang, Faqiang;Ma, Xikui
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1562-1568
    • /
    • 2014
  • Based on the average method and the geometrical technique to calculate the average value, the average model of the open-loop step-up converter in CCM operation is established. The DC equilibrium point and corresponding small signal model is derived. The control-to-output transfer function is presented and analyzed. The theoretical analysis and PSIM simulations shows that the control-to-output transfer function includes not only the DC input voltage and the DC duty cycle, but also the two inductors, the two energy-transferring capacitors, the switching frequency and the load. Finally, the hardware circuit is designed, and the circuit experimental results are given to confirm the effectiveness of theoretical derivations and analysis.

A Study on the Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Atomic Layer-Deposited Thin-Film Electrolyte (수소연료를 이용하는 원자층증착 박막전해질 세라믹연료전지의 초기성능 저하에 관한 연구)

  • JI, SANGHOON
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.5
    • /
    • pp.410-416
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~17% for 40 minutes, which rapidly decreased in the early stage of the performance evaluation but gradually decreased. The open circuit voltage ratio decreased with respect time; however, its time behavior was remarkably different with the reduction behavior of the peak power density ratio. The activation resistance ratio increased as ~15% for 40 minutes, which was almost similar with the time behavior of the peak power density ratio.

Initial Performance Degradation of Hydrogen-Fueled Ceramic Fuel Cell with Plasma-Enhanced Atomic Layer-Deposited Ultra-Thin Electrolyte (플라즈마 원자층증착 초박막전해질 수소 세라믹연료전지의 초기성능 저하)

  • JI, SANGHOON
    • Journal of Hydrogen and New Energy
    • /
    • v.32 no.5
    • /
    • pp.340-346
    • /
    • 2021
  • The initial electrochemical performance of ceramic fuel cell with thin-film electrolyte fabricated by plasma-enhanced atomic layer deposition method was evaluated in terms of peak power density ratio, open circuit voltage ratio, and activation/ohmic resistance ratios at 500℃. Hydrogen and air were used as anode fuel and cathode fuel, respectively. The peak power density ratio reduced as ~52% for 30 min, which continually decreased as time increased but degradation rate gradually decreased. The open circuit voltage ratio decreased with respect time; however, its behavior was evidently different from the reduction behavior of the peak power density. The activation resistance ratio increased as ~127% for 30 min, which was almost similar with the reduction behavior of the peak power density ratio.

Online SOH Estimation Algorithm Based on Aging Tendency of Open Circuit Voltage and Low Pass Filter (OCV 곡선의 노화 경향과 저주파 통과 필터를 이용한 실시간 SOH 추정 알고리즘)

  • Noh, Tae-Won;Bae, Jeong Hyun;Han, Hae-Chan;Lee, Byoung Kuk
    • Proceedings of the KIPE Conference
    • /
    • 2019.07a
    • /
    • pp.47-49
    • /
    • 2019
  • 본 논문은 노화로 인하여 감소하는 전기자동차용 배터리의 전류 용량을 실시간으로 추정하는 SOH (State-of-health) 알고리즘을 제안한다. 제안하는 알고리즘은 노화에 따른 OCV (Open circuit voltage) 곡선의 변화 경향을 분석하고, 저주파 통과 필터를 이용하여 추정된 OCV를 기반으로 전류 용량 및 SOH를 산출한다. 알고리즘을 검증하기 위하여 전기자동차용 배터리를 이용한 실험 및 시뮬레이션을 진행한다.

  • PDF

Machine Learning-based SOH Estimation Algorithm Using a Linear Regression Analysis (선형 회귀 분석법을 이용한 머신 러닝 기반의 SOH 추정 알고리즘)

  • Kang, Seung-Hyun;Noh, Tae-Won;Lee, Byoung-Kuk
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.26 no.4
    • /
    • pp.241-248
    • /
    • 2021
  • A battery state-of-health (SOH) estimation algorithm using a machine learning-based linear regression method is proposed for estimating battery aging. The proposed algorithm analyzes the change trend of the open-circuit voltage (OCV) curve, which is a parameter related to SOH. At this time, a section with high linearity of the SOH and OCV curves is selected and used for SOH estimation. The SOH of the aged battery is estimated according to the selected interval using a machine learning-based linear regression method. The performance of the proposed battery SOH estimation algorithm is verified through experiments and simulations using battery packs for electric vehicles.

Design and analysis of highly selective ultrawide stopband lowpass filter using lumped and distributed equivalent circuit models

  • Pankaj Singh Tomar;Manoj Singh Parihar
    • ETRI Journal
    • /
    • v.46 no.4
    • /
    • pp.716-726
    • /
    • 2024
  • An ultrawide stopband lowpass filter is reported using three stepped impedance resonators with high selectivity. The filter extends the stopband frequency range and attenuation, and two quarter-wave open stubs and three circular ground slots are introduced. The lumped and distributed equivalent models are derived and analyzed. The corresponding results are validated experimentally in a fabricated prototype. The prototype lowpass filter has a 3 dB cutoff frequency (fc) of 2.9 GHz, and the stopband is extended up to 35 GHz (12.07fc), with an attenuation level better than 20 dB throughout. The passband-to-stopband transition (3 dB-20 dB) bandwidth is 0.18 GHz, and the roll-off factor is 135 dB/GHz at 30 dB. The insertion loss is 0.3 dB at 1.6 GHz. The normalized circuit size of the proposed filter with respect to the guided wavelength is 0.04.

Electric Circuit Analysis for PV Array on Short-Circuit Failure of Bypass Diode in PV Module (PV모듈의 바이패스 다이오드 단락 고장 시 태양광어레이 회로 특성분석)

  • Lee, Chung-Geun;Shin, Woo-Gyun;Lim, Jong Rok;Hwang, Hye-Mi;Ju, Young-Chul;Jung, Young-Seok;Kang, Gi-Hwan;Chang, Hyo-Sik;Ko, Suk-Whan
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.15-25
    • /
    • 2019
  • As the installation of photovoltaic systems increases, fire accidents of PV system grow every year. Most of PV system fires have been reported to be caused by electrical components. The majority of fire accidents occurred in combiner box, which is presumed to be short-circuit accidents due to dustproof and waterproof failures or heat deterioration of blocking diode. For this reason, the blocking diode installation became optional by revised PV combiner regulation. In this paper, according to the revised regulation, reverse current that generated by voltage mismatch was measured and analyzed in PV array without a blocking diode. The factors that cause voltage mismatch in array are assumed to be shaded PV module and short circuit failure of bypass diode. As the result of experiment, there is no reverse current to flow under shading condition in module, but reverse current flows on the failure of bypass diode in module. According to the module's I-V characteristic curve analysis, open voltage was slightly reduced due to operation of bypass diode in shading. However, it showed that open circuit voltage has decreased significantly in the failure of bypass diode. This indicates that the difference in open voltage reduction of voltage mismatch factor causes reverse current to flow.

Design of a Vibration Energy Harvesting Circuit With MPPT Control (MPPT 제어 기능을 갖는 진동에너지 하베스팅 회로 설계)

  • Park, Joon-Ho;Yoon, Eun-Jung;Park, Jong-Tae;Yu, Chong-Gun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.11
    • /
    • pp.2457-2464
    • /
    • 2011
  • In this paper, a vibration energy harvesting circuit using a piezoelectric device is designed. MPPT(Maximum Power Point Tracking) control function is implemented using the electric power-voltage characteristic of a piezoelectric device to deliver the maximum power to load. The designed MPPT control circuit traces the maximum power point by periodically sampling the open circuit voltage of a full-wave rectifier circuit connected to the piezoelectric device output and delivers the maximum available power to load. The proposed vibration energy harvesting circuit is designed with $0.18{\mu}m$ CMOS process. Simulation results show that the maximum power efficiency of the designed circuit is 91%, and the chip area except pads is $700{\mu}m{\times}730{\mu}m$.